Study guide
24.1 Breast & Axilla
ARRT Sonography Primary
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts & Logistics 1.2 Scoring, Section Minimums & the August 2026 Cut-Score Change 1.3 Official Blueprint & Study Strategy
2 Patient Care: Ethics, Legal Practice & Communication
2.1 Ethical & Legal Aspects of Patient Care 2.2 Interpersonal Communication & Patient Education 2.3 Physical Assistance, Monitoring & Sonographer Ergonomics
3 Patient Care: Safety, Emergencies & Infection Control
3.1 Medical Emergencies & Critical Findings 3.2 Infection Control & Hazardous Materials 3.3 Ultrasound Safety & Interventional Procedure Care
4 Image Production: Transducers & the Ultrasound Beam
4.1 Piezoelectric Effect & Transducer Construction 4.2 Beam Configuration: Near Field, Far Field & Focus 4.3 Transducer Types, Selection, Care & Malfunctions
5 Image Production: Pulse Characteristics & Resolution
5.1 Pulse Characteristics: PRF, PRP, SPL & Duty Factor 5.2 Resolution: Axial, Lateral, Temporal, Elevational & Contrast 5.3 Frequency, Bandwidth, Q Factor, Power, Pressure, Intensity & Amplitude
6 Image Production: Imaging Modes & Doppler Principles
6.1 B-Mode & M-Mode Imaging 6.2 Spectral Doppler: Pulsed Wave vs Continuous Wave 6.3 Color Doppler & Power Doppler
7 Image Production: Optimization Controls
7.1 Power, Gain, TGC, Depth & Focal Zone 7.2 Frame Rate, Line Density, Dynamic Range, Harmonics & Compounding 7.3 Doppler Optimization Controls
8 Image Production: Sound–Tissue Interactions
8.1 Speed of Sound & the Range Equation 8.2 Acoustic Impedance, Reflection, Refraction & Scattering 8.3 Attenuation, Absorption & Intensity
9 Image Production: Signal Processing, Display & Bioeffects
9.1 Receiver, Signal Processing & Analog-Digital Conversion 9.2 Postprocessing, Magnification, Panoramic & 3D/4D Imaging 9.3 Bioeffects & Output Display Measures
10 Image Production: Image Evaluation & Artifacts
10.1 Criteria for Diagnostic Quality & Annotation 10.2 Grayscale Artifacts 10.3 Doppler Artifacts
11 Image Production: Real-Time Interpretation & Informatics
11.1 Real-Time Imaging, Echogenicity & Echotexture 11.2 Color & Spectral Analysis: Measurements and Waveforms 11.3 Imaging Informatics: HIS, RIS, EMR, PACS & DICOM
12 Procedures: Abdominal & Transplant Vasculature
12.1 Aorta, Its Branches & the IVC 12.2 Portal Venous System & Hepatic Vasculature 12.3 Liver & Renal Transplant Sonography
13 Procedures: Liver
13.1 Liver Anatomy, Variants & Examination Technique 13.2 Diffuse Liver Disease 13.3 Focal Liver Lesions
14 Procedures: Biliary System, Pancreas & Spleen
14.1 Gallbladder & Bile Ducts 14.2 Pancreas 14.3 Spleen
15 Procedures: Urinary Tract, GI Tract & Other Abdominal Structures
15.1 Kidneys & Ureters 15.2 Bladder & Prostate 15.3 GI Tract, Adrenals, Lymph Nodes, Hernias & Peritoneal Cavity
16 Procedures: First-Trimester Obstetrics
16.1 Early Gestation: Normal Development & Structures 16.2 First-Trimester Measurements, Dating & Maternal Anatomy 16.3 First-Trimester Abnormalities
17 Procedures: Second/Third-Trimester Biometry & Fetal Survey
17.1 Standard Biometry: BPD, HC, AC, FL & Growth Assessment 17.2 Fetal Anatomic Survey: Head, CNS, Face & Spine 17.3 Fetal Anatomic Survey: Heart, Chest, GI, GU, Skeleton & Fetal Position
18 Procedures: Chromosomal, Genetic & Structural Abnormalities
18.1 Chromosomal & Genetic Abnormalities 18.2 Major Structural Anomalies by System 18.3 Fetal Infection, Neoplasms & Hydrops
19 Procedures: Placenta, Amniotic Fluid, Cord & Cervix
19.1 Placenta: Normal, Previa, Abruption & Accreta 19.2 Amniotic Fluid Assessment & Growth Disorders 19.3 Umbilical Cord & Cervical Assessment
20 Procedures: Fetal Assessment, Doppler & Multiple Gestation
20.1 Biophysical Profile & Fetal Surveillance 20.2 Fetal & Uteroplacental Doppler 20.3 Multiple Gestations, Assisted Reproduction & Maternal Disease
21 Procedures: Gynecology — Uterus
21.1 Uterine Anatomy, Myometrium & Fibroids 21.2 Endometrium: Cyclic Changes, Hyperplasia & Cancer 21.3 Cervix & Congenital Uterine Anomalies
22 Procedures: Gynecology — Adnexa & Pelvis
22.1 Ovaries: Normal, Functional Cysts & Benign Masses 22.2 Ovarian Malignancy, Torsion & Fallopian Tubes 22.3 Cul-de-Sac, Vagina & Pelvic Floor
23 Procedures: Neck & Scrotum
23.1 Thyroid & Parathyroid 23.2 Salivary Glands & Neck Lymph Nodes 23.3 Scrotum & Testes
24 Procedures: Breast & Peripheral Vascular
24.1 Breast & Axilla 24.2 Venous Extremity Doppler 24.3 Carotid Doppler & Post-Catheterization Complications
25 Procedures: Pediatric, Interventional & Miscellaneous
25.1 Neonatal Head, Spine & Hip Sonography 25.2 Pediatric GI & Noncardiac Chest 25.3 Ultrasound-Guided Interventions, MSK & Superficial Masses
24.1 Breast & Axilla
Key Takeaways Explain This Topic AI
Breast ultrasound is first-line for women under 30, pregnant or lactating patients, and palpable lumps in dense breasts; it is an adjunct to mammography, not a replacement
A simple cyst is anechoic with an imperceptible wall and posterior acoustic enhancement — benign (BI-RADS 2), requiring no follow-up
Fibroadenoma is the most common solid breast mass in young women: oval, circumscribed, gently lobulated, wider-than-tall, and homogeneously hypoechoic
Malignant features include irregular shape, spiculated margins, taller-than-wide orientation, and posterior shadowing; invasive ductal carcinoma accounts for roughly 70-80% of breast cancers
- Suspicious axillary nodes show cortical thickening greater than 3 mm or loss of the echogenic fatty hilum
- Last updated: July 2026
The Role of Breast Ultrasound
Mammography remains the screening tool of choice, but breast ultrasound fills critical gaps. It is the first-line imaging study for women younger than 30 , for pregnant or lactating patients, and for evaluating palpable lumps in radiographically dense breasts , where fibroglandular tissue can obscure a mass on mammography. Ultrasound distinguishes cystic from solid lesions with very high accuracy, guides biopsies in real time, and involves no ionizing radiation. It is an adjunct , not a replacement, for mammography: microcalcifications — the hallmark of ductal carcinoma in situ — are a mammographic finding that ultrasound detects poorly.
Technique and Documentation
Use a high-frequency linear-array transducer (typically 12-18 MHz) for maximum near-field resolution. Key technique points:
Radial and antiradial scanning : scan along the long axis of the ducts (radial, like spokes of a wheel) and perpendicular to them (antiradial) to demonstrate intraductal pathology
Clock-face documentation : every lesion is reported by clock position (e.g., 3 o'clock, right breast) plus its distance in centimeters from the nipple
Position the patient supine or in contralateral posterior oblique with the ipsilateral arm raised above the head; a stand-off pad or a thick gel layer helps evaluate very superficial lesions
Image each lesion in two orthogonal planes, with and without calipers; add color Doppler to document vascularity, since malignant masses often show internal or penetrating vessels
Breast Anatomy
From anterior to posterior, the breast contains skin (normally under 3 mm thick — thickening suggests edema or inflammatory carcinoma), subcutaneous fat , the mammary (glandular) zone of 15-20 lobes drained by lactiferous ducts converging on the nipple, and the retromammary space separating glandular tissue from the pectoralis major fascia and chest wall. Cooper's ligaments (suspensory ligaments) are fibrous septa anchoring the skin to the underlying fascia; they normally appear as thin echogenic lines, but tethering or straightening of these ligaments suggests an invasive process. Fat is hypoechoic and glandular tissue is relatively echogenic — this contrast makes masses visible. The axillary tail of Spence extends glandular tissue toward the axilla and must be included in any complete survey. When describing a mass, always use the standardized descriptors: shape (oval, round, irregular), margin (circumscribed or not), orientation (parallel/wider-than-tall versus nonparallel/taller-than-wide), echo pattern , and posterior features (enhancement, shadowing, combined, or none).
Cystic Masses
A simple cyst meets all of these criteria: an anechoic interior, an imperceptible (thin, smooth) wall , and posterior acoustic enhancement , often with thin edge refraction shadowing at the lateral margins. A true simple cyst is benign ( BI-RADS 2 ) and requires no follow-up and no aspiration. A complicated cyst contains low-level internal echoes or debris but has no thick wall, septation, or solid component; it is probably benign ( BI-RADS 3 ) and is managed with short-interval (6-month) follow-up. A complex cystic-solid mass — thick wall or septa, an intracystic solid component, or mixed cystic and solid architecture — requires biopsy ( BI-RADS 4 ), because a minority prove to be cystic papillary carcinomas or necrotic solid tumors.
Fibroadenoma
The fibroadenoma is the most common solid breast mass in young women. Sonographically it is oval , circumscribed , gently lobulated, wider-than-tall (parallel orientation) , and homogeneously hypoechoic, often with mild posterior enhancement. After menopause it may involute and develop coarse "popcorn" calcifications.
Malignant Features
Malignant masses show the opposite morphology: irregular shape , non-circumscribed margins (spiculated, angular, or microlobulated), taller-than-wide orientation, marked hypoechogenicity, posterior acoustic shadowing , and surrounding architectural distortion with Cooper's ligament tethering. Invasive ductal carcinoma (IDC) is the most common breast malignancy (roughly 70-80% of cases); invasive lobular carcinoma is subtler and may present only as shadowing and distortion.
- Feature Typically benign Typically malignant
- Shape Oval, gently lobulated Irregular
- Margin Circumscribed Spiculated or angular
- Orientation Wider-than-tall (parallel) Taller-than-wide
- Posterior features Enhancement Shadowing
- Echogenicity Mildly hypoechoic Markedly hypoechoic
- Other Entities
An intraductal papilloma is the most common cause of bloody nipple discharge — a small solid nodule within a dilated duct near the nipple, best demonstrated with radial scanning. In men, gynecomastia (the most common male breast disorder) appears as flame-shaped or discoid retroareolar tissue with no discrete mass; male breast cancer typically presents as an irregular solid mass eccentric to the nipple. Axillary lymph nodes are benign when they retain an echogenic fatty hilum and a thin, uniform cortex; focal or diffuse cortical thickening greater than 3 mm or loss of the fatty hilum is suspicious for metastatic involvement.
BI-RADS and Biopsy
The Breast Imaging Reporting and Data System (BI-RADS) standardizes reporting: 0 = incomplete (needs additional imaging), 1 = negative, 2 = benign, 3 = probably benign (under 2% malignancy risk, 6-month follow-up), 4 = suspicious (biopsy; subdivided 4A/4B/4C by rising suspicion), 5 = highly suggestive of malignancy (95% or greater), and 6 = biopsy-proven malignancy. Ultrasound-guided core needle biopsy (typically a 14-gauge spring-loaded device) samples the mass under real-time visualization; a radiopaque clip is deployed at the biopsy site to mark it for follow-up or surgical localization. Compared with stereotactic guidance, ultrasound guidance is faster, uses no radiation, and is preferred whenever the lesion is visible sonographically.
Clinical Indications and Limits
Common indications for a diagnostic breast ultrasound include a palpable abnormality, evaluation of a mammographic finding, nipple discharge, breast pain with a focal trigger point, assessment of implants and peri-implant fluid, and axillary staging before breast surgery. During the exam, always correlate the imaging with the clinical history — prior surgery, trauma, lactation status, and hormone therapy all alter the expected appearance — and compare with any prior studies, since long-term stability (two years or more) is itself a benign feature. Remember the modality's blind spots: ultrasound is operator-dependent, and a normal ultrasound does not exclude malignancy when the mammogram or physical exam is suspicious, so discordant findings still warrant biopsy.