Study guide

5.1 Magnetization by Electric Current: Contact, Prods, Central Conductor

ASNT NDT Level II Certification Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 Current Exam Facts 1.2 Certification Paths: SNT-TC-1A, CP-189, and ASNT Central Certification 1.3 Level I vs Level II vs Level III Responsibilities 1.4 Application, Scheduling, Identification, and Retake Rules

2 Eligibility, Fees & Recertification

2.1 Training Hours, Experience Days, and Documentation 2.2 Vision, Practical Exams, and the Employer's Written Practice 2.3 Fees, Validity, Recertification, and 529 Funding

3 NDT Fundamentals & Method Selection

3.1 What NDT Can and Cannot Detect 3.2 Surface vs Subsurface and Method Selection Logic 3.3 Product Forms: Welds, Castings, Forgings, Wrought, In-Service Damage

4 MT Principles & Flux Fields

4.1 Magnetism, Permeability, and Flux Leakage 4.2 Flux Fields: Circular vs Longitudinal 4.3 How Discontinuities Distort Magnetic Fields

5 MT Magnetization & Demagnetization

5.1 Magnetization by Electric Current: Contact, Prods, Central Conductor 5.2 Selecting the Proper Magnetization Method: Coils, Yokes, Current Type 5.3 Demagnetization Procedures and Residual Field Limits

6 MT Equipment, Evaluation & Process Control

6.1 MT Equipment, Media, and Lighting 6.2 Types of Discontinuities Detected by MT 6.3 MT Evaluation Techniques 6.4 Quality Control of MT Equipment and Processes

7 PT Principles & Materials

7.1 PT Principles: Capillarity, Wetting, and Process Physics 7.2 Penetrant Types, Methods, and Sensitivity Classes 7.3 Developers and Process Sequence Controls

8 PT Method Selection & Process Control

8.1 Selecting the Appropriate PT Method for the Job 8.2 Surface Preparation, Dwell, Removal, and Lighting 8.3 Station Equipment, Process Control, and Safety

9 PT Indications, Evaluation & Standards

9.1 Relevant, Nonrelevant, and False Indications 9.2 Evaluating Indication Size, Shape, and Persistence 9.3 PT Procedures, ASTM/ASME Standards, and Acceptance

10 RT Principles & Exposure Technique

10.1 Radiation Physics: X-ray vs Gamma, Energy, and Attenuation 10.2 Exposure Geometry, Inverse Square Law, and Geometric Unsharpness 10.3 Radiographic Technique: kV, mA-min, Screens, and Source Selection

11 RT Image Quality, Processing & Indications

11.1 Film, Digital Detectors, Density, and Image Quality Indicators 11.2 Darkroom Facilities, Processing, and Artifact Control 11.3 Radiographic Indications, Discontinuities, and Defects

12 RT Product Discontinuities & Radiation Safety

12.1 Manufacturing Processes and Associated Discontinuities 12.2 Radiological Safety: Time, Distance, Shielding, and Dose Limits 12.3 RT Procedures, Codes, and Viewing Practice

13 UT Principles & Techniques

13.1 Sound Propagation, Modes, Velocity, and Wavelength 13.2 Transducers, Couplant, and Straight-Beam Techniques 13.3 Angle-Beam Techniques, Snell's Law, and Skip Distance

14 UT Calibration & Base Material

14.1 Calibration Blocks, DAC, TCG, and Sensitivity Setting 14.2 Evaluating Base-Material Product Forms 14.3 Evaluating Weldments

15 UT Bonds, Detection & Evaluation

15.1 Evaluating Bonded Structures 15.2 Discontinuity Detection and Characterization 15.3 General Evaluation, Sizing, and Acceptance Logic

16 VT Scope, Vision & Lighting

16.1 Purpose and Scope of VT 16.2 Elements of Vision 16.3 Elements of Lighting 16.4 Contrast and Resolution

17 VT Optics, Equipment & Discontinuities

17.1 Optics and Magnification 17.2 VT Equipment: Direct, Remote, and Measuring Tools 17.3 Visual Appearance of Discontinuities

18 VT Evaluation, Codes & Employer Topics

18.1 Evaluation and Reporting 18.2 Codes, Standards, and Specifications 18.3 Employer-Specific Topics and Written-Practice Controls

19 Specific Exam: Codes & Sectors

19.1 How the Specific Exam Differs from the General Exam 19.2 General Industry Codes and Procedure Use 19.3 Pressure Equipment Sector Codes (ASME, NBIC, API context)

20 Specific Exam: Applications & Techniques

20.1 Applications: Matching Method to Product Form and Access 20.2 Technique Selection and Essential Variables 20.3 Procedure Compliance, Reporting, and Acceptance/Rejection

21 Exam Strategy & Maintenance

21.1 Timed 50+40 Strategy and CBT Rules 21.2 Common Traps by Method 21.3 Weak-Area Review and Recertification Planning

5.1 Magnetization by Electric Current: Contact, Prods, Central Conductor

Key Takeaways Explain This Topic AI

Current through the part (headstocks or prods) or through a separate conductor (central conductor) both produce a circular field; the exam distinction is whether the part is in the electrical circuit.

ASTM E1444 sets direct circular magnetization by current through the part at a nominal 300-800 A per inch of part diameter (12-32 A/mm), normally 500 A/in or lower; the governing procedure or code table still wins.

Prods are a local through-part circular method: ASTM E1444/E709 use 90-115 A per inch of prod spacing on material 3/4 in (19 mm) thick or less and 100-125 A/in above that, with spacing held between 2 in and 8 in; setting prods down or lifting them live causes arc burn.

A central conductor magnetizes hollow parts and inside diameters without putting current into the wall, coating, or threads.

High-current contact shots can arc, burn, or ignite wet or closed-cavity parts; drain cavities and do not spark into a bath.

Last updated: August 2026

ASNT NDT Level II magnetic particle general exams administered prior to 15 December 2026 still list Magnetization by Means of Electric Current as official topic 4. The written items are not asking you to name a bench brand. They are asking whether you can put a circular magnetic field in a ferromagnetic part, whether you know which hardware puts current through the part versus through a conductor , and whether you can apply a commonly taught amperage starting point without pretending that starting point outranks the governing procedure.

Circular field from electric current

A magnetic field forms concentric circles around a current-carrying path. In magnetic particle testing (MT) that family of flux is the circular field . The classroom picture is the right-hand rule: if the thumb of the right hand points in the conventional current direction, the fingers curl in the field direction.

A circular field is strongest for discontinuities that cut across the current path — longitudinal cracks on a bar, axial seams on a shaft, and axial cracks on a tube outside or inside diameter. It is weak for discontinuities that run parallel to the current. That is why a complete written practice almost always requires a circular shot and a longitudinal shot. This section is only the current-produced circular half. Coils, cable wraps, and yokes belong to the next section.

Two current paths produce a circular field in the part:

Path Where the current flows Typical hardware Field in the part

Through the part Current enters and leaves the test object Headstocks (direct contact), prods Circular field inside the part around the current path

Through a conductor Current stays in a bar, cable, or internal conductor; the part is not in the electrical circuit Central conductor, some encircling cables Circular field induced in the surrounding wall

Current through the part magnetizes the volume the current actually occupies. Current through a separate conductor magnetizes the part from the field around that conductor. Hollow parts, coated parts, threaded bores, and burn-sensitive finishes change which path is legal. Exam stems that say "no electrical contact" or "do not damage the ID threads" are steering you off prods and often off headstocks.

Industry technique rules for these shots live in ASTM E1444/E1444M (aerospace practice), ASTM E709 (guide), and ASME Section V, Article 7 , plus the employer written practice. ASNT does not publish one universal amperage table on the Level II outline. If a stem gives a procedure table, use the table.

Direct-contact head shot

On a wet-bench horizontal unit , the part is clamped between copper-pad or lead-pad headstocks . The operator selects a circular shot and the unit drives current through the part . Shop language is a head shot or direct-contact shot .

Typical use:

  • Solid bars, shafts, pins, bolts, and other parts that fit the bench opening
  • Production lots that need a repeatable circular field plus a later coil shot in the same fixture
  • Wet fluorescent baths where the part can be flowed or immersed during the shot (continuous method)

The field is circular around the part's long axis when current is axial. Longitudinal surface cracks leak flux and collect particles. Circumferential cracks — a groove-like fatigue crack around a fillet, a heat-treat crack around a diameter — need a longitudinal field. Another head shot will not invent that field.

Pads must be clean, seated, and free of paint, heavy scale, and dried bath solids. Poor contact is how a "correct" amperage still fails to magnetize the part — or worse, arcs at the pad and pits a finished journal. Do not use the headstocks as a switch on a loosely held part. Clamp fully, then fire the shot.

Amperage starting point for through-part or encircling current

ASTM E1444/E1444M is explicit here: when magnetizing by passing current directly through the part , the nominal current shall be 300 to 800 A per inch of part diameter ( 12 to 32 A/mm ). The diameter is the greatest distance between any two points on the outside circumference of the part — not the length, and not the wall thickness.

Inside that band the standard adds working guidance you should carry into the exam:

Currents will normally be 500 A/in (20 A/mm) or lower . That is the practical starting point.

The high end, up to 800 A/in (32 A/mm) , is used to examine for inclusions or low-permeability alloys such as precipitation-hardened steels.

Below 300 A/in is allowed only when part configuration dictates and approval is obtained from the Level III and the cognizant engineering organization.

That card is for through-part (head-shot) or central-conductor current , not for prods. The governing procedure or code table still wins. Confirm with the written practice and with a field indicator or quantitative quality indicator (QQI).

Examples at the common 500 A/in working point (full 300-800 A/in band in parentheses):

  • A 2-inch-OD carbon-steel pin: about 1000 A (600-1600 A)
  • A 2.5-inch pin: about 1250 A (750-2000 A)
  • A 4-inch bar: about 2000 A (1200-3200 A)

Those are genuinely large currents, which is why a wet bench is a heavy, low-voltage, high-amperage machine. Increase or decrease only as the procedure and a QQI or pie-field indicator require. Hollow parts, non-round sections, and coated parts are not automatic diameter-card problems — the procedure will give an effective diameter or a different technique (often a central conductor).

Prod technique

Prods are handheld contact electrodes. Current still flows through the part , so the field is still circular — but it is local, between the two prods, not a full-length head shot. Prods are the usual field-portable circular method on large weldments, castings, and structures that will not fit a bench.

Common procedure limits taught in Level II courses — always confirm the written practice; these are not an ASNT-published single table:

Item Commonly taught limit Why it exists

Prod spacing Not less than 2 in and not more than 8 in (50–200 mm) Too close overheats a small patch; too far thins the field between contacts

Current, material 3/4 in (19 mm) thick or less 90–115 A per inch of prod spacing (3.5–4.5 A/mm) Provides a usable leakage field between the contacts without cooking a thin section

Current, material thicker than 3/4 in (19 mm) 100–125 A per inch of prod spacing (4.0–5.0 A/mm) Slightly more current to drive flux through the heavier section

Effective field width One fourth of the prod spacing on each side of a line through the prod centers Sets how far apart placements may be before coverage is lost

  • Contact Firm, clean metal-to-metal; prods not dragged live Prevents arc burn
  • Duty Do not park prods on one spot Prevents local overheating and temper color

Do not import the head-shot diameter card onto prods. Prod current is set per inch of prod spacing , and those numbers are far smaller than the 300–800 A per inch of diameter card. A 5-inch prod spacing on 1/2-inch plate is about 450–575 A total (90–115 A/in); the same spacing on 1-inch plate is about 500–625 A (100–125 A/in). Feeding a head-shot number such as 500 A/in of spacing into a prod shot would demand roughly 2,500 A through two small contact points — a burn-and-overheat setup, not a sensitivity gain.

The effective width of the magnetizing field is one fourth of the prod spacing on each side of the line through the prod centers. An 8-inch spacing therefore covers only about 2 inches each side of that centerline, which is exactly why placements must overlap instead of leapfrogging down a long weld.

Prod circular fields are strongest for discontinuities roughly perpendicular to the line between prods . Overlap successive placements and rotate the prod pair about 90° so you do not miss a crack that is parallel to the first current path. That two-direction rule is the same logic as a circular-plus-longitudinal bench exam, applied locally.

Prods are a poor first choice on finish-machined aerospace surfaces, thin sheet, carburized or nitrided skins that cannot tolerate a pit, and any procedure that forbids electrical contact . Those jobs move to a yoke or a coil.

Arc burn and overheating

Arc burn is a localized melt or pit from a spark at the contact. Many aerospace and pressure-equipment standards treat it as a rejectable surface condition, and the pit can start a crack. Classic causes:

  • Prods set down or lifted while current is on
  • Dirty, painted, scaled, rusty, or oily contact
  • Loose hand pressure or a prod used as a switch
  • Using the part edge as a knife switch against a pad

Overheating is a broader thermal stain, blueing, or temper color from too much current, too little spacing, or too long a shot. Both are technique failures. On the exam, "the Level II dragged live prods along the weld toe to save time" is an arc-burn stem, not a sensitivity improvement.

Central conductor

A central conductor — a copper bar, threaded rod, or internal cable — carries the current through the opening of a hollow part . The part is not in the electrical circuit. The circular field exists in the wall of the tube, ring, coupling, gear, or fitting.

Choose a central conductor when:

  • You must inspect the inside diameter as well as the outside diameter
  • Contact pads would damage threads, coatings, splines, or finished bores
  • The part is a short ring or nut that would not get a uniform through-part current between headstocks
  • You need circular magnetization of a thin wall without putting high current into that wall

The field intensity in the wall depends on the current in the conductor and the geometry. A multiple-turn internal cable multiplies ampere-turns . If the inside diameter is large and the procedure allows, offset the conductor toward one wall, inspect, then rotate and repeat so the near-wall field is adequate all around. A conductor rattling loosely in a large bore can leave a dead zone on the far wall.

Do not confuse a central conductor with a coil . A coil or cable wrap produces a longitudinal field along the part axis. A central conductor produces a circular field around the bore. A stem that says "longitudinal cracks on the ID of a coupling" wants a central conductor, not more coil turns.

Safety: arcing, burning, and wet parts

Electric-current magnetization is a high-current, low-voltage circuit. The hazards are thermal, electrical-contact, and ignition hazards, not utility-scale high voltage.

Arcing and burning. Any break in a high-current contact can pit the part and flash the operator. Clamp fully before a head shot. Never close the circuit by touching a live prod to the work.

Wet parts and explosion or fire risk. Wet fluorescent benches put the part in a petroleum or water-bath vehicle. Current plus a flammable film, or current plus a closed wet cavity, is an ignition and pressure hazard when:

  • Bath collects in a closed hollow and a head shot is fired through that cavity
  • Leads or prods arc in a solvent-rich fog
  • A wet part is prod-shot and the spark lands in pooled vehicle

Common shop controls: drain closed cavities before a contact shot, keep prod work out of pooled bath, maintain ventilation, and follow the equipment manual and the bath safety data sheet. Water-based baths reduce fire load but do not remove shock, burn, or steam-blast risk on a poor contact.

Personal protection. Insulated prod handles, dry gloves, eye protection against ultraviolet-A (fluorescent inspection) and against sparks, and no rings or watches across the headstocks.

Choosing among the three current methods

  • Need Usual current-magnetization choice
  • Production shafts and pins on a wet bench Head shot (direct contact)
  • Large weld or casting in the field, contact allowed Prods
  • Tube, ring, gear, threaded ID, burn-sensitive bore Central conductor
  • No electrical contact allowed Not this family — use a yoke or coil
  • Circumferential crack on a bar Not circular current — use a coil / cable wrap

On the general exam, "no contact permitted," "ID of a hollow fitting," or "arc-burn forbidden" steers you off prods and often off headstocks. "Longitudinal crack on a solid bar at the bench" steers you toward a head shot. "300–800 A per inch of diameter " is the through-part / central-conductor card; "90–125 A per inch of prod spacing " is the prod card. Keep those cards separate, and let the procedure win.