Study guide

12.5 Scrolls, RNase-Free Technique & Laser Capture Microdissection

ASCP Scientist in Histotechnology HTL

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Fixation Principles & Aldehydes

1.1 Fixation Principles, Tissue Autolysis & Reaction Kinetics 1.2 Aldehyde Fixatives & Formalin Chemistry 1.3 Fixation Artifacts, Under-Fixation & ASCO/CAP Guidelines

2 Chapter 2: Specialty Fixatives & Decalcification

2.1 Mercuric Chloride Fixatives: Zenker, Helly & B-5 2.2 Zinc Formalin & Picric Acid Fixatives 2.3 Coagulant Fixation & Monohydric Alcohol Fixatives 2.4 Carnoy Fluid, Acetone & Unfixed Transport Media 2.5 Decalcification Chemistry: Acids, Chelators & Kinetics 2.6 Decalcification Endpoints, Neutralization & Surface Decalcification

3 Chapter 3: Processing & Embedding Media

3.1 Dehydration & Clearing Solvents 3.2 Infiltration Media, Paraffin Properties & Plastics 3.3 Automated Processors & Protocol Optimization

4 Chapter 4: Microtomy & Sectioning Techniques

4.1 Embedding Centers & Diagnostic Tissue Orientation 4.2 Margin Inking, Mordanting & Embedding Quality Control 4.3 Rotary Microtome Engineering & Blade Geometry 4.4 Section Thickness, Flotation Bath & Slide Adhesives 4.5 Microtomy Artifacts & Troubleshooting

5 Chapter 5: Cryotomy & Specialized Sectioning

5.1 Cryostat Operation & Intraoperative Frozen Sections 5.2 Cell Blocks, Cytocentrifugation & Fluid Preparation 5.3 Hard Tissue & Plastic-Embedded Microtomy 5.4 Electron Microscopy Ultramicrotomy & Grid Contrasting 5.5 Papanicolaou & Cytologic Staining

6 Chapter 6: Routine Staining & Mounting

6.1 Dye Chemistry, Chromophores & Staining Mechanisms 6.2 Progressive & Regressive Hematoxylin Formulations 6.3 Eosin Counterstaining, Clearing & Coverslipping 6.4 Staining Instrumentation, Control Tissue & Special Stain QC

7 Chapter 7: Connective Tissue Stains

7.1 Collagen & Muscle Differentiation: Masson Trichrome & Movat 7.2 Elastic Fiber Demonstrations: Verhoeff-van Gieson & Aldehyde Fuchsin 7.3 Reticular Fibers, Fibrin & Muscle PTAH

8 Chapter 8: Carbohydrate, Lipid & Amyloid Stains

8.1 Glycogen & Epithelial Mucins: PAS & Diastase Digestion 8.2 Acid Mucosubstances: Alcian Blue & Colloidal Iron 8.3 Amyloid Detection: Congo Red & Polarized Light 8.4 Lipid Histochemistry: Lysochromes & Osmium Tetroxide

9 Chapter 9: Microorganism Demonstration

9.1 Bacteria & Spirochetes: Gram, Warthin-Starry & Giemsa 9.2 Acid-Fast Bacilli: Ziehl-Neelsen, Kinyoun, Fite & Auramine 9.3 Fungal Demonstration: GMS, PAS & Mucicarmine

10 Chapter 10: Pigments, Minerals & Neuropathology

10.1 Hemosiderin & Melanin: Perls, Fontana-Masson & Bleaching 10.2 Bile, Lipofuscin & Exogenous Pigments 10.3 Minerals & Metals: Calcium, Copper & Urate Crystals 10.4 Neurohistology, Argyrophilic Silver & Myelin Stains 10.5 Skeletal Muscle Enzyme Histochemistry & Fiber Typing

11 Chapter 11: Immunohistochemistry Principles & Methodology

11.1 Antibodies, Epitopes & Antigen Retrieval (HIER and PIER) 11.2 Detection Systems, Polymer Technology & Chromogens 11.3 IHC Controls, Artifacts & Quality Troubleshooting

12 Chapter 12: Advanced Molecular & Immunofluorescence

12.1 Diagnostic Direct Immunofluorescence: Renal & Skin Biopsies 12.2 In Situ Hybridization: FISH, CISH & RNAscope 12.3 Molecular Pre-Analytics: Cold Ischemia & Fixation Windows 12.4 FFPE Extraction, Molecular Decalcification & Tumor Enrichment 12.5 Scrolls, RNase-Free Technique & Laser Capture Microdissection

13 Chapter 13: Laboratory Mathematics & Reagent Chemistry

13.1 Percent Solutions, Hydration Calculations & Dilutions 13.2 Molarity, Normality & Equivalent Weights 13.3 Buffer Systems, pH Adjustment & Standardization 13.4 Ancillary Laboratory Equipment, Water Quality & Solvent Recovery

14 Chapter 14: Laboratory Safety & Regulatory Standards

14.1 OSHA Formaldehyde Standard, Engineering Controls & PPE 14.2 Hazard Labeling, Flammable Storage, Waste & Spill Response 14.3 Biological Hazards, Infection Control & Ergonomics 14.4 CLIA '88 Regulations & CAP Accreditation Requirements

15 Chapter 15: Microscopy, Tissue Identification & Bone Marrow Preparation

15.1 Light Microscopy, Optics & Specialized Illumination 15.2 Normal Histology & Diagnostic Tissue Identification 15.3 Bone Marrow & Hematopoietic Specimen Preparation

16 Chapter 16: Laboratory Management, Education & Exam Strategy

16.1 Laboratory Operations, Leadership & Quality Improvement 16.2 Educational Methodology & Competency Assessment 16.3 ASCP BOC HTL Exam Mechanics, Scoring & Comprehensive Review

12.5 Scrolls, RNase-Free Technique & Laser Capture Microdissection

Key Takeaways Explain This Topic AI

Scrolls are thick 5 to 10 micrometer curls cut directly into a nuclease-free tube, bracketed by hematoxylin and eosin bookend sections that confirm the target lesion is still present in the block.

RNase-free microtomy requires a dedicated decontaminated area, a fresh blade for every block, nuclease-free water, and gloves changed between specimens, because ribonucleases are ubiquitous and heat-stable.

Macrodissection scrapes a marked region from an unstained slide using a matching hematoxylin and eosin roadmap, and is the routine way to reach a 20 to 30 percent neoplastic cellularity threshold.

Laser capture microdissection requires special membrane-coated slides, minimal or rapid staining, complete dehydration, and no coverslip, because a coverslip and aqueous mountant make capture impossible.

Infrared systems melt a thermoplastic film onto the target and lift it off, while ultraviolet systems cut around the target and catapult or drop it into a collection cap.

Last updated: September 2026

1. Where the Histotechnologist Sits in the Molecular Workflow

When a molecular laboratory reports that a specimen "failed extraction" or that "tumor content was insufficient," the cause is almost always something that happened at the microtome. The ASCP BOC content outline places preparation for molecular testing under Embedding and Microtomy and marks it HTL only , listing three specific examples: RNase-free areas, scrolls, and laser capture microdissection .

2. Scrolls (Curls) for Nucleic Acid Extraction

A scroll , also called a curl, is a thick paraffin section cut directly into a labeled nuclease-free microcentrifuge tube rather than floated onto a slide.

Standard scroll protocol

Face the block and discard the facing ribbon.

Cut a leading hematoxylin and eosin bookend at routine thickness onto a slide.

Cut the requested scrolls , typically 5 to 10 micrometers each, and drop them straight into the tube using clean forceps or a fresh applicator stick. The number of scrolls is set by the tissue surface area on the block face: a large resection may need two or three curls, a small core biopsy may need eight or ten.

Cut a trailing hematoxylin and eosin bookend.

Review both bookends. If the lesion is present on the leading slide but exhausted on the trailing slide, part of the collected material contained no tumor, and the cellularity estimate must be revised.

Important

The bookend sections are not a formality. They are the only evidence that the material in the tube actually contains the lesion the molecular assay is being asked about, and they document how much target tissue remains in the block for repeat or reflex testing.

Why thicker sections

Scrolls are cut thicker than diagnostic sections because the goal is nucleic acid yield per section , not optical resolution. There is no water bath, no slide, and no staining, so the section thickness is limited only by what the microtome can cut cleanly.

3. RNase-Free and Contamination-Free Microtomy

Ribonucleases are present on skin, in dust, and on laboratory surfaces, and they are heat stable and refold after autoclaving . DNA carryover between blocks is equally damaging because modern sequencing panels amplify from very small inputs.

Control Practice

Dedicated area A designated microtome and bench used for molecular cutting, physically separated from routine sectioning

Surface decontamination Wipe microtome, forceps, and bench with a commercial RNase-inactivating reagent or 10 percent bleach followed by nuclease-free water or alcohol

Fresh blade A new blade or a clean, previously unused blade facet for every block, never a shared facet

Water Nuclease-free or molecular-grade water; ideally no flotation bath at all, using dry pickup or a disposable bath

  • Gloves Changed between every block; hands never touch the block face or the section
  • Consumables Nuclease-free tubes, filter tips, and disposable forceps or applicator sticks

Order of work Cut low-tumor-burden and precious specimens before high-tumor-burden blocks to limit carryover risk

4. Macrodissection: The Everyday Enrichment Method

Most tumor enrichment in a hospital laboratory is done by hand.

The pathologist circles the target region on a hematoxylin and eosin slide and estimates neoplastic nuclei as a percentage of total nuclei.

The technologist aligns unstained serial sections against the marked slide, transferring the outline to the back of the unstained slide.

The region is scraped off with a sterile scalpel blade directly into a nuclease-free tube, using a fresh blade for each case.

Macrodissection routinely lifts a specimen from below an assay threshold to above it. Common minimum neoplastic cellularity requirements sit near 20 percent , with some panels requiring 30 percent or more .

5. Laser Capture Microdissection

When the target is a structure rather than a region, such as individual glomeruli, a few hundred tumor cells, or an amyloid deposit, hand scraping is not precise enough. Laser capture microdissection (LCM) isolates a microscopic population under direct visual control.

5.1 Slide preparation is the technologist's job

Requirement Reason

Membrane slides (polyethylene naphthalate or similar) or plain uncharged glass, per platform The membrane supports the excised fragment; charged slides can hold tissue too tightly for capture

Minimal or rapid staining — rapid hematoxylin and eosin, methyl green, or cresyl violet Long aqueous staining leaches nucleic acid and degrades RNA

Complete dehydration and air drying before capture Residual moisture prevents film adhesion and causes incomplete cuts

  • No coverslip and no mountant The laser and capture cap must reach the tissue surface directly
  • Sections about 5 to 8 micrometers Thick enough for yield, thin enough for a clean laser cut
  • 5.2 The two platform families

Platform Mechanism Notes

Infrared capture A near-infrared laser melts a thermoplastic transfer film on a cap placed over the target; the melted polymer bonds the cells, and lifting the cap removes them Gentle, no cutting beam through the tissue; well suited to small clusters

Ultraviolet cutting A focused ultraviolet laser ablates a path around the target, and the isolated piece is either catapulted upward into a cap or dropped by gravity into a tube Precise contour cutting; suited to larger or irregular structures

  • 5.3 Clinical applications
  • Pure tumor populations for sequencing when tumor is admixed with abundant stroma or inflammatory cells
  • Individual glomeruli for renal research and for proteomic analysis

Amyloid subtyping , where deposits are captured and identified by liquid chromatography with tandem mass spectrometry

  • Single-population transcriptomics , where contaminating cell types would obscure the signal
  • 5.4 Verification

After capture, the operator inspects both the cap (target present) and the residual slide (target absent) to document that the intended cells were actually removed. That before-and-after check is the quality control record for the dissection.

Loading diagram... Molecular Block Preparation Decision Pathway