Study guide
12.3 Permanent, Temporary, Leadless & Biventricular Pacemakers
ARRT Cardiac-Interventional Radiography CI
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 Eligibility, Structured Education & Clinical Experience 1.3 Content Outline & Study Plan
2 Patient Communication & Assessment
2.1 Pre-, Intra-, and Postprocedure Communication 2.2 History, Allergies, Medications & Team Communication 2.3 Screening, NPO, Education & Consent
3 Positioning, Access Assessment & Labs
3.1 Positioning & Vascular Access Assessment 3.2 Chemistry & Hematology Labs 3.3 Coagulation Studies & Arterial Blood Gas
4 Monitoring, Documentation & Contrast
4.1 Physiologic Monitoring in the Cath Lab 4.2 Support Equipment & Procedure Documentation 4.3 Contrast Agents, Indications & Contraindications
5 Medications & Sterile Technique
5.1 Anticoagulants, Antiplatelets & Thrombolytics 5.2 Vasoactives, Sedation & Emergency Medications 5.3 Asepsis, Sterile Technique & Hazardous Materials
6 Emergency Care
6.1 Contrast Reactions & Contrast-Induced Nephropathy 6.2 Cardiac Emergencies (MI, CHF, Arrhythmia, Tamponade, Shock) 6.3 Access-Site & Vascular Emergencies
7 Image Acquisition & Processing
7.1 Fluoroscopy Dose Rates & Pulse Modes 7.2 Digital Acquisition, Roadmapping & Projections 7.3 Post-Processing, Reconstruction & PACS
8 Injectors, Intravascular Imaging & Radiation Protection
8.1 Automatic Pressure Injectors 8.2 Ultrasound, IVUS, OCT & ICE Equipment 8.3 Patient Radiation Protection 8.4 Personnel ALARA, Monitoring & QC
9 Diagnostic Foundations
9.1 Cardiac Anatomy & Pathophysiology 9.2 Right & Left Heart Hemodynamics 9.3 Coronary Angiography, Dominance & Projections
10 Additional Diagnostic Imaging
10.1 Graft, Pulmonary, Aortic & Ventricular Angiography 10.2 ICE, Intravascular Imaging & Endomyocardial Biopsy 10.3 Flow Reserve (FFR, iFR, RFR)
11 Access Angiography & Hemodynamic Calculations
11.1 Peripheral & Access-Site Angiography 11.2 Stroke Volume & Cardiac Output (Fick, Thermodilution, Angiographic) 11.3 Valve Area (Gorlin, Hakki) & Shunt Calculations
12 Electrophysiology
12.1 Arrhythmia Detection & Cardioversion 12.2 Ablation for AF, Atrial Flutter & VT 12.3 Permanent, Temporary, Leadless & Biventricular Pacemakers 12.4 ICD Insertion & Lead Extraction
13 Access, Equipment & Closure
13.1 Access Methods & Ultrasound Guidance 13.2 Sheaths, Catheters, Guidewires & Manifold 13.3 Closure Devices, Pressure & Dressings
14 Suite Design & Procedure Complications
14.1 Interventional Suite & Hybrid OR 14.2 Recognition & Treatment of Procedure Complications
15 Percutaneous Intervention Basics
15.1 Coronary & Peripheral Angioplasty 15.2 Coronary & Peripheral Stent Placement 15.3 Coronary & Peripheral Atherectomy
16 Adjunctive PCI & Retrieval
16.1 Mechanical, Pharmacologic & Aspiration Thrombectomy 16.2 IVC Filters & Foreign-Body Retrieval 16.3 Pericardiocentesis
17 Mechanical Support & Advanced Devices
17.1 IABP & Catheter-Based Ventricular Assist Devices 17.2 ECMO, Intravascular Lithotripsy & Distal Embolic Protection
18 Structural Heart: Septal Defects & TAVR
18.1 PFO & ASD Closure 18.2 Ventricular Septal Defect Closure 18.3 TAVI/TAVR
19 Structural Heart: Valvuloplasty, TMVR & LAA
19.1 Valvuloplasty 19.2 Transcatheter Mitral Valve Repair 19.3 Left Atrial Appendage Closure
12.3 Permanent, Temporary, Leadless & Biventricular Pacemakers
Key Takeaways Explain This Topic AI
Permanent pacing uses axillary, subclavian, or cephalic venous access, a prepectoral pocket, and RV plus or minus RA leads, with fluoro to distinguish RV apex from septum.
Subclavian or axillary access can cause pneumothorax; later hardware problems include twiddler's syndrome, lead dislodgement, perforation, and pocket infection.
Temporary options are transcutaneous pads as a painful bridge and a balloon-tipped transvenous wire from the IJ or femoral vein into the RV for symptomatic bradycardia or complete heart block.
Leadless Micra-class devices are delivered from a large femoral venous sheath and deployed in the RV with no pectoral pocket, bringing perforation and retrieval issues instead of pocket infection.
CRT places a CS lead into an LV epicardial vein after an occlusive CS venogram and a phrenic-capture check; teaching indication is LBBB plus low EF, not a hidden ARRT cutoff.
Last updated: August 2026
Permanent, Temporary, Leadless & Biventricular Pacemakers
Pacing is Procedures 1.D hardware: a generator and a lead that can capture ventricle (and often atrium) when the patient's conduction will not. The CI technologist runs venous access under fluoro , proves lead position , builds or avoids a pocket , and knows when the problem is a pneumothorax , twiddler's syndrome , or infection rather than the battery looks fine. Walk indications, contraindications, access, equipment, image use, complications, and closure for each device class.
Quick Answer: Permanent pacing: axillary, subclavian, or cephalic vein, prepectoral pocket , RV ± RA leads, fluoro for apex versus septum . Temporary : balloon-tipped transvenous from IJ or femoral , or transcutaneous pads . Leadless (Micra-class) : femoral to RV , no pocket . CRT/BiV : CS lead to an LV epicardial vein after an occlusive CS venogram , watching for phrenic capture . Teaching CRT indication: LBBB plus low EF (guideline-level, not an ARRT cutoff).
Permanent pacemaker: indications through closure
Indications (teaching): symptomatic sinus-node dysfunction , high-grade AV block , and complete heart block — especially an infranodal escape. Asymptomatic isolated first-degree delay is not an implant lecture.
Contraindications / delays: active systemic infection when you can wait, pocket implant during bacteremia (how hardware becomes infected), and a patient who needs temporary pacing now while INR or infection is sorted.
Access. Axillary (often extra-thoracic, ultrasound or contrast-guided), subclavian (higher pneumothorax and subclavian-crush teaching), or cephalic cutdown (no needle in the lung, but a small vein). A contrast venogram through an ipsilateral IV shows the path and stenosis. Equipment: peel-away sheaths, active- or passive-fixation leads, a programmer, fluoro, and a pericardiocentesis tray if a helix goes too far.
Image use is fluoro from needle to helix: RAO for RV apex versus outflow, LAO for septum versus free wall (septal lead points posterior/spinal, free-wall lead points anterior/sternal — teaching geometry). RV apex is the classic stable site; septal / RVOT septum is chosen in many labs to avoid apical dyssynchrony. Know both; do not call a mid-septal lead dislodged because it is not on the diaphragm.
Leads and pocket. Single-chamber VVI : RV only. Dual-chamber DDD : RA + RV . The generator sits in a prepectoral subcutaneous pocket (submuscular in thin patients or when erosion is a concern). Closure is layered pocket closure, hemostasis, a pressure dressing, and arm precautions per lab — not a femoral collagen plug.
Complications you must recognize:
Pneumothorax (and hemothorax) after subclavian/axillary access — post-implant chest fluoro or film .
Perforation/tamponade from an RV lead helix.
Lead dislodgement (high threshold, loss of capture, a lead that no longer is apical or in the appendage).
Twiddler's syndrome: the patient rotates the generator in the pocket and reels the leads out .
Infection: pocket erythema, drainage, erosion, bacteremia — later an extraction problem (12.4).
Subclavian crush, hematoma, and venous stenosis.
Temporary pacing
Transcutaneous pads are the bridge in the room: anterior–posterior or anterior–lateral, capture current as needed, sedation because it hurts. They are not a week-long solution.
Temporary transvenous: a balloon-tipped flow-directed catheter from the internal jugular or femoral vein into the RV , for symptomatic bradycardia or CHB awaiting a permanent system or after inferior MI with nodal block that may recover. Image use: fluoro to prove RV, not PA and not coronary sinus. Never leave a balloon inflated in a wedge — this is a pacing lead, not a forgotten Swan. Complications: perforation, infection if the wire sits for days, and loss of capture when the patient moves. Closure is a temporary suture/sleeve at the neck or groin until the permanent implant or the wire comes out.
Leadless pacemakers (Micra-class)
Leadless devices (Micra-class teaching) are delivered through a large femoral venous sheath and deployed in the RV . There is no pectoral pocket and no transvenous lead in the SVC. That removes pocket infection and subclavian crush from the story and replaces them with femoral vascular injury , RV perforation/tamponade , and retrieval that is not a simple helix unscrew years later.
Indications teaching: patients who need ventricular pacing without a good pocket (anatomy, infection history) or who are VVI-appropriate. Dual-chamber leadless systems exist in evolution; do not claim ARRT tests a specific model year. Image use: fluoro plus contrast to confirm RV septal/apical deployment and to watch for effusion. Closure: femoral venous hemostasis after a large sheath — figure-of-8 or device, not a 5-Fr hold.
Biventricular pacing / CRT
Cardiac resynchronization therapy (CRT) adds a left-ventricular lead through the coronary sinus into a lateral or posterolateral LV epicardial vein so the LV is paced from the outside of the lateral wall, resynchronizing a left bundle-branch block (LBBB) pattern.
Teaching indication (guideline-level, not an unpublished ARRT EF cutoff ): HFrEF / low ejection fraction , wide LBBB , and heart-failure symptoms despite medical therapy. Do not implant CRT thinking it is a blood-pressure toy in a narrow-QRS, normal-EF patient.
Unique tech task: occlusive CS venogram — balloon-occlude the CS and inject so the venous tree appears; pick a target vein; avoid phrenic-adjacent laterals if possible. After the lead is in, pace and feel/see the diaphragm : phrenic capture means a lateral vein too close to the nerve — reposition. CS dissection, inability to cannulate, and lead dislodgement from a small vein are everyday CRT complications.
Leads: typically RA + RV + CS/LV . The RV lead still provides backup pacing and ICD function when the generator is a CRT-D (that pairing is the next section's ICD logic).
Device / leads / unique tech task
- Device Leads Unique tech task
- Permanent dual-chamber RA + RV Venogram access; fluoro apex vs septum ; build pocket
- Temporary transvenous Balloon-tipped RV IJ or femoral float under fluoro; pads as bridge
- Leadless (Micra-class) None in a pocket; RV implant Large femoral sheath , deploy in RV, watch perforation
- CRT / BiV RA + RV + CS/LV Occlusive CS venogram , lateral vein, phrenic capture test
- Worked case
CHB in holding, BP 70, transcutaneous pads capturing painfully. Place a balloon-tipped temporary from the IJ under fluoro into the RV, confirm capture, then implant a permanent dual-chamber system from the left axillary vein. Chest fluoro shows no pneumothorax. If the patient instead has LBBB, low EF, class III HF , plan CRT : CS venogram, LV lead, phrenic test. If the patient has no pocket real estate after prior infection, a leadless femoral RV implant is the conversation — still watch for tamponade.
Exam traps
Subclavian access without thinking pneumothorax .
Calling CRT an extra RV lead.
Skipping the occlusive CS venogram .
Ignoring phrenic capture on the LV lead.
Treating leadless as a pocket device.
Shocking CHB instead of pacing.
Leaving a temporary balloon wedged in a PA.