1 Introduction & the SPI Exam
What the SPI Is & Why Physics Matters The V24.1 Content Outline & How to Study It Math, Units & Decibels You Must Know
2 Properties of Ultrasound Waves
Sound as a Mechanical Longitudinal Wave Period, Frequency & Wavelength Propagation Speed & the Wavelength Equation Amplitude, Power & Intensity
3 Pulsed Ultrasound
Continuous vs Pulsed Wave; PRF & PRP Pulse Duration, Spatial Pulse Length & Duty Factor Bandwidth, Q-Factor & Damping
4 Interaction of Sound with Tissue
Attenuation: Absorption, Reflection & Scattering The Attenuation Coefficient & Half-Value Layer Acoustic Impedance & Reflection Refraction, Snell's Law & the Range Equation
5 Transducers & Sound Beams
Construction & the Piezoelectric Effect The Sound Beam: Near/Far Field & Focusing Array Transducers Transducer Selection, Frequency Trade-offs & Nonimaging Probes
6 Resolution
Axial Resolution Lateral & Elevational Resolution Temporal Resolution & Frame Rate
7 Pulse-Echo Instrumentation & the Imaging Chain
Beam Former, Pulser & Output Power The Receiver: Amplification & Time-Gain Compensation Dynamic Range & Compression Signal Processing: Demodulation, Rejection & Pre/Post-Processing Scan Converter, Display & Image Storage
8 Display Modes & Image-Optimization Features
A-Mode, B-Mode & M-Mode Harmonic Imaging Spatial & Frequency Compounding, Panoramic Imaging 3D/4D Imaging & Contrast Agents
9 Doppler Principles & Instrumentation
The Doppler Effect, Shift & Equation The Doppler Angle & Cosine Continuous-Wave Doppler Pulsed-Wave Doppler, Sample Volume & Nyquist Limit Aliasing & How to Eliminate It Spectral Doppler Analysis & Waveforms Color & Power Doppler Hemodynamics & Doppler Measurements
10 Artifacts
Propagation Artifacts Attenuation & Beam-Width Artifacts Doppler & Color Artifacts
11 Bioeffects, Safety & Quality Assurance
Bioeffects Mechanisms: Thermal & Cavitation Thermal & Mechanical Index & ALARA Quality Assurance & Tissue-Mimicking Phantoms Statistical Parameters: Sensitivity, Specificity & Predictive Value Patient Care, Ergonomics, Infection Control & Workflow
Array Transducers
Key Takeaways Explain This Topic AI
Linear and curved (curvilinear) arrays both fire a shifting sub-aperture of adjacent elements sequentially, producing rectangular and trapezoidal images respectively.
Phased arrays fire the entire small-footprint aperture on every pulse, using per-element time delays to electronically steer and focus a sector image, ideal for the narrow cardiac acoustic window.
Annular arrays use concentric ring elements that must be steered mechanically, because the rings have no left-right separation to create the delay pattern electronic steering requires.
Annular arrays gain excellent, symmetric focusing in both the lateral and elevational planes simultaneously as a trade-off for requiring mechanical steering.
2D matrix arrays arrange elements in rows and columns, enabling electronic steering and focusing in two perpendicular planes for real-time 3D/4D volume imaging.
Last updated: July 2026
- Array Transducers
- From One Element to Many: Why Arrays Exist
A transducer built from a single large piezoelectric disc can only produce one fixed beam shape, focus, and steering angle — useful for simple nonimaging Doppler, but too limited for real-time imaging. Modern imaging probes instead use an array : dozens to well over a thousand small elements, each wired separately and fired in a controlled electronic pattern. Arrays are what make electronic beam steering, multi-zone focusing, and real-time image formation possible.
Linear (Sequential) Array
A linear array , also called a sequential array, arranges its elements in a single straight row behind a flat, rectangular footprint. To form one scan line, a small group of adjacent elements — a sub-aperture — fires together; the active sub-aperture then shifts down the row, element by element, firing again to form the next parallel scan line, and so on across the full face. The result is a rectangular image made of parallel scan lines, matched to a rectangular footprint. Linear arrays are the workhorse for superficial, high-resolution imaging — vascular, thyroid, testicular, musculoskeletal, and breast — where high frequency and a wide near-field field of view at the skin surface both matter.
Curved (Curvilinear) Array
A curved array uses the identical sequential firing and shifting sub-aperture principle as a linear array, but its row of elements sits along a convex curved face rather than a flat one. Because the individual scan lines fan outward from a curved surface, the resulting image is trapezoidal , widening with depth — giving a much larger field of view at depth than a linear array's footprint size would otherwise allow. Curved arrays are the standard choice for abdominal and obstetric imaging, where deeper structures need to be visualized across a wide field.
Phased Array
A phased array takes a very different approach: rather than shifting a small sub-aperture across the row, every element in the typically small array fires on every single pulse. Each element's excitation is triggered with an individually calculated, minutely different time delay , so that the wavefronts launched from every element interfere constructively along a chosen direction — electronically steering the beam to a selected angle while simultaneously focusing it, with no physical movement of any part. Sweeping that steering angle rapidly across a range of angles builds a sector-shaped image from a small, compact footprint. This small footprint is exactly why phased arrays are the standard for cardiac imaging, where the beam must pass through the narrow intercostal acoustic window between ribs.
Annular Array
An annular array arranges its piezoelectric material into concentric rings, resembling a target, rather than side-by-side elements in a row. Because the rings are radially symmetric — there is no left element and right element to create the asymmetric delay pattern electronic steering requires — an annular array cannot be steered electronically and must instead be swept mechanically . The trade-off is a real gain in focusing quality: because concentric-ring delays apply symmetrically in every radial direction at once, annular arrays achieve excellent focusing in both the lateral and elevational planes simultaneously , unlike a standard one-dimensional array (linear, curved, or phased), which focuses electronically only in the lateral plane and relies on a fixed lens elevationally.
2D Matrix Array
A 2D matrix array extends the array concept into two dimensions: elements are arranged in rows and columns across a flat or slightly curved face, rather than a single row. This grid allows electronic steering and multi-zone focusing in two perpendicular planes at once (azimuth and elevation), which is what makes true real-time 3D/4D volume acquisition possible without mechanical motion. Because a full matrix can contain many thousands of elements, far more than practical cabling could connect independently, matrix probes rely heavily on sub-aperture grouping : elements are organized into patches sharing a reduced number of physical channels, keeping connector count manageable while approximating full two-dimensional electronic control.
Summary Table
- Array type Element layout Steering/focusing method Footprint Image shape Typical use
- Linear (sequential) Single row Shifting sub-aperture Flat, rectangular Rectangular Vascular, small parts, MSK
- Curved (curvilinear) Single row, convex Shifting sub-aperture Curved Trapezoidal Abdominal, obstetric
Phased Small, single row Electronic time-delay steering; full aperture fires Small, compact Sector Cardiac (intercostal window)
Annular Concentric rings Mechanical steering; symmetric electronic focusing Round Sector (mechanically swept) Applications needing symmetric focus
2D matrix Rows and columns Electronic steering/focusing in two planes Matrix/flat Volume (pyramidal) Real-time 3D/4D
Every array design trades footprint size, steering method, and focusing symmetry against one another; the right array matches its acoustic window and beam-shaping method to the anatomy being imaged.
Linear and curved arrays both fire a shifting sub-aperture sequentially; curved arrays trade footprint size for a wider trapezoidal field of view at depth
Phased arrays fire their entire small aperture on every pulse, using per-element time delays to electronically steer and focus a sector image, ideal for the narrow cardiac acoustic window
Annular arrays use concentric rings that must be steered mechanically, since ring symmetry provides no left-right path for electronic steering, in exchange for symmetric lateral-and-elevational focusing
2D matrix arrays use rows and columns of elements, enabling electronic steering/focusing in two planes for real-time 3D/4D imaging, with sub-aperture grouping to manage channel count
A transducer's footprint and array type are matched to the required field of view and available acoustic window for each clinical application