Study guide

6.1 Phlebotomy Terminology and Equipment

AMT Certified Medical Laboratory Assistant CMLA

Track your progress as you read

Finished sections get a check mark.

1 Introduction

1.1 Current Exam Facts 1.2 Blueprint Weights and Study Strategy

2 Chapter 2: Safety Terminology and Infection Control

2.1 Safety, Infection, and OSHA Terminology 2.2 Chain of Infection and Precautions 2.3 Isolation, Aseptic Technique, and Disease Prevention

3 Chapter 3: OSHA, HazCom, and Public-Health Reporting

3.1 OSHA Bloodborne Pathogens and Needlestick Safety 3.2 Hazard Communication, SDS, and GHS 3.3 Mandated Safety Rules and Public-Health Reporting

4 Chapter 4: Quality Assessment and Quality Control

4.1 Quality Control and Assessment Terminology 4.2 QC vs QA, Internal vs External QC, and Proficiency Testing 4.3 Daily QC, Temperature Logs, and Corrective Action 4.4 Instrument Maintenance and Calibration in CMLA Scope

5 Chapter 5: Waived-Test Integrity and Confirmatory Testing

5.1 Off-Label Waived Testing and High-Complexity Default 5.2 Following Manufacturer Instructions for Waived Tests 5.3 Confirmatory and Supplemental Testing

6 Chapter 6: Phlebotomy Foundations

6.1 Phlebotomy Terminology and Equipment 6.2 Serum, Plasma, Whole Blood, and Anticoagulation 6.3 Patient Identification and Container Identification

7 Chapter 7: Venipuncture, Order of Draw, and Specimen Integrity

7.1 Patient Preparation and Physiologic Effects 7.2 Vein Selection and Venipuncture Technique 7.3 Order of Draw and Tube Additives 7.4 Short Draws, Hemolysis, and Plasma-on-Cells Limits

8 Chapter 8: Capillary Collection, Processing, and Legal Specimens

8.1 Capillary Puncture Including Infants 8.2 Post-Care, Labeling, Transport, Processing, and Send-Outs 8.3 Specimens Used as Legal Evidence

9 Chapter 9: Non-Blood Collection and Preanalytical Errors

9.1 Urine Collection Types and Patient Instruction 9.2 Urine Suitability, Storage, Preservatives, and Rejection 9.3 Other Specimens and Time/Temperature Requirements 9.4 Shipping, Slide Prep, Preanalytical Errors, and Complications

10 Chapter 10: Clinical Chemistry

10.1 Clinical Chemistry Terminology and Test Families 10.2 Chemistry Instrumentation, Cleaning, and Maintenance 10.3 Point-of-Care and Waived Chemistry Testing 10.4 Toxicology Within CMLA Scope

11 Chapter 11: Hematology and Coagulation

11.1 Hematology Terminology, Blood Functions, and Cell Types 11.2 Hematology Instrumentation, QC, and Calibration 11.3 Coagulation: PT, PTT, INR, Heparin, and Warfarin 11.4 Point-of-Care and Waived Hematology Tests

12 Chapter 12: Immunology, Serology, and Immunohematology

12.1 Antigen-Antibody Principles 12.2 Blood Types, Rh, and Immunohematology Basics 12.3 Waived Immunology, Serology, and Immunohematology Procedures

13 Chapter 13: Microbiology

13.1 Microbiology Terminology and Specimen Appropriateness 13.2 Aseptic Processing, Storage, and Transport of Micro Specimens 13.3 Media, Cultures, and Procedure Matching 13.4 Stains, KOH, Wet Preps, Reagents, and Controls

14 Chapter 14: Urinalysis and Microscopy

14.1 Urinalysis Terminology 14.2 Waived Urinalysis Procedures and Specimen Handling 14.3 Microscopy Parts, Magnification, Wet Prep, and Cleaning

15 Chapter 15: Basic Anatomy and Physiology

15.1 Anatomy Relevant to Laboratory Testing 15.2 Physiology Relevant to Laboratory Testing

16 Chapter 16: Legal, Ethical, and HIPAA Foundations

16.1 Consent, ABN, Test Ordering, and PPM Restrictions 16.2 Patient's Bill of Rights, Refusal, and Medicolegal Risk 16.3 Professional Appearance, Conduct, and Social Media 16.4 HIPAA Confidentiality and Record Release

17 Chapter 17: Clerical Skills, Communication, and Critical Values

17.1 Reports, Abnormal Results, and Critical-Value Notification 17.2 HIT Data, Inventory, Expirations, and Billing/Coding 17.3 Patient Instruction, Communication, Telephone, and Time Management

6.1 Phlebotomy Terminology and Equipment

Key Takeaways Explain This Topic AI

CLSI PRE02, Collection of diagnostic venous blood specimens, 8th edition (2025), is the current venous-collection standard and the successor to GP41.

Petechiae are pinpoint capillary hemorrhages, often from a tight or prolonged tourniquet; a hematoma is a raised collection of blood in tissue after vessel leakage.

An adapter (tube holder) seats an evacuated tube on a double-ended needle; a transfer device moves syringe blood into tubes without exposing a sharp.

A butterfly (winged infusion set) is for small, fragile, or difficult veins; a syringe is for veins that would collapse under evacuated-tube vacuum.

Pulse at a proposed puncture site indicates an artery; routine CMLA collections are venous or capillary, not arterial.

Last updated: August 2026

CMLA Work Area II (Preexamination / Preanalytical Considerations) is 36 items, or 18.0% of the 200-question exam. Phlebotomy is competency 3. Before vein selection, order of draw, or hemolysis (Chapter 7), you must define the tools and patient events AMT lists under II.3.A.1: tourniquet , lancet , safety needle , evacuated tube , adapter , syringe , butterfly , safety lancet , hematoma , petechiae , pulse , syncope , seizure , vein/venous , capillary , artery/arterial , serum , plasma , whole blood , anticoagulant , preservative , and transfer device .

The current Clinical and Laboratory Standards Institute (CLSI) document for venous collection is CLSI PRE02 , Collection of diagnostic venous blood specimens , 8th edition (2025). PRE02 succeeds the older GP41 guideline. AMT CMLA-REF-2025-1 also lists the PRE02 quick guide (PRE02QG) and, for identification, CLSI PRE01 . Capillary collection remains GP42 ; handling and transport is PRE04 . If a stem asks for the current venous-collection standard, the answer is PRE02, not GP41.

Quick Answer: Name each device by its job. An adapter holds an evacuated tube on a double-ended needle; a transfer device moves syringe blood into tubes. A butterfly is for small or difficult veins; a syringe is for veins that collapse under vacuum. Petechiae are pinpoint spots; a hematoma is a raised leak. Pulse at the site means artery, not a strong vein.

Evacuated-tube system: tube, adapter, and safety needle

An evacuated tube is a sterile, closed collection tube manufactured with a measured vacuum so it fills to a predetermined volume when the stopper is pierced. Color-coded stoppers identify the additive (or the absence of one). The vacuum is a design feature, not a guarantee: an expired, cracked, or previously opened tube can lose vacuum and underfill. Underfilled additive tubes change the blood-to-additive ratio; that integrity problem is expanded in Chapter 7.

An adapter (tube holder or hub) is the barrel that seats the evacuated tube against a double-ended needle. One end of the needle enters the vein; the sheathed back end punctures the tube stopper. Do not strip the back-end sleeve off to make the tube fill faster. The adapter is single-patient equipment. It is not a tourniquet, and it is not a transfer device.

A safety needle is a venipuncture needle with engineered sharps-injury protection (retractable cannula or hinged shield). OSHA's Bloodborne Pathogens Standard (29 CFR 1910.1030) and the Needlestick Safety and Prevention Act require safer devices when they are available and effective. Activate the safety feature immediately after the needle leaves the patient, then discard needle and adapter as a unit into a puncture-resistant sharps container. Walking with an unshielded used needle, or using a non-safety needle when a safety device is in the drawer, is the terminology failure applied.

Syringe, butterfly, and transfer device

A syringe is a barrel-and-plunger device used when vacuum might collapse a small or fragile vein, when fill rate must be controlled by hand, or when an evacuated-tube assembly cannot be used. Blood in a syringe is still a specimen. You never two-hand recap, and you never push an exposed needle through a tube stopper to fill tubes.

A transfer device (blood-transfer device) is a needleless or sheathed adapter that lets you fill evacuated tubes from a syringe without exposing a sharp. CLSI PRE02 and OSHA expect this device whenever syringe blood is moved into tubes. Forcing blood in with the plunger overpressurizes the tube, hemolyzes cells, and defeats the vacuum. The transfer device and the evacuated-tube adapter look similar in a supply bin; they are not interchangeable names on CMLA.

A butterfly (winged infusion set) is a short needle with flexible tubing and plastic wings. Use it for small or difficult veins (dorsal hand, pediatrics, oncology, scarred antecubital veins) when you need finer control of angle and depth, or when the patient cannot tolerate a standard straight needle. A butterfly can attach to an adapter for evacuated tubes or to a syringe. It is not the default for every healthy adult antecubital draw. Extra tubing increases the chance of underfilled coagulation tubes (air in the line occupies volume) and of needlesticks if the safety feature is not activated. The CMLA trap is butterfly versus syringe: choose a butterfly for control on a small vein ; choose a syringe when vacuum would collapse the vein . Neither device replaces a transfer device after a syringe fill.

Device What it is Typical CMLA use Classic trap

Evacuated tube plus adapter Vacuum tube seated in a holder Routine venous draws Expired or under-vacuum tube; calling the holder a transfer device

Safety needle Needle with engineered shield or retraction Every venipuncture when available Walking with an unshielded used needle

Butterfly (winged set) Short needle, tubing, wings Small, fragile, or hand veins; finer control Using it for every adult draw; underfilling citrate tubes

Syringe Plunger-controlled draw Veins that collapse under vacuum Recapping or needle-puncturing a tube stopper

Transfer device Needleless or sheathed syringe-to-tube adapter Moving syringe blood into tubes Pushing the plunger to speed fill

Lancet and safety lancet

A lancet is a capillary-puncture device that makes a controlled skin incision for fingerstick or heelstick collection. A safety lancet is a single-use lancet whose blade or needle retracts permanently so it cannot be reused and cannot stay exposed. OSHA treats used lancets as contaminated sharps. Depth is selected by choosing the correct device, not by guessing how hard to press: adult fingerstick devices and infant heel devices are not interchangeable. Full capillary technique, including infants, belongs in Chapter 8; here you need the names, the single-use rule, and the fact that a safety lancet is not a venipuncture safety needle.

Tourniquet

A tourniquet is a band applied around the arm to slow venous return so veins fill and become visible or palpable. It is a venous-distention tool, not an arterial clamp and not a standing order to leave the arm purple. Apply it 3–4 inches above the site. CLSI venous-collection practice limits tourniquet time (classically about one minute) because longer application concentrates cells and proteins ( hemoconcentration ) and can produce petechiae . Release it once blood flow is established. A tourniquet tight enough to abolish the distal pulse is too tight. Leaving it on while you walk away to find tubes is both a quality error and a patient-safety error.

Vein, capillary, artery, and pulse

A vein ( venous blood) carries blood toward the heart. Superficial veins of the antecubital fossa (median cubital, cephalic, basilic) and dorsal hand veins are the routine phlebotomy targets. Veins do not pulsate. Palpate for a bouncy, resilient cord, not for a beat.

A capillary is the microscopic vessel between arterioles and venules. Capillary blood is a mixture of arterial blood, venous blood, and interstitial fluid. Fingerstick and heelstick specimens are capillary, not venous. Do not report a fingerstick as a venipuncture specimen.

An artery ( arterial blood) carries blood away from the heart and pulses . Pulse is the palpable arterial expansion with each heartbeat. Feeling a pulse at a proposed puncture site means you are on or next to an artery, not a strong vein. Routine CMLA collections are venous or capillary. Arterial puncture for blood gases is a specialized procedure outside ordinary assistant venipuncture. If bright-red blood pulses into the tube or a hematoma expands rapidly, treat it as possible arterial involvement: remove the needle, apply firm prolonged pressure per policy, and do not relabel the event as a normal venous draw.

Hematoma, petechiae, syncope, and seizure

A hematoma is a raised collection of blood in the tissue after leakage from a vessel. Causes include going through the vein, failing to apply pressure after withdrawal, probing, or puncturing an artery. It looks and feels like a swelling bruise forming under the skin.

Petechiae are pinpoint, non-raised red or purple spots from capillary leakage. A tight or prolonged tourniquet, thrombocytopenia, or fragile capillaries can produce them. Petechiae are not miniature hematomas. On CMLA this pair is a designed trap: hematoma = pooled blood in tissue; petechiae = pinpoint capillary hemorrhages, often on the forearm below a tourniquet.

Syncope is fainting—transient loss of consciousness from decreased cerebral blood flow. Warning signs include dizziness, nausea, sweating, pallor, or a sudden feeling of warmth. If syncope begins, remove the needle, protect the patient from a fall (lower the head, do not prop an unconscious patient on the chair edge), and follow facility first-aid policy. Do not keep filling tubes while the patient is losing consciousness.

A seizure is abnormal electrical brain activity with involuntary movement or altered awareness. Remove the needle immediately, do not restrain the limbs, clear nearby objects, and call for help. Do not put anything in the mouth. Document and report. Do not finish the draw during a seizure.

Serum, plasma, whole blood, anticoagulant, and preservative (names)

Whole blood is blood as drawn, with cells still suspended in the liquid. Plasma is the liquid portion of anticoagulated blood. Serum is the liquid left after blood has clotted . An anticoagulant prevents clotting (EDTA, citrate, heparin, oxalate). A preservative protects an analyte after collection; sodium fluoride as a glycolytic inhibitor, usually paired with an oxalate anticoagulant in a gray-top tube, is the classic example. Section 6.2 is the chemistry of these five words. II.3.A.1 only requires that you not treat serum and plasma as synonyms and not call every additive an anticoagulant.

Exam traps

Petechiae are not small hematomas; hematomas are not petechiae.

A butterfly is not automatically better than a straight safety needle; a syringe is not a substitute for a transfer device.

Pulse at the site means artery, not a strong vein.

PRE02 (2025), not GP41, is the current venous-collection standard; PRE01 is identification; GP42 is capillary.

An adapter holds the tube; a transfer device moves syringe blood. They are not the same part.

A safety lancet is a capillary device; a safety needle is a venipuncture device.

When CMLA shows a device or a complication word, define it in one sentence, name when you would choose it, and name the look-alike it is not.