Study guide

8.5 Meters, Water Loss Control, Asset Management & Customer Service

Alabama Water/Wastewater Operator Certification Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Alabama Regulations, Certification, Exams & Utility Administration

1.1 ADEM Division 335-10-1: Facility Classifications, Grades & Staffing Rules 1.2 Becoming Certified in Alabama: Exam Application, Operator Intern Status, Experience, Renewal & CEHs 1.3 Environmental Compliance, SDWA, Clean Water Act & NPDES Permits 1.4 Alabama's PSI-Delivered WPI Exams: Format, Grade Crosswalk & Need-to-Know Blueprints 1.5 ADEM Drinking-Water Operating Rules (Division 335-7): Control Tests, Residuals, Pressure, Cross-Connections & Records 1.6 Utility Administration: SOPs, Records, Security, Cybersecurity, Emergency Planning & Supervision

2 Chapter 2: Source Water, Wells, Coagulation, Filtration & Membranes

2.1 Source Water Hydrology, Groundwater vs. Surface Water & Protection 2.2 Coagulation Chemistry, Coagulants & Rapid Mixing Mechanics 2.3 Flocculation Basin Design, Clarification & Sedimentation 2.4 Granular Media Filtration, Head Loss & Backwash Protocols 2.5 Membrane Filtration: MF, UF, NF & RO Operation, Integrity Testing and Cleaning 2.6 Wells & Groundwater Systems: Construction, Pumps, Testing and Sanitary Protection (ADEM 335-7-5)

3 Chapter 3: Water Disinfection, Chemical Addition, Stabilization & Residuals

3.1 Chlorination Chemistry, Breakpoint Chlorination & Residuals 3.2 Disinfection Byproducts (DBPs), Stage 1/2 Rules & CT Compliance 3.3 Corrosion Control, Lead and Copper Rule & Fluoridation 3.4 Iron/Manganese Removal, Water Softening & Taste/Odor Control 3.5 Water Treatment Residuals: Sludge, Backwash Recycle & Plant Discharges

4 Chapter 4: Wastewater Preliminary & Primary Treatment

4.1 Wastewater Characteristics, Screening, Shredding & Grit Removal 4.2 Primary Sedimentation Basins, Scum Removal & Clarifier Performance

5 Chapter 5: Secondary Biological Treatment: Activated Sludge

5.1 Activated Sludge Microbiology, Basin Configurations & Aeration Systems 5.2 Process Control: F/M Ratio, MCRT/SRT & Sludge Settling Characteristics 5.3 Operational Troubleshooting (Bulking, Foaming, Pin Floc) & Process Modifications

6 Chapter 6: Fixed-Film Treatment, Lagoons, Nutrient Removal, Tertiary Filtration & Disinfection

6.1 Trickling Filters & Rotating Biological Contactors (RBCs) 6.2 Waste Stabilization Ponds, Aerated Lagoons & Alabama Grade I Lagoon Operations 6.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal 6.4 Tertiary Filtration & Membrane Bioreactors (MBRs) 6.5 Wastewater Disinfection & Dechlorination: Chlorine, UV and Ozone

7 Chapter 7: Sludge Treatment, Biosolids & Odor Control

7.1 Sludge Thickening, Aerobic Digestion & Anaerobic Digestion 7.2 Mechanical Dewatering, Polymer Conditioning & EPA 503 Biosolids Regulations 7.3 Odor Control & Wastewater Chemical Addition

8 Chapter 8: Water Distribution Systems, Installation, Metering & Water Loss

8.1 Distribution Piping Materials, Valves & Finished Water Storage Facilities 8.2 Water Main Flushing, Disinfection Protocols (AWWA C651) & Water Quality Maintenance 8.3 Distribution Hydraulics, Pressure Control & Cross-Connection Prevention 8.4 Main & Service Installation, Tapping, Repair and Utility Locating (Alabama 811) 8.5 Meters, Water Loss Control, Asset Management & Customer Service

9 Chapter 9: Wastewater Collection Systems, Lift Stations & Sewer Maintenance

9.1 Gravity Collection Networks, Manhole Construction & Self-Cleansing Velocity Standards 9.2 Wastewater Lift Stations, Submersible Pumps, Force Mains & Inflow/Infiltration (I&I) 9.3 Sewer Cleaning, CCTV Inspection & SSO Response

10 Chapter 10: Laboratory Procedures, Sampling & Environmental Compliance

10.1 Drinking Water Laboratory Analysis: Turbidity, pH, Alkalinity & Coliform Testing 10.2 Wastewater Laboratory Testing: BOD5, COD, Total Suspended Solids & Settleability 10.3 Representative Sampling Protocols, Preservation, Chain of Custody & QA/QC

11 Chapter 11: Plant Equipment, Pumps, Motors & Instrumentation

11.1 Centrifugal and Positive Displacement Pumps: Operation, Cavitation & Packing/Seals 11.2 Electric Motors, Variable Frequency Drives, Flow Meters & SCADA Systems

12 Chapter 12: Safety: Chemicals, Confined Spaces & Field Hazards

12.1 Chemical Safety: Chlorine Gas Emergency Handling (Kits A & B) & Hydrogen Sulfide (H2S) Hazards 12.2 Permit-Required Confined Space Entry, Lockout/Tagout (LOTO) & Personal Protective Equipment 12.3 Field Safety: Work-Zone Traffic Control, Electrical Hazards, Fall Protection & Hazard Communication

13 Chapter 13: Water & Wastewater Mathematics: Hydraulics, Chemical Feed & Pumping

13.1 Flow Conversions, Geometry, Tank Volume & Detention Time Calculations 13.2 The Pounds Formula, Chemical Feed Rates & Solution Concentration Calculations 13.3 Pumping Math: Total Dynamic Head, Horsepower, Efficiency & Power Cost

14 Chapter 14: Water & Wastewater Mathematics: Treatment Process Calculations

14.1 Clarifier Surface Overflow Rate, Weir Loading & Granular Filter Loading Rates 14.2 Biological Calculations: F/M Ratio, MCRT Solids Balance & Sludge Volume Index (SVI)

8.5 Meters, Water Loss Control, Asset Management & Customer Service

Key Takeaways Explain This Topic AI

Positive displacement meters suit residential low flows, turbine meters suit steady high flows, and compound meters combine both for widely varying demand.

Meter accuracy is the volume the meter registered divided by the actual volume, times 100; aging displacement meters usually under-register, especially at low flow.

In the AWWA water balance, non-revenue water equals unbilled authorized consumption plus apparent losses plus real losses.

Apparent losses are paper losses from customer meter inaccuracy, unauthorized use and data errors, while real losses are physical leakage and overflows.

ADEM's monthly operating report can require water loss information, and tank and valve maintenance programs feed directly into asset management.

Last updated: October 2026

8.5 Meters, Water Loss Control, Asset Management & Customer Service

The WPI Water Distribution Class I outline lists metering and related equipment (remote readers, meter replacements) , conducting meter reading , implementing a water loss control program , understanding elements of an asset management program , maintaining an up-to-date map (GIS) and addressing customer inquiries . These tasks keep revenue flowing and reveal problems in the system. ADEM's monthly operating report rule (335-7-10-.06) also lets the Department require water production records, distribution pressure measurements and water loss information .

Meter Types

Meter How it works Best use Weakness

Positive displacement (nutating disc or oscillating piston) Each cycle passes a fixed volume Residential and small commercial (5/8 to 2 inch) Wears and under-registers with age; can be damaged by sand

  • Multi-jet and single-jet Jets turn an impeller Small services Accuracy drifts with wear
  • Turbine Flow spins a rotor Large, steady flows (irrigation, industry) Poor accuracy at low flow

Compound Turbine for high flow plus a small displacement meter for low flow Schools, apartments, hospitals with widely varying demand More parts to maintain

Electromagnetic and ultrasonic (static) No moving parts Large mains and new residential AMI meters Need power or batteries and correct installation

Fire service and detector check Measure or detect flow on fire lines Private fire lines Must not restrict fire flow

Reading Meters

Registers read in gallons or cubic feet ; 1 ccf (100 cubic feet) equals 748 gallons . Check for a multiplier on the register face.

The low-flow (leak) indicator turns with very small flows. If it moves when every fixture is off, there is a leak on the customer side.

AMR (automatic meter reading) collects reads by drive-by radio; AMI (advanced metering infrastructure) uses a fixed two-way network to deliver hourly or more frequent reads with leak, tamper and reverse-flow alerts.

Example. Last month's read was 4,832 (ccf register) and this month's is 4,846. Use is 14 ccf, or 14 × 748 = 10,472 14 \times 748 = 10{,}472 14 × 748 = 10 , 472 gallons.

Meter Accuracy and Testing Accuracy (%) = Volume registered by meter Actual volume through meter × 100 \text{Accuracy (\%)} = \frac{\text{Volume registered by meter}}{\text{Actual volume through meter}} \times 100 Accuracy (%) = Actual volume through meter Volume registered by meter ​ × 100

If 10.0 gallons pass through a meter into a calibrated test tank and the meter registers 9.6 gallons, accuracy is 96.0 percent and the meter under-registers by 4 percent, which is lost revenue. AWWA standards expect new displacement meters to read within roughly 98.5 to 101.5 percent at normal test flows, with wider tolerance at minimum flow. Large meters should be tested in place on a schedule because a small error on a large meter costs more than many small-meter errors. Replace meters on a planned program rather than only when they stop.

The Water Balance and Non-Revenue Water

AWWA Manual M36 organizes the annual water audit:

  • Component Includes
  • System input volume Water produced or purchased, corrected for source meter error

Authorized consumption Billed metered, billed unmetered, unbilled metered (for example, metered city buildings) and unbilled unmetered (firefighting, flushing)

Apparent losses Customer meter under-registration, unauthorized consumption (theft, illegal connections) and systematic data-handling errors

Real losses Leakage on mains and service lines and storage-tank overflows Non-revenue water = Unbilled authorized + Apparent losses + Real losses \text{Non-revenue water} = \text{Unbilled authorized} + \text{Apparent losses} + \text{Real losses} Non-revenue water = Unbilled authorized + Apparent losses + Real losses

Example. A system's input is 120 MG per year. Billed authorized consumption is 98 MG and unbilled authorized is 2 MG, so water losses are 20 MG. If apparent losses are estimated at 4 MG, real losses are 16 MG. Non-revenue water is 2 + 20 = 22 2 + 20 = 22 2 + 20 = 22 MG, or 22 ÷ 120 × 100 = 18.3 22 \div 120 \times 100 = 18.3 22 ÷ 120 × 100 = 18.3 percent of input. The Infrastructure Leakage Index (ILI) compares current real losses with the unavoidable minimum for the system's size and pressure; a lower ILI is better.

Finding and Reducing Leaks

Acoustic listening on valves and hydrants, leak noise correlators and permanent noise loggers locate hidden leaks.

Night-flow analysis in metered district areas shows leakage when legitimate use is lowest.

Pressure management with pressure-reducing valves lowers leakage and break frequency in high-pressure zones.

Repair leaks quickly; the volume lost depends on how long a leak runs as much as on its size.

Storage overflows are real losses; fix altitude valves and level controls.

Asset Management

Asset management means knowing what you own, its condition, its risk and its life-cycle cost , then planning repair and replacement to deliver an agreed level of service at the lowest cost.

Inventory every main, valve, hydrant, meter, tank and pump in GIS, with size, material, age and location. Tie valves and fittings to permanent landmarks.

Assess condition with break history, inspections and test results.

Rank risk as likelihood of failure times consequence of failure; a transmission main under a hospital ranks higher than a 2-inch main on a dead end.

Plan maintenance, rehabilitation and replacement in a capital improvement plan with funding.

Track work in a computerized maintenance management system (CMMS) .

Valve and hydrant programs are core asset management. Exercise valves on a schedule (critical valves more often), recording turns, direction, condition and location; operate and maintain hydrants at least annually (Section 8.2).

ADEM's storage tank rule (335-7-7-.04) is an asset management requirement too: each system must keep a written tank maintenance plan with an inspection and cleaning schedule not to exceed five years (Section 8.1).

Customer Inquiries

Pressure complaints : check nearby pressure readings, recent valve work and the customer's pressure-reducing valve or meter strainer.

Discolored water : often follows flushing, main breaks or valve operation; flush the main and advise the customer to run cold water.

Taste and odor : check chlorine residual and recent changes; consider the customer's plumbing and water heater.

High bills : re-read the meter, check the leak indicator, look for running toilets (dye test) and irrigation leaks, and test the meter if the customer requests it.

Record every complaint with date, location, type and action taken, and keep the file for three years (Rule 335-7-10-.05).