Study guide
10.3 Maxillofacial, Mandible & TMJ CT
ARRT Computed Tomography CT
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 ARRT CT Exam Facts, Format & Scoring 1.2 How to Study & Test-Taking Strategy for the CT Exam
2 Patient Assessment, Communication & Safe Handling
2.1 Pre-Scan Assessment — Scheduling, History, Lab Values & Communication 2.2 Patient Education, Consent, Ergonomics & Positioning for the Scan 2.3 Patient Monitoring, Accessory Devices, Medications & Infection Control
3 Contrast Media & Injection Procedures
3.1 Contrast Media Types, Properties & Special Considerations 3.2 Venipuncture, Administration Routes & Power Injection Techniques 3.3 Contrast Timing, Reactions & Postprocedure Care
4 CT Radiation Physics
4.1 X-ray Production & Target Interactions 4.2 X-ray Beam Characteristics & Geometry 4.3 Photon Interactions with Matter & Tissue Attenuation
5 Radiation Protection & Dose Management
5.1 Minimizing Patient Dose — Technical Parameters & Modulation 5.2 Shielding & Patient-Specific Dose Considerations (Pediatric/Adult/Pregnancy) 5.3 Dose Measurements, Reporting & Personnel Protection
6 CT Scanner Components & Imaging Parameters
6.1 CT Unit Components — Gantry, Detectors & Data Acquisition System 6.2 Core Imaging Parameters — kVp, mAs, Pitch & Collimation 6.3 Slice Thickness, Scan Planes & Field of View
7 Data Acquisition Modes & Image Reconstruction
7.1 CT Acquisition Modes — Sequential, Helical & Volumetric Scanning 7.2 Cine/Shuttle Acquisition & Dual-Energy CT 7.3 Reconstruction Algorithms — Filtered Backprojection vs. Iterative Reconstruction 7.4 Reconstruction Parameters — Slice Thickness, Interval & Interpolation
8 Postprocessing, Image Display & Informatics
8.1 Postprocessing — MPR, 3D Rendering & Quantitative Analysis 8.2 Image Display Fundamentals — Pixels, Matrix & Field of View 8.3 Windowing & Measurement Tools — W/L, W/W & Region of Interest 8.4 CT Informatics — PACS, DICOM, Networking & Downtime Procedures
9 Image Quality & Artifacts
9.1 Image Quality Metrics — Resolution, Noise & Uniformity 9.2 CT Number, QA/QC & Accreditation 9.3 Patient-Related Artifacts — Beam Hardening, Motion, Metal & Edge Gradient 9.4 Equipment Artifacts — Rings, Streaks, Tube Arcing & Cone Beam
10 Head CT Procedures
10.1 Brain & Cranium CT — Routine and Perfusion Imaging 10.2 Temporal Bone, Orbit & Sinus CT 10.3 Maxillofacial, Mandible & TMJ CT
11 Spine & Musculoskeletal CT
11.1 Spine CT — Cervical, Thoracic & Lumbosacral Protocols 11.2 CT Myelography & Postmyelogram Imaging 11.3 Extremity CT — Upper & Lower Extremity, Postarthrogram 11.4 Shoulder, Bony Pelvis & Hip CT
12 Neck & Chest CT
12.1 Neck CT — Larynx/Airway & Soft Tissue 12.2 Cardiac CT — Coronary Angiography, Calcium Scoring, Gating & TAVR 12.3 Chest CT — Mediastinum, Airway, Chest Wall & Esophagram 12.4 HRCT, Lung Nodules & Low-Dose Lung Cancer Screening
13 Abdominal CT Procedures
13.1 Multiphase Liver, Pancreas & Adrenal CT 13.2 Renal CT — Multiphase Kidney, Urogram & Stone Protocol 13.3 GI Tract CT & Spleen Imaging
14 Pelvic CT Procedures
14.1 Pelvis CT — Bladder, Cystogram & Reproductive Organs 14.2 CT Colonography & Colorectal Imaging
15 Vascular, Interventional & Trauma CT
15.1 CT Angiography & Vascular Procedures — CTA, CTV, Runoff, Dissection & PE 15.2 CT-Guided Interventional Procedures — Biopsy, Drainage & Aspiration 15.3 CT Trauma Protocols & Surgical Planning
10.3 Maxillofacial, Mandible & TMJ CT
Key Takeaways Explain This Topic AI
A true Le Fort fracture requires bilateral pterygoid plate involvement; Le Fort I/II/III are distinguished by the pyriform margin, inferior orbital rim, and zygomatic arch respectively
Zygomaticomaxillary complex (tripod) fractures and naso-orbito-ethmoid (NOE) fractures are related but separate classifications from the Le Fort system
The mandible behaves like a ring structure, so identifying one fracture should always prompt a search for a second fracture elsewhere on the ring
The bilateral parasymphyseal-plus-condylar fracture pattern is the classic guardsman fracture, typically from a direct blow to the chin
TMJ CT is acquired in both closed-mouth and open-mouth positions; CT is best for bony detail while MRI remains primary for evaluating disc position
Last updated: July 2026
Why This Topic Matters on the ARRT CT Exam
This section closes out the Head subcategory with ARRT's final three named leaf items: maxillofacial bones , dedicated mandible , and temporomandibular joints (TMJs) . Facial trauma classification (especially the Le Fort system) is one of the most heavily tested named-pattern topics in cross-sectional imaging, and the mandible and TMJ each require protocol decisions (panoramic reformats, dual mouth-position acquisition) that do not apply anywhere else in the Head cluster — making this content both trauma-heavy and technically distinct.
- Core Terms and Technique
- Maxillofacial CT (Facial Trauma Protocol)
Facial trauma CT is a thin-section (submillimeter), noncontrast axial helical acquisition spanning the entire facial skeleton (orbits through mandible), reconstructed with both bone and soft-tissue algorithms , then reformatted into coronal and sagittal planes plus 3D volume-rendered (VRT) images for surgical planning. Contrast is added only if a vascular injury (e.g., carotid or vertebral artery dissection from blunt neck/face trauma) is suspected.
Le Fort fracture classification describes three patterns of midface fracture, all unified by one requirement: a true Le Fort fracture must include a fracture through the pterygoid plates (bilaterally). Without pterygoid plate involvement, a fracture pattern that otherwise resembles a Le Fort is not classified as one.
Type Fracture plane Unique distinguishing CT finding Clinical description
Le Fort I Horizontal, through the maxilla above the tooth roots/hard palate Fracture through the anterolateral nasal aperture (pyriform margin) "Floating palate" — separates the alveolar ridge/palate from the rest of the maxilla
Le Fort II Pyramidal, through the nasal bones, medial orbital walls/floors, and inferior orbital rims to the maxilla Fracture through the inferior orbital rim "Floating maxilla"
Le Fort III Horizontal, at the level of the zygomatic arches through the orbits and nasofrontal suture Fracture through the zygomatic arch "Floating face" — complete craniofacial dissociation from the skull base
Two related but distinct fracture patterns are commonly tested alongside Le Fort:
Zygomaticomaxillary complex (ZMC) fracture (also called a "tripod" fracture) — separate from the Le Fort system — involves the zygomaticofrontal suture, zygomaticomaxillary buttress, zygomatic arch, and orbital floor.
Naso-orbito-ethmoid (NOE) fracture — comminution of the central midface and medial orbital walls, placing the medial canthal tendon and nasolacrimal duct at risk.
Dedicated Mandible CT
The mandible is best conceptualized as a ring structure — like the bony pelvis — so a fracture at one site frequently has a second fracture elsewhere on the ring, and the technologist/radiologist should always look for a paired fracture. Dedicated mandible CT uses thin axial acquisition with curved (panoramic-style) reformats plus 3D VRT to unroll the ring-shaped bone into a single interpretable image. Common fracture sites include the parasymphysis, body, angle, ramus, and condyle . A classic tested pattern is the "guardsman fracture" — bilateral parasymphyseal plus bilateral condylar fractures — typically from a direct fall or blow onto the point of the chin.
TMJ CT
TMJ CT is technically unique in the Head cluster because it is acquired in two mouth positions for each side: closed-mouth (teeth together) and open-mouth (maximal opening, or as tolerated in trauma), using thin sections (roughly 1–2.5 mm) angled in an oblique sagittal plane perpendicular to the long axis of the condyle .
Position Normal condyle location What abnormal positioning suggests
Closed-mouth Condyle centered within the glenoid (mandibular) fossa Anterior/posterior displacement suggests joint dysfunction
Open-mouth Condyle translates anteriorly to sit beneath the articular eminence Failure to translate (reduced excursion) suggests ankylosis or severe internal derangement
CT is the modality of choice for evaluating the bony components of the joint — condylar morphology, joint space narrowing, osteophytes, sclerosis, erosion, and true bony ankylosis. However, MRI remains the primary modality for evaluating the fibrocartilaginous disc position (anterior disc displacement with or without reduction) — a CT technologist must recognize when a clinical question about "the disc" actually requires an MRI referral rather than an additional CT mouth position.
Exam Scenario Walkthrough
A restrained driver in a high-speed motor vehicle collision undergoes facial trauma CT. The images show bilateral pterygoid plate fractures, fractures through the inferior orbital rims, and involvement of the nasal bones and medial orbital walls, sparing the zygomatic arches — a Le Fort II pattern. A second patient with an isolated blow to the chin shows bilateral parasymphyseal mandible fractures plus bilateral condylar fractures — the guardsman fracture pattern, prompting a careful search of the entire mandibular ring for any additional fracture. A third, non-trauma patient with chronic jaw pain and limited opening undergoes TMJ CT in both closed- and open-mouth positions; the open-mouth image shows the condyle failing to translate past the articular eminence, raising concern for ankylosis and prompting an MRI referral to evaluate disc position.
Takeaways
A true Le Fort fracture requires bilateral pterygoid plate involvement ; Le Fort I fractures the pyriform margin, Le Fort II the inferior orbital rim, and Le Fort III the zygomatic arch.
ZMC ("tripod") fractures and NOE fractures are related but separate classification systems from Le Fort.
The mandible behaves like a ring structure — always search for a second fracture when one mandible fracture is identified; the bilateral parasymphyseal-plus-condylar pattern is the classic "guardsman fracture."
Dedicated mandible CT uses curved panoramic reformats to make the ring-shaped bone easier to interpret in a single image.
TMJ CT is acquired in both closed- and open-mouth positions ; CT excels at bony detail (condyle, joint space, ankylosis) while MRI remains primary for evaluating disc position .