Study guide
7.3 ASME Section V Articles 1, 6 & 7: General Requirements, PT & MT
API 510 Pressure Vessel Inspector Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Introduction, Scope & Certification Requirements
1.1 Exam Structure, Administration & Study Strategy 1.2 API 510 Code Scope, Exclusions & Jurisdictional Boundaries 1.3 Roles, Responsibilities & Inspector Qualification
2 Chapter 2: Inspection Planning, Data Evaluation & Remaining Life
2.1 Corrosion Rates, Remaining Life & Corrosion Allowance Calculations 2.2 Inspection Intervals, On-Stream Inspection & Interval Deferrals 2.3 Condition Monitoring Locations (CMLs) & Data Analysis
3 Chapter 3: Vessel Evaluation, Corrosion Averaging & Fitness-for-Service
3.1 Corrosion Averaging & Minimum Thickness Evaluation 3.2 Pitting Evaluation & Corroded Area Limits 3.3 Fitness-for-Service (API 579-1) & Risk-Based Inspection (API 580)
4 Chapter 4: ASME Section VIII Div 1 Design & Thickness Calculations
4.1 Internal Pressure Design & Cylindrical Shell Calculations 4.2 Ellipsoidal & Hemispherical Head Calculations 4.3 Spherical Shells, Static Head & Vessel MAWP 4.4 Openings, Nozzle Reinforcement & External Pressure Basics
5 Chapter 5: ASME Section VIII Fabrication, Welds & Joint Efficiency
5.1 Weld Joint Categories (UW-3) & Joint Efficiencies (UW-12) 5.2 Radiographic Examination (UW-11, UW-51, UW-52) 5.3 Post-Weld Heat Treatment (PWHT) & Impact Testing (UCS-56, UCS-66)
6 Chapter 6: Welding Inspection & Metallurgy (API 577 & ASME Sec IX)
6.1 Welding Procedures (WPS/PQR) & Essential Variables 6.2 Welder Performance Qualification (WPQ) & Testing 6.3 Welding Processes, Metallurgy & Weld Discontinuities (API 577)
7 Chapter 7: Nondestructive Examination (ASME Section V)
7.1 Radiographic Examination Techniques & Image Quality Indicators (Article 2) 7.2 Ultrasonic Thickness Measurement (Article 23, SE-797) 7.3 ASME Section V Articles 1, 6 & 7: General Requirements, PT & MT
8 Chapter 8: Damage Mechanisms (API RP 571)
8.1 Atmospheric Corrosion & Corrosion Under Insulation 8.2 HTHA, High-Temperature H2/H2S Corrosion & Sulfidation 8.3 Amine, Caustic & Chloride Stress Corrosion Cracking 8.4 Wet H2S Damage, Brittle Fracture & Erosion-Corrosion 8.5 Boiler-Water, Steam-Condensate & Hydrochloric Acid Corrosion 8.6 Caustic Corrosion & Naphthenic Acid Corrosion
9 Chapter 9: Pressure Vessel Inspection Practices (API RP 572 & API RP 578)
9.1 Internal & External Vessel Inspection Practices (API 572) 9.2 Structural Components, Internal Trays, Linings & Skirts 9.3 Material Verification Programs & Positive Material Identification (API 578)
10 Chapter 10: Pressure-Relieving Devices (API RP 576)
10.1 PRD Types, Construction & Operating Principles 10.2 PRD Causes of Failure, Shop Testing & Overhaul 10.3 PRD Inspection Intervals, Records & Rupture Disks
11 Chapter 11: Repairs, Alterations, Rerating & Pressure Testing (API 510 & PCC-2)
11.1 Repair vs. Alteration Authorization, Execution & Methods 11.2 PCC-2 Core Welded Repairs: Articles 101, 201, 202, 211 & 212 11.3 PCC-2 Special Welding: Articles 209, 210, 215 & 216 11.4 PCC-2 Excavation, Flange, Exchanger & Test Articles 304, 305, 312, 501 & 502 11.5 Vessel Rerating Requirements & Engineering Calculations 11.6 Pressure Testing: Hydrostatic, Pneumatic & NDE in Lieu of Testing
7.3 ASME Section V Articles 1, 6 & 7: General Requirements, PT & MT
Key Takeaways Explain This Topic AI
Article 1 supplies procedure, responsibility, calibration, terminology, and records; the referencing code determines extent and acceptance.
PT finds surface-breaking discontinuities in clean nonporous materials and depends on correct process control.
MT applies to ferromagnetic material; the current BOK limits Article 7 to yoke and prod techniques.
Two approximately perpendicular field directions are needed because detection depends on flaw orientation.
Articles 9 and 10 are not listed in the current effectivity sheet.
Last updated: August 2026
ASME Section V Articles 1, 6, and 7: General Requirements, PT, and MT
For September 2026-May 2027, Section V scope is Articles 1, 2, 6, 7, and Article 23 SE-797. This section covers Article 1, Liquid Penetrant Examination (PT), and yoke/prod Magnetic Particle Examination (MT). Articles 9 and 10 are not listed and are not objectives for this cycle.
1. Article 1 framework
Article 1 supplies the framework every included method uses. Another code, standard, specification, or written requirement invokes Section V. The referencing document determines examination extent and acceptance; Section V supplies procedure, responsibility, calibration, performance, and record rules.
Examination is a method that reveals indications; inspection is the broader verification of compliance.
The owner/user remains responsible even when a subcontractor performs examination.
Delegating work does not delegate owner/user code responsibility.
Calibration and verification must be traceable and follow article/procedure frequency.
Records identify the item and location, procedure, equipment, examiner, results, and disposition.
Article 1 does not make every indication rejectable. The referencing API 510, Section VIII, or repair requirement supplies acceptance.
2. Liquid Penetrant Examination - Article 6
PT detects discontinuities open to a clean surface in nonporous material. It works on carbon steel, stainless steel, nickel alloys, aluminum, and other nonporous materials. It cannot reveal a tight internal flaw that does not reach the surface.
Preclean and dry so oil, scale, paint, or water does not block openings.
Apply visible or fluorescent penetrant for the qualified dwell.
Remove excess with the method matched to its family without flushing flaws.
Dry when required and apply developer.
Allow development, examine under required lighting, interpret, and record.
Post-clean when required.
- PT family Removal Common trap
- Water-washable Controlled water rinse Overwashing shallow flaws
- Post-emulsifiable lipophilic Oil emulsifier then water Excess emulsification
- Solvent-removable Cleaner-moistened cloth Direct solvent spray
- Post-emulsifiable hydrophilic Water remover after pre-rinse Wrong concentration/time
Work outside the standard temperature range requires procedure demonstration at the proposed temperature with the applicable comparator. Extra dwell alone is not qualification. Control contaminants on nickel alloys, stainless steels, and titanium.
3. Magnetic Particle Examination - Article 7
MT detects surface and near-surface discontinuities by magnetizing ferromagnetic material and applying particles. Flux leakage attracts them. Austenitic stainless steel, aluminum, and most nickel-base alloys cannot be assumed suitable.
The BOK limits study to yoke and prod techniques. A yoke establishes a field between poles without passing current through the component. Prods pass current through the work and require control of contacts, spacing, arcing, and heating. Use continuous magnetization: apply particles while the field is active. Verify yoke lifting power at required frequency. Examine in two approximately perpendicular directions because detection is strongest when a flaw is roughly perpendicular to flux.
Surface preparation must allow particle mobility and interpretation. Coating, scale, spatter, or roughness can mask or create indications. Visible particles need adequate white light; fluorescent particles need controlled ambient and qualified UV-A light. Demagnetize when residual magnetism could affect welding, machining, instruments, or service.
4. Selection and records
- Question PT MT
- Material Suitable nonporous material Ferromagnetic only
- Flaw Surface-breaking Surface and shallow near-surface
- Geometry Complex shapes after cleaning Field direction/access matter
- Controls Cleaning, dwell, removal, developer, lighting Technique, direction, particles, field strength
A complete report links indications to component/location and identifies procedure, method/materials, equipment/checks, surface and conditions, examiner, date, results, and disposition. Reexamine repaired areas as required.
Exam traps
Method rules and acceptance criteria are different questions.
PT cannot find a subsurface flaw; MT cannot test nonferromagnetic steel.
One yoke orientation can miss a flaw parallel to the field.
Cleaning is part of examination quality.
5. Indications, evaluation, and procedure qualification
An indication is evidence produced by the examination method; it is not automatically a discontinuity, defect, or rejectable condition. The examiner distinguishes relevant indications from nonrelevant geometry and false indications caused by surface condition or technique, then applies the acceptance criteria supplied by the referencing document. Written procedures identify essential method controls, and required demonstrations show the procedure can produce the intended result. If consumables, temperature, surface condition, field strength, lighting, or another essential control falls outside the qualified range, stop and resolve the deviation rather than rationalizing the result afterward. This chain - qualified procedure, controlled examination, recorded indication, referencing-code evaluation - is the exam-safe workflow.