Study guide
14.2 Antenna Analysers, Vector Network Analysers, and Smith Charts
ACMA Amateur Radio Advanced Recognition Certificate - Theory Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: DC Theory, Circuit Laws & Passive Components
1.1 DC Circuit Analysis, Ohm's Law, and Kirchhoff's Laws 1.2 AC Fundamentals, Sine Waves, Peak, RMS, and Phase Relationships 1.3 Inductance, Capacitance, Reactance, and Time Constants
2 Chapter 2: Impedance, Resonance & Passive Filters
2.1 Complex Impedance, Phasors, and AC Circuit Analysis 2.2 Series and Parallel LC Resonance and Q Factor 2.3 Passive Filters, Cutoff Frequency, and Attenuator Pads
3 Chapter 3: Semiconductor Devices & Power Supplies
3.1 Semiconductor Diodes, Zener Regulators, and Rectifier Circuits 3.2 Bipolar Junction Transistors, FETs, and Operational Amplifiers 3.3 Thermionic Valves (Vacuum Tubes) and High-Power Linear Amplifiers 3.4 DC Power Supplies, Filter Networks, and Voltage Regulators
4 Chapter 4: Oscillators & Frequency Synthesis
4.1 RF Oscillators, LC Tank Topologies, and Frequency Stability 4.2 Phase-Locked Loops (PLLs) and Frequency Synthesisers 4.3 Direct Digital Synthesis (DDS), SDR Architectures, and Digital Filter Topologies
5 Chapter 5: RF Amplifiers & Linearity
5.1 Classes of Amplification, Conduction Angles, and Operating Efficiency 5.2 RF Power Amplifiers, Push-Pull Topologies, and Output Matching 5.3 Amplifier Stability, Neutralisation, and Intermodulation Distortion
6 Chapter 6: Modulation & Demodulation
6.1 Amplitude Modulation, Double Sideband, and Single Sideband (SSB) 6.2 Frequency Modulation, Phase Modulation, and FM Detectors 6.3 Digital Modulation Modes, Spectral Efficiency, and Weak-Signal Protocols
7 Chapter 7: Transmitters, Mixers & Receivers
7.1 RF Mixers, Frequency Translation, and Intermodulation 7.2 Transmitter Architectures, CW Keying, and Output Filtering 7.3 Superheterodyne Receiver Design, IF Selection, and Image Rejection 7.4 Receiver Performance Specifications, Dynamic Range, and Selectivity
8 Chapter 8: Transmission Lines & Waveguides
8.1 Transmission Line Characteristics, Impedance, and Velocity Factor 8.2 Standing Waves, Reflection Coefficient, SWR, and Return Loss 8.3 Resonant Line Sections, Quarter-Wave Transformers, and Stubs
9 Chapter 9: Impedance Matching & Baluns
9.1 Lumped-Element Matching Networks and Antenna Tuning Units 9.2 Baluns, Ununs, and Common-Mode Current Choking 9.3 Feedline Losses, High-SWR Stress, and Coaxial Installation Practice
10 Chapter 10: Practical Antennas & Arrays
10.1 Resonant Dipoles, Inverted-Vs, and Multiband Wire Antennas 10.2 Quarter-Wave Verticals, Ground Systems, and Radiation Efficiency 10.3 Parasitic Arrays, Yagi-Uda Antennas, and Quad Arrays 10.4 Antenna Gain, Aperture Antennas & Horns, ERP/EIRP, Radiation Patterns
11 Chapter 11: Radio Wave Propagation & Ionospheric Mechanics
11.1 Electromagnetic Wave Fundamentals, Polarisation, and Ground Waves 11.2 The Ionosphere, Solar Radiation, and Solar Cycles 11.3 Critical Frequency, Maximum Usable Frequency, and HF Propagation Paths
12 Chapter 12: VHF/UHF Propagation & Space Communications
12.1 Line-of-Sight, Tropospheric Ducting, and Diffraction 12.2 Sporadic-E, Auroral Scatter, and Trans-Equatorial Propagation 12.3 Amateur Satellites, Doppler Shift, and Earth-Moon-Earth (EME)
13 Chapter 13: Test Equipment & RF Measurements
13.1 Decibels, Power Ratios, and Cascaded Stage Calculations 13.2 RF Power Meters, Directional Couplers, and Dummy Loads 13.3 Multirange Meters, Waveform Diagnostics, Oscilloscopes, and Frequency Counters
14 Chapter 14: Advanced RF Analysis & Diagnostics
14.1 Spectrum Analyser Architecture, Operation, and Spectral Purity 14.2 Antenna Analysers, Vector Network Analysers, and Smith Charts 14.3 Calibrated Signal Generators, Grid Dip Meters, and Component Testing
15 Chapter 15: Electromagnetic Compatibility & Interference
15.1 Sources of Interference, Coupling Mechanisms, and Audio Rectification 15.2 Receiver Susceptibility, Desensitisation, and Front-End Intermodulation 15.3 Practical RFI Suppression, Filter Design, and Bonding Techniques
16 Chapter 16: Electrical, RF & Station Safety
16.1 Biological Effects of RF Energy and ARPANSA Exposure Standards 16.2 Safe Separation Distances, Power Density, and Duty Cycles 16.3 Station Electrical Safety, Battery Hazards, and Safe Headphone Use 16.4 Mast and Tower Construction, Power Line Clearance, and Lightning Protection
14.2 Antenna Analysers, Vector Network Analysers, and Smith Charts
Key Takeaways Explain This Topic AI
Scalar antenna analysers use amplitude detectors. ∣ Γ ∣ |\Gamma| ∣Γ∣ determines VSWR; extra bridge samples may also provide R R R , ∣ X ∣ |X| ∣ X ∣ and ∣ Z ∣ |Z| ∣ Z ∣ . Without signed phase information, inductive + j X +jX + j X and capacitive − j X -jX − j X can remain indistinguishable.
Vector Network Analysers (VNAs) utilize dual-port quadrature (I/Q) receivers to measure both the magnitude ( ∣ Γ ∣ |\Gamma| ∣Γ∣ ) and phase angle ( θ \theta θ ) of reflection ( S 11 S_{11} S 11 ) and transmission ( S 21 S_{21} S 21 ), fully resolving complex impedance ( R ± j X R \pm jX R ± j X ).
The Smith Chart is a conformal polar mapping of the complex reflection coefficient ( Γ \Gamma Γ ), where the prime center represents a perfect match ( r = 1.0 , x = 0 ⟹ 50 + j 0 Ω r = 1.0, x = 0 \implies 50 + j0\ \Omega r = 1.0 , x = 0 ⟹ 50 + j 0 Ω ), the upper hemisphere represents inductive reactance ( + j x +jx + j x ), and the lower hemisphere represents capacitive reactance ( − j x -jx − j x ).
Circles of constant VSWR are concentric circles centered on the prime center ( r = 1.0 r = 1.0 r = 1.0 ), with VSWR read directly where the circle intersects the right-hand equatorial real axis.
Calibration establishes the measurement reference plane where the standards are connected. Calibrate at the far end of a test cable to measure there, or use valid cable de-embedding. A delay-only correction removes phase delay; it does not also remove cable loss or mismatch.
Last updated: November 2026
14.2 Antenna Analysers, Vector Network Analysers, and Smith Charts
Optimising an antenna system requires understanding the complex impedance presented at its feedpoint. While a simple inline SWR meter provides a basic indication of forward versus reflected power under transmit conditions, it offers zero insight into whether an antenna is electrically too long or too short, nor can it identify reactive components required for matching networks. Modern radio amateurs utilize scalar antenna analysers and Vector Network Analysers (VNAs) to inspect impedance across wide frequency bands, mapping complex impedance onto the Smith Chart and locating transmission-line discontinuities from their reflection delay.
Operating Principles of RF Impedance Analysers Scalar Bridge Vector Measurement
- Source --> Bridge --> DUT Source --> DUT --> Port2 receiver
- | | |
- Multiple amplitude samples Reference Reflected
- | channel channel
- Scalar processing \ /
- | Complex receiver ratios
- VSWR; R, |X| or |Z| |
- when supported S11 and S21, magnitude/phase
Scalar amplitude data can leave +X/-X ambiguous. The vector system needs
incident, reflected and transmitted channels for forward two-port tests.
1. Scalar Antenna Analysers
A scalar antenna analyser integrates a low-power variable RF source (such as a Direct Digital Synthesis, DDS, generator) with an internal Wheatstone bridge or directional coupler and diode detectors. The instrument excites the unknown load with a known RF voltage and samples the reflected voltage wave:
The detector measures the magnitude of the voltage reflection coefficient ( ∣ Γ ∣ |\Gamma| ∣Γ∣ ):
∣ Γ ∣ = ∣ V reflected ∣ ∣ V forward ∣ |\Gamma| = \frac{|V_{\text{reflected}}|}{|V_{\text{forward}}|} ∣Γ∣ = ∣ V forward ∣ ∣ V reflected ∣
From ∣ Γ ∣ |\Gamma| ∣Γ∣ , the instrument computes Voltage Standing Wave Ratio (VSWR):
VSWR = 1 + ∣ Γ ∣ 1 − ∣ Γ ∣ \text{VSWR} = \frac{1 + |\Gamma|}{1 - |\Gamma|} VSWR = 1 − ∣Γ∣ 1 + ∣Γ∣
Additional bridge-voltage measurements can provide R R R , ∣ X ∣ |X| ∣ X ∣ and ∣ Z ∣ = R 2 + X 2 |Z|=\sqrt{R^2+X^2} ∣ Z ∣ = R 2 + X 2 in instruments equipped for them. These do not follow from ∣ Γ ∣ |\Gamma| ∣Γ∣ alone, which specifies only a constant-VSWR circle.
The Critical Blindness of Scalar Analysers:
Without a phase-sensitive reference, the scalar bridge does not directly determine the sign of the voltage/current phase angle. Even where several amplitude samples allow R R R and ∣ X ∣ |X| ∣ X ∣ to be calculated, the two reactance signs remain ambiguous:
A scalar analyser cannot determine whether reactance is inductive ( + j X +jX + j X ) or capacitive ( − j X -jX − j X ).
If an antenna presents 50 + j 25 Ω 50 + j25\ \Omega 50 + j 25 Ω (electrically too long) or 50 − j 25 Ω 50 - j25\ \Omega 50 − j 25 Ω (electrically too short), a scalar analyser reports an identical VSWR of 1.6 : 1 1.6:1 1.6 : 1 and ∣ Z ∣ = 55.9 Ω |Z| = 55.9\ \Omega ∣ Z ∣ = 55.9 Ω .
The sign can often be inferred by sweeping frequency around a simple antenna resonance. A small known change in antenna length and its effect on the reading is another test.
2. Vector Network Analysers (VNAs)
A Vector Network Analyser (VNA) —exemplified in amateur radio by the compact, dual-port NanoVNA and high-end laboratory instruments—measures both magnitude and phase of reflected and transmitted waves across a designated frequency sweep. A VNA treats the device under test (DUT) as an electrical network described by Scattering Parameters (S-parameters) : Two-Port Network (S-Parameters)
- Port 1 (Input) Port 2 (Output)
- Incident a_1 ---> +-----------------+ ---> Transmitted b_2
- | Device Under |
- Reflected b_1 <--- | Test (DUT) | <--- Incident a_2
- +-----------------+
- S_11 = b_1 / a_1, S_21 = b_2 / a_1, both with a_2 = 0
- (Port 2 terminated in the reference impedance.)
S 11 S_{11} S 11 : With Port 2 matched to Z 0 Z_0 Z 0 ( a 2 = 0 a_2=0 a 2 = 0 ), b 1 / a 1 b_1/a_1 b 1 / a 1 is the input reflection coefficient. For a one-port antenna, this gives feedpoint impedance, return loss and VSWR at the calibrated reference plane.
S 21 S_{21} S 21 : Under the same matched-output condition, b 2 / a 1 b_2/a_1 b 2 / a 1 is the forward transmission coefficient, used for filter response, insertion loss, amplifier gain and cable attenuation.
Quadrature I/Q Down-Conversion Architecture
Inside the VNA, a reference channel samples the incident signal, while measurement channels sample reflected ( S 11 S_{11} S 11 ) and transmitted ( S 21 S_{21} S 21 ) signals. Each channel feeds an I/Q (In-phase and Quadrature) mixer driven by a local oscillator. By multiplying the incoming RF by cos ( ω t ) \cos(\omega t) cos ( ω t ) and sin ( ω t ) \sin(\omega t) sin ( ω t ) , the VNA resolves the response into real ( I I I ) and imaginary ( Q Q Q ) components:
Γ = Γ r + j Γ i = ∣ Γ ∣ e j θ = ∣ Γ ∣ cos ( θ ) + j ∣ Γ ∣ sin ( θ ) \Gamma = \Gamma_r + j\Gamma_i = |\Gamma| e^{j\theta} = |\Gamma| \cos(\theta) + j |\Gamma| \sin(\theta) Γ = Γ r + j Γ i = ∣Γ∣ e j θ = ∣Γ∣ cos ( θ ) + j ∣Γ∣ sin ( θ )
Resolving Complex Impedance ( R ± j X R \pm jX R ± j X )
Knowing both magnitude ∣ Γ ∣ |\Gamma| ∣Γ∣ and phase θ \theta θ , the VNA computes complex load impedance directly via the bilinear conformal transformation:
Z L = Z 0 ⋅ 1 + Γ 1 − Γ = R + j X Z_L = Z_0 \cdot \frac{1 + \Gamma}{1 - \Gamma} = R + jX Z L = Z 0 ⋅ 1 − Γ 1 + Γ = R + j X
where Z 0 Z_0 Z 0 is the system characteristic impedance ( 50.0 Ω 50.0\ \Omega 50.0 Ω ).
If θ > 0 ∘ \theta > 0^\circ θ > 0 ∘ , the reflected wave leads the incident reference, revealing inductive reactance ( + j X +jX + j X ) (voltage leads current; the antenna is electrically too long or contains series inductance).
If θ < 0 ∘ \theta < 0^\circ θ < 0 ∘ , the reflected wave lags the incident reference, revealing capacitive reactance ( − j X -jX − j X ) (current leads voltage; the antenna is electrically too short or contains series capacitance).
The Smith Chart in Amateur Radio Practice
The Smith Chart , introduced by Philip H. Smith in 1939, is drawn in the complex reflection-coefficient plane. A grid labelled in normalized impedance is overlaid using Γ = ( z − 1 ) / ( z + 1 ) \Gamma=(z-1)/(z+1) Γ = ( z − 1 ) / ( z + 1 ) . It therefore lets the same point show both reflection coefficient and load impedance. The Smith Chart
- Inductive Reactance (+jx)
- Upper Hemisphere
- / | \
- / | \
- / r=1.0 \
- / | \
- Short Circuit +---------O---------+ Open Circuit
- r = 0, x = 0 | Prime | Z tends to infinity
- (Γ = -1.0) | Center | (Γ = +1.0)
- \ (50 + j0 Ω) /
- \ | /
- \ | /
- \ | /
- Capacitive Reactance (-jx)
- Lower Hemisphere
- 1. Conformal Mapping and Normalized Impedance
The boundary of the Smith Chart corresponds to the unit circle of the reflection coefficient ( ∣ Γ ∣ = 1.0 |\Gamma| = 1.0 ∣Γ∣ = 1.0 ), encompassing all passive impedances with non-negative resistance ( R ≥ 0 R \ge 0 R ≥ 0 ). To make the chart universal across any characteristic impedance, impedances are normalized by dividing by Z 0 Z_0 Z 0 ( 50 Ω 50\ \Omega 50 Ω ):
z = Z L Z 0 = R + j X Z 0 = r + j x z = \frac{Z_L}{Z_0} = \frac{R + jX}{Z_0} = r + jx z = Z 0 Z L = Z 0 R + j X = r + j x
Example: A physical impedance of Z L = 25 + j 50 Ω Z_L = 25 + j50\ \Omega Z L = 25 + j 50 Ω normalizes in a 50 Ω 50\ \Omega 50 Ω system to:
- z = 25 + j 50 50 = 0.5 + j 1.0 z = \frac{25 + j50}{50} = 0.5 + j1.0 z = 50 25 + j 50 = 0.5 + j 1.0
- 2. Geometry of the Chart
The Smith Chart consists of orthogonal circles and arcs:
The Horizontal Equator (Real / Resistance Axis): The horizontal diameter represents purely resistive impedance ( x = 0 x = 0 x = 0 , zero reactance).
Far Left Point ( 0.0 0.0 0.0 ): Zero resistance and zero reactance ( z = 0 + j 0 Ω z = 0 + j0\ \Omega z = 0 + j 0 Ω ). Represents an ideal Short Circuit ( Γ = − 1.0 , θ = 180 ∘ \Gamma = -1.0, \theta = 180^\circ Γ = − 1.0 , θ = 18 0 ∘ ).
Far Right Point ( ∞ \infty ∞ ): Infinite impedance ( z = ∞ z = \infty z = ∞ ). Represents an ideal Open Circuit ( Γ = + 1.0 , θ = 0 ∘ \Gamma = +1.0, \theta = 0^\circ Γ = + 1.0 , θ = 0 ∘ ).
Prime Center Point ( 1.0 1.0 1.0 ): Normalized impedance z = 1.0 + j 0 z = 1.0 + j0 z = 1.0 + j 0 , representing a perfect 50 + j 0 Ω 50 + j0\ \Omega 50 + j 0 Ω match . At this point, Γ = 0 \Gamma = 0 Γ = 0 and VSWR = 1.0 : 1 \text{VSWR} = 1.0:1 VSWR = 1.0 : 1 .
Circles of Constant Resistance ( r r r circles): All constant resistance circles are centered on the horizontal axis and are mutually tangent to each other at the open-circuit point on the far right ( r = ∞ r = \infty r = ∞ ). Every point on the r = 1.0 r = 1.0 r = 1.0 circle has a real resistive component of exactly 50 Ω 50\ \Omega 50 Ω (e.g., 50 + j 25 Ω 50 + j25\ \Omega 50 + j 25 Ω , 50 − j 50 Ω 50 - j50\ \Omega 50 − j 50 Ω ).
Arcs of Constant Reactance ( x x x arcs): Curves of constant reactance branch outward from the open-circuit point and cross the resistance circles perpendicularly:
Upper Hemisphere: Represents Inductive Reactance ( + j x +jx + j x ) . Any impedance trajectory lying in the upper half of the chart has positive reactance ( + j X L +jX_L + j X L ).
Lower Hemisphere: Represents Capacitive Reactance ( − j x -jx − j x ) . Any trajectory lying in the lower half has negative reactance ( − j X C -jX_C − j X C ).
Circles of Constant VSWR: Because reflection coefficient magnitude ( ∣ Γ ∣ |\Gamma| ∣Γ∣ ) is directly related to VSWR, any contour of constant VSWR forms a perfect circle centered on the prime center ( 1.0 1.0 1.0 ) .
To read the VSWR of any point on the chart, draw a circle centered at the prime center through that point. The value where the right-hand edge of this circle crosses the horizontal resistance axis equals the VSWR directly!
A point at z = 2.0 + j 0 z = 2.0 + j0 z = 2.0 + j 0 lies on the VSWR = 2.0 : 1 \text{VSWR} = 2.0:1 VSWR = 2.0 : 1 circle. A point at z = 0.5 + j 0 z = 0.5 + j0 z = 0.5 + j 0 also lies on the VSWR = 2.0 : 1 \text{VSWR} = 2.0:1 VSWR = 2.0 : 1 circle ( 50 / 25 = 2.0 50 / 25 = 2.0 50/25 = 2.0 ).
3. Transmission Line Behavior on the Smith Chart
When traversing a transmission line, impedance transforms continuously:
Direction of Travel: Moving along a line toward the transmitter/generator corresponds to moving clockwise around the Smith Chart ("Toward Generator"). Moving toward the load corresponds to moving counter-clockwise ("Toward Load").
Electrical Length: One complete 360 ∘ 360^\circ 36 0 ∘ rotation around the Smith Chart corresponds to an electrical distance of half a wavelength ( λ / 2 \lambda / 2 λ /2 ) .
Quarter-Wave Inversion: A rotation of 180 ∘ 180^\circ 18 0 ∘ corresponds to a quarter-wavelength ( λ / 4 \lambda / 4 λ /4 ) , inverting low impedance to high impedance (transforming a short circuit into an open circuit).
Transmission Line Loss: In a lossless line, the impedance trajectory follows a perfect circle of constant radius ( ∣ Γ ∣ = constant |\Gamma| = \text{constant} ∣Γ∣ = constant ). In a real, lossy coaxial cable, attenuation absorbs power in both directions, causing the trajectory to spiral inward toward the prime center ( 50 Ω 50\ \Omega 50 Ω ) . This illustrates why a long, lossy coaxial line makes a severely mismatched antenna appear to have a "good" SWR at the shack end!
- Calibration and Transmission Line Diagnostics
- 1. SOLT Calibration and Shifting the Reference Plane
A VNA cannot deliver accurate measurements without systematic calibration. The internal directional couplers, detector diodes, internal cables, and external test leads possess stray inductance, shunt capacitance, and phase delay. Calibration measures these systematic errors and mathematically subtracts (de-embeds) them from measurements. SOLT Calibration Architecture
- [ VNA Port 1 ] =====( Test Cable / Jumper )=====[ Reference Plane ]---->[ Device Under Test ]
- |
Calibration Standards:
- SHORT (Zero Ω, Phase = 180°)
- OPEN (Infinite Ω, Phase = 0°)
- LOAD (Precision 50.0 Ω, Γ = 0)
- THRU (Direct connection Port 1 to 2)
The standard calibration protocol is SOLT :
SHORT: A precision short circuit presenting 0 Ω 0\ \Omega 0 Ω (reflection coefficient Γ = 1.0 ∠ 180 ∘ \Gamma = 1.0 \angle 180^\circ Γ = 1.0∠18 0 ∘ ).
OPEN: A precision open circuit presenting infinite impedance ( Γ = 1.0 ∠ 0 ∘ \Gamma = 1.0 \angle 0^\circ Γ = 1.0∠ 0 ∘ ).
LOAD: A precision non-inductive 50.0 Ω 50.0\ \Omega 50.0 Ω termination ( Γ = 0.0 \Gamma = 0.0 Γ = 0.0 , absorbs all incident power).
THRU: A direct zero-length connection between Port 1 and Port 2 (for two-port transmission measurements).
Important
The Reference Plane Rule: Standards establish the reference plane where they are connected. Calibration at the front-panel connector followed by a 15 -meter 15\text{-meter} 15 -meter feedline measures the cable-plus-antenna input impedance. For the feedpoint impedance:
Calibrate at the far end of the cable, using the appropriate reflection standards (and a through for a two-port calibration).
Alternatively, de-embed a known cable model. Electrical Delay and basic phase-only Port Extension remove delay, not attenuation or mismatch; use loss compensation only where the instrument supports it and the cable model is valid.
2. Time Domain Reflectometry (TDR) via IFFT
A VNA measures complex S 11 S_{11} S 11 over frequency and can transform those data into a time-domain response. Lowpass impulse/step modes require suitable harmonic frequency spacing and a DC estimate; a bandpass impulse mode can use a band-limited sweep. The display mode matters when interpreting a fault. Ideal Lowpass Step Responses: Alternative Cable Ends
- Gamma
- +1 | +---------------- Open
- | |
- 0 +------------------------+----------------------> Delay
- | |
- 1 | +---------------- Short
- round-trip delay
A signed lowpass-step response distinguishes an impedance increase from a decrease. A bandpass magnitude peak locates a discontinuity but does not by itself give its reactive sign. Time/distance resolution depends on frequency span and windowing; display zoom cannot create millimetre measurement resolution.
By knowing the coaxial cable's Velocity Factor ( v f v_f v f ) , the time delay ( t t t ) of any reflected pulse converts directly into physical distance ( d d d ):
d = v f ⋅ c ⋅ t 2 d = \frac{v_f \cdot c \cdot t}{2} d = 2 v f ⋅ c ⋅ t
where c c c is the speed of light ( 3.00 × 10 8 m/s 3.00 \times 10^8\text{ m/s} 3.00 × 1 0 8 m/s ) and the factor of 2 accounts for the two-way round trip.
Diagnostic Interpretation (Lowpass Step Mode):
Positive change: A higher impedance; an ideal lossless open termination has Γ = + 1 \Gamma=+1 Γ = + 1 .
Negative change: A lower impedance; an ideal short termination has Γ = − 1 \Gamma=-1 Γ = − 1 .
Distributed lower-impedance region: This can indicate a dielectric or geometry change. Water ingress can increase effective permittivity and lower impedance, but the trace alone does not uniquely identify the cause. Cable loss and calibration affect the returned amplitude.
- Step-by-Step Worked Calculations
- Worked Example 1: Reflection Coefficient and VSWR Calculation
A VNA measures the complex feedpoint impedance of an off-center fed dipole at 14.15 MHz 14.15\text{ MHz} 14.15 MHz as Z L = 30 − j 40 Ω Z_L = 30 - j40\ \Omega Z L = 30 − j 40 Ω . In a 50.0 Ω 50.0\ \Omega 50.0 Ω system, calculate:
The complex reflection coefficient ( Γ \Gamma Γ ).
The reflection coefficient magnitude ( ∣ Γ ∣ |\Gamma| ∣Γ∣ ).
The resulting VSWR.
Calculation:
Compute Γ \Gamma Γ using the reflection coefficient formula:
Γ = Z L − Z 0 Z L + Z 0 = ( 30 − j 40 ) − 50 ( 30 − j 40 ) + 50 = − 20 − j 40 80 − j 40 \Gamma = \frac{Z_L - Z_0}{Z_L + Z_0} = \frac{(30 - j40) - 50}{(30 - j40) + 50} = \frac{-20 - j40}{80 - j40} Γ = Z L + Z 0 Z L − Z 0 = ( 30 − j 40 ) + 50 ( 30 − j 40 ) − 50 = 80 − j 40 − 20 − j 40
Simplify by dividing numerator and denominator by 20 20 20 :
Γ = − 1 − j 2 4 − j 2 \Gamma = \frac{-1 - j2}{4 - j2} Γ = 4 − j 2 − 1 − j 2
Multiply numerator and denominator by the complex conjugate of the denominator ( 4 + j 2 4 + j2 4 + j 2 ):
Γ = ( − 1 − j 2 ) ( 4 + j 2 ) ( 4 − j 2 ) ( 4 + j 2 ) = − 4 − j 2 − j 8 − j 2 ( 4 ) 16 − j 2 ( 4 ) = − 4 − j 10 + 4 16 + 4 = 0 − j 10 20 = 0 − j 0.50 \Gamma = \frac{(-1 - j2)(4 + j2)}{(4 - j2)(4 + j2)} = \frac{-4 - j2 - j8 - j^2(4)}{16 - j^2(4)} = \frac{-4 - j10 + 4}{16 + 4} = \frac{0 - j10}{20} = 0 - j0.50 Γ = ( 4 − j 2 ) ( 4 + j 2 ) ( − 1 − j 2 ) ( 4 + j 2 ) = 16 − j 2 ( 4 ) − 4 − j 2 − j 8 − j 2 ( 4 ) = 16 + 4 − 4 − j 10 + 4 = 20 0 − j 10 = 0 − j 0.50
Compute the magnitude ∣ Γ ∣ |\Gamma| ∣Γ∣ :
∣ Γ ∣ = 0 2 + ( − 0.50 ) 2 = 0.50 |\Gamma| = \sqrt{0^2 + (-0.50)^2} = 0.50 ∣Γ∣ = 0 2 + ( − 0.50 ) 2 = 0.50
The phase angle is θ = − 90 ∘ \theta = -90^\circ θ = − 9 0 ∘ (purely capacitive reflection).
Compute VSWR:
VSWR = 1 + ∣ Γ ∣ 1 − ∣ Γ ∣ = 1 + 0.50 1 − 0.50 = 1.50 0.50 = 3.0 : 1 \text{VSWR} = \frac{1 + |\Gamma|}{1 - |\Gamma|} = \frac{1 + 0.50}{1 - 0.50} = \frac{1.50}{0.50} = 3.0:1 VSWR = 1 − ∣Γ∣ 1 + ∣Γ∣ = 1 − 0.50 1 + 0.50 = 0.50 1.50 = 3.0 : 1
Result: The reflection coefficient is Γ = 0.50 ∠ − 90 ∘ \Gamma = 0.50 \angle -90^\circ Γ = 0.50∠ − 9 0 ∘ , producing a VSWR \text{VSWR} VSWR of 3.0 : 1 3.0:1 3.0 : 1 .
Worked Example 2: Normalizing Coordinates on the Smith Chart
An antenna tuning network presents an input impedance of Z = 75 + j 100 Ω Z = 75 + j100\ \Omega Z = 75 + j 100 Ω . Determine its normalized coordinates on a standard 50 Ω 50\ \Omega 50 Ω Smith Chart, identify which hemisphere it occupies, and state the type of reactance present.
Calculation:
z = Z Z 0 = 75 + j 100 Ω 50 Ω = 75 50 + j ( 100 50 ) = 1.5 + j 2.0 z = \frac{Z}{Z_0} = \frac{75 + j100\ \Omega}{50\ \Omega} = \frac{75}{50} + j\left(\frac{100}{50}\right) = 1.5 + j2.0 z = Z 0 Z = 50 Ω 75 + j 100 Ω = 50 75 + j ( 50 100 ) = 1.5 + j 2.0
Analysis:
Normalized resistance r = 1.5 r = 1.5 r = 1.5 . The impedance lies along the r = 1.5 r = 1.5 r = 1.5 constant resistance circle.
Normalized reactance x = + 2.0 x = +2.0 x = + 2.0 . Because the reactance sign is positive, the point lies in the upper hemisphere of the Smith Chart, indicating inductive reactance .
Worked Example 3: Locating a Coaxial Cable Fault
An 80 -meter 80\text{-meter} 80 -meter dipole develops very high SWR. A VNA sweep from 1 MHz 1\text{ MHz} 1 MHz to 50 MHz 50\text{ MHz} 50 MHz shows that the unwrapped S 11 S_{11} S 11 phase of its open-ended feedline changes by 360 ∘ 360^\circ 36 0 ∘ every Δ f = 2.45 MHz \Delta f=2.45\text{ MHz} Δ f = 2.45 MHz . Assume one dominant end reflection and solid-polyethylene RG-213 with constant velocity factor v f = 0.66 v_f=0.66 v f = 0.66 . Estimate the distance to that end reflection.
Calculation:
For a nondispersive line, the reflected wave accumulates phase over the round-trip path 2 d 2d 2 d . A further 360 ∘ 360^\circ 36 0 ∘ phase change occurs for a frequency increment Δ f = v / ( 2 d ) \Delta f=v/(2d) Δ f = v / ( 2 d ) . An ideal open or short has ∣ Γ ∣ = 1 |\Gamma|=1 ∣Γ∣ = 1 ; the method uses phase rotation, not reflection-magnitude nulls:
Δ f = v 2 d = v f ⋅ c 2 d \Delta f = \frac{v}{2d} = \frac{v_f \cdot c}{2d} Δ f = 2 d v = 2 d v f ⋅ c
Rearranging to solve for distance d d d :
d = v f ⋅ c 2 ⋅ Δ f d = \frac{v_f \cdot c}{2 \cdot \Delta f} d = 2 ⋅ Δ f v f ⋅ c
Substitute the known values:
d = 0.66 × ( 3.00 × 10 8 m/s ) 2 × ( 2.45 × 10 6 Hz ) = 1.98 × 10 8 4.90 × 10 6 ≈ 40.41 meters d = \frac{0.66 \times (3.00 \times 10^8\text{ m/s})}{2 \times (2.45 \times 10^6\text{ Hz})} = \frac{1.98 \times 10^8}{4.90 \times 10^6} \approx 40.41\text{ meters} d = 2 × ( 2.45 × 1 0 6 Hz ) 0.66 × ( 3.00 × 1 0 8 m/s ) = 4.90 × 1 0 6 1.98 × 1 0 8 ≈ 40.41 meters
Result: The dominant end reflection is approximately 40.4 meters 40.4\text{ meters} 40.4 meters from the reference plane, using the stated velocity factor. Velocity-factor uncertainty, dispersion and measurement errors limit the physical accuracy.
Comparison Table: Impedance Diagnostic Instruments
- Feature / Metric Inline SWR Meter Scalar Antenna Analyser Vector Network Analyser (VNA)
- Signal Source Requires active transmitter power Built-in low-power oscillator (DDS) Built-in swept synthesiser
Parameters Measured Forward & reflected power magnitude Reflection coefficient magnitude ( ∣ Γ ∣ \lvert\Gamma\rvert ∣ Γ ∣ ) S 11 S_{11} S 11 & S 21 S_{21} S 21 (magnitude AND phase angle θ \theta θ )
Impedance Display VSWR; watts when calibrated for power VSWR and supported estimates of R R R , ∣ X ∣ \lvert X\rvert ∣ X ∣ , ∣ Z ∣ \lvert Z\rvert ∣ Z ∣ Signed R + j X R+jX R + j X and Smith Chart, within calibration/accuracy limits
Sign of Reactance None Blind (cannot distinguish + j X +jX + j X from − j X -jX − j X ) Explicit ( + j X +jX + j X inductive, − j X -jX − j X capacitive)
Two-Port Measurements Impossible Impossible Measures filter curves, gain, coax loss ( S 21 S_{21} S 21 )
Calibration Instrument calibration and/or forward-reference setting, depending on design Bridge calibration/compensation per manual Reflection or two-port calibration at the required reference plane
Cable Fault Location Impossible Manual calculation from SWR dips Automated high-resolution TDR / IFFT distance graph