Study guide

5.3 Quality Assurance, Quality Control & Preanalytical Risk Management

ASCP Phlebotomy Technician PBT

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Patient Identification, Preparation & Equipment

1.1 Patient Identification & Requisition Verification 1.2 Phlebotomy Equipment, Needles & Antiseptics 1.3 Order of Draw, Additives & Tube Inversions 1.4 Site Selection, Vein Palpation & Skin Preparation

2 Chapter 2: Venipuncture & Capillary Skin Puncture Techniques

2.1 Standard Evacuated Tube Venipuncture Step-by-Step 2.2 Winged Infusion Sets & Difficult Vein Access 2.3 Capillary / Skin Puncture Protocols & Order of Draw 2.4 Pediatric & Geriatric Special Populations

3 Chapter 3: Preanalytical Complications & Special Blood Collections

3.1 Preanalytical Complications & Failure to Draw 3.2 Blood Culture Collection Protocols & Contamination Prevention 3.3 Special Blood Collections (Timed, Fasting, GTT, TDM) 3.4 Hemolysis, Clotting & Specimen Integrity Factors

4 Chapter 4: Specimen Transport, Processing & Storage

4.1 Specimen Labeling, Barcoding & Chain of Custody 4.2 Specimen Transport, Temperature & Light Sensitivity Requirements 4.3 Centrifugation, Aliquoting & Specimen Storage 4.4 Specimen Acceptability & Rejection Criteria

5 Chapter 5: Laboratory Operations, Safety & Regulatory Compliance

5.1 Infection Control, Standard Precautions & Bloodborne Pathogens 5.2 Laboratory Safety, Chemical Hygiene & Waste Disposal 5.3 Quality Assurance, Quality Control & Preanalytical Risk Management 5.4 Legal, Ethical & Regulatory Considerations (HIPAA, CLIA, OSHA) 5.5 Interprofessional Communication & Patient Interaction

6 Chapter 6: Circulatory System Anatomy & Physiology

6.1 Vascular Anatomy & Upper Extremity Vein Selection 6.2 Composition of Blood & Cellular Elements 6.3 Hemostasis, Coagulation Cascade & Anticoagulant Actions

7 Chapter 7: Point-of-Care Testing (POCT) & CLIA-Waived Procedures

7.1 Point-of-Care Testing (POCT) & CLIA-Waived Principles 7.2 POCT Quality Control, Calibration & Maintenance 7.3 Common POCT Procedures (Glucose, Coagulation, Hemoglobin/Hematocrit)

8 Chapter 8: Non-Blood Specimen Collection & Special Handling

8.1 Urine Specimen Collection Protocols & Types 8.2 Stool, Sputum & Throat Swab Collections 8.3 Cerebrospinal Fluid, Synovial & Other Body Fluids Handling

5.3 Quality Assurance, Quality Control & Preanalytical Risk Management

Key Takeaways Explain This Topic AI

Quality Assurance (QA) encompasses the overall operational framework ensuring high-quality healthcare outcomes, whereas Quality Control (QC) consists of specific technical procedures evaluating instrument accuracy and precision.

Over 70% of all laboratory diagnostic errors occur during the preanalytical phase, making phlebotomist adherence to collection, identification, and handling protocols critical to patient safety.

Delta checks compare a patient's current laboratory result with their previous baseline result to flag sudden, clinically improbable shifts that may indicate sample mix-ups or acute physiological changes.

Levey-Jennings charts plot daily Quality Control values against statistical limits; Westgard rules provide specific criteria (such as 1-3s or 2-2s) to identify random or systematic analytical errors.

Maintenance logs for blood storage refrigerators, freezers, centrifuges, and incubators must be updated daily, with centrifuge tachometer speed calibration performed semi-annually.

Last updated: July 2026

Quality Assurance, Quality Control & Preanalytical Risk Management

Delivering accurate laboratory test results requires systematic quality management across all diagnostic operations. In laboratory medicine, errors can cause misdiagnoses, delayed treatments, or inappropriate therapies. Phlebotomists play a vital role in quality management because test accuracy depends directly on specimen integrity.

Quality Assurance (QA) vs. Quality Control (QC)

Quality Assurance (QA) : An overall, institution-wide program that establishes policies, protocols, and continuous monitoring to ensure healthcare services consistently meet defined standards of excellence. QA encompasses patient preparation, turnaround time tracking, specimen transport conditions, customer satisfaction, and staff competency assessments.

Quality Control (QC) : Specific technical procedures used to verify that a specific laboratory instrument or assay performs within pre-established precision and accuracy limits. QC involves regularly testing control materials (samples containing known analyte target values) alongside patient specimens.

Total Testing Process & Preanalytical Risk Management

The Total Testing Process (TTP) describes the complete path of a diagnostic sample across three operational phases: [1. PREANALYTICAL PHASE] -------> [2. ANALYTICAL PHASE] -------> [3. POSTANALYTICAL PHASE]

  • Test ordering - Instrument calibration - Result verification
  • Patient ID & Fasting Prep - Reagent mixing - Critical value calls
  • Specimen draw & order of draw - Sample analysis - EMR result entry
  • Centrifugation & transport - QC evaluation - Specimen archiving
  • The Preanalytical Phase Risk

Extensive clinical research demonstrates that more than 70% of all diagnostic laboratory errors occur during the PREANALYTICAL phase . Because phlebotomists directly execute preanalytical tasks, strict adherence to standardized phlebotomy techniques is the single most effective defense against diagnostic errors.

Common Preanalytical Errors & Causes

Error Type Description & Primary Causes Impact on Laboratory Results

Hemolysis Rupture of RBCs releasing hemoglobin into plasma. Caused by small needle (25G), excessive suction, shaking tubes, or drawing hematomas. Falsely elevates Potassium , LDH , AST, Iron, Magnesium; invalidates CBC.

Hemoconcentration Increase in concentration of cellular elements and proteins. Caused by leaving tourniquet on >1 minute or arm pumping. Falsely elevates RBCs , Hemoglobin , Total Protein , Calcium, Cholesterol.

Clotted Specimen Micro-clot formation in anticoagulated tubes. Caused by delayed or insufficient tube inversion. Invalidates CBC (falsely low platelet/WBC count); clogs analyzers.

Specimen Contamination Cross-contamination of tube additives due to non-compliance with CLSI Order of Draw. EDTA carryover falsely elevates Potassium and depresses Calcium.

Underfilled Tubes Failure to achieve proper blood-to-additive ratio (e.g., Light Blue citrate 9:1 ratio). Excess anticoagulant dilutes plasma, falsely prolonging PT/PTT coagulation times.

Lipemia Milky serum/plasma caused by high blood triglycerides from non-fasting patient. Interferes with spectrophotometric chemistry measurements.

Delta Checks & Patient Result Validation

A Delta check is an automated Laboratory Information System (LIS) algorithm that compares a patient's current test result with their most recent previous result for the exact same analyte.

If the difference (delta) exceeds pre-set limits, the LIS flags the result to alert staff to potential errors:

Patient Misidentification : Sample collected from wrong patient.

Contaminated Draw : Blood drawn above an active IV line.

Additive Carryover : EDTA tube drawn prior to chemistry tube.

Acute Clinical Change : Real physiological events (e.g., internal hemorrhage).

Levey-Jennings Charts & Westgard Multirule Evaluation

Daily QC values are plotted on Levey-Jennings (L-J) charts , which display the target mean flanked by standard deviation boundary lines (±1SD, ±2SD, ±3SD).

Accuracy : Closeness of a measured value to its true target value.

Precision : Reproducibility of repeated measurements.

Trend : Gradual drift of QC values in one direction over 6+ runs (e.g., reagent aging).

Shift : Abrupt change establishing a new mean on one side over 6+ runs (e.g., new calibrator lot).

Westgard Multirules

Westgard Rule Definition Error Type & Action

1-2s One QC value exceeds ±2SD. WARNING RULE ONLY . Do not reject run; review other rules.

1-3s One QC value exceeds ±3SD. REJECT RUN . Caused by Random Error (e.g., air bubble).

2-2s Two consecutive QC values exceed same +2SD or -2SD. REJECT RUN . Caused by Systematic Error (e.g., calibration drift).

R-4s One value exceeds +2SD and another exceeds -2SD in same run. REJECT RUN . Caused by Random Error .

4-1s Four consecutive values exceed +1SD or -1SD on same side. REJECT RUN . Caused by Systematic Error .

10x Ten consecutive values fall on one side of mean. REJECT RUN . Caused by Systematic Error .

Equipment Maintenance Logs & Calibration

Equipment must be monitored and documented in daily maintenance logs:

Blood Bank Refrigerators : Maintained strictly between 1°C and 6°C (with continuous alarms).

Routine Refrigerators : Maintained between 2°C and 8°C .

Freezers : Maintained at -20°C or lower (-80°C for ultralow freezers).

Incubators : Maintained at 37°C ± 0.5°C .

Centrifuge Speed Calibration : Centrifuge rotational speed (RPM) must be verified semi-annually (every 6 months) using a calibrated optical photo-tachometer .

Centrifuge Balancing : Load tubes symmetrically (equal volume/weight directly opposite) to prevent breakage and severe vibration.

Clinical Scenario: EDTA Carryover Triggering Delta Check

A phlebotomist draws a Lavender (EDTA) tube before a Gold (SST) chemistry tube. The Gold tube shows a potassium result of 7.4 mEq/L (baseline 4.2 mEq/L) and a calcium result of 5.1 mg/dL (baseline 9.5 mg/dL). The LIS triggers a Delta check flag . Recognizing the classic EDTA carryover pattern (high K+, low Ca2+), the technician cancels the result and requests a redraw in correct Order of Draw, which yields normal values.

Common Exam Traps

Exam Trap 1: Over 70% of laboratory errors occur in the PREANALYTICAL phase .

Exam Trap 2: The 1-2s rule is a WARNING rule only ; it does not require run rejection.

Exam Trap 3: Centrifuge speed is calibrated semi-annually using a photo-tachometer .

Exam Trap 4: Hemolysis falsely elevates serum Potassium (K+) due to intracellular release.