Study guide

Section 1.2: Wiring Schematics and Diagrams

ASE A6 Electrical/Electronic Systems Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: General Electrical Diagnosis

Section 1.1: Ohm's Law and Circuit Principles Section 1.2: Wiring Schematics and Diagrams Section 1.3: Digital Multimeter (DMM) Operations 1.4 Oscilloscope Waveform Analysis 1.5 Circuit Faults Diagnosis

2 Chapter 2: Vehicle Networking & Communication

2.1 CAN Bus Network Diagnosis 2.2 LIN and MOST Bus Networks

3 Chapter 3: Batteries & Battery Management

Section 3.1: Battery Technologies Section 3.2: Battery Testing and Service

4 Chapter 4: Starting System Diagnosis & Repair

Section 4.1: Starter Circuit and Solenoid Diagnostics Section 4.2: Starter Control Circuit Diagnostics Section 4.3: Cranking System Symptoms

5 Chapter 5: Charging System Diagnosis & Repair

5.1 Alternator Principles and Output Testing 5.2 Voltage Regulation and Circuit Diagnostics 5.3 Smart Charging and Load Management

6 Chapter 6: Lighting Systems Diagnosis & Repair

6.1 Headlight Systems 6.2 Turn Signals and Hazard Systems 6.3 Interior and Accessory Lighting 6.4 Trailer Wiring and Brake Control

7 Chapter 7: Instrument Cluster & Driver Information

Section 7.1: Gauges and Sending Units Section 7.2: Warning Lamps and Prove-Out Section 7.3: Digital Displays and Driver Info

8 Chapter 8: Passenger Comfort & Convenience

8.1 HVAC Electrical Controls 8.2 Power Window, Lock, and Mirror Circuits 8.3 Power Seats and Memory Systems

9 Chapter 9: Safety & Security Systems

Section 9.1: Supplemental Restraint Systems (SRS) Section 9.2: Security and Keyless Entry Systems

Section 1.2: Wiring Schematics and Diagrams

Key Takeaways Explain This Topic AI

Wiring schematics represent power distribution at the top, control and load devices in the middle, and grounds at the bottom.

Relays use low current through a coil (terminals 85 and 86) to control high-current contact paths (terminals 30 and 87).

Circuit protection includes fuses, fusible links (4 gauges smaller than circuit wire), and auto-cycling or manual circuit breakers.

Smaller wire gauge numbers in AWG signify larger diameter wires, while metric wire sizes represent cross-sectional area directly.

Multi-component failures point to shared power or ground issues, while single-load faults are isolated downstream of shared splices.

Last updated: July 2026

  • Section 1.2: Wiring Schematics and Diagrams
  • Understanding Automotive Electrical Roadmaps

Wiring schematics are graphical representations of electrical circuits. They illustrate how current flows from the power distribution source, through control devices, protection devices, and loads, and finally to ground. Technicians must understand layout conventions and standard symbols to locate and isolate electrical faults efficiently.

Most manufacturers layout schematics with the power source at the top of the page and ground distribution points at the bottom. Current flows downwards. Standard circuit conventions include:

Solid Lines: Represent wires that are part of the main harness.

Dashed Lines: Represent components, connections, or internal circuits that are optional, or represent paths not fully shown on the current page.

Wire Splices (S-connection): Points where multiple wires connect together, designated with an "S" followed by a number (e.g., S205).

Connectors (C-connection): Disconnect points in the harness, designated with a "C" followed by a number (e.g., C101). Connectors are shown as male and female terminals with pin numbers or letters.

Schematic Symbols and Component Operations

To trace circuit paths, a technician must identify common schematic symbols and understand their mechanical and electrical behaviors:

Relays

Relays are electrically operated switches that control high-current loads using a low-current control signal.

Control Circuit: Terminals 85 and 86 feed a coil, creating an electromagnetic field when energized.

Switch Contact Circuit: Terminal 30 is the common feed. Terminal 87 is normally open (NO), closing when energized. Terminal 87a is normally closed (NC), opening when energized.

Protection Devices

Protection devices prevent circuit damage by opening during overcurrent conditions:

Fuses: Contain a metal element that melts at a specific amperage rating (e.g., Red=10A, Blue=15A, Yellow=20A).

Fusible Links: Short wires four gauges smaller than the circuit wire, designed to melt under high-current overloads.

Circuit Breakers: Type I (cycling) reset automatically as they cool. Type II stay open under voltage. Type III require manual reset.

Switches and Sensors

Switches direct current flow:

Poles and Throws: A Single Pole Single Throw (SPST) switch controls one circuit. A Single Pole Double Throw (SPDT) switch routes current from one input to one of two outputs. Double Pole Single Throw (DPST) and Double Pole Double Throw (DPDT) switches control multiple circuits simultaneously.

Thermistors: Temperature-sensitive resistors. Negative Temperature Coefficient (NTC) thermistors decrease resistance as temperature rises (common in coolant sensors). Positive Temperature Coefficient (PTC) thermistors increase resistance as temperature rises.

Wire Sizing and Color Identification

Wires are sized to handle the circuit's maximum current load without overheating or causing excessive voltage drop. Two standards exist:

American Wire Gauge (AWG): The smaller the gauge number, the larger the wire diameter (e.g., a 10-gauge wire is much thicker than an 18-gauge wire).

Metric Size (mm²): Represents the cross-sectional area of the conductor. Larger numbers indicate thicker wires (e.g., 0.5 mm² vs. 2.0 mm²).

Wire color coding is written in short codes:

The first letter represents the main insulation color, and the second letter represents the stripe or tracer color.

For example: "DK BLU/WHT" represents Dark Blue with a White tracer. "0.5 LG/BLK" indicates a 0.5 mm² light green wire with a black tracer.

Troubleshooting Strategies Using Schematics

Schematics help isolate faults systematically:

Shared Power: If multiple unrelated loads fail together (e.g., power mirrors and backup lights), locate a shared fuse or splice on the diagram. A short will lie downstream of the shared fuse.

Shared Ground: If nearby components act erratically (e.g., tail lights blinking when turn signals are applied), look for a loose shared ground stud. Current is back-feeding through other bulbs to find ground.

Single Load: If only one component fails, the fault lies downstream of the shared splice on its specific power or ground leg.

Real-World Technician Scenario: The Shared Fuse Short

A vehicle engine crank sensor fuse (15A) blows in the run position. Tracing the schematic, the technician finds this fuse feeds the crank sensor, purge solenoid, and oxygen sensor heater via splice S112.

Instead of inspecting the harness, they isolate components. Unplugging the oxygen sensor and purge solenoid one by one with a test light in place of the fuse reveals the short remains. Inspecting the crank sensor harness, the technician finds melted insulation from contact with the exhaust shield. Repairing the wire and rerouting the harness corrects the fault.

  • Symbol Representation Function Typical Diagnostic Point Common Failure Mode
  • Coil Symbol (Relay) Electromagnetic actuator Terminals 85 to 86 Open coil winding
  • Switch Contact (Relay) High-current pathway Terminals 30 to 87 Pitted or burnt contacts
  • Splice (Dot/Joint) Shared connection Splice block or joint Corrosion/water intrusion
  • Ground (Triangle/Fork) Return path to battery Chassis bolt or block Loose bolt or rust
  • Diagnostic Summary and Study Tips

Locate Splices First: When diagnosing multi-component failures, find the splice that connects them. The fault is upstream of the splice if all fail, and downstream if only one fails.

Trace Ground Paths: Wires route to chassis ground studs, not directly to the battery. Inspect the ground distribution blocks shown on the schematic for corrosion.