Study guide

The Seven SI Base Units and the 2019 Revision

ASQ Certified Calibration Technician CCT

Track your progress as you read

Finished sections get a check mark.

1 SI Definitions and Realizations

The Seven SI Base Units and the 2019 Revision Realizing SI Units in the Laboratory

2 Derived Units, Prefixes, and Constants

Derived Units and Physical Calculations SI Prefixes and Compound-Unit Conversions Physical Constants and Their Applications

3 Measurement Standards and Selection

Types and Roles of Measurement Standards Selecting Standards for an Operational Hierarchy

4 Traceability and Standard Substitution

Traceability Evidence and Impact Review Evaluating and Authorizing Standard Substitution

5 Dimensional and Mechanical Metrology

Linear Displacement and Dimensional Instruments Geometry, Thermal Expansion, and Mass Force, Torque, Pressure, Density, and Viscosity

6 Temperature, Humidity, Volume, and Flow

Temperature Sensors and Thermometer Corrections Humidity, Volume, and Flow

7 Electrical, Optical, and Time Measurements

Voltage, Current, Resistance, and AC Measurement Time, Frequency, Light, Power, and Energy

8 Measurement Methods

Direct, Indirect, and Ratio Methods Transfer, Differential, and UUT Substitution Methods

9 Instrument Characteristics and Measurement Data

Sensitivity, Variability, and Precision Bias, Linearity, Stability, and Hysteresis Data Formats, Readability, and Suitability Resolution, Confidentiality, and Data Integrity

10 Specifications and Error Sources

Interpreting IM&TE Specification Terms Specification Calculations and Operating Qualifiers Instrument, Operator, and Circuit Errors Environmental, Geometric, and Interference Errors

11 Measurement Assurance

Check Standards and Statistical Process Control Proficiency Comparisons and Gage R&R

12 Procedures and Governing Requirements

Procedure Structure and Published Practice Sources Method Development, Deviations, and Handling Regulations, Contracts, and Requirement Precedence

13 Instrument Adjustment and Standardization

Calibration, Zero, and Span Adjustment Linearization, Nulling, and Digital Adjustment

14 Calibration Environment

Temperature and Humidity Control ESD, Dust, Vibration, and Pressure

15 Operations, Roles, and Scheduling

Receiving, As-Found Testing, and Calibration Flow Asset Identification, Tracking, and Release Laboratory Roles and Initial Scheduling Interval Review, Overdue Control, and Workloads

16 Method and Software Validation

Method Verification and Validation Studies Software, Firmware, and Spreadsheet Validation

17 Records and Formal Reporting

Controlled Records and Calibration Certificates Status Labels and Out-of-Tolerance Reporting

18 Uncertainty Concepts and Decision Risk

Error, Uncertainty, and Measurand Definition TAR, TUR, Tolerance Consumption, and Capability Conformity Decisions and False-Accept Risk Guard Bands and Conformity Reporting

19 Uncertainty Models and Budgets

Measurement Models and Uncertainty Contributions Distribution Selection and Budget Assembly

20 Type A and Type B Evaluation

Type A Statistics and Repeatability Outlier Review and Worked Type A Analysis Type B Distribution Models

21 Uncertainty Reporting and Applied Mathematics

Propagation, Covariance, and Effective Degrees of Freedom Coverage Factors and Expanded-Uncertainty Reporting Notation, Unit Conversions, Ratios, and Decibels Rounding, Algebra, Graphs, and Angular Conversions

22 Quality Systems and Tools

Quality-System Components, Planning, and Improvement The Seven Basic Quality Tools

23 Audits and Corrective Action

Audit Types, Planning, and Nonconformance Control Impact Assessment, Root Cause, and Effectiveness

24 Safety, Standards, and Professional Conduct

Electrical, Pressure, Chemical, and Laboratory Hazards PPE, Safety Data Sheets, 6S, and Safe Restoration Quality Standards, GUM, and VIM Accreditation Scope and Professional Ethics

The Seven SI Base Units and the 2019 Revision

Key Takeaways Explain This Topic AI

The SI has seven base units: second, metre, kilogram, ampere, kelvin, mole, and candela.

The revised definitions took effect on May 20, 2019, after adoption in 2018.

Defining constants have exact values, but physical realizations and transferred results have uncertainty.

Last updated: October 2026

Calibration establishes, under specified conditions, a relationship between standard quantity values and instrument indications, including their uncertainties, and then permits a measurement result to be obtained from an indication. Calibration and adjustment are different operations. The International System of Units (SI) supplies a common reference for measurements that can be expressed in SI units.

The CGPM adopted the revised SI in November 2018, with implementation on May 20, 2019. Fixing seven defining constants ended the international prototype kilogram’s role as the definition of mass. Physical weights, cells, resistors, and other artifacts remain essential working and transfer standards; their values and stability still require calibration.

The Seven Base SI Units

The SI is structured around seven mutually independent base units, each corresponding to a distinct physical dimension. All other physical quantities are mathematically derived from these seven foundational building blocks.

Unit Name Unit Symbol Physical Dimension / Quantity Defining Constant Exact Fixed Numerical Value of Defining Constant

second s \text{s} s Time ( T T T ) Hyperfine transition frequency of cesium-133 ( Δ ν Cs \Delta\nu_{\text{Cs}} Δ ν Cs ​ ) 9 , 192 , 631 , 770 Hz 9,192,631,770\text{ Hz} 9 , 192 , 631 , 770 Hz ( 9 , 192 , 631 , 770 s − 1 9,192,631,770\text{ s}^{-1} 9 , 192 , 631 , 770 s − 1 )

meter m \text{m} m Length ( L L L ) Speed of light in vacuum ( c c c ) 299 , 792 , 458 m/s 299,792,458\text{ m/s} 299 , 792 , 458 m/s

kilogram kg \text{kg} kg Mass ( M M M ) Planck constant ( h h h ) 6.62607015 × 10 − 34 J ⋅ s 6.62607015 \times 10^{-34}\text{ J}\cdot\text{s} 6.62607015 × 1 0 − 34 J ⋅ s ( kg ⋅ m 2 ⋅ s − 1 \text{kg}\cdot\text{m}^2\cdot\text{s}^{-1} kg ⋅ m 2 ⋅ s − 1 )

ampere A \text{A} A Electric Current ( I I I ) Elementary charge ( e e e ) 1.602176634 × 10 − 19 C 1.602176634 \times 10^{-19}\text{ C} 1.602176634 × 1 0 − 19 C ( A ⋅ s \text{A}\cdot\text{s} A ⋅ s )

kelvin K \text{K} K Thermodynamic Temperature ( Θ \Theta Θ ) Boltzmann constant ( k B k_{\text{B}} k B ​ ) 1.380649 × 10 − 23 J/K 1.380649 \times 10^{-23}\text{ J/K} 1.380649 × 1 0 − 23 J/K ( kg ⋅ m 2 ⋅ s − 2 ⋅ K − 1 \text{kg}\cdot\text{m}^2\cdot\text{s}^{-2}\cdot\text{K}^{-1} kg ⋅ m 2 ⋅ s − 2 ⋅ K − 1 )

mole mol \text{mol} mol Amount of Substance ( N N N ) Avogadro constant ( N A N_{\text{A}} N A ​ ) 6.02214076 × 10 23 mol − 1 6.02214076 \times 10^{23}\text{ mol}^{-1} 6.02214076 × 1 0 23 mol − 1

candela cd \text{cd} cd Luminous Intensity ( J J J ) Luminous efficacy of 540 × 10 12 Hz 540 \times 10^{12}\text{ Hz} 540 × 1 0 12 Hz radiation ( K cd K_{\text{cd}} K cd ​ ) 683 lm/W 683\text{ lm/W} 683 lm/W ( cd ⋅ sr ⋅ kg − 1 ⋅ m − 2 ⋅ s 3 \text{cd}\cdot\text{sr}\cdot\text{kg}^{-1}\cdot\text{m}^{-2}\cdot\text{s}^3 cd ⋅ sr ⋅ kg − 1 ⋅ m − 2 ⋅ s 3 )

The Historical Artifact Dilemma and the Need for Redefinition

To understand why the 2019 redefinitions were critical, calibration technicians must examine the metrological vulnerability of artifact-based standards.

The International Prototype of the Kilogram (IPK)

From 1889 until May 19, 2019, the kilogram was uniquely defined as the exact mass of a single physical object: the International Prototype of the Kilogram (IPK) , affectionately known as "Le Grand K" . The IPK is a right-circular cylinder (height equal to diameter ≈ 39.17 mm \approx 39.17\text{ mm} ≈ 39.17 mm ) composed of 90 % 90\% 90% platinum and 10 % 10\% 10% iridium by mass, manufactured in London by Johnson Matthey and stored under three nested glass bell jars in an environmentally controlled vault at the International Bureau of Weights and Measures (BIPM) in Sèvres, France.

Official copies were distributed to national metrology institutes and compared periodically with the IPK. Differences of tens of micrograms among prototypes exposed the limitations of defining a unit using one artifact: comparisons revealed relative change but could not independently identify a change of the defining prototype itself. Δ m = m copies − m IPK ≈ + 50 μ g over 100 years \Delta m = m_{\text{copies}} - m_{\text{IPK}} \approx +50\ \mu\text{g}\text{ over } 100\text{ years} Δ m = m copies ​ − m IPK ​ ≈ + 50 μ g over 100 years

The mass of the official national copies had systematically drifted relative to the IPK by approximately 50 μ g 50\ \mu\text{g} 50 μ g (parts in 10 8 10^8 1 0 8 ). Because the IPK was defined as exactly one kilogram by international treaty, metrologists could not establish with absolute certainty whether the national copies were gaining mass (via surface absorption of environmental hydrocarbons and atmospheric mercury) or whether the IPK was losing mass (via microscopic surface wear during cleaning protocols and outgassing). Under an artifact standard:

A change of the defining artifact would change the physical reference for the unit; it would not physically change other objects.

An artifact standard cannot be independently realized by NMIs; national standards had to be periodically hand-carried across international borders back to France for recalibration.

Loss of the IPK would have required an international recovery of the reference using comparison evidence and surviving copies. It would not erase all existing calibration records or automatically invalidate every past mass result.

Historical Transitions of Other Base Units

The kilogram was simply the last artifact to fall. Metrology had already transitioned several base units away from artifacts:

The Meter Bar (1889–1960): Replaced a platinum-iridium meter bar with a wavelength of light from a krypton-86 discharge lamp ( 1 , 650 , 763.73 1,650,763.73 1 , 650 , 763.73 wavelengths in vacuum).

The Speed of Light Definition of the Meter (1983): In 1983, the 17th CGPM redefined the meter as the path length traveled by light in a vacuum in 1 / 299 , 792 , 458 1 / 299,792,458 1/299 , 792 , 458 of a second, fixing c = 299 , 792 , 458 m/s c = 299,792,458\text{ m/s} c = 299 , 792 , 458 m/s .

The Ampere's Classical Definition (1948–2019): Formerly defined as that constant current which, if maintained in two straight parallel conductors of infinite length, of negligible circular cross-section, and placed 1 meter apart in vacuum, would produce between these conductors a force equal to 2 × 10 − 7 newtons per meter 2 \times 10^{-7}\text{ newtons per meter} 2 × 1 0 − 7 newtons per meter of length. This definition was an unachievable theoretical thought experiment that could never be realized directly in a laboratory without substantial systematic uncertainty.

The Kelvin's Triple Point of Water Definition (1954–2019): Formerly defined as the fraction 1 / 273.16 1 / 273.16 1/273.16 of the thermodynamic temperature of the triple point of water. This tied temperature to an isotopic blend called Vienna Standard Mean Ocean Water (VSMOW). Minute isotopic variations in hydrogen and oxygen ratios ( 2 H / 1 H ^2\text{H}/^1\text{H} 2 H / 1 H , 17 O / 16 O ^{17}\text{O}/^{16}\text{O} 17 O / 16 O , 18 O / 16 O ^{18}\text{O}/^{16}\text{O} 18 O / 16 O ) in water samples created irreproducible temperature shifts on the order of tens of microkelvins.