Study guide
20.2 Timed Code Lookup Drills
Arkansas Journeyman Electrician Exam Study Guide 2026
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Arkansas Exam Overview
1.1 Current Exam Facts 1.2 Arkansas Licensing Pathway & Board Process 1.3 Open-Book Rules & Allowed References 1.4 NEC 2023 Navigation & Lookup Strategy
2 Electrical Theory & Trade Calculations
2.1 Ohm's Law, Power, and Basic Circuits 2.2 Series, Parallel, and Combination Circuits 2.3 Voltage Drop Calculations 2.4 Box Fill Calculations (314.16)
3 Load Calculations (Article 220)
3.1 Standard Dwelling Unit Load Calculations 3.2 Optional Dwelling & Multifamily Demand 3.3 Commercial / Non-Dwelling Demand Factors 3.4 Ampacity Adjustment & Correction (310.15)
4 Grounding Electrode Systems
4.1 Grounding Electrode Types & Installation 4.2 Grounding Electrode Conductor Sizing (250.66) 4.3 Main Bonding Jumper & Service Bonding
5 Equipment Grounding & Bonding
5.1 Equipment Grounding Conductors (250.122) 5.2 Bonding Raceways, Enclosures & Equipment 5.3 Separately Derived Systems Grounding
6 Services & Service Equipment
6.1 Service Entrance Conductors & Clearances 6.2 Service Disconnecting Means 6.3 Service Equipment & Working Space 6.4 Grounding Connections at the Service
7 Feeders & Overcurrent Protection
7.1 Feeder Conductor Sizing 7.2 Overcurrent Device Selection (Art 240) 7.3 Feeder and Branch-Circuit Tap Rules 7.4 Continuous Loads & OCPD Sizing
8 Branch Circuits, GFCI & AFCI
8.1 Branch-Circuit Ratings & Required Circuits 8.2 Dwelling Receptacle Placement & Kitchen/Bath Circuits 8.3 GFCI Protection Requirements 8.4 AFCI Protection Requirements
9 Metal Raceways
9.1 EMT Installation & Supports 9.2 RMC and IMC 9.3 Flexible Metal & Liquidtight Flexible Metal Conduit
10 Nonmetallic Raceways & Enclosures
10.1 PVC and ENT 10.2 Conduit Fill (Chapter 9 Tables) 10.3 Boxes, Conduit Bodies & Fill 10.4 Cabinets, Cutout Boxes & Meter Enclosures
11 Conductor Ampacity & Selection
11.1 Ampacity Table 310.16 Application 11.2 Termination Temperature Limitations 11.3 Conductor Insulation Types & Uses 11.4 Parallel Conductors
12 Cable Assemblies & Terminations
12.1 NM, MC, and AC Cable Assemblies 12.2 Conductor Identification & Color Coding 12.3 Splices, Taps & Terminations
13 Motors (Article 430)
13.1 Motor Nameplate Data & FLC Tables 13.2 Motor Branch-Circuit Conductors 13.3 Motor Overload Protection 13.4 Motor Short-Circuit / Ground-Fault Protection
14 Motor Controls & Transformers
14.1 Motor Disconnects & Controllers 14.2 Motor Control Circuits 14.3 Transformers (Article 450) for Journeymen
15 Utilization & General-Use Equipment
15.1 Luminaires & Lighting (Art 410) 15.2 Receptacles & Switches (Arts 406/404) 15.3 Appliances & Fixed Electric Space-Heating 15.4 Panelboards (Art 408)
16 Special Occupancies
16.1 Hazardous (Classified) Locations Overview 16.2 Health Care, Assembly & Temporary Installations 16.3 Swimming Pools, Spas & Similar Installations
17 Special Equipment Highlights
17.1 Signs & Outline Lighting 17.2 Elevators & Electric Vehicle Power Transfer 17.3 Emergency & Standby Systems Basics
18 Low-Voltage, Alarms & Communications
18.1 Class 1, 2, and 3 Circuits (Art 725) 18.2 Fire Alarm Systems (Art 760) 18.3 Communications Circuits Overview (Art 800+)
19 Electrical Safety
19.1 Working Space & Dedicated Equipment Space (110.26) 19.2 Lockout/Tagout & Safe Work Practices 19.3 Arc-Flash Awareness for the Exam
20 Exam Strategy & Test Day
20.1 Mixed Calculation Lab 20.2 Timed Code Lookup Drills 20.3 Test-Day Checklist, Scoring & Retakes
20.2 Timed Code Lookup Drills
Key Takeaways Explain This Topic AI
Open-book speed on the Arkansas Prov Journeyman form is a navigation skill: classify → tab jump → scope/exceptions → table headers → answer
Budget roughly 3 minutes per item across 60 questions / 180 minutes; abandon lookups that burn ~4 minutes without a controlling section
Drill by Prov outline weight: calcs, services/OCP, raceways, conductors, motors, and grounding get the most tab time
Use Pass A / Pass B / Pass C so heavy calcs do not steal easy lookup points early
Practice with a door-check-ready NEC 2023: permanent tabs, pre-applied highlights/pen underlines only—no margin notes during drills that mimic exam rules
Last updated: August 2026
20.2 Timed Code Lookup Drills
Quick Answer: On Arkansas Journeyman (Prov / Board of Electrical Examiners / ADLL; NEC 2023 ; 60 questions; 3 hours ; 70% ), open book only helps if your fingers find the controlling section in under about a minute. These drills build a fixed lookup workflow, outline-weighted practice sets, and a Pass A/B/C pacing plan matched to CBT ( $80 ) or paper ( $56 ) delivery.
Chapter 1 taught navigation theory. This section is the gym : short, timed reps that transfer to exam day at provexam.com/schedule after your Candidate ID (starts with 200 ) is active.
The five-step lookup (say it aloud in practice)
Classify (≤10 s): service/feeder/branch, grounding, raceway/box, ampacity, motor, utilization, special occupancy, low voltage, or safety?
Tab jump: Go to the permanent tab for that family—do not flip from the cover.
Scope + applicability: Confirm the section applies to the occupancy/equipment in the stem.
Rule → Exceptions → table headers/notes: Exceptions flip answers; footnotes change columns.
Select and leave: If two choices remain, re-check copper/AL, continuous load, or temperature—then move on.
Illegal during drills that mimic Prov: writing in the book, Post-it flags, phone lookups. Legal: scratch paper arithmetic and permanent tabs/highlights prepared beforehand.
Drill set 1 — Sixty-second article finds
Close the book. Start a timer. Open only via tabs. Target: name the article , then land on it in ≤60 seconds .
- Prompt Target family
- Equipment grounding conductor size from breaker rating 250.122
- GEC size from service conductor 250.66
- Dwelling lighting VA/ft² and demand factors 220.41 / Table 220.45
- Box fill volume allowances 314.16
- Conductor ampacity tables / adjustments 310.16 / 310.15
- Motor FLC tables / conductor 125% 430.22 / 430.250
- Branch-circuit GFCI locations (dwellings) 210.8
- Working space about equipment 110.26
- EMT supports Article 358 (with Ch. 3 general rules)
- Continuous load OCPD sizing idea 210.19 / 210.20 / 215.2 family
Score: 8/10 within 60 seconds each is a green light for exam week. Misses become new permanent tabs or brighter highlights—not handwritten margin tips.
Drill set 2 — Exception hunter (90 seconds)
Many JW misses are not “wrong article”—they are missed exceptions . For each prompt, find the base rule and the exception that changes the outcome.
Examples to rotate:
A grounding rule that relaxes size to a single rod electrode (read 250.66 limitations).
A receptacle spacing or GFCI requirement with an exception for a specific location.
A motor protection percentage that changes with motor type or short-circuit device type ( Table 430.52 notes).
A tap rule length/termination condition that makes an otherwise illegal tap legal ( 240.21 ).
Method: finger on the base shall statement, eyes immediately scan for Exception —then decide which choice matches the exception path the stem implies.
Drill set 3 — Table hygiene (2 minutes)
Tables fail candidates who grab the first number they see.
Protocol for every table item:
State the row key (AWG, hp, VA portion, number of CCC, etc.).
State the column conditions (Cu/Al, insulation temp, dwelling vs other).
Read notes above/below the table.
Only then extract the value and apply any required multiplier (80%, 125%, demand factor).
Practice tables: 310.16 , 310.15(C)(1) adjustment, 220.45 , 220.55 , 250.66 , 250.122 , 430.250 , 430.52 , Chapter 9 conduit fill, 314.16(B) .
Drill set 4 — Mixed 15-item sprint (45 minutes)
Build or pull 15 practice items spanning:
- 3 calculation/load
- 3 services/OCP or branch
- 2 raceway/enclosure/fill
- 2 conductors/ampacity
- 2 motors
- 2 grounding/bonding
- 1 utilization or special/low-voltage/safety
Rules:
Pass A (15 min): Answer anything solvable in one tab flip; flag the rest.
Pass B (25 min): Work flags with the five-step lookup.
Pass C (5 min): Recheck only marked items for exception and unit errors.
Goal: finish all 15 with time left. If you routinely run long, your tabs are wrong or you are browsing instead of classifying.
Outline-weighted weekly lookup plan
Match drill minutes to Prov item counts:
- Outline area Items Weekly lookup emphasis
- General Knowledge / Calculations 9 Art. 220 drills + Ohm’s/power sense checks
- Services / feeders / branch / OCP 8 230, 240, 210 lookups
- Raceways and enclosures 8 Ch. 3 methods + Ch. 9 fill + 314
- Conductors 7 310 ampacity/adjustment
- Motors and controls 7 430 tables + control basics
- Grounding and bonding 6 250.66 / 250.122 / bonding
- Utilization 6 Art. 410–440 style finds
- Special occupancies/equipment 4 Ch. 5–6 entry tabs
- Safety 3 110 + jobsite recognition
- Low voltage / comms 2 Ch. 7–8 quick finds
Do not spend equal time on every chapter of the NEC. Spend equal quality time on high-count rows.
Full mock: 60 questions / 180 minutes
Once weekly in the final month:
Use a compliant NEC 2023 (permanent tabs only).
Enforce no marking in the book .
Follow Pass A/B/C.
Log every miss by article , not by “I guessed.”
Next day: only tab/highlight repairs + 10 targeted lookups on miss articles.
Pacing math: 180 ÷ 60 = 3 minutes average. Realistically, bank sub-minute items so multi-table calcs can use 4–5 minutes without sinking the form.
Hard stop rule: If one item hits ~ 4 minutes with no controlling section found, mark it and leave. Three stubborn items can erase your buffer for Article 220 work.
Door-check rehearsal (lookup readiness)
Before any timed mock that claims to simulate Prov:
Confirm no Post-its, handwritten notes, or glued formula sheets.
Confirm tab labels show article numbers .
Confirm highlights/pen underlines were applied before the clock—not during.
A fast book that fails the reference inspection never gets used. Schedule logistics remain Board approval → Candidate ID 200… → provexam.com/schedule → CBT $80 or paper $56. Lookup skill is what converts that seat time into a 70%+ result on the official 60 -question form.