Study guide
9.2 Tank Mix Compatibility & Mixing Order
Arkansas Pesticide Applicator Certification Exam Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Arkansas Pesticide Laws, Regulations & Licensing Framework
1.1 Arkansas Statutory & Regulatory Framework 1.2 Arkansas Applicator Classifications & Licensing 1.3 Arkansas Pesticide Classification System (Classes A-J) & Dicamba Rules 1.4 FIFRA & Federal Regulatory Framework 1.5 Product Registration, RUP Dealers & Special Permits 1.6 Arkansas Herbicide Application Equipment Set-Up Rules
2 Chapter 2: Pesticide Safety, Human Toxicology & Emergency Response
2.1 Principles of Toxicology & Exposure Routes 2.2 Personal Protective Equipment (PPE) & Respiratory Protection 2.3 First Aid Protocols & Poisoning Emergency Response 2.4 Pesticide Storage, Secure Transport & Spill Management 2.5 Heat Stress, PPE Load & Work-Rest Management 2.6 Container Rinsing, Rinsate & Excess Pesticide Disposal 2.7 Cholinesterase Monitoring & Medical Supervision
3 Chapter 3: Worker Protection Standard (WPS) & Agricultural Safety
3.1 Worker Protection Standard (WPS) Core Requirements 3.2 Restricted-Entry Intervals (REI) & Decontamination Protocols 3.3 WPS Training, Information Display & Employer Records
4 Chapter 4: Pesticide Labeling, Hazard Communication & Compliance
4.1 Anatomy of a Pesticide Label & Legal Force 4.2 Signal Words, Toxicity Categories & Hazard Statements 4.3 Directions for Use & Mandatory vs. Advisory Statements 4.4 Reading a Label Under Pressure: Rates, PHI, Rotations & Supplemental Labelling
5 Chapter 5: Environmental Stewardship & Aquatic Ecosystem Protection
5.1 Spray Drift Physics & Mitigation 5.2 Protecting Groundwater, Surface Water & Arkansas Aquifers 5.3 Endangered Species & Pollinator Protection 5.4 Arkansas Agro-Ecosystems & Rice Paddy Protection 5.5 Pesticide Fate in Soil and Water: Solubility, Adsorption, Persistence & Volatility 5.6 Pre-Application Site Assessment & Sensitive Area Management
6 Chapter 6: Formulations, Application Equipment & Sprayer Calibration
6.1 Pesticide Formulations & Adjuvant Chemistry 6.2 Application Equipment Operation & Nozzle Engineering 6.3 Sprayer Calibration Formulas & Calculations 6.4 Tank Mixing, Loading Math & Active Ingredient Rates 6.5 Pesticide Math Foundations: Units, Areas, Percentages & Dilutions 6.6 Calibrating Granular, Band & Spot Applications 6.7 Sprayer Maintenance, Tank Cleanout & Storage
7 Chapter 7: Integrated Pest Management (IPM) & Resistance Management
7.1 Fundamentals of Integrated Pest Management 7.2 Economic Thresholds & Pest Population Dynamics 7.3 Pesticide Resistance Management & Mode of Action 7.4 Pest Recognition & the Major Pest Groups 7.5 The Six Pest Control Methods 7.6 Pesticide Types, Selectivity & How Products Move in the Target 7.7 Diagnosing Herbicide Injury & Off-Target Damage
8 Chapter 8: Commercial Applicator Operations, Recordkeeping & Field Protocols
8.1 Commercial Firm Operations & Supervision 8.2 Recordkeeping, School Applications & Incident Reporting 8.3 Supervising Noncertified Applicators Under 40 CFR Part 171 8.4 Professionalism, Chemical Security & Product Stewardship
9 Chapter 9: Application Methods, Tank Mixing & Specialized Applications
9.1 Choosing an Application Method 9.2 Tank Mix Compatibility & Mixing Order 9.3 Chemigation & Backflow Prevention 9.4 Fumigation Fundamentals & Soil Fumigant Requirements
9.2 Tank Mix Compatibility & Mixing Order
Key Takeaways Explain This Topic AI
Always run a jar test before mixing unfamiliar products: combine them in a clear jar at the same proportions as the field mix, agitate, and watch for separation, gels, flakes, precipitate, oiling out or heating.
Mixing order matters because it controls dispersion: a common workable sequence is water, compatibility agent, dry flowables and water-dispersible granules, wettable powders, then flowables and suspensions, then water-soluble products, then emulsifiable concentrates, then surfactants and oils, adding each with agitation running.
Water quality drives failures independently of product compatibility - hard-water cations tie up glyphosate and some other weak-acid herbicides, and alkaline water hydrolyzes several organophosphates in the tank.
Antagonism means the mixture performs worse than the components alone - the classic case is a broadleaf herbicide reducing the grass activity of an ACCase inhibitor - while a physically stable mix can still be agronomically wrong.
The label controls: a prohibited tank mix is a violation, and in Arkansas glyphosate may not be tank mixed with in-crop dicamba during the April 16 through June 30 window.
Last updated: September 2026
9.2 Tank Mix Compatibility & Mixing Order
Core Concept: A tank mix can fail three different ways, and they need different fixes. Physical incompatibility produces a mess in the tank - gels, curds, separation, plugged screens. Chemical degradation destroys the active ingredient in the tank without any visible sign. Biological antagonism leaves a perfect-looking tank that simply does not control the pest. A jar test catches the first. Water testing catches the second. Reading the label and knowing the chemistry catches the third.
The Jar Test
Run it any time you are mixing products you have not combined before, or when you change water sources.
Use a clear quart jar with a lid.
Add water in the same proportion the field mix will use - if the field rate is 15 gallons per acre with 1 quart of product per acre, scale accordingly.
Add the products in the intended mixing order , shaking after each addition.
Include the adjuvants you intend to use, at the same proportions.
Let the jar stand 15 to 30 minutes .
Inspect.
- What you see Meaning
- Uniform suspension or emulsion Physically compatible; proceed
- Separation into layers that re-mix on shaking Marginal - may be usable with continuous agitation
- Gel, curd, flakes, sludge or precipitate Incompatible. Do not mix - this will plug screens and nozzles
- Oiling out - free oil on the surface that will not re-disperse Incompatible
- Heat or gas generation Stop. A chemical reaction is occurring
A compatibility agent may resolve a marginal physical incompatibility. It does not fix chemical degradation or antagonism.
Mixing Order
Mixing order exists so each formulation gets a chance to disperse in water before the next one competes for it. A widely used sequence, with agitation running throughout : 1. Fill tank half to two-thirds with clean water; start agitation
- 2. Compatibility agent, if used
- 3. Water-dispersible granules (WDG) / dry flowables (DF)
- 4. Wettable powders (WP)
- 5. Water-soluble bags (WSP) - add whole, allow to dissolve fully
- 6. Flowables and suspension concentrates (F, SC)
- 7. Water-soluble concentrates / solutions (SL)
- 8. Emulsifiable concentrates (EC)
- 9. Surfactants, crop oils and drift retardants
- 10. Top off with the remaining water; keep agitating until sprayed out
Two mnemonics are common - " WAMLEGS " and " dry before liquid, and oils last " - but the label always outranks a mnemonic. If a product label specifies its own order, follow it.
Practical rules that go with the sequence:
Never add a dry formulation to a nearly empty tank. It will cake on the bottom.
Pre-slurry wettable powders in a bucket where the label directs it.
Add water-soluble packets whole - never cut them open.
Keep agitation running from the first addition until the tank is empty; a mix that separated overnight cannot be salvaged by agitating in the morning.
Do not let a mixed tank stand. Many mixes are stable for hours, not days.
Water Quality: The Invisible Failure
Physical compatibility can be perfect while the mix is chemically dying.
Water problem Effect Fix
Hardness - calcium, magnesium, iron, sodium cations Bind weak-acid herbicides such as glyphosate and some others, forming poorly absorbed salts. Efficacy drops with no visible change Ammonium sulfate where the label permits, added before the herbicide
High pH (alkaline) Alkaline hydrolysis degrades many organophosphate and carbamate insecticides and some fungicides, sometimes within hours in the tank Buffering agent to lower pH where the label permits; mix and spray promptly
Low pH (acidic) Degrades a smaller set of products; can also affect adjuvant performance Buffer as the label directs
Suspended sediment and organic matter Adsorbs active ingredient, particularly cationic herbicides such as paraquat and diquat; plugs screens Use clean water; filter
Very cold water Slows dissolution of dry formulations, causing lumps Allow more agitation time
Test your water. A single water analysis for pH and hardness costs almost nothing and explains a great many "the product did not work" complaints.
Antagonism Versus Synergism
Antagonism : the mixture performs worse than the components would alone. The best-known agronomic example is a broadleaf herbicide reducing the grass activity of an ACCase inhibitor applied in the same tank - the tank is perfectly stable and the grass control is poor. Sequential application, or a label-specified adjuvant and rate adjustment, is the fix.
Synergism : the mixture performs better than the sum of the components. Useful when it is intended and label-supported, and a resistance-management asset when it comes from combining effective modes of action.
Additive : performance equals the sum of the parts, which is the usual and expected result.
A tank mix that is physically fine and chemically stable can still be the wrong decision agronomically. Check the label's tank mix section, and where a label directs a sequential rather than a tank-mix application, follow it.
When the Label or the State Says No
A prohibited tank mix is a violation. If the label says "do not tank mix with X," mixing with X is a use inconsistent with the labelling under FIFRA, regardless of whether the jar test looks fine.
Arkansas Class H : from April 16 through June 30 , in-crop agricultural dicamba applications are prohibited from using tank mixes of glyphosate-containing products with in-crop dicamba products . This is a state rule sitting on top of whatever the federal label allows.
Arkansas Enlist exemption : tank mixes are not permitted unless research data from a source acceptable to the Board shows the mix does not increase driftable fines below 200 microns by more than 10 percent over the product alone, and in no case may more than 10 percent of the total mix's droplets be smaller than 200 microns .
FIFRA Section 2(ee) permits mixing a pesticide with a fertilizer when the mixture is not prohibited by the labelling - which is a permission, not a licence to ignore a prohibition.
Warning
Exam Trap: A Clean Jar Test Does Not Make a Mix Legal The most common wrong answer on this topic is that a successful jar test authorizes the mix. A jar test evaluates physical compatibility only. It cannot detect alkaline hydrolysis, it cannot detect antagonism, and it has no bearing whatsoever on a label prohibition or on the Arkansas glyphosate-plus-dicamba ban.