Study guide
9.4 Wood Systems: Light-Frame, Heavy Timber & Mass Timber (CLT)
ARE 5.0 Project Planning & Design PPD
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview & Schematic Design Process
1.1 ARE 5.0 PPD Format, Scoring & Case Study Navigation 1.2 The Schematic Design Phase & Multi-Discipline Workflow 1.3 Regulatory Framework: Navigating Codes, Standards & Jurisdictions
2 Chapter 2: Site Analysis, Topography & Soil Conditions
2.1 Site Topography, Grading, Slopes & Cut/Fill Calculations 2.2 Geotechnical Reports, Soil Classification & Foundation Selection 2.3 Site Hydrology, Drainage & Stormwater Management Neighborhood Context, Historic Settings & Site Integration
3 Chapter 3: Climate, Microclimate & Solar Design
3.1 Solar Geometry, Sun Angles & Sun Path Diagrams 3.2 Microclimate Analysis, Prevailing Winds & Passive Ventilation 3.3 Passive Solar Heating & Thermal Mass Strategies
4 Chapter 4: Sustainable Principles & Energy Standards
4.1 Daylighting Metrics: Spatial Daylight Autonomy (sDA) & Annual Sun Exposure (ASE) 4.2 Building Energy Standards: ASHRAE 90.1, IECC & Energy Use Intensity (EUI) 4.3 High-Performance Frameworks: LEED v4.1, Net Zero & Embodied Carbon
5 Chapter 5: Zoning Regulations & Land Use Controls
5.1 Zoning Envelopes: Setbacks, Floor Area Ratio (FAR) & Lot Coverage 5.2 Parking Requirements, Access & Site Circulation Planning 5.3 Environmental Regulations: Wetlands, Flood Zones & Brownfields
6 Chapter 6: Building Code Fundamentals: Occupancy & Construction Types
6.1 IBC Occupancy Classifications & Group Characteristics 6.2 Mixed Occupancy Strategies: Nonseparated, Separated & Accessory 6.3 IBC Construction Types I Through V & Fire-Resistance Ratings 6.4 Allowable Building Height & Area Calculations (IBC Tables 504 & 506)
7 Chapter 7: Means of Egress & Fire Protection
7.1 Occupant Load Determination & Egress Sizing (IBC Chapter 10) 7.2 Egress Components: Common Path, Travel Distance & Exit Separation 7.3 Passive Fire Protection: Fire Walls, Barriers & Smoke Partitions 7.4 Active Fire Suppression: Sprinklers, Standpipes & Fire Alarms
8 Chapter 8: Accessibility & Universal Design
8.1 Accessible Routes, Curb Ramps & Parking Layouts (ADA / ICC A117.1) 8.2 Interior Accessibility: Doors, Maneuvering Clearances & Corridors 8.3 Accessible Plumbing Facilities: Restrooms, Grab Bars & Fixture Layouts
9 Chapter 9: Structural Systems: Wood, Steel, Concrete & Masonry
9.1 Structural Selection & Spanning Rules of Thumb 9.2 Steel Framing Systems: Beams, Girders & Open-Web Joists 9.3 Concrete Framing Systems: One-Way, Two-Way & Post-Tensioned Slabs 9.4 Wood Systems: Light-Frame, Heavy Timber & Mass Timber (CLT)
10 Chapter 10: Lateral Force Resisting Systems & Foundations
10.1 Lateral Load Paths: Wind vs. Seismic Forces 10.2 Shear Walls, Braced Frames & Moment Frames 10.3 Shallow vs. Deep Foundation Systems: Footings, Mats, Piles & Caissons
11 Chapter 11: Building Envelope: Physics, Assemblies & Moisture Control
11.1 Envelope Thermal Performance: U-Values, R-Values & Thermal Bridging 11.2 Moisture Management: Vapor Retarders, Air Barriers & Water Resistive Barriers 11.3 High-Performance Wall & Roof Assemblies: Rainscreens & Inverted Roofs 11.4 Fenestration & Glazing: U-Factor, SHGC, Condensation Resistance & VT Interior Materials, Durability & Program Performance
12 Chapter 12: Mechanical & HVAC Systems
12.1 HVAC System Types: All-Air, Air-Water, All-Water & VRF Systems 12.2 Central Plant Equipment: Chillers, Boilers, Cooling Towers & Geothermal 12.3 Ductwork Distribution, Air Handling & Plenum Space Requirements 12.4 Indoor Air Quality, Ventilation Rates & ASHRAE 62.1 Baselines
13 Chapter 13: Plumbing, Electrical & Life Safety Systems
13.1 Domestic Water Supply & Pressure Boosting Systems 13.2 Sanitary Drainage, Venting & Fixture Count Calculations 13.3 Electrical Service, Transformers, Switchgear & Backup Generators 13.4 Lighting Design, Controls & Lighting Power Density (LPD) Limits
14 Chapter 14: Specialized Building Systems & Vertical Circulation
14.1 Architectural Acoustics: STC, NRC, RT60 & Noise Criteria (NC) 14.2 Elevator Systems: Traction vs. Hydraulic, Core Layout & Sizing 14.3 Building Telecommunications, Security & Building Automation Systems (BAS)
15 Chapter 15: Systems Integration & Coordination
15.1 Floor-to-Floor Height & Plenum Coordination (Structure + MEP + Architecture) 15.2 Structural Grid Planning & Spatial Adjacencies 15.3 Building Massing, Orientation & Envelope Integration 15.4 Case Study Strategy: Synthesizing Drawings, Code Sheets & Schedules
16 Chapter 16: Project Costs, Budgeting & Life-Cycle Analysis
16.1 Schematic Estimating Techniques: Area, Volume & Parametric Costs 16.2 Project Budgets: Contingencies, Overhead, Profit & Escalation 16.3 Life-Cycle Cost Analysis (LCCA) & Value Engineering
9.4 Wood Systems: Light-Frame, Heavy Timber & Mass Timber (CLT)
Key Takeaways Explain This Topic AI
Wood is moisture-sensitive; engineered products reduce variability but do not eliminate dimensional movement.
Fireblocking and draftstopping address different concealed-space paths and have specific code locations and exceptions.
Mass-timber fire design uses a reduced effective section and protected connections, not an unchanged-strength core.
For qualifying Group B conditions, IV-C permits nine stories; always check occupancy, sprinklers and detailed protection.
Last updated: October 2026
9.4 Wood Systems: Light-Frame, Heavy Timber & Mass Timber (CLT)
Wood is humanity's oldest renewable structural material and remains the dominant framing method for residential and light commercial construction across North America. In recent years, advances in timber engineering have transformed wood from a material limited to low-rise light-frame buildings into Mass Timber —a high-performance structural medium capable of framing high-rise commercial flagships and multi-story institutional complexes under modern building codes.
On the ARE 5.0 PPD exam, candidates must master wood natural anisotropic material behavior, differentiate platform from balloon framing, enforce IBC fire blocking and draft stopping mandates, calculate Heavy Timber fire charring rates, and evaluate Mass Timber classifications (CLT, Glulam, DLT, NLT) under the 2021 International Building Code.
Wood Orthotropy & Moisture Physics
Unlike structural steel, which is isotropic (behaving identically in all directions), wood is an anisotropic and orthotropic cellular material. Its structural properties, fiber stiffness, and dimensional stability differ across three mutually perpendicular geometric axes:
Longitudinal Axis (Parallel to Grain): Aligned with the vertical tree trunk. Wood possesses exceptional tensile and compressive strength parallel to the grain.
Radial Axis (Perpendicular to Growth Rings): Radiating outward from the central pith toward the bark.
Tangential Axis (Perpendicular to Grain, Tangent to Growth Rings): Tangent to the annual growth rings.
Under transverse loading, wood is extremely weak in tension perpendicular to grain . Connections that introduce cross-grain tension (such as hanging heavy mechanical loads from the bottom of wood beams without top-flange straps) frequently cause catastrophic splitting along the wood grain.
Moisture Content & Differential Shrinkage
Wood is hygroscopic, absorbing and desorbing moisture to reach equilibrium with surrounding relative humidity:
Fiber Saturation Point (FSP) : Occurs when all cell cavities are empty of free water but cell walls remain saturated with bound water (typically 28% to 30% moisture content ).
Dimensional Movement Below FSP : As wood dries below FSP, water leaves cell walls, causing physical shrinkage. Wood dimensional movement varies dramatically by axis:
Tangential Shrinkage : Greatest movement, typically 6% to 10% from green to oven-dry.
Radial Shrinkage : Moderate movement, roughly half of tangential shrinkage ( 3% to 5% ).
Longitudinal Shrinkage : Negligible movement along the grain length, typically 0.1% to 0.2% .
Architectural Detailing Implication : In multi-story wood platform framing, cumulative shrinkage across horizontal wood elements (sole plates, rim joists, floor joists, top plates) can cause vertical building settlements of 1 / 2 to 3 / 4 inch 1/2\text{ to }3/4\text{ inch} 1/2 to 3/4 inch per floor . Unless detailed with telescoping expansion joints, this movement shears rigid plumbing risers, cracks exterior masonry veneer ties, and buckles exterior cladding.
Light-Frame Wood Construction
Light-frame wood construction utilizes nominal dimension lumber ( 2 × 4 , 2 × 6 , 2 × 8 , 2 × 10 , 2 × 12 2\times4, 2\times6, 2\times8, 2\times10, 2\times12 2 × 4 , 2 × 6 , 2 × 8 , 2 × 10 , 2 × 12 ) or engineered wood joists spaced at 16 or 24 inches 16\text{ or }24\text{ inches} 16 or 24 inches on center , covered with structural plywood or oriented strand board (OSB) sheathing panels ( 4 ft × 8 ft 4\text{ ft} \times 8\text{ ft} 4 ft × 8 ft ) to form structural diaphragms and shear walls.
Platform Framing vs. Balloon Framing
Balloon Framing (Historical) : Wall studs run continuously from the foundation sill plate through two full stories to the roof rafters. Floor joists are notched or hung from an intermediate ribbon board let into the continuous studs. Balloon framing has been universally abandoned in modern construction because tall open stud bays act as continuous chimneys (flues) during a fire, spreading flames rapidly from basement to attic, and long straight solid lumber is difficult to source.
Platform Framing (Modern Universal Standard) : Each story is constructed as a separate structural platform. Subfloor sheathing is laid over floor joists, and wall framing studs (one story in height) are erected directly on top of the subfloor deck. Platform framing naturally provides fire stopping at each floor line, simplifies wall prefabrication on the deck, and uses shorter, economical lumber lengths.
Engineered Wood Products (EWP)
Wood I-Joists : Composed of top and bottom solid sawn lumber or laminated veneer lumber (LVL) flanges grooved to receive a structural OSB or plywood web. Reduces variability in warping, crown and shrinkage compared with typical sawn members, while remaining moisture-sensitive; spans up to 26 ft 26\text{ ft} 26 ft with depths of 9.5 to 16 inches 9.5\text{ to }16\text{ inches} 9.5 to 16 inches ( L / 18 L/18 L /18 ). Holes can be cut in webs per manufacturer knockout guidelines, but flanges must never be notched, cut, or drilled .
Laminated Veneer Lumber (LVL) : Manufactured by bonding thin wood veneers ( 1 / 10 ′ ′ to 1 / 8 ′ ′ 1/10''\text{ to }1/8'' 1/1 0 ′′ to 1/ 8 ′′ ) with waterproof adhesive, with grain running parallel in all plies. Used for heavy floor girders, window/door headers, and ridge beams.
Glue-Laminated Timber (Glulam) : Individual dimension lumber laminations ( 1.5 in 1.5\text{ in} 1.5 in thick for straight members, 0.75 in 0.75\text{ in} 0.75 in for curved shapes) bonded with structural adhesives. Glulam can be manufactured in virtually unlimited depths and lengths ( 20 to 100 + ft 20\text{ to }100+\text{ ft} 20 to 100 + ft ), with higher-grade laminations positioned at top and bottom outer faces where flexural tension and compression peak.
Fire Safety & Life-Safety Mandates for Light-Frame Wood
Under the International Building Code, light-frame wood construction is categorized as Type V (combustible interior and exterior framing) or Type III (combustible interior framing with noncombustible exterior masonry or concrete walls, typical of urban 5-over-1 or 5-over-2 podium buildings over a Type I-A concrete base). Because light-frame assemblies contain extensive concealed hollow spaces, the IBC mandates strict passive fire containment:
Fire Blocking (IBC Section 718.2)
Solid wood blocking ( 2 -inch 2\text{-inch} 2 -inch nominal lumber), structural panels, mineral wool, or gypsum board must be installed within concealed spaces to cut off concealed draft openings:
In concealed wall cavities horizontally at ceiling and floor levels.
At required floor and ceiling levels and in specified concealed-space locations; the common 10-foot interval concerns horizontal concealed-space separation, not a replacement for vertical floor-level fireblocking.
At all interconnections between vertical stud cavities and horizontal spaces created by soffits, dropped ceilings, cove ceilings, and stair framing.
Draft Stopping (IBC Section 718.3 & 718.4)
Draft stopping divides large concealed horizontal floor-ceiling plenums and attic spaces to prevent smoke and heat travel:
Floors : In non-sprinklered buildings, floor-ceiling spaces must be divided into compartments not exceeding 1 , 000 square feet 1,000\text{ square feet} 1 , 000 square feet . In sprinklered buildings, draft stopping in floors is generally waived.
Attics : In non-sprinklered Group R-1 and R-2 occupancies, attics must be divided into compartments not exceeding 3 , 000 square feet 3,000\text{ square feet} 3 , 000 square feet or divided along tenant separation demising walls.
Heavy Timber Construction (IBC Type IV-HT)
Heavy Timber construction (IBC Type IV-HT) utilizes large solid-sawn or glued-laminated timber elements without concealed combustible spaces. Heavy timber structures exhibit exceptional inherent fire endurance due to the predictable thermal physics of wood charring.
Prescribed Minimum Nominal Dimensions (IBC Chapter 6 / Table 2304.11)
To qualify as Type IV-HT, structural members must meet or exceed strict minimum cross-sectional dimensions:
Columns Supporting Floors : Minimum 8 ′ ′ × 8 ′ ′ 8'' \times 8'' 8 ′′ × 8 ′′ nominal ( 7.5 ′ ′ × 7.5 ′ ′ 7.5'' \times 7.5'' 7. 5 ′′ × 7. 5 ′′ actual).
Floor Beams & Girders : Minimum 6 ′ ′ × 10 ′ ′ 6'' \times 10'' 6 ′′ × 1 0 ′′ nominal ( 5.5 ′ ′ × 9.5 ′ ′ 5.5'' \times 9.5'' 5. 5 ′′ × 9. 5 ′′ actual).
Roof Columns : Minimum 6 ′ ′ × 8 ′ ′ 6'' \times 8'' 6 ′′ × 8 ′′ nominal ( 5.5 ′ ′ × 7.5 ′ ′ 5.5'' \times 7.5'' 5. 5 ′′ × 7. 5 ′′ actual).
Roof Beams & Arches : Minimum 4 ′ ′ × 6 ′ ′ 4'' \times 6'' 4 ′′ × 6 ′′ nominal ( 3.5 ′ ′ × 5.5 ′ ′ 3.5'' \times 5.5'' 3. 5 ′′ × 5. 5 ′′ actual).
Wood Floor Decking : Minimum 3 inches 3\text{ inches} 3 inches nominal solid sawn tongue-and-groove splined planks or 4 inches 4\text{ inches} 4 inches nominal laminated decking, covered with a 15 / 32 -inch 15/32\text{-inch} 15/32 -inch wood structural panel or 1 -inch 1\text{-inch} 1 -inch finished flooring.
Concealed spaces : Type IV-HT has specific limitations and exceptions. Consult the 2021 provisions for permitted concealed spaces and their required protection instead of treating all concealment as prohibited.
The Charring Phenomenon & Fire Resistance
When exposed to standard ASTM E119 fire temperatures exceeding 550 ∘ F 550^\circ\text{F} 55 0 ∘ F ( 290 ∘ C 290^\circ\text{C} 29 0 ∘ C ), the outer surface of heavy timber pyrolyzes, forming an expanding layer of porous charred carbon . This char layer acts as a natural, highly effective thermal insulator with extremely low thermal conductivity:
Predictable Char Rate : Structural wood chars at an empirical rate of approximately 1.5 inches per hour 1.5\text{ inches per hour} 1.5 inches per hour ( 0.025 to 0.030 inches per minute 0.025\text{ to }0.030\text{ inches per minute} 0.025 to 0.030 inches per minute for Douglas Fir and Southern Pine).
Reduced structural section : The char layer insulates wood behind it, but the fire design must account for effective char depth, the heated zone, residual section, adhesives and connections. The entire uncharred core cannot simply be assigned 100% ambient strength and stiffness.
Mass Timber Typologies & The 2021 IBC Expansion
The 2021 International Building Code expanded Type IV construction from a single category (Type IV-HT) into four distinct construction types, creating a revolutionary framework for tall mass timber buildings:
For Group B with the qualifying sprinkler conditions in the 2021 tables, IV-A can reach 18 stories/270 feet, IV-B 12/180, IV-C 9/85 , and IV-HT 6/85. Apply the detailed protection and exposure rules, not these dimensions alone. IV-A has extensive protection with specified exceptions; IV-B limits exposure, IV-C permits broader interior exposure, and IV-HT includes qualifying CLT and its own concealed-space provisions. Limits differ for other occupancies.
Engineered Mass Timber Products
Cross-Laminated Timber (CLT) : Fabricated by bonding alternating orthogonal layers (typically 3, 5, 7, or 9 plies) of kiln-dried dimension lumber with structural polyurethane adhesive. Alternating perpendicular grain orientations provide two-way spanning slab capabilities, high dimensional stability (reducing cross-grain dimensional movement), and high in-plane diaphragm shear capacity.
Nail-Laminated Timber (NLT) : Dimensional lumber stacked on edge and mechanically fastened with continuous nails or spikes. Excellent for one-way floor and roof decks.
Dowel-Laminated Timber (DLT) : Dimensional lumber stacked on edge and friction-locked with dried hardwood dowels. Contains zero metallic fasteners or glue adhesives, allowing rapid cutting with CNC timber routers.
High-Performance Mass Timber Connections
Traditional exposed steel bucket connections with large external through-bolts conduct fire heat rapidly into the interior of the timber, causing early joint failure. Modern mass timber engineering utilizes concealed high-performance connections :
Concealed steel connections can place insulating wood cover around hardware, but required cover, fasteners, plug details and fire endurance must be established by an approved design or test. A generic 1½–2-inch cover does not automatically create a 1- or 2-hour connection rating.
Fully Threaded Self-Tapping Screws (STS) : Engineered high-tensile steel screws installed at 45-degree angles to take combined shear and axial withdrawal forces, creating rapid, high-stiffness connections across mass timber panels.
Structural spans, member-depth ratios and preliminary capacities in this section are design-screening assumptions, not completed structural designs. Check loads, serviceability, fire rating, vibration, connections, bracing, durability and constructability with the engineer. IBC 2021 references ASCE 7-16; an exam-provided reference or a locally adopted edition may differ. Never transfer a numerical limit between editions or structural systems without checking its scope.