4.1 Daylighting Metrics: Spatial Daylight Autonomy (sDA) & Annual Sun Exposure (ASE)
ARE 5.0 Project Planning & Design PPD
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview & Schematic Design Process
1.1 ARE 5.0 PPD Format, Scoring & Case Study Navigation 1.2 The Schematic Design Phase & Multi-Discipline Workflow 1.3 Regulatory Framework: Navigating Codes, Standards & Jurisdictions
2 Chapter 2: Site Analysis, Topography & Soil Conditions
2.1 Site Topography, Grading, Slopes & Cut/Fill Calculations 2.2 Geotechnical Reports, Soil Classification & Foundation Selection 2.3 Site Hydrology, Drainage & Stormwater Management Neighborhood Context, Historic Settings & Site Integration
3 Chapter 3: Climate, Microclimate & Solar Design
3.1 Solar Geometry, Sun Angles & Sun Path Diagrams 3.2 Microclimate Analysis, Prevailing Winds & Passive Ventilation 3.3 Passive Solar Heating & Thermal Mass Strategies
4 Chapter 4: Sustainable Principles & Energy Standards
4.1 Daylighting Metrics: Spatial Daylight Autonomy (sDA) & Annual Sun Exposure (ASE) 4.2 Building Energy Standards: ASHRAE 90.1, IECC & Energy Use Intensity (EUI) 4.3 High-Performance Frameworks: LEED v4.1, Net Zero & Embodied Carbon
5 Chapter 5: Zoning Regulations & Land Use Controls
5.1 Zoning Envelopes: Setbacks, Floor Area Ratio (FAR) & Lot Coverage 5.2 Parking Requirements, Access & Site Circulation Planning 5.3 Environmental Regulations: Wetlands, Flood Zones & Brownfields
6 Chapter 6: Building Code Fundamentals: Occupancy & Construction Types
6.1 IBC Occupancy Classifications & Group Characteristics 6.2 Mixed Occupancy Strategies: Nonseparated, Separated & Accessory 6.3 IBC Construction Types I Through V & Fire-Resistance Ratings 6.4 Allowable Building Height & Area Calculations (IBC Tables 504 & 506)
7 Chapter 7: Means of Egress & Fire Protection
7.1 Occupant Load Determination & Egress Sizing (IBC Chapter 10) 7.2 Egress Components: Common Path, Travel Distance & Exit Separation 7.3 Passive Fire Protection: Fire Walls, Barriers & Smoke Partitions 7.4 Active Fire Suppression: Sprinklers, Standpipes & Fire Alarms
8 Chapter 8: Accessibility & Universal Design
8.1 Accessible Routes, Curb Ramps & Parking Layouts (ADA / ICC A117.1) 8.2 Interior Accessibility: Doors, Maneuvering Clearances & Corridors 8.3 Accessible Plumbing Facilities: Restrooms, Grab Bars & Fixture Layouts
9 Chapter 9: Structural Systems: Wood, Steel, Concrete & Masonry
9.1 Structural Selection & Spanning Rules of Thumb 9.2 Steel Framing Systems: Beams, Girders & Open-Web Joists 9.3 Concrete Framing Systems: One-Way, Two-Way & Post-Tensioned Slabs 9.4 Wood Systems: Light-Frame, Heavy Timber & Mass Timber (CLT)
10 Chapter 10: Lateral Force Resisting Systems & Foundations
10.1 Lateral Load Paths: Wind vs. Seismic Forces 10.2 Shear Walls, Braced Frames & Moment Frames 10.3 Shallow vs. Deep Foundation Systems: Footings, Mats, Piles & Caissons
11 Chapter 11: Building Envelope: Physics, Assemblies & Moisture Control
11.1 Envelope Thermal Performance: U-Values, R-Values & Thermal Bridging 11.2 Moisture Management: Vapor Retarders, Air Barriers & Water Resistive Barriers 11.3 High-Performance Wall & Roof Assemblies: Rainscreens & Inverted Roofs 11.4 Fenestration & Glazing: U-Factor, SHGC, Condensation Resistance & VT Interior Materials, Durability & Program Performance
12 Chapter 12: Mechanical & HVAC Systems
12.1 HVAC System Types: All-Air, Air-Water, All-Water & VRF Systems 12.2 Central Plant Equipment: Chillers, Boilers, Cooling Towers & Geothermal 12.3 Ductwork Distribution, Air Handling & Plenum Space Requirements 12.4 Indoor Air Quality, Ventilation Rates & ASHRAE 62.1 Baselines
13 Chapter 13: Plumbing, Electrical & Life Safety Systems
13.1 Domestic Water Supply & Pressure Boosting Systems 13.2 Sanitary Drainage, Venting & Fixture Count Calculations 13.3 Electrical Service, Transformers, Switchgear & Backup Generators 13.4 Lighting Design, Controls & Lighting Power Density (LPD) Limits
14 Chapter 14: Specialized Building Systems & Vertical Circulation
14.1 Architectural Acoustics: STC, NRC, RT60 & Noise Criteria (NC) 14.2 Elevator Systems: Traction vs. Hydraulic, Core Layout & Sizing 14.3 Building Telecommunications, Security & Building Automation Systems (BAS)
15 Chapter 15: Systems Integration & Coordination
15.1 Floor-to-Floor Height & Plenum Coordination (Structure + MEP + Architecture) 15.2 Structural Grid Planning & Spatial Adjacencies 15.3 Building Massing, Orientation & Envelope Integration 15.4 Case Study Strategy: Synthesizing Drawings, Code Sheets & Schedules
16 Chapter 16: Project Costs, Budgeting & Life-Cycle Analysis
16.1 Schematic Estimating Techniques: Area, Volume & Parametric Costs 16.2 Project Budgets: Contingencies, Overhead, Profit & Escalation 16.3 Life-Cycle Cost Analysis (LCCA) & Value Engineering
4.1 Daylighting Metrics: Spatial Daylight Autonomy (sDA) & Annual Sun Exposure (ASE)
Key Takeaways Explain This Topic AI
sDA measures annual useful daylight availability; ASE identifies extensive direct-sun exposure under specified thresholds.
LEED v4.1 glare documentation above 10% ASE differs from a universal pass/fail ceiling.
Daylight-control zones follow the chosen code edition, while useful penetration also depends on geometry and context.
Evaluate glare, daylight distribution and electric-light controls together; savings are project-specific.
Last updated: October 2026
Daylighting Fundamentals: Photometrics & Geometry
Daylighting design in the ARE 5.0 Project Planning & Design (PPD) division requires an architect to integrate optical physics, solar geometry, human visual comfort, and automated electrical lighting controls. Natural illumination reduces electric lighting power consumption, lowers chiller cooling loads, and improves circadian health and occupant productivity. However, uncontrolled daylight introduces visual glare and excessive solar heat gain, negating intended energy savings.
Photometric Units: Lux vs. Foot-Candles
Illuminance describes the total luminous flux incident on a unit surface area. Architects work with two primary photometric measurement systems:
Foot-Candle (fc): The imperial unit representing one lumen per square foot ( 1 fc = 1 lm/ft 2 1\text{ fc} = 1\text{ lm/ft}^2 1 fc = 1 lm/ft 2 ).
Lux (lx): The International System of Units (SI) metric representing one lumen per square meter ( 1 lx = 1 lm/m 2 1\text{ lx} = 1\text{ lm/m}^2 1 lx = 1 lm/m 2 ).
The mathematical conversion between the two units is based on the dimensional relationship between feet and meters ( 1 m 2 = 10.764 ft 2 1\text{ m}^2 = 10.764\text{ ft}^2 1 m 2 = 10.764 ft 2 ):
1 fc ≈ 10.764 lux ⟺ 1 lux ≈ 0.0929 fc 1\text{ fc} \approx 10.764\text{ lux} \quad \Longleftrightarrow \quad 1\text{ lux} \approx 0.0929\text{ fc} 1 fc ≈ 10.764 lux ⟺ 1 lux ≈ 0.0929 fc
For preliminary architectural schematic rules of thumb, designers use the simplified approximation: 1 fc ≈ 10 lux 1\text{ fc} \approx 10\text{ lux} 1 fc ≈ 10 lux (e.g., 30 fc ≈ 300 lux 30\text{ fc} \approx 300\text{ lux} 30 fc ≈ 300 lux ).
Typical Architectural Space / Task Target Maintained Illuminance (Foot-Candles) Target Maintained Illuminance (Lux) Visual & Programmatic Requirements
Corridors, Stairwells & Lobbies 10 − 15 fc 10 - 15\text{ fc} 10 − 15 fc 100 − 150 lux 100 - 150\text{ lux} 100 − 150 lux Safe egress circulation; low visual acuity
General Open Office & Classrooms 30 − 40 fc 30 - 40\text{ fc} 30 − 40 fc 300 − 400 lux 300 - 400\text{ lux} 300 − 400 lux Screen-based work and reading printed documents
Technical Drafting & Laboratories 50 − 75 fc 50 - 75\text{ fc} 50 − 75 fc 500 − 750 lux 500 - 750\text{ lux} 500 − 750 lux High-precision visual inspection and fine details
Surgical Suites & Precision Assembly 100 − 200 fc 100 - 200\text{ fc} 100 − 200 fc 1 , 000 − 2 , 000 lux 1,000 - 2,000\text{ lux} 1 , 000 − 2 , 000 lux Critical visual contrast; supplemental task luminaires
Outdoor Direct Sunlight (Overhead) 5 , 000 − 10 , 000 fc 5,000 - 10,000\text{ fc} 5 , 000 − 10 , 000 fc 50 , 000 − 100 , 000 lux 50,000 - 100,000\text{ lux} 50 , 000 − 100 , 000 lux Unfiltered direct beam solar radiation
Outdoor Overcast Day (Diffuse Sky) 500 − 2 , 000 fc 500 - 2,000\text{ fc} 500 − 2 , 000 fc 5 , 000 − 20 , 000 lux 5,000 - 20,000\text{ lux} 5 , 000 − 20 , 000 lux Hemispherical diffuse sky illumination
Daylight Factor (DF) vs. Climate-Based Daylight Modeling (CBDM)
Historically, daylight was quantified using the static Daylight Factor (DF) , defined as the ratio of internal horizontal illuminance ( E in E_{\text{in}} E in ) at a specific work plane point to simultaneous unobstructed exterior horizontal illuminance ( E ext E_{\text{ext}} E ext ) under a standardized CIE overcast sky:
DF = ( E in E ext ) × 100 % \text{DF} = \left( \frac{E_{\text{in}}}{E_{\text{ext}}} \right) \times 100\% DF = ( E ext E in ) × 100%
While simple, Daylight Factor has severe limitations in modern architectural practice:
Daylight factor compares indoor to simultaneous outdoor illuminance under a specified standard overcast sky. The CIE overcast sky is brighter toward the zenith, not uniform. It does not represent direct sun or annual climate variation; obstructions, surface reflectance and room geometry remain important.
Orientation Blindness: DF yields identical calculations whether a window faces Due North, Due South, East, or West.
Geographic Indifference: DF does not account for local weather data, sunny vs. overcast regional climates, or seasonal variations across the 8,760 hours of the year.
Climate-based daylight modeling uses hourly weather and solar positions to assess annual performance. It supports design and some certification pathways but is not mandated by every energy code for every building. Verify the actual control and analysis requirements for the selected code or rating system.
Daylight Delivery Strategies: Sidelighting, Toplighting & Light Shelves
Daylight is introduced into buildings through two primary architectural typologies: sidelighting (vertical façades) and toplighting (roof apertures).
Sidelighting Geometry: Primary & Secondary Daylit Zones
Energy codes define primary and sometimes secondary sidelighted control areas using prescribed geometry. The details differ by edition and code; use the supplied figure and definitions. A planning daylight-penetration ratio is not a replacement for those control-zone boundaries.
Primary Sidelit Daylight Zone: The floor area directly adjacent to vertical fenestration. It extends laterally along the glass for a distance equal to the window width plus 2 ft 2\text{ ft} 2 ft ( 0.6 m 0.6\text{ m} 0.6 m ) on each side, and extends perpendicularly into the space to a depth equal to the window head height ( 1.0 H 1.0H 1.0 H ) measured from the finished floor.
Secondary Sidelit Daylight Zone: The floor area immediately adjacent to the primary zone. It extends laterally the same width as the primary zone and extends perpendicularly from 1.0 H 1.0H 1.0 H to 2.0 H 2.0H 2.0 H into the interior.
As a foundational rule of thumb for standard vertical glazing without architectural enhancements, usable natural daylight penetrates inward to a depth of approximately 1.5 to 2.0 times the window head height 1.5\text{ to }2.0\text{ times the window head height} 1.5 to 2.0 times the window head height ( 1.5 H − 2.0 H 1.5H - 2.0H 1.5 H − 2.0 H ). Beyond 2.0 H 2.0H 2.0 H , daylight levels drop below task thresholds, requiring supplemental electric lighting.
Light Shelves: Physics and Sizing
A light shelf is a horizontal architectural projection mounted on a vertical façade that divides a window assembly into two functional zones: a lower "view window" below the shelf and an upper "daylight clerestory" above the shelf.
Dual Thermodynamic and Optical Function:
Exterior Shelf: Acts as a horizontal overhang, shading the lower view glass from direct high-angle summer sun. This mitigates perimeter glare and cuts cooling loads.
Interior Shelf: Acts as an optical bounce plane. Direct sun entering through the upper clerestory strikes the top surface of the interior shelf and reflects upward onto the ceiling. The diffuse ceiling plane then scatters light deep into the floor plate.
Performance Impact: An interior light shelf extends effective daylight penetration from 1.5 H 1.5H 1.5 H up to 2.0 H − 2.5 H 2.0H - 2.5H 2.0 H − 2.5 H , while evening out luminous contrast between the perimeter and core zones.
Design Rules:
Mounting Height: Positioned above standing eye level—typically 7 ft 7\text{ ft} 7 ft ( 2.13 m 2.13\text{ m} 2.13 m ) above the finished floor —to maintain unobstructed exterior views and prevent direct visual glare from the reflective shelf surface.
Reflectance: The upper surface must have a high-reflectance, non-specular diffuse matte white finish with a solar reflectance of ρ ≥ 0.85 \rho \ge 0.85 ρ ≥ 0.85 ( 85 % 85\% 85% ). Highly specular (mirror-like) finishes must be avoided because they produce concentrated caustic glare patterns on the ceiling.
Ceiling Finish: The room ceiling must be finished in flat matte white (reflectance ρ ≥ 0.80 − 0.90 \rho \ge 0.80 - 0.90 ρ ≥ 0.80 − 0.90 ) and slope upward away from the window to optimize light distribution.
Toplighting Delivery Strategies
Toplighting provides natural illumination from overhead, making it ideal for single-story structures, high-bay spaces, and the top floors of multi-story buildings:
Roof monitors can distribute daylight to deep spaces. North-oriented glazing in northern mid-latitudes often reduces midday direct sun, but early/late seasonal sun, bright sky, reflections and snow can still cause glare. Compare orientation, glazing, baffles, ceiling reflectance and electric-light controls; a roof form alone does not eliminate shadows or summer glare.
Tubular Daylighting Devices (TDDs / Light Pipes): Compact optical delivery systems consisting of an exterior clear roof collector dome, a highly reflective rigid tube (lined with silvered optical film featuring specular reflectance ρ > 98 % \rho > 98\% ρ > 98% ), and an interior ceiling diffuser lens. TDDs transfer natural daylight across unconditioned attic spaces or mechanical plenums over lengths of 20 to 30 ft 20\text{ to }30\text{ ft} 20 to 30 ft ( 6 − 9 m 6 - 9\text{ m} 6 − 9 m ) with minimal thermal gain or conductive heat loss.
IES LM-83 Dynamic Daylight Metrics: sDA and ASE
The Illuminating Engineering Society (IES) developed LM-83 (Approved Method: IES Spatial Daylight Autonomy and Annual Sun Exposure) to standardize climate-based daylight simulations. LM-83 evaluates space performance using two paired, complementary metrics: one measuring daylight sufficiency ( s D A sDA sD A ) and the other measuring glare and visual discomfort risk ( A S E ASE A SE ).
1. Spatial Daylight Autonomy ( s D A 300 / 50 % sDA_{300/50\%} sD A 300/50% )
Spatial Daylight Autonomy ( s D A 300 / 50 % sDA_{300/50\%} sD A 300/50% ) describes the sufficiency of daylight within an interior space across an entire year. It is mathematically defined as the percentage of the analyzed work plane area that receives at least 300 lux 300\text{ lux} 300 lux ( 28 fc 28\text{ fc} 28 fc ) of natural daylight for at least 50 % 50\% 50% of the operating hours throughout the year.
Calculation Parameters:
Sensor grid spacing: Maximum 2 ft × 2 ft 2\text{ ft} \times 2\text{ ft} 2 ft × 2 ft ( 0.6 m × 0.6 m 0.6\text{ m} \times 0.6\text{ m} 0.6 m × 0.6 m ) horizontal grid.
Sensor height: 30 inches 30\text{ inches} 30 inches ( 0.76 m 0.76\text{ m} 0.76 m ) above finished floor (standard seated task plane).
Operating hours: Standardized as 8:00 AM to 6:00 PM local time (10 hours daily, totaling 3,650 operating hours per year).
Dynamic blinds: Automated blind operation is modeled to close whenever direct solar beam penetration exceeds glare limits.
Performance Thresholds (LEED v4.1 & IES LM-83):
Nominally Acceptable Daylight: s D A 300 / 50 % ≥ 55 % sDA_{300/50\%} \ge 55\% sD A 300/50% ≥ 55% of the regularly occupied floor area (qualifies for 2 points under LEED v4.1 Daylight credit).
Preferred / Exemplary Daylight: s D A 300 / 50 % ≥ 75 % sDA_{300/50\%} \ge 75\% sD A 300/50% ≥ 75% of the regularly occupied floor area (qualifies for 3 points under LEED v4.1 Daylight credit).
2. Annual Sun Exposure ( A S E 1000 , 250 h ASE_{1000,250h} A S E 1000 , 250 h )
Annual Sun Exposure ( A S E 1000 , 250 h ASE_{1000,250h} A S E 1000 , 250 h ) quantifies the potential for visual discomfort, disabling glare, and localized solar overheating caused by excessive direct beam sunlight. It is defined as the percentage of the analyzed work plane area that receives direct sunlight exceeding 1 , 000 lux 1,000\text{ lux} 1 , 000 lux ( 93 fc 93\text{ fc} 93 fc ) for more than 250 operating hours 250\text{ operating hours} 250 operating hours per year.
Calculation Rules:
Evaluated on the same 2 ft × 2 ft 2\text{ ft} \times 2\text{ ft} 2 ft × 2 ft horizontal grid at 30 inches 30\text{ inches} 30 inches AFF.
Calculated strictly without operable window blinds or dynamic shades deployed (assumes all interior shades are completely retracted to evaluate the inherent architectural shading of the building envelope).
Counts only direct beam sunlight and direct circumsolar radiation; diffuse sky light is filtered out of the calculation.
For LEED v4.1 simulation pathways, high sDA indicates useful annual daylight. An ASE above 10% calls for identifying how the space addresses glare; it is not automatically a failed credit under that version. Distinguish this from earlier LEED criteria and from a project's own glare target. Full certification depends on the applicable rating-system version, analysis boundary, prerequisites and all credit requirements.
Glare Metrics: Daylight Glare Probability (DGP)
Visual discomfort occurs when excessive luminance contrast exists within an occupant's field of view—such as looking at a computer monitor adjacent to an unshaded window receiving direct sun.
Daylight Glare Probability (DGP) is the most robust empirical metric for predicting visual discomfort from daylight. Developed by Jan Wienold and Jens Christoffersen, DGP combines vertical eye illuminance ( E v E_v E v ) with source luminance contrast:
DGP = 5.87 × 10 − 5 E v + 9.18 × 10 − 2 log 10 ( 1 + ∑ i L s , i 2 × ω s , i E v 1.87 × P i 2 ) + 0.16 \text{DGP} = 5.87 \times 10^{-5} E_v + 9.18 \times 10^{-2} \log_{10} \left( 1 + \sum_{i} \frac{L_{s,i}^2 \times \omega_{s,i}}{E_v^{1.87} \times P_i^2} \right) + 0.16 DGP = 5.87 × 1 0 − 5 E v + 9.18 × 1 0 − 2 lo g 10 ( 1 + ∑ i E v 1.87 × P i 2 L s , i 2 × ω s , i ) + 0.16
Where E v E_v E v is vertical eye illuminance (lux), L s , i L_{s,i} L s , i is glare source luminance, ω s , i \omega_{s,i} ω s , i is source solid angle, and P i P_i P i is the Guth position index.
DGP Value Range Visual Comfort Classification Occupant Response & Architectural Action
DGP < 0.35 \text{DGP} < 0.35 DGP < 0.35 Imperceptible Glare Optimal visual comfort; occupants perceive space as naturally daylit without distraction.
0.35 ≤ DGP < 0.40 0.35 \le \text{DGP} < 0.40 0.35 ≤ DGP < 0.40 Perceptible Glare Noticeable brightness; acceptable for short durations; rarely prompts blind closure.
0.40 ≤ DGP < 0.45 0.40 \le \text{DGP} < 0.45 0.40 ≤ DGP < 0.45 Disturbing Glare Visual fatigue; occupants begin adjusting posture or manually deploying blinds.
DGP ≥ 0.45 \text{DGP} \ge 0.45 DGP ≥ 0.45 Intolerable Glare Severe visual distress; mandatory blind deployment; electric lights turned on while blinds remain closed.
Dynamic Controls: Dynamic Shading & Continuous Dimming
Designing a high-performance daylighting system requires coordinating architectural fenestration with automated electrical and shading controls.
Automated Dynamic Shading Controls
Under IES LM-83 simulation guidelines, spaces equipped with operable shades must follow a standardized shading deployment protocol:
Trigger Condition: Operable window shades are programmed to deploy automatically whenever direct sunlight strikes more than 2 % 2\% 2% of the analysis points within the space with an illuminance exceeding 1 , 000 lux 1,000\text{ lux} 1 , 000 lux .
Shade Optical Transmittance: When deployed, commercial fabric roller shades typically feature an open-weave openness factor of 1 % 1\% 1% to 3 % 3\% 3% and a visible transmittance of VT ≤ 0.05 \text{VT} \le 0.05 VT ≤ 0.05 ( 5 % 5\% 5% ), blocking direct beam transmission while admitting low-level diffuse light.
Electrochromic (Dynamic) Glazing: An alternative to motorized fabric blinds. Electrochromic glass uses low-voltage DC electric current ( 1 − 5 V 1 - 5\text{ V} 1 − 5 V ) to transition lithium ions between metal oxide layers, darkening the glass continuously from a clear state ( VT ≈ 0.60 \text{VT} \approx 0.60 VT ≈ 0.60 , SHGC ≈ 0.40 \text{SHGC} \approx 0.40 SHGC ≈ 0.40 ) down to a fully tinted state ( VT ≈ 0.01 \text{VT} \approx 0.01 VT ≈ 0.01 , SHGC ≈ 0.09 \text{SHGC} \approx 0.09 SHGC ≈ 0.09 ) without blocking views to the outdoors.
Continuous Dimming Daylight Harvesting Systems
Daylight harvesting systems measure ambient natural illumination and dim electric fixtures to maintain constant target illuminance ( 300 − 500 lux 300 - 500\text{ lux} 300 − 500 lux ):
Photosensor Types:
Closed-Loop Systems: The photosensor is mounted on the ceiling facing downward toward the work plane, measuring the combined illuminance of daylight and electric light. It adjusts electric output to keep total illuminance at the setpoint.
Open-Loop Systems: The photosensor faces outward toward the window or sky, measuring daylight alone and calculating proportional electric dimming.
Stepped vs. Continuous Dimming:
Stepped Switching (Bi-Level): Turns off banks of lamps or fixtures in discrete increments (e.g., 100 % → 50 % → 0 % 100\% \rightarrow 50\% \rightarrow 0\% 100% → 50% → 0% ). Occupants find sudden steps highly distracting, often overriding automated switches.
Continuous Dimming (Architectural Standard): Solid-state 0–10V or DALI (Digital Addressable Lighting Interface) LED drivers modulate electrical wattage smoothly and imperceptibly across a continuous curve down to 1 % to 10 % 1\%\text{ to }10\% 1% to 10% light output. Continuous dimming reduces lighting energy consumption by 30 % to 50 % 30\%\text{ to }50\% 30% to 50% in perimeter daylit zones while maintaining visual stability.
- Worked Scenario: Daylight Compliance for an Open Office
- Scenario Parameters
An architect is evaluating schematic daylighting performance for a 4 , 000 sq ft 4,000\text{ sq ft} 4 , 000 sq ft ( 371.6 m 2 371.6\text{ m}^2 371.6 m 2 ) open-plan architecture studio located in Chicago, Illinois. The studio dimensions are 80 ft 80\text{ ft} 80 ft east-west along south and north façades by 50 ft 50\text{ ft} 50 ft north-south depth. The south façade features 10 -ft 10\text{-ft} 10 -ft head-height windows equipped with exterior horizontal light shelves mounted at 7 ft 7\text{ ft} 7 ft AFF. The north façade features continuous 9 -ft 9\text{-ft} 9 -ft head-height clerestories.
A climate-based daylight simulation is executed per IES LM-83 using an hourly TMY3 weather file. A 2 ft × 2 ft 2\text{ ft} \times 2\text{ ft} 2 ft × 2 ft calculation grid at 30 inches 30\text{ inches} 30 inches AFF yields 1 , 000 discrete calculation points 1,000\text{ discrete calculation points} 1 , 000 discrete calculation points across the regularly occupied studio floor.
Step 1: Calculate Spatial Daylight Autonomy ( s D A 300 / 50 % sDA_{300/50\%} sD A 300/50% )
The simulation tallies the number of sensor points that achieve at least 300 lux 300\text{ lux} 300 lux for at least 50 % 50\% 50% of the 3,650 operating hours (8:00 AM to 6:00 PM), with automated blinds deploying per LM-83 protocols:
Qualifying sensor points: 780 points 780\text{ points} 780 points
s D A 300 / 50 % = ( 780 qualifying points 1 , 000 total points ) × 100 % = 78.0 % sDA_{300/50\%} = \left( \frac{780\text{ qualifying points}}{1,000\text{ total points}} \right) \times 100\% = 78.0\% sD A 300/50% = ( 1 , 000 total points 780 qualifying points ) × 100% = 78.0%
Because s D A 300 / 50 % = 78.0 % ≥ 75 % sDA_{300/50\%} = 78.0\% \ge 75\% sD A 300/50% = 78.0% ≥ 75% , the design achieves the Preferred / Exemplary Daylight tier.
Step 2: Calculate Annual Sun Exposure ( A S E 1000 , 250 h ASE_{1000,250h} A S E 1000 , 250 h )
The simulation tallies points receiving direct beam sunlight exceeding 1 , 000 lux 1,000\text{ lux} 1 , 000 lux for more than 250 hours 250\text{ hours} 250 hours annually, with all interior window shades fully retracted:
Points exceeding threshold: 60 points 60\text{ points} 60 points (located along the immediate south perimeter sill)
A S E 1000 , 250 h = ( 60 points 1 , 000 total points ) × 100 % = 6.0 % ASE_{1000,250h} = \left( \frac{60\text{ points}}{1,000\text{ total points}} \right) \times 100\% = 6.0\% A S E 1000 , 250 h = ( 1 , 000 total points 60 points ) × 100% = 6.0%