Study guide
10.2 Femur Selection: Right, Left, and Dual Femur Scanning
ARRT Bone Densitometry Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Orientation & the ARRT Blueprint
1.1 About the ARRT Bone Densitometry Examination 1.2 Eligibility, Structured Education, and Clinical Experience
2 Chapter 2: Osteoporosis, Bone Biology & Risk Factors
2.1 Osteoporosis: Definitions, Types, and WHO Diagnostic Criteria 2.2 Bone Functions, Structural Anatomy, and Bone Types 2.3 Bone Cells, the Remodeling Cycle, and Calcium Homeostasis 2.4 Risk Factors, Secondary Causes, and Bone-Compromising Medications
3 Chapter 3: Indications, Prevention & Treatment
3.1 The Bone Mass Measurement Act: Covered Indications and Coding 3.2 Prevention: Nutrition, Exercise, Smoking Cessation, and Fall Prevention 3.3 Osteoporosis Drug Therapy: Antiresorptive, Anabolic, and Hormonal Agents
4 Chapter 4: Patient Preparation, Support & Radiation Safety
4.1 Patient Support, Disabilities, Ergonomics, and Transfer Techniques 4.2 Patient Instructions: Explaining the Exam, Dose, Duration, and Motion Control 4.3 Patient History, Contraindications, and Pregnancy Screening 4.4 Scan Preparation: Patient Data Entry, Artifact Removal, and Infection Control 4.5 Radiation Safety in DXA: ALARA, Distance, and Dose Levels
5 Chapter 5: DXA Physics & Instrumentation
5.1 Physical Principles of Dual-Energy X-ray Absorptiometry 5.2 Beam Geometries: Pencil Beam and Fan Beam Systems 5.3 Fan-Beam Geometry: Source–Object–Detector Distances, Magnification, and Centering 5.4 The Scan Analysis Algorithm: Soft Tissue, Bone Edge Detection, BMC, Area, and BMD
6 Chapter 6: Measuring & Reporting Bone Mineral Density
6.1 Statistics for Densitometry: Mean, Standard Deviation, and Coefficient of Variation 6.2 T-Scores, Z-Scores, and Reference Database Selection 6.3 Clinical Indications for BMD Testing and the FRAX Tool 6.4 Vertebral Fracture Assessment and Trabecular Bone Score 6.5 Whole Body DXA, Body Composition, and Pediatric Scanning
7 Chapter 7: Quality Control, Precision & Equipment Management
7.1 Accuracy, Precision, and the Sources of Precision Error 7.2 Daily Quality Control, Phantoms, and Control Charts 7.3 In Vivo Precision Studies and RMS-SD Calculation 7.4 Determining and Applying the Least Significant Change 7.5 Maintenance, Repair, Relocation, Cross-Calibration, and Software Upgrades
8 Chapter 8: DXA Informatics & Data Management
8.1 DXA Informatics, DICOM, PACS, and Data Management
9 Chapter 9: Lumbar Spine DXA
9.1 Lumbar Spine Anatomy, Landmarks, and Regions of Interest 9.2 Lumbar Spine Scan Acquisition and ROI Edge Placement 9.3 Lumbar Spine: Compensating for Body Habitus, Variant Anatomy, Pathology, and Low Bone Density 9.4 Lumbar Spine Positioning: The Leg Block, Centering, and Common Challenges 9.5 Lumbar Spine Problems: Poor Bone Edge Detection and Obscured Intervertebral Spaces 9.6 Lumbar Spine: Variant Anatomy, Fractures, Degenerative Pathology, Calcification, and Surgery 9.7 Lumbar Spine Analysis: Vertebral Exclusion and Reporting Rules 9.8 Lumbar Spine Follow-Up Scans and Rate of Change
10 Chapter 10: Proximal Femur DXA
10.1 Proximal Femur Anatomy, Landmarks, and Regions of Interest 10.2 Femur Selection: Right, Left, and Dual Femur Scanning 10.3 Proximal Femur Scan Parameters and Compensation 10.4 Proximal Femur Positioning: Neck Rotation, Shaft Placement, and Positioning Aids 10.5 Proximal Femur Problems: Ischium, Short Neck, Arthritis, Fracture, and Hardware 10.6 Femoral ROI Analysis: Femoral Neck, Total Hip, and Ward's Area 10.7 Proximal Femur Follow-Up Scans and Rate of Change
11 Chapter 11: Forearm DXA
11.1 Forearm Anatomy, Landmarks, and Adjacent Structures 11.2 Forearm Indications and Side Selection 11.3 Forearm Length Measurement, Scan Parameters, and Positioning 11.4 Forearm Regions of Interest: One-Third, Mid, Ultradistal, and Total 11.5 Forearm Problems: Edge Detection, Artifacts, Low Bone Density, and Joint Disease 11.6 Scan Analysis: Region Placement, Window Level, and Reported Values 11.7 Forearm Follow-Up Scans and Rate of Change
12 Chapter 12: Cross-Site Artifacts & Clinical Integration
12.1 Recognition, Impact, and Management of DXA Artifacts 12.2 Clinical Interpretation, Serial Comparison, and Reporting
10.2 Femur Selection: Right, Left, and Dual Femur Scanning
Key Takeaways Explain This Topic AI
Dual femur scanning acquires sequential bilateral proximal femur scans, increasing diagnostic sensitivity by identifying bilateral T-score discordance and establishing a highly reproducible baseline for monitoring.
ISCD directs that when both hips are scanned, diagnostic classification uses the lowest T-score of either femoral neck or total hip and not the mean, while mean bilateral total hip BMD should be used for monitoring on repeat tests.
Averaging bilateral total hips reduces random positioning noise and precision error by a factor of square root of 2, significantly tightening the Least Significant Change (LSC) and allowing earlier detection of therapeutic response.
Severe hip osteoarthritis and metallic hardware artifactually elevate or invalidate DXA measurements; when bilateral degeneration or hardware distorts the hips, diagnosis must rely on the lumbar spine or 33% radius.
Under official ISCD pediatric positions, proximal femur DXA is strictly contraindicated in growing children and adolescents due to skeletal growth dynamics, open physes, and lack of reproducible pediatric hip reference databases; only PA lumbar spine and whole body less head (WBLH) are accepted.
Last updated: September 2026
10.2 Femur Selection: Right, Left, and Dual Femur Scanning
Quick Answer: Dual femur scanning acquires sequential DXA scans of both proximal femurs during one session. ISCD draws a sharp line between the two uses: when both hips have been scanned, diagnostic classification uses the lowest T-score of the right or left femoral neck or total hip and explicitly not the mean , while mean bilateral total hip BMD should be used for monitoring on repeat tests. Non-standard clinical challenges include severe hip osteoarthritis (hypertrophic osteophytes and sclerosis falsely elevate BMD, requiring exclusion of affected ROIs and reliance on the lumbar spine or 33% radius), total hip arthroplasty (metal components invalidate the scan, requiring scanning of the contralateral hip), and orthopedic pinning. In pediatric patients (under 20), proximal femur scanning is strictly contraindicated by the ISCD due to rapid skeletal growth, maturity variability, and lack of reproducible pediatric normative hip databases; pediatric evaluation is restricted to the PA spine and whole body less head (WBLH).
Dual Femur Scanning Protocols and Clinical Advantages
Dual femur densitometry involves scanning both proximal femurs consecutively during a single appointment, utilizing automated software that moves between hips without repositioning the patient:
Clinical Indications and Rationale
Detecting Asymmetry and Discordance: Up to 30%–40% of patients exhibit left-to-right BMD discordance exceeding 0.5–1.0 T-score standard deviations due to limb dominance, trauma, or osteoarthritis. Scanning both femurs identifies the true skeletal nadir, preventing diagnostic under-staging.
Improved Diagnostic Sensitivity: Evaluating bilateral femoral necks and total hips captures four validated candidate sites, identifying osteoporosis that would be missed on a unilateral hip.
Establishing a Superior Monitoring Baseline: Averaging bilateral total hips produces a combined metric with exceptional statistical stability.
The Mathematical Precision Advantage
In serial monitoring, precision error (% CV) determines the Least Significant Change (LSC) ( LSC = 2.77 × CV \text{LSC} = 2.77 \times \text{CV} LSC = 2.77 × CV ): Averaging bilateral total hips into a Mean Total Hip BMD cancels random positioning errors and quantum noise across independent scans, reducing precision error by a factor of 2 \sqrt{2} 2 (~1.414). A baseline precision error of 1.2% drops to ~0.85%, tightening the LSC and enabling earlier detection of true biological response to therapy.
ISCD Positions on Dual Femur Interpretation
For diagnosis: when both hips have been scanned, use the lowest T-score among the four candidate regions (left femoral neck, right femoral neck, left total hip, right total hip). ISCD states explicitly that the mean T-score or Z-score must not be used for diagnostic classification.
For monitoring: when both hips have been scanned on repeat tests, mean bilateral total hip BMD should be used . This is where the precision advantage of averaging is realized.
The distinction is deliberate. Averaging protects a monitoring comparison from random positioning noise, but it also conceals the lower of two hips — and diagnostic classification is defined by the weakest valid site, not the average one.
Serial monitoring can track either the Mean Total Hip or the lower individual Total Hip, maintaining the same protocol across follow-up scans.
- Parameter Unilateral Hip DXA Bilateral Dual Femur DXA
- Acquisition Time ~15–30 seconds ~30–60 seconds automated sequence
- Patient Setup Unilateral positioning Single setup with bilateral foot fixture
- Precision Error (% CV) 1.0%–1.5% at Total Hip 0.7%–0.9% at Mean Total Hip (≈ CV / √2)
- Least Significant Change (LSC) ~2.8%–4.1% ~1.9%–2.5% (tighter response detection)
- Diagnostic Sensitivity Moderate; risks missing discordance High; captures bilateral asymmetry and nadir
- Artifact Management Unilateral artifact invalidates study Contralateral hip available for diagnosis
- Non-Standard Hips and Challenging Pathologic Scenarios
- Severe Hip Osteoarthritis (Degenerative Joint Disease)
Osteoarthritis produces joint space narrowing, subchondral sclerosis, and hypertrophic marginal osteophytes:
Radiologic Impact: Sclerotic spurs project over the femoral neck and intertrochanteric regions, artificially elevating measured BMD and T-scores and masking osteoporosis.
Technologist Protocol: If severe spurring affects one hip, scan the contralateral hip. If both hips exhibit severe degenerative changes, the proximal femur must be excluded from diagnostic consideration, and the technologist must acquire the PA lumbar spine or 33% (one-third) radius of the non-dominant forearm .
Total Hip Arthroplasty (THA) and Metallic Hardware
Impact: Metallic stems, screws, and cement cause complete beam attenuation, invalidating edge detection.
Protocol: Scan the contralateral non-operated hip . If bilateral total hip replacements are present, central hip densitometry cannot be performed; scan the PA lumbar spine and 33% radius.
Clinical Presentation Artifact / Consequence Mandatory Action & Alternative Sites
Unilateral Hip Arthroplasty Metal stem attenuates beam completely Scan contralateral unoperated hip; if bilateral, scan spine & 33% radius
Unilateral Femoral Pinning Fixation screws artificially spike BMC Scan contralateral non-operated hip; do not shift ROI box
Severe Unilateral Osteoarthritis Inferior osteophytes falsely elevate BMD Scan contralateral hip; utilize uninvolved side
Severe Bilateral Osteoarthritis Bilateral osteophytes mask osteoporosis Exclude both hips; acquire PA lumbar spine and 33% radius
Prior Healed Fracture Asymmetric callus distorts anatomy Scan contralateral uninjured hip; callus distorts area and BMC
Pediatric Proximal Femur Scanning: ISCD Official Positions
ISCD Pediatric Official Position: Proximal femur DXA scanning is not recommended for diagnosis or monitoring in growing children and adolescents prior to skeletal growth completion and epiphyseal fusion.
Developmental Justifications
Dynamic Skeletal Growth: Non-linear growth alters the neck-shaft angle from infancy (~150°) through adolescence (~125°–130°), confounding automated edge-detection.
Growth Plate (Physis) Variability: Capital femoral and trochanteric physes display variable mineralization based on biological maturity.
Absence of Normative Databases: Universal, robust pediatric normative hip databases comparable to adult datasets do not exist.
Poor Precision: ROI placement on developing pediatric femurs produces high precision errors.
Approved Pediatric DXA Sites
In patients under age 20, densitometry must be performed using:
PA Lumbar Spine (L1–L4): Highly reproducible, responsive trabecular site with robust pediatric reference curves.
Whole Body Less Head (WBLH): Evaluates systemic mineralization while excluding the skull.
Pediatric Reporting Rules: Results must be expressed strictly in Z-scores adjusted for age, sex, and height-for-age Z-scores (HAZ), never T-scores.