Study guide
14.1 Urinalysis Terminology
AMT Certified Medical Laboratory Assistant CMLA
Track your progress as you read
Finished sections get a check mark.
1 Introduction
1.1 Current Exam Facts 1.2 Blueprint Weights and Study Strategy
2 Chapter 2: Safety Terminology and Infection Control
2.1 Safety, Infection, and OSHA Terminology 2.2 Chain of Infection and Precautions 2.3 Isolation, Aseptic Technique, and Disease Prevention
3 Chapter 3: OSHA, HazCom, and Public-Health Reporting
3.1 OSHA Bloodborne Pathogens and Needlestick Safety 3.2 Hazard Communication, SDS, and GHS 3.3 Mandated Safety Rules and Public-Health Reporting
4 Chapter 4: Quality Assessment and Quality Control
4.1 Quality Control and Assessment Terminology 4.2 QC vs QA, Internal vs External QC, and Proficiency Testing 4.3 Daily QC, Temperature Logs, and Corrective Action 4.4 Instrument Maintenance and Calibration in CMLA Scope
5 Chapter 5: Waived-Test Integrity and Confirmatory Testing
5.1 Off-Label Waived Testing and High-Complexity Default 5.2 Following Manufacturer Instructions for Waived Tests 5.3 Confirmatory and Supplemental Testing
6 Chapter 6: Phlebotomy Foundations
6.1 Phlebotomy Terminology and Equipment 6.2 Serum, Plasma, Whole Blood, and Anticoagulation 6.3 Patient Identification and Container Identification
7 Chapter 7: Venipuncture, Order of Draw, and Specimen Integrity
7.1 Patient Preparation and Physiologic Effects 7.2 Vein Selection and Venipuncture Technique 7.3 Order of Draw and Tube Additives 7.4 Short Draws, Hemolysis, and Plasma-on-Cells Limits
8 Chapter 8: Capillary Collection, Processing, and Legal Specimens
8.1 Capillary Puncture Including Infants 8.2 Post-Care, Labeling, Transport, Processing, and Send-Outs 8.3 Specimens Used as Legal Evidence
9 Chapter 9: Non-Blood Collection and Preanalytical Errors
9.1 Urine Collection Types and Patient Instruction 9.2 Urine Suitability, Storage, Preservatives, and Rejection 9.3 Other Specimens and Time/Temperature Requirements 9.4 Shipping, Slide Prep, Preanalytical Errors, and Complications
10 Chapter 10: Clinical Chemistry
10.1 Clinical Chemistry Terminology and Test Families 10.2 Chemistry Instrumentation, Cleaning, and Maintenance 10.3 Point-of-Care and Waived Chemistry Testing 10.4 Toxicology Within CMLA Scope
11 Chapter 11: Hematology and Coagulation
11.1 Hematology Terminology, Blood Functions, and Cell Types 11.2 Hematology Instrumentation, QC, and Calibration 11.3 Coagulation: PT, PTT, INR, Heparin, and Warfarin 11.4 Point-of-Care and Waived Hematology Tests
12 Chapter 12: Immunology, Serology, and Immunohematology
12.1 Antigen-Antibody Principles 12.2 Blood Types, Rh, and Immunohematology Basics 12.3 Waived Immunology, Serology, and Immunohematology Procedures
13 Chapter 13: Microbiology
13.1 Microbiology Terminology and Specimen Appropriateness 13.2 Aseptic Processing, Storage, and Transport of Micro Specimens 13.3 Media, Cultures, and Procedure Matching 13.4 Stains, KOH, Wet Preps, Reagents, and Controls
14 Chapter 14: Urinalysis and Microscopy
14.1 Urinalysis Terminology 14.2 Waived Urinalysis Procedures and Specimen Handling 14.3 Microscopy Parts, Magnification, Wet Prep, and Cleaning
15 Chapter 15: Basic Anatomy and Physiology
15.1 Anatomy Relevant to Laboratory Testing 15.2 Physiology Relevant to Laboratory Testing
16 Chapter 16: Legal, Ethical, and HIPAA Foundations
16.1 Consent, ABN, Test Ordering, and PPM Restrictions 16.2 Patient's Bill of Rights, Refusal, and Medicolegal Risk 16.3 Professional Appearance, Conduct, and Social Media 16.4 HIPAA Confidentiality and Record Release
17 Chapter 17: Clerical Skills, Communication, and Critical Values
17.1 Reports, Abnormal Results, and Critical-Value Notification 17.2 HIT Data, Inventory, Expirations, and Billing/Coding 17.3 Patient Instruction, Communication, Telephone, and Time Management
14.1 Urinalysis Terminology
Key Takeaways Explain This Topic AI
Random, midstream, and clean-catch are not synonyms: random is any single void, midstream is a portion, and clean-catch adds periurethral cleansing plus a sterile cup, usually for culture and sensitivity (AMT III.9.A.1).
Macroscopic urinalysis is physical appearance plus chemical reagent-strip analyses; microscopic urinalysis is examination of sediment formed elements.
Specific gravity estimates concentration versus water (1.000); a refractometer measures refractive index, and the dipstick specific-gravity pad is only an estimate.
Casts are cylindrical Tamm-Horsfall (uromodulin) protein molds formed in tubules; crystals are precipitated salts; skin contaminants and artifacts are extra-urinary material, not infection.
Pyuria, hematuria, glycosuria, and proteinuria name white cells, blood, glucose, and protein in urine; none of those chemical findings is a culture and sensitivity (C&S) result.
Last updated: August 2026
CMLA Work Area III (Examination / Analytical Considerations) is 83 items, or 41.5% of the 200-question exam. Urinalysis (UA) is competency 9 . AMT III.9.A.1 is a terminology list: collection types, physical and chemical findings, and formed elements in sediment . Chapter 9 already taught how to instruct a patient. This section is the language you use when you look at the cup and the report. A Certified Medical Laboratory Assistant (CMLA) who can define each word can stop a look-alike trap before it is reported.
Quick Answer: Random , midstream , and clean-catch are not synonyms. Macroscopic UA is what you see plus chemical analyses (the reagent strip). Microscopic UA is the sediment . Specific gravity (SG) is concentration; a refractometer measures it. Pyuria is white cells; hematuria is blood; glycosuria is glucose; proteinuria is protein; polyuria is high volume. Casts form in tubules; crystals precipitate in urine; a skin contaminant is not infection. A dipstick is not culture and sensitivity (C&S) .
Collection terms in UA language
Random urine is a single void at any time, without a timed start or stop. It is the usual specimen for a routine screen. Random does not mean dirty, and it does not mean midstream.
Midstream means the patient starts in the toilet, catches the middle portion, and finishes in the toilet. The first urine flushes distal urethral organisms and debris.
Clean-catch adds periurethral cleansing and a sterile cup, usually with midstream collection, so the specimen can support C&S . Clean-catch is a method, not a color. A random hat is not a culture specimen.
Timed collections—including 2-hour , 12-hour , and 24-hour —save all urine in a defined clock window. The complete volume is the specimen. Discard the first void, save every later void including the stop-time void, and send the entire jug (Chapter 9). In UA language, timed is not “a cup labeled 24-hour.”
Macroscopic versus microscopic
Macroscopic UA is the physical examination (color, clarity, sometimes odor and volume) plus chemical analyses on a reagent strip. You do not need a microscope for the strip. Color (straw, yellow, amber, red, brown, orange from phenazopyridine) and clarity (clear, hazy, cloudy, turbid) still belong on the report.
Microscopic UA is examination of sediment —the concentrated formed elements after centrifugation, or an equivalent automated particle method the laboratory validates. Cells, casts, crystals, organisms, mucus, spermatozoa, and junk live here.
Chemical analyses are the pad reactions: glucose, protein, blood, leukocyte esterase, nitrite, ketones, pH, SG, urobilinogen, and bilirubin (Section 14.2). They are screening chemistry, not a culture and not a species identification.
Confirmatory tests are follow-up methods the instructions for use (IFU) or standard operating procedure (SOP) require when a screen is positive or when the strip is not enough (tablet or precipitation tests such as Ictotest or sulfosalicylic acid, historically Clinitest). Confirmation is not “dip it twice and hope the color is prettier.”
Concentration, volume, and named “-urias”
Specific gravity is the density of urine compared with water (water = 1.000 ). It estimates how concentrated the specimen is. Very dilute urine can miss cells and chemicals; very concentrated urine can exaggerate them. Isosthenuric urine near 1.010 is a physiology clue, not a dipstick error by itself.
A refractometer measures refractive index and converts it to SG. Distilled water should read 1.000 before you trust a patient drop. Many clinical refractometers are temperature-compensated; still follow the SOP check. Dipstick SG is a different ionic method and is only an estimate. When the SOP says confirm SG, use the refractometer (or the laboratory’s designated meter), not a second glance at the strip. Radiographic contrast and some dissolved substances can raise refractometer SG more than the ionic pad—another reason the two methods are not interchangeable.
Polyuria is excretion of an abnormally large urine volume (classic adult teaching is more than about 2.5–3 L/day; always interpret with the clinical picture and the timed collection). It is a volume term. Pale color is not automatically polyuria, and a random cup does not measure 24-hour output.
Proteinuria is protein in urine. The strip is most sensitive to albumin . Some clinically important proteins (including certain light chains) may be missed on the pad and need a confirmatory precipitation method if the SOP uses one.
Glycosuria is glucose in urine. The glucose oxidase pad is specific for glucose, not every sugar. A pediatric reducing-substance question is a confirmatory-method question (Section 14.2), not a reason to rename the pad.
Hematuria is blood in urine, classically intact red blood cells . The blood pad detects heme , so free hemoglobin and myoglobin can also turn it positive. The microscope tells you whether intact red cells are present. A positive blood pad with no red cells is not “the strip is broken”; it is a different heme source until proven otherwise.
Pyuria is white blood cells in urine (pus). It suggests inflammation, often infection, but it is not a culture result and not every pyuria is bacterial urinary tract infection.
Ketones are products of fat metabolism (acetoacetate, acetone, β-hydroxybutyrate). The nitroprusside pad mainly detects acetoacetate . Ketonuria appears in fasting, vomiting, uncontrolled diabetes, and some diets. A “negative ketones” strip does not rule out β-hydroxybutyrate-predominant ketoacidosis.
C&S is culture and susceptibility: grow organisms and test antibiotics. A nitrite or leukocyte pad is a screen, not a colony count and not a susceptibility report.
Sediment: what belongs, what does not
Sediment is the concentrated button of formed elements after the specimen is mixed, a measured volume is centrifuged, and the supernatant is decanted. Reading one unspun drop is not a complete microscopic unless the SOP’s automated method replaces centrifugation.
Cells in UA sediment include red blood cells (RBCs), white blood cells (WBCs, usually neutrophils), and epithelial cells (squamous, transitional, renal tubular). Report them as the SOP counts (commonly per high-power field).
Casts are cylindrical molds formed in the distal tubules and collecting ducts, classically on a Tamm-Horsfall (uromodulin) protein matrix. Hyaline casts may appear after exercise or dehydration. Cellular casts (RBC, WBC, renal tubular) point to kidney involvement, not just a dirty cup. Waxy and granular casts suggest more chronic or stasis-related renal disease. Casts are not crystals, not mucus threads, and not clothing fibers.
Crystals are precipitated salts. Which ones you see depends on pH, concentration, and temperature. Acid urine: uric acid, calcium oxalate, amorphous urates. Alkaline urine: triple phosphate (coffin-lid), amorphous phosphates, ammonium biurate. Many crystals are incidental; some (cystine, large numbers of uric acid in the right context, certain drug crystals) matter. Refrigeration creates extra crystals—do not invent a stone disease from a cold cup.
Bacteria may appear as rods or cocci. In an unpreserved delayed specimen they multiply and lie. Seeing bacteria is not a C&S report.
Yeast (often Candida) shows budding and sometimes pseudohyphae. Distinguish yeast from RBCs: RBCs lyse in acetic acid; yeast does not; yeast buds.
Trichomonas is a pear-shaped flagellate parasite. Motility in a fresh wet preparation is the classic clue. It is a pathogen, not a “contaminant darting around.” Delayed urine kills motility and can cause a false-negative microscopic.
Spermatozoa may appear after intercourse or in some male specimens. Report per SOP; they are not infection and not an artifact.
Mucus appears as threads. It is common and usually not pathologic. Do not upgrade mucus to hyaline casts.
A skin contaminant is material that never came from the urinary tract: squamous epithelial cells from skin or vagina, fibers from clothing or diapers, powder, fecal material. Heavy squamous cells mean poor collection, not pyelonephritis.
An artifact is non-anatomic debris: air bubbles, oil droplets, glass, starch, hair, pollen, fibers. Starch can show a Maltese-cross under polarized light and fool someone looking for cholesterol. If it does not match a cell, cast, crystal, or organism, do not name it as one.
- Term Exam-ready meaning Classic trap
- Random Any single void Calling it a culture specimen
- Midstream Skip first and last urine Treating it as cleansing
- Clean-catch Cleanse + sterile cup + midstream Using a nonsterile hat
- Timed (2, 12, 24 h) All urine in a clock window Sending a cupful from the jug
- Macroscopic Physical + chemical Thinking it includes sediment ID
- Microscopic Sediment examination Calling a dipstick “micro”
- Chemical analyses Reagent-strip pads Reporting them as C&S
- Confirmatory tests IFU/SOP follow-up methods Dipping twice
- Specific gravity Concentration vs water Using the strip as a refractometer
- Refractometer Optical SG instrument Skipping the distilled-water check
- Pyuria WBCs in urine Calling it a positive culture
- Hematuria Blood (intact RBCs vs heme) Ignoring hemoglobin/myoglobin
- Glycosuria Glucose in urine Assuming every sugar reacts
- Proteinuria Protein in urine Assuming the pad sees every protein equally
- Polyuria High urine volume Calling pale color “polyuria”
- Ketones Fat-metabolism acids Expecting the pad to see β-hydroxybutyrate well
- C&S Culture and susceptibility Reporting nitrite as C&S
- Sediment Concentrated formed elements Reading unspun urine as a full micro
- Cells RBC, WBC, epithelial Calling all round things RBCs
- Casts Tubular protein molds Confusing with mucus or fibers
- Crystals Precipitated salts Diagnosing stones from every oxalate
- Bacteria Organisms in sediment Equating them with a finished culture
- Yeast Budding fungi Calling them RBCs
- Trichomonas Motile flagellate Reading a delayed cup as negative
- Spermatozoa Sperm in sediment Calling them bacteria or parasites
- Mucus Threads Calling them hyaline casts
- Skin contaminant Extra-urinary debris/cells Calling squamous cells “infection”
- Artifact Non-anatomic junk Reporting bubbles as fat
- In practice
A first-morning clean-catch arrives for “UA with micro and C&S.” Macroscopic: amber and slightly hazy. Chemical analyses: leukocyte esterase positive, nitrite negative, blood small, protein trace. Microscopic: 10–20 WBCs/HPF, few bacteria, many squamous epithelial cells, a hyaline cast, calcium oxalate, and a clothing fiber. You do not report the fiber as a cast, you do not call squamous cells pyelonephritis, you do not convert the dipstick into a culture, and you send the sterile aliquot for C&S as ordered.
Exam traps
Random = midstream = clean-catch.
Casts = crystals = mucus = fibers.
Dipstick nitrite = C&S.
Blood pad = only intact hematuria.
Yeast = RBCs; delayed urine still shows motile trichomonas.
Heavy squamous cells = kidney infection.
Define the word, name what it is not, and keep C&S off the strip.