Study guide
20.3 Test-Day Checklist, Scoring & Retakes
Arkansas Journeyman Electrician Exam Study Guide 2026
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Arkansas Exam Overview
1.1 Current Exam Facts 1.2 Arkansas Licensing Pathway & Board Process 1.3 Open-Book Rules & Allowed References 1.4 NEC 2023 Navigation & Lookup Strategy
2 Electrical Theory & Trade Calculations
2.1 Ohm's Law, Power, and Basic Circuits 2.2 Series, Parallel, and Combination Circuits 2.3 Voltage Drop Calculations 2.4 Box Fill Calculations (314.16)
3 Load Calculations (Article 220)
3.1 Standard Dwelling Unit Load Calculations 3.2 Optional Dwelling & Multifamily Demand 3.3 Commercial / Non-Dwelling Demand Factors 3.4 Ampacity Adjustment & Correction (310.15)
4 Grounding Electrode Systems
4.1 Grounding Electrode Types & Installation 4.2 Grounding Electrode Conductor Sizing (250.66) 4.3 Main Bonding Jumper & Service Bonding
5 Equipment Grounding & Bonding
5.1 Equipment Grounding Conductors (250.122) 5.2 Bonding Raceways, Enclosures & Equipment 5.3 Separately Derived Systems Grounding
6 Services & Service Equipment
6.1 Service Entrance Conductors & Clearances 6.2 Service Disconnecting Means 6.3 Service Equipment & Working Space 6.4 Grounding Connections at the Service
7 Feeders & Overcurrent Protection
7.1 Feeder Conductor Sizing 7.2 Overcurrent Device Selection (Art 240) 7.3 Feeder and Branch-Circuit Tap Rules 7.4 Continuous Loads & OCPD Sizing
8 Branch Circuits, GFCI & AFCI
8.1 Branch-Circuit Ratings & Required Circuits 8.2 Dwelling Receptacle Placement & Kitchen/Bath Circuits 8.3 GFCI Protection Requirements 8.4 AFCI Protection Requirements
9 Metal Raceways
9.1 EMT Installation & Supports 9.2 RMC and IMC 9.3 Flexible Metal & Liquidtight Flexible Metal Conduit
10 Nonmetallic Raceways & Enclosures
10.1 PVC and ENT 10.2 Conduit Fill (Chapter 9 Tables) 10.3 Boxes, Conduit Bodies & Fill 10.4 Cabinets, Cutout Boxes & Meter Enclosures
11 Conductor Ampacity & Selection
11.1 Ampacity Table 310.16 Application 11.2 Termination Temperature Limitations 11.3 Conductor Insulation Types & Uses 11.4 Parallel Conductors
12 Cable Assemblies & Terminations
12.1 NM, MC, and AC Cable Assemblies 12.2 Conductor Identification & Color Coding 12.3 Splices, Taps & Terminations
13 Motors (Article 430)
13.1 Motor Nameplate Data & FLC Tables 13.2 Motor Branch-Circuit Conductors 13.3 Motor Overload Protection 13.4 Motor Short-Circuit / Ground-Fault Protection
14 Motor Controls & Transformers
14.1 Motor Disconnects & Controllers 14.2 Motor Control Circuits 14.3 Transformers (Article 450) for Journeymen
15 Utilization & General-Use Equipment
15.1 Luminaires & Lighting (Art 410) 15.2 Receptacles & Switches (Arts 406/404) 15.3 Appliances & Fixed Electric Space-Heating 15.4 Panelboards (Art 408)
16 Special Occupancies
16.1 Hazardous (Classified) Locations Overview 16.2 Health Care, Assembly & Temporary Installations 16.3 Swimming Pools, Spas & Similar Installations
17 Special Equipment Highlights
17.1 Signs & Outline Lighting 17.2 Elevators & Electric Vehicle Power Transfer 17.3 Emergency & Standby Systems Basics
18 Low-Voltage, Alarms & Communications
18.1 Class 1, 2, and 3 Circuits (Art 725) 18.2 Fire Alarm Systems (Art 760) 18.3 Communications Circuits Overview (Art 800+)
19 Electrical Safety
19.1 Working Space & Dedicated Equipment Space (110.26) 19.2 Lockout/Tagout & Safe Work Practices 19.3 Arc-Flash Awareness for the Exam
20 Exam Strategy & Test Day
20.1 Mixed Calculation Lab 20.2 Timed Code Lookup Drills 20.3 Test-Day Checklist, Scoring & Retakes
20.3 Test-Day Checklist, Scoring & Retakes
Key Takeaways Explain This Topic AI
Arkansas Journeyman is Prov-delivered for the Board of Electrical Examiners / ADLL: 60 questions, 3 hours, 70% cut-score, NEC 2023 open book, CBT $80 or paper $56
Schedule only after Board approval at provexam.com/schedule using the full Candidate ID that begins with 200
Bring a door-check-ready NEC 2023 (permanent tabs; pre-applied highlighting/pen underlines only) and required ID; expect no phones, notes, or book marking during the exam
You may retake a failed exam until the end of the eligibility period; after eligibility expires, follow Board retake-form and fee rules
After failing an exam category twice, you may request a review if your score is within 10% of the 70% cut-score; reviews are 1.5 hours under exam-like conditions
Last updated: August 2026
20.3 Test-Day Checklist, Scoring & Retakes
Quick Answer: Sit the Arkansas Journeyman Electrician exam only after the Board of Electrical Examiners (Arkansas Dept. of Labor and Licensing) approves you. Schedule with Prov at provexam.com/schedule using your 10-digit Candidate ID beginning with 200 . Expect 60 multiple-choice questions, 3 hours , 70% cut-score, NEC 2023 open book, and fees of $80 (CBT) or $56 (paper). Retake until eligibility ends; request a review after failing twice if you are within 10% of 70%.
This section is logistics and recovery—not ampacity. Candidates who know Article 250 still fail the day when the book is rejected, the ID is truncated, or retake windows are misunderstood.
Pre-schedule checklist (Board → Prov)
Complete these before you pick a date:
Board approval and registration letter in hand.
Candidate ID recorded carefully: starts with 200 , 10 digits —enter all digits in Prov’s scheduler with your last name.
Confirm you are scheduling the statewide Journeyman form (60Q/3hr), not Residential Journeyman or another class.
Decide CBT ($80) vs paper/pencil ($56) and pay through Prov’s process.
Read the live ARDOL-Electrical Candidate Information Bulletin for center rules, ID requirements, and reference rules the week you schedule.
Official bulletin PDF (verify current link): ARDOL-Electrical 2023.11.10 . Board hub: labor.arkansas.gov electrical licensing .
Eligibility timing (per Prov CIB themes): after approval you contact Prov within the stated window (bulletin discusses contacting Prov within about six months of approval) and you may continue retesting until the end of the 1-year eligibility period described in the Retesting Policy. Always confirm the live bulletin dates—do not rely on memory of an older PDF.
Night-before pack list
- Item Notes
- Government photo ID Name must match scheduling identity
- Candidate ID / confirmation Know the 200… number; bring confirmation printout if Prov provides one
NEC 2023 codebook Permanent tabs; highlighting/pen underlines only; no handwritten notes, Post-its, glued sheets
Directions / arrival plan Aim early for parking + reference inspection
Soft supplies Whatever Prov allows for scratch work at that center—confirm CIB; never plan to write in the book
What to leave out Phones, smart watches, notes, unauthorized indexes, study guides
Do a mock door check at home: flip every page for illegal notes or moveable tabs. If Prov’s administrator rejects the book, you sit without your open-book advantage—or you may not sit as planned.
Arrival and room rules (practical)
Arrive early enough for check-in and reference inspection before the timed clock.
Expect a controlled room: no talking, no electronic devices, no visitors, no cheating, no marking in books during the exam.
Violations can mean dismissal, frozen results, forfeited fees, and a report to the Board.
Open book means open authorized codebook —not open phone or open friend.
In-seat strategy (day-of execution)
Confirm the clock: 180 minutes for 60 items.
Pass A: Answer known and one-tab items; flag multi-table calcs.
Pass B: Work flags with classify → tab → exceptions → tables.
Pass C: Recheck marked items for demand-factor skips, Cu/Al mistakes, and GEC vs EGC table mix-ups.
Hard stop: ~4 minutes stuck → mark and move.
Target for a pass: at least 70% correct ≈ 42/60 . Do not chase perfection on one motor stem while leaving five easy lookups unanswered.
Scoring and who contacts you
Computer-based exams are typically scored immediately in Prov’s system after you finish.
Because the exam is a licensure requirement, candidates consent to Prov sharing results with the Arkansas Department of Labor — Electrical Examining Board .
Plan on Board follow-up for score communication and next licensing steps even when CBT shows an on-screen result.
A passing score is necessary but not always the final administrative step for the license card—follow Board issuance instructions after you pass.
Retesting policy (eligibility window)
Per Prov’s ARDOL Electrical bulletin:
You may retake a failed examination as often as necessary until the end of the 1-year eligibility period .
Once eligibility expires, you must submit to the Board a retake form along with an additional examination fee (see Board site for the current form and amounts).
Candidates cannot retake an exam they have already passed unless the Board requires it.
Practical implication: do not burn the eligibility year waiting to “feel ready” without scheduled attempts. Use free timed practice, then sit while eligibility is live. Each attempt still incurs Prov’s exam fee structure (CBT $80 / paper $56 on the published form—confirm at scheduling).
Reviews after repeated fails
Prov’s review rules for this program:
You may request a review after failing an exam category two (2) times .
To be eligible, you must score within 10% of the required 70% passing score (roughly mid-60s and up—confirm the exact eligibility language in the live CIB).
The review lasts 1.5 hours .
During the review you receive a printout of missed questions and the answers you chose .
The review runs under exam-like conditions (controlled environment—not a tutoring session with your phone).
Use a review as a diagnostic: map misses to articles (220, 250, 310, 430, 314, etc.), then repair tabs and drill those families before the next paid attempt.
After you pass — Board side of the house
Watch for Board score/license instructions.
Complete any remaining issuance steps or fees the Board lists.
Calendar renewals and CEU rules from the Board—not from Prov’s testing bulletin.
Keep working under the correct license class (Journeyman limits vs Master contracting rules).
Prov’s job ends at delivery and scoring of the exam form. Career legality stays with the Board of Electrical Examiners / ADLL .
Same-day failure recovery plan
If you miss 70%:
Write down outline areas that felt weak while memory is fresh (no codebook notes needed—use your own paper at home).
Check eligibility end date immediately.
Schedule the next attempt inside the window rather than drifting months.
If you have now failed twice and are within 10% of 70%, decide whether a 1.5-hour review is worth the fee/time before retesting.
Rebuild from miss articles: mixed calc lab (§20.1) + timed lookups (§20.2) for one to two focused weeks.
Final one-page day-of card (memorize, don’t glue into the book)
Board approved? Candidate ID 200________ ?
Scheduled at provexam.com/schedule ? Fee $80 CBT or $56 paper?
NEC 2023 door-check ready?
60 Q / 3 hr / 70% / Pass A-B-C / 4-minute abandon rule?
Retakes until eligibility ends; review after 2 fails if within 10% of 70%?
If you can answer yes to those lines, your remaining job is execution—not logistics scavenger hunts in the parking lot.