Study guide

2.3 Galvanic Series & Electromotive Force (EMF) Series

AMPP CP1 Cathodic Protection Tester Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Introduction & CP Exam Overview

About the AMPP CP1 Tester Exam & Certification Path How to Study for CP1 & Navigate This Guide Corrosion Science & Industry Terminology Glossary Field Mathematics & Ohm's Law Fundamentals AMPP Ethics for the Corrosion Professional

2 Chapter 2: Fundamentals of Electrochemistry & Corrosion Cells

2.1 The Corrosion Cell: Anode, Cathode, Electrolyte & Metallic Path 2.2 Anodic & Cathodic Reactions on Carbon Steel 2.3 Galvanic Series & Electromotive Force (EMF) Series 2.4 Forms of Corrosion: Uniform, Galvanic, Pitting & Crevice 2.5 Factors Affecting Corrosion Rates: Oxygen, pH, Temperature & Flow

3 Chapter 3: Principles of Cathodic Protection

3.1 Cathodic Protection Theory & Mixed-Potential Diagrams 3.2 Galvanic (Sacrificial Anode) CP Systems 3.3 Impressed Current Cathodic Protection (ICCP) Systems 3.4 Sacrificial Anode Materials: Mg, Zn, & Al Alloys 3.5 ICCP Anode Materials: MMO, Graphite, HSCI, & Platinum

4 Chapter 4: Electrical Circuit Analysis for CP

4.1 Ohm's Law Applications in CP Circuits 4.2 Series & Parallel Resistance in CP Groundbeds & Piping 4.3 Kirchhoff's Voltage & Current Laws in Network Piping 4.4 Shunts: Types, Ratings & Current Calculations 4.5 Rectifier Operation & Transformer Tap Adjustments

5 Chapter 5: Reference Electrodes & Half-Cell Potentials

5.1 Copper/Copper Sulfate (CSE) Reference Electrode Construction & Maintenance 5.2 Silver/Silver Chloride (Ag/AgCl) & Zinc Reference Electrodes 5.3 Converting Potentials Between Reference Electrodes 5.4 Reference Electrode Care, Temperature Correction & Contamination Checks 5.5 High-Impedance Voltmeters & Contact Resistance Errors

6 Chapter 6: Field Measurement & Potential Criteria

6.1 Structure-to-Electrolyte Potential Measurement Procedures 6.2 The -850 mV CSE Polarized Criterion (NACE SP0169) 6.3 The 100 mV Polarization Decay Criterion 6.4 Understanding IR Drop & The Instant-Off Interruption Technique 6.5 Native, On, Polarized, & Off Potentials Comparison

7 Chapter 7: Advanced Field Survey Techniques

Soil Resistivity Testing: Wenner 4-Pin Method (ASTM G57) Soil Pin Spacing, Layering & Corrosivity Classification Close Interval Potential Surveys (CIPS) Direct Current Voltage Gradient (DCVG) Coating Fault Surveys Cathodic Protection Coupons for IR-Free Potential Measurements

8 Chapter 8: Test Stations, Isolation & Stray Current

8.1 Test Station Types, Lead Wires & Commissioning Inspection 8.2 Electrical Isolation Joints & Dielectric Flange Testing 8.3 Casing Isolation & Shorted Casing Testing 8.4 DC Stray Current Interference: Detection & Mitigation 8.5 AC Stray Current Interference & Induction Hazards (NACE SP0177)

9 Chapter 9: Industry Standards & Field Documentation

9.1 NACE SP0169: External Corrosion Control Overview 9.2 NACE TM0497: Measurement Techniques Standard 9.3 Regulatory Compliance: PHMSA, DOT, & EPA Requirements 9.4 CP Data Collection, Logging & Quality Assurance 9.5 Rectifier Maintenance & Routine Inspection Logs 9.6 Anode Groundbed Testing & Resistance Measurements

10 Chapter 10: Electrical & Operational Safety for CP Personnel

10.1 Rectifier Electrical Safety, Lockout/Tagout (LOTO) & NFPA 70E 10.2 AC Induction Hazards Near High-Voltage Power Lines 10.3 Hazardous Atmospheres & Confined Space Safety at Test Vaults 10.4 Personal Protective Equipment (PPE) & Arc Flash Protection 10.5 Excavation, Trenching & Underground Utility Location (811) 10.6 Stop-Work Authority & Emergency Response Procedures

2.3 Galvanic Series & Electromotive Force (EMF) Series

Key Takeaways Explain This Topic AI

The EMF Series lists pure metals under standard laboratory conditions based on their standard electrode potentials.

The Galvanic Series lists metals and commercial alloys in a specific, practical electrolyte (like seawater) based on their relative activity.

More active (electronegative) metals act as anodes and corrode when coupled with more noble (electropositive) metals.

Metals at the bottom of the Galvanic Series are noble (cathodic), while metals at the top are active (anodic).

The potential difference between two metals in a specific environment determines the driving voltage for a galvanic corrosion cell.

Last updated: July 2026

  • Galvanic Series & Electromotive Force (EMF) Series
  • Predicting Galvanic Corrosion

When two different metals are electrically connected and immersed in a common electrolyte, a galvanic corrosion cell is formed. One metal will become the anode and corrode faster than it would alone, while the other will become the cathode and corrode slower (or not at all). To predict which metal will act as the anode and which will act as the cathode, corrosion professionals rely on organized lists of metals based on their electrochemical activity. The two most common lists are the Electromotive Force (EMF) Series and the Galvanic Series.

Understanding the difference between these two series and how to apply them is a core competency for CP personnel, as the principles of the Galvanic Series govern the operation of galvanic (sacrificial) anode cathodic protection systems.

The Electromotive Force (EMF) Series

The EMF Series is a theoretical, thermodynamically derived list of pure elements arranged according to their standard electrode potentials.

To create the EMF Series, scientists measure the potential of a pure metal in a solution containing its own ions at an activity of 1.0 (a very specific, standard concentration), at a standard temperature of 25°C. These potentials are measured relative to a Standard Hydrogen Electrode (SHE), which is arbitrarily assigned a potential of 0.000 Volts.

In the EMF Series:

Elements with a more negative standard potential (e.g., Magnesium, Zinc) are considered more active or anodic.

Elements with a more positive standard potential (e.g., Gold, Platinum) are considered more noble or cathodic.

If two pure elements are coupled under these standard conditions, the one with the more negative potential will be the anode.

While the EMF Series provides the fundamental thermodynamic basis for corrosion, it has limited practical application in the field. This is because:

Engineers rarely use pure metals; they use alloys (like carbon steel, stainless steel, brass).

Real-world electrolytes (soil, seawater) are rarely standard solutions of the metal's own ions at unit activity.

Surface conditions, such as oxide films and passive layers, significantly alter a metal's potential in the real world.

The Galvanic Series

To address the limitations of the EMF Series, practical corrosion engineers developed the Galvanic Series .

The Galvanic Series is an empirical list of metals and commercial alloys arranged according to their measured corrosion potentials in a specific, real-world electrolyte . The most common and widely published Galvanic Series is based on flowing seawater at ambient temperature.

In a Galvanic Series (such as the one for seawater):

The metals at the top of the list (most negative potentials) are the most active and will act as anodes .

The metals at the bottom of the list (most positive potentials) are the most noble and will act as cathodes .

When any two metals on the list are electrically connected in that specific electrolyte, the one higher on the list will become the anode and corrode, protecting the one lower on the list.

Key Differences from the EMF Series

Alloys are Included: The Galvanic Series includes common construction materials like Type 304 Stainless Steel, Monel, and various bronzes, which do not appear on the EMF Series.

Environment Specific: There is no single Galvanic Series. There is a Galvanic Series for seawater, one for brackish water, one for specific soils, etc. A metal's relative position can change depending on the environment.

Active/Passive States: Some alloys, notably stainless steels, can exhibit two very different potentials depending on whether their protective oxide film is intact (Passive) or broken down (Active). The Galvanic Series often lists these alloys twice to reflect these two states.

Using the Galvanic Series in Practice

The Galvanic Series is an invaluable tool for preventing galvanic corrosion and for designing cathodic protection systems.

1. Avoiding Galvanic Corrosion

When designing a system, engineers use the Galvanic Series to select materials that are close to each other on the list. The closer two metals are in the series, the smaller the potential difference between them, and the weaker the galvanic corrosion cell will be.

For example, if you must connect a brass valve to a pipeline, connecting it to a copper pipe (close in the series) is much safer than connecting it directly to a carbon steel pipe (far apart in the series). If widely separated metals must be used, they should be electrically isolated using dielectric insulating kits to break the metallic path of the corrosion cell.

2. Designing Cathodic Protection Systems

The principles of the Galvanic Series are the foundation of galvanic (sacrificial) anode CP systems. To protect a carbon steel pipeline, we must connect it to a metal that is significantly more active (higher) on the Galvanic Series.

Looking at a typical Galvanic Series for soils or seawater:

  • Magnesium (Mg)
  • Zinc (Zn)
  • Aluminum (Al) Alloys
  • Carbon Steel
  • Copper (Cu)

Because Magnesium, Zinc, and Aluminum are higher on the list than Carbon Steel, they will act as anodes when connected to the steel. They will sacrifice themselves (corrode) to supply electrons to the steel, forcing the steel to become the cathode. This is why we use Mg, Zn, or Al as sacrificial anodes to protect carbon steel structures. If we mistakenly connected copper to the steel, the steel would be higher on the list, becoming the anode and corroding faster to protect the copper.

  • Feature EMF Series Galvanic Series
  • Materials Pure Elements Only Pure Metals and Commercial Alloys
  • Environment Standard Solutions (unit activity) Specific Practical Electrolyte (e.g., seawater)
  • Utility Theoretical, Thermodynamic basis Practical, engineering applications
  • Status Fixed values based on thermodynamics Empirical values, can change with environment

When reviewing a Galvanic Series chart, the distance between two metals indicates the potential driving voltage. A larger separation means a higher driving voltage and a potentially higher galvanic corrosion rate if the two metals are coupled.