Study guide

9.3 Sewer Cleaning, CCTV Inspection & SSO Response

Alabama Water/Wastewater Operator Certification Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Alabama Regulations, Certification, Exams & Utility Administration

1.1 ADEM Division 335-10-1: Facility Classifications, Grades & Staffing Rules 1.2 Becoming Certified in Alabama: Exam Application, Operator Intern Status, Experience, Renewal & CEHs 1.3 Environmental Compliance, SDWA, Clean Water Act & NPDES Permits 1.4 Alabama's PSI-Delivered WPI Exams: Format, Grade Crosswalk & Need-to-Know Blueprints 1.5 ADEM Drinking-Water Operating Rules (Division 335-7): Control Tests, Residuals, Pressure, Cross-Connections & Records 1.6 Utility Administration: SOPs, Records, Security, Cybersecurity, Emergency Planning & Supervision

2 Chapter 2: Source Water, Wells, Coagulation, Filtration & Membranes

2.1 Source Water Hydrology, Groundwater vs. Surface Water & Protection 2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics 2.3 Flocculation Basin Design, Clarification & Sedimentation 2.4 Granular Media Filtration, Head Loss & Backwash Protocols 2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning 2.6 Wells & Groundwater Systems: Construction, Pumps, Testing and Sanitary Protection (ADEM 335-7-5)

3 Chapter 3: Water Disinfection, Chemical Addition, Stabilization & Residuals

3.1 Chlorination Chemistry, Breakpoint Chlorination & Residuals 3.2 Disinfection Byproducts (DBPs), Stage 1/2 Rules & CT Compliance 3.3 Corrosion Control, Lead and Copper Rule & Fluoridation 3.4 Iron/Manganese Removal, Water Softening & Taste/Odor Control 3.5 Water Treatment Residuals: Sludge, Backwash Recycle & Plant Discharges

4 Chapter 4: Wastewater Preliminary & Primary Treatment

4.1 Wastewater Characteristics, Screening, Shredding & Grit Removal 4.2 Primary Sedimentation Basins, Scum Removal & Clarifier Performance

5 Chapter 5: Secondary Biological Treatment: Activated Sludge

5.1 Activated Sludge Microbiology, Basin Configurations & Aeration Systems 5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics 5.3 Operational Troubleshooting (Bulking, Foaming, Pin Floc) & Process Modifications

6 Chapter 6: Fixed-Film Treatment, Lagoons, Nutrient Removal, Tertiary Filtration & Disinfection

6.1 Trickling Filters & Rotating Biological Contactors (RBCs) 6.2 Waste Stabilization Ponds, Aerated Lagoons & Alabama Grade I Lagoon Operations 6.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal 6.4 Tertiary Filtration & Membrane Bioreactors (MBRs) 6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone

7 Chapter 7: Sludge Treatment, Biosolids & Odor Control

7.1 Sludge Thickening, Aerobic Digestion & Anaerobic Digestion 7.2 Mechanical Dewatering, Polymer Conditioning & EPA 503 Biosolids Regulations 7.3 Odor Control & Wastewater Chemical Addition

8 Chapter 8: Water Distribution Systems, Installation, Metering & Water Loss

8.1 Distribution Piping Materials, Valves & Finished Water Storage Facilities 8.2 Water Main Flushing, Disinfection Protocols (AWWA C651) & Water Quality Maintenance 8.3 Distribution Hydraulics, Pressure Control & Cross-Connection Prevention 8.4 Main & Service Installation, Tapping, Repair and Utility Locating (Alabama 811) 8.5 Meters, Water Loss Control, Asset Management & Customer Service

9 Chapter 9: Wastewater Collection Systems, Lift Stations & Sewer Maintenance

9.1 Gravity Collection Networks, Manhole Construction & Self-Cleansing Velocity Standards 9.2 Wastewater Lift Stations, Submersible Pumps, Force Mains & Inflow/Infiltration (I&I) 9.3 Sewer Cleaning, CCTV Inspection & SSO Response

10 Chapter 10: Laboratory Procedures, Sampling & Environmental Compliance

10.1 Drinking Water Laboratory Analysis: Turbidity, pH, Alkalinity & Coliform Testing 10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability 10.3 Representative Sampling Protocols, Preservation, Chain of Custody & QA/QC

11 Chapter 11: Plant Equipment, Pumps, Motors & Instrumentation

11.1 Centrifugal and Positive Displacement Pumps: Operation, Cavitation & Packing/Seals 11.2 Electric Motors, Variable Frequency Drives, Flow Meters & SCADA Systems

12 Chapter 12: Safety: Chemicals, Confined Spaces & Field Hazards

12.1 Chemical Safety: Chlorine Gas Emergency Handling (Kits A & B) & Hydrogen Sulfide (H2S) Hazards 12.2 Permit-Required Confined Space Entry, Lockout/Tagout (LOTO) & Personal Protective Equipment 12.3 Field Safety: Work-Zone Traffic Control, Electrical Hazards, Fall Protection & Hazard Communication

13 Chapter 13: Water & Wastewater Mathematics: Hydraulics, Chemical Feed & Pumping

13.1 Flow Conversions, Geometry, Tank Volume & Detention Time Calculations 13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations 13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost

14 Chapter 14: Water & Wastewater Mathematics: Treatment Process Calculations

14.1 Clarifier Surface Overflow Rate, Weir Loading & Granular Filter Loading Rates 14.2 Biological Calculations: F/M Ratio, MCRT Solids Balance & Sludge Volume Index (SVI)

9.3 Sewer Cleaning, CCTV Inspection & SSO Response

Key Takeaways Explain This Topic AI

High-velocity jetting is normally set up at the downstream manhole with the nozzle working upstream, so loosened debris is pulled back to the downstream manhole and removed by vacuum.

Bucket machines drag a bucket between two manholes to remove heavy debris such as sand, gravel and rocks, while power rodders with root saws cut roots.

ADEM requires a report within 24 hours of becoming aware of an unpermitted discharge such as an SSO, followed by a written report within five days, submitted electronically.

A notifiable SSO is one that reaches surface water or may imminently and substantially endanger human health, and it must be reported as soon as possible to ADEM, the public, the county health department and affected public water systems.

SSO volume is commonly estimated as the observed overflow rate multiplied by the overflow duration.

Last updated: October 2026

9.3 Sewer Cleaning, CCTV Inspection & SSO Response

The WPI Wastewater Collection Class I outline (used for the Alabama Wastewater 1C exam) devotes 27 questions to equipment operation, evaluation and maintenance and 27 to collection system operation, maintenance and restoration . Its task lists include hydraulic cleaning (balling, flushing, poly pigs), jet rodding, blockage removal, rodding, CCTV inspection, dye and smoke testing, and identifying and responding to sanitary sewer overflows (SSOs) , collapsed pipes and pump failures.

Preventive Maintenance Programs

A good program cleans every sewer on a planned cycle and cleans hot spots (grease, roots, flat grades, sags) far more often. Records of every cleaning, the debris found and the time spent show where problems recur and justify rehabilitation. Programs often follow the CMOM approach (capacity, management, operation and maintenance) that EPA promotes for reducing SSOs.

Hydraulic Cleaning

High-velocity jetting uses a high-pressure pump to drive a hose and nozzle through the sewer.

Nozzles : penetrating nozzles with forward jets open blockages; cleaning nozzles with rear jets angled back (commonly about 15 to 45 degrees) propel the hose and scour the pipe; rotating nozzles scrub grease; water-driven root cutters cut roots.

Standard setup : park at the downstream manhole , feed the nozzle upstream against the flow, then retrieve the hose slowly while the rear jets pull debris back to the downstream manhole, where a vacuum (combination) truck removes it. Debris must not be pushed downstream into lift stations or the treatment plant.

Use a hose guide or roller at the manhole to protect the hose and the manhole.

Near service laterals, jet with care; pressure and air pushed into laterals can blow out toilet water inside homes . Reduce pressure near laterals and coordinate with customers in problem areas.

Track the jetter's water supply: a 1,000-gallon tank feeding a nozzle at 80 gpm lasts about 1,000 ÷ 80 = 12.5 1{,}000 \div 80 = 12.5 1 , 000 ÷ 80 = 12.5 minutes of jetting.

Balling uses an inflated rubber ball sized slightly smaller than the pipe; water backs up behind the ball and the high velocity around it scours the pipe. Kites, bags and poly pigs work the same way. Flushing releases a large volume of water to move light deposits.

Mechanical Cleaning

Power rodders push continuous or sectional rods with tools such as augers, corkscrews and root saws for roots and hard blockages.

Bucket machines use two winches at two manholes to drag a bucket back and forth, filling it with heavy debris such as sand, gravel and rocks that jetting cannot lift.

Hand rods handle small lines and short blockages.

Roots and Grease

Roots enter through joints and cracks. Cut them mechanically, then consider chemical root control (foaming herbicide products applied under the label and state pesticide rules) to slow regrowth. Long-term control means sealing or lining the pipe.

Fats, oils and grease (FOG) cause many SSOs. A FOG control program inspects grease interceptors and traps at restaurants, enforces the sewer use ordinance and educates residents not to pour grease down drains.

Inspection

CCTV : a crawler camera records the pipe after cleaning; defects are coded with the NASSCO PACP system (Section 9.2). Manhole inspections commonly use the companion MACP system.

Smoke testing and dye testing find inflow sources and cross-connections (Section 9.2).

Flow monitoring finds capacity limits and infiltration.

Safety : cleaning and inspection crews work from the surface; any manhole entry is a permit-required confined space with atmospheric testing (Section 12.2), and street work requires traffic control (Section 12.3).

Responding to a Sanitary Sewer Overflow

1. Stop and contain. Clear the blockage, start bypass pumping or restore the failed pump. Block storm inlets and berm the flow to keep sewage out of streams and ditches.

2. Protect the public. Post warning signs and barricades, keep people and pets away, and notify property owners affected by basement backups.

3. Clean up. Remove solids and debris, pump back what can be recovered to the sewer, wash down surfaces toward the sewer (not storm drains) and apply disinfection or lime where appropriate. Photograph the site.

4. Report under ADEM's NPDES rule (ADEM Admin. Code r. 335-6-6-.12).

Requirement What ADEM requires

24-hour report Report to ADEM within 24 hours of becoming aware of noncompliance that may endanger health or the environment, including any unpermitted discharge to a water of the state

5-day report Written report no later than 5 days after becoming aware, submitted electronically for SSOs, CSOs and bypasses

Report contents Description and cause, exact dates and times, steps taken to stop and prevent recurrence, type of event, type of overflow structure (for example, a manhole), volume discharged untreated, human health and environmental impacts, and whether the event was related to wet weather

Notifiable SSO An overflow that reaches a surface water of the state or may imminently and substantially endanger human health (for example, near water supply wells or where people may contact it). The permittee must notify ADEM, the public, the county health department and other affected entities such as public water systems as soon as possible .

Anticipated bypass at a plant Prior notice to ADEM, if possible at least 10 days before

5. Estimate the volume. The most common field method is: Volume (gal) = Overflow rate (gpm) × Duration (min) \text{Volume (gal)} = \text{Overflow rate (gpm)} \times \text{Duration (min)} Volume (gal) = Overflow rate (gpm) × Duration (min)

An overflow estimated at 30 gpm that ran for 3.5 hours (210 minutes) discharged about 30 × 210 = 6,300 30 \times 210 = 6{,}300 30 × 210 = 6 , 300 gallons. Record how the rate was estimated (measured with a bucket and stopwatch, read from upstream flow meter data, or judged from reference photos) and how the start time was determined.

6. Prevent recurrence. Add the location to the hot-spot cleaning list, televise the line, enforce FOG rules or schedule rehabilitation.