Study guide
14.1 Spectrum Analyser Architecture, Operation, and Spectral Purity
ACMA Amateur Radio Advanced Recognition Certificate - Theory Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: DC Theory, Circuit Laws & Passive Components
1.1 DC Circuit Analysis, Ohm's Law, and Kirchhoff's Laws 1.2 AC Fundamentals, Sine Waves, Peak, RMS, and Phase Relationships 1.3 Inductance, Capacitance, Reactance, and Time Constants
2 Chapter 2: Impedance, Resonance & Passive Filters
2.1 Complex Impedance, Phasors, and AC Circuit Analysis 2.2 Series and Parallel LC Resonance and Q Factor 2.3 Passive Filters, Cutoff Frequency, and Attenuator Pads
3 Chapter 3: Semiconductor Devices & Power Supplies
3.1 Semiconductor Diodes, Zener Regulators, and Rectifier Circuits 3.2 Bipolar Junction Transistors, FETs, and Operational Amplifiers 3.3 Thermionic Valves (Vacuum Tubes) and High-Power Linear Amplifiers 3.4 DC Power Supplies, Filter Networks, and Voltage Regulators
4 Chapter 4: Oscillators & Frequency Synthesis
4.1 RF Oscillators, LC Tank Topologies, and Frequency Stability 4.2 Phase-Locked Loops (PLLs) and Frequency Synthesisers 4.3 Direct Digital Synthesis (DDS), SDR Architectures, and Digital Filter Topologies
5 Chapter 5: RF Amplifiers & Linearity
5.1 Classes of Amplification, Conduction Angles, and Operating Efficiency 5.2 RF Power Amplifiers, Push-Pull Topologies, and Output Matching 5.3 Amplifier Stability, Neutralisation, and Intermodulation Distortion
6 Chapter 6: Modulation & Demodulation
6.1 Amplitude Modulation, Double Sideband, and Single Sideband (SSB) 6.2 Frequency Modulation, Phase Modulation, and FM Detectors 6.3 Digital Modulation Modes, Spectral Efficiency, and Weak-Signal Protocols
7 Chapter 7: Transmitters, Mixers & Receivers
7.1 RF Mixers, Frequency Translation, and Intermodulation 7.2 Transmitter Architectures, CW Keying, and Output Filtering 7.3 Superheterodyne Receiver Design, IF Selection, and Image Rejection 7.4 Receiver Performance Specifications, Dynamic Range, and Selectivity
8 Chapter 8: Transmission Lines & Waveguides
8.1 Transmission Line Characteristics, Impedance, and Velocity Factor 8.2 Standing Waves, Reflection Coefficient, SWR, and Return Loss 8.3 Resonant Line Sections, Quarter-Wave Transformers, and Stubs
9 Chapter 9: Impedance Matching & Baluns
9.1 Lumped-Element Matching Networks and Antenna Tuning Units 9.2 Baluns, Ununs, and Common-Mode Current Choking 9.3 Feedline Losses, High-SWR Stress, and Coaxial Installation Practice
10 Chapter 10: Practical Antennas & Arrays
10.1 Resonant Dipoles, Inverted-Vs, and Multiband Wire Antennas 10.2 Quarter-Wave Verticals, Ground Systems, and Radiation Efficiency 10.3 Parasitic Arrays, Yagi-Uda Antennas, and Quad Arrays 10.4 Antenna Gain, Aperture Antennas & Horns, ERP/EIRP, Radiation Patterns
11 Chapter 11: Radio Wave Propagation & Ionospheric Mechanics
11.1 Electromagnetic Wave Fundamentals, Polarisation, and Ground Waves 11.2 The Ionosphere, Solar Radiation, and Solar Cycles 11.3 Critical Frequency, Maximum Usable Frequency, and HF Propagation Paths
12 Chapter 12: VHF/UHF Propagation & Space Communications
12.1 Line-of-Sight, Tropospheric Ducting, and Diffraction 12.2 Sporadic-E, Auroral Scatter, and Trans-Equatorial Propagation 12.3 Amateur Satellites, Doppler Shift, and Earth-Moon-Earth (EME)
13 Chapter 13: Test Equipment & RF Measurements
13.1 Decibels, Power Ratios, and Cascaded Stage Calculations 13.2 RF Power Meters, Directional Couplers, and Dummy Loads 13.3 Multirange Meters, Waveform Diagnostics, Oscilloscopes, and Frequency Counters
14 Chapter 14: Advanced RF Analysis & Diagnostics
14.1 Spectrum Analyser Architecture, Operation, and Spectral Purity 14.2 Antenna Analysers, Vector Network Analysers, and Smith Charts 14.3 Calibrated Signal Generators, Grid Dip Meters, and Component Testing
15 Chapter 15: Electromagnetic Compatibility & Interference
15.1 Sources of Interference, Coupling Mechanisms, and Audio Rectification 15.2 Receiver Susceptibility, Desensitisation, and Front-End Intermodulation 15.3 Practical RFI Suppression, Filter Design, and Bonding Techniques
16 Chapter 16: Electrical, RF & Station Safety
16.1 Biological Effects of RF Energy and ARPANSA Exposure Standards 16.2 Safe Separation Distances, Power Density, and Duty Cycles 16.3 Station Electrical Safety, Battery Hazards, and Safe Headphone Use 16.4 Mast and Tower Construction, Power Line Clearance, and Lightning Protection
14.1 Spectrum Analyser Architecture, Operation, and Spectral Purity
Key Takeaways Explain This Topic AI
Oscilloscopes display signals in the time domain (instantaneous amplitude versus time), whereas spectrum analysers display signals in the frequency domain (signal power versus frequency) based on Fourier transform principles.
The swept-tuned superheterodyne spectrum analyser routes signals through an input step attenuator, mixer, swept local oscillator (YIG or DDS/PLL), resolution bandwidth (RBW) filter, logarithmic amplifier, envelope detector, and video bandwidth (VBW) filter.
For conventional swept analog resolution filters, T sweep ≳ k Span / RBW 2 T_{\text{sweep}} \gtrsim k\,\text{Span}/\text{RBW}^2 T sweep ≳ k Span / RBW 2 , with k k k typically 2 – 3 2–3 2–3 . Sweeping too fast causes amplitude and frequency errors. FFT processing uses a different timing relationship.
Reducing Resolution Bandwidth (RBW) by a factor of 10 drops the Displayed Average Noise Floor (DANL) by 10 dB 10\text{ dB} 10 dB , revealing low-level signals, while Video Bandwidth (VBW) smooths trace noise fluctuations without changing the mean noise floor.
Under class-licence section 15, spurious attenuation is the lesser of 43 + 10 log 10 ( p X ) 43+10\log_{10}(pX) 43 + 10 lo g 10 ( pX ) and 50 50 50 dB below 30 MHz 30\text{ MHz} 30 MHz , or the lesser of 43 + 10 log 10 ( P ) 43+10\log_{10}(P) 43 + 10 lo g 10 ( P ) and 70 70 70 dB at or above it. Below 30 MHz 30\text{ MHz} 30 MHz , a 100 W 100\text{ W} 100 W PEP emission therefore requires 50 dB 50\text{ dB} 50 dB , not 60 dB 60\text{ dB} 60 dB .
Last updated: November 2026
14.1 Spectrum Analyser Architecture, Operation, and Spectral Purity
Radio frequency (RF) engineering requires evaluating signals across two complementary perspectives: the time domain and the frequency domain . While an oscilloscope graphs instantaneous voltage as a function of time, complex multi-frequency RF phenomena—such as harmonic emissions, intermodulation distortion (IMD), sideband splatter, and phase noise skirts—are exceedingly difficult or impossible to quantify from an oscilloscope trace. The spectrum analyser is the preeminent laboratory instrument for frequency-domain characterisation, decomposing an incoming waveform into its individual spectral constituents and graphing signal power against frequency. Time Domain (Oscilloscope) Frequency Domain (Spectrum Analyser)
Voltage vs. Time Power (dBm) vs. Frequency (Hz)
- V ^ /\ /\ P ^ Fundamental
- | / \ / \ | |
- | /\ / \ /\ / \ | | 2nd Harm 3rd Harm
- +--/-\-/------\/--/-\------> | | | |
- 0| / V \ / V Time | ||| ||| |||
- v v +----|||--------|||--------|||----->
- Ref f_0 2f_0 3f_0 Freq
The mathematical bridge connecting these two domains is the Fourier Transform . Fourier analysis represents a periodic waveform by its mean (DC component) plus harmonically related sinusoidal components with their respective amplitudes and phases. A pure sine wave in the time domain yields a solitary discrete spectral line (a Dirac delta function) in the frequency domain. Conversely, non-sinusoidal waveforms—such as square waves, pulses, or overdriven amplifier outputs—contain rich arrays of harmonics extending far into the electromagnetic spectrum.
Swept-Tuned Superheterodyne Spectrum Analyser Architecture
Although modern real-time and Fast Fourier Transform (FFT) spectrum analysers exist, the fundamental architecture underlying high-performance RF spectrum analysers is the swept-tuned superheterodyne receiver. This topology converts a wide swath of input radio frequencies into a fixed intermediate frequency (IF) where precision narrow-band filtering, amplification, and detection take place. Conventional Swept-Tuned Analyser: Signal Path
- RF --> [Input attenuator] --> [LPF/preselector] --> [1st mixer]
- ^ |
- Swept LO v
- [1st IF filter]
- |
- [Further conversion]
- |
- [Final IF / RBW filter]
- |
- [Log amp / envelope detector]
- |
- [VBW filter / ADC] --> Display
Sweep control --> Swept LO; the same sweep supplies the frequency axis.
Detailed Analysis of Internal Functional Blocks
Input Step Attenuator ( 0 to 50 − 70 dB 0\text{ to }50-70\text{ dB} 0 to 50 − 70 dB ): The input attenuator reduces the level reaching the mixer to control overload, compression and internally generated distortion. The appropriate mixer level depends on the analyser and the required distortion measurement; it is not a universal threshold. Input attenuation and IF gain are normally coupled to the reference-level setting so that displayed amplitudes remain calibrated. Too much attenuation raises the input-referred noise floor.
Input Low-Pass Filter / Preselector: To prevent image responses and spurious harmonic mixing from reaching the first IF, input signals pass through a low-pass or tunable tracking bandpass filter (preselector). In modern microwave analysers, this filter prevents signals above the analyser's first conversion band from entering the mixer.
First Mixer and Swept Local Oscillator (LO): The mixer combines the input RF signal ( f RF f_{\text{RF}} f RF ) with the output of a swept Voltage-Controlled Oscillator (VCO), typically a Yttrium Iron Garnet (YIG) tuned oscillator or a fractional-N PLL synthesiser. A sawtooth ramp generator sweeps the LO frequency linearly across a designated range. High-performance analysers employ an up-converting architecture , setting the first intermediate frequency ( f IF f_{\text{IF}} f IF ) higher than the highest input tuning frequency (e.g., an IF of 3.1 GHz 3.1\text{ GHz} 3.1 GHz for an analyser covering 0 to 3.0 GHz 0\text{ to }3.0\text{ GHz} 0 to 3.0 GHz ). Placing the IF above the input band pushes the image frequency ( f image = f LO + f IF f_{\text{image}} = f_{\text{LO}} + f_{\text{IF}} f image = f LO + f IF ) up into microwave territory ( > 6.2 GHz > 6.2\text{ GHz} > 6.2 GHz ), where it can be eliminated with a simple fixed low-pass input filter.
Intermediate Frequency (IF) Filter — Resolution Bandwidth (RBW): The mixed signal is directed through a chain of bandpass filters. The narrowest filter in the chain defines the Resolution Bandwidth (RBW) . The RBW filter is typically implemented with a Gaussian response shape to prevent ringing and overshoot during continuous sweeping. The bandwidth of this filter dictates the analyser's ability to separate closely spaced frequency components.
Logarithmic Amplifier: Because RF signal powers span orders of magnitude—from microwatts to hundreds of watts, or nanowatts in receiver testing—a linear voltage display would compress weak signals into the baseline noise. The logarithmic amplifier applies a non-linear transfer function ( V out ∝ log 10 ( V in ) V_{\text{out}} \propto \log_{10}(V_{\text{in}}) V out ∝ lo g 10 ( V in ) ), compressing a 100 dB 100\text{ dB} 100 dB power dynamic range into a standard display grid calibrated in decibels relative to one milliwatt ( dBm \text{dBm} dBm ) at 10 dB 10\text{ dB} 10 dB per vertical division.
Envelope Detector: An envelope detector removes the IF carrier and produces a voltage following its amplitude envelope. The selected detector and subsequent averaging/processing determine the displayed signal level; envelope voltage is not itself a direct average-power measurement.
Video Filter — Video Bandwidth (VBW): Following envelope detection, the signal is a baseband direct-current voltage fluctuating with modulation or noise. It passes through a variable low-pass filter designated the Video Filter , whose cut-off frequency is the Video Bandwidth (VBW) . The video filter smooths rapid, high-frequency noise spikes, acting as a signal averager to clarify low-level signals obscured near the noise floor.
Display Generator / ADC: An Analog-to-Digital Converter (ADC) samples the detected video voltage. In synchronism with the horizontal sweep ramp, the display plots signal amplitude on the vertical Y-axis (in dBm \text{dBm} dBm or dB μ V \text{dB}\mu\text{V} dB μ V ) against frequency on the horizontal X-axis (in kHz \text{kHz} kHz , MHz \text{MHz} MHz , or GHz \text{GHz} GHz ).
Operating Controls and Measurement Constraints
Operating a spectrum analyser requires balancing three interconnected parameters: Span , Resolution Bandwidth (RBW) , and Sweep Time ( T sweep T_{\text{sweep}} T sweep ) . Adjusting any one parameter directly affects the physical validity of the measurement. The RBW Filtering Effect
- Wide RBW (e.g., 10 kHz) Narrow RBW (e.g., 300 Hz)
- Cannot resolve 1 kHz tones Resolves both tones + IMD products
- Power ^ Power ^
- | ____ | /\ /\
- | / \ <-- Merged peak | / \ / \ <-- Deep valley
- | / \ | / \ / \ revealed
- | / \ | / \/ \
- +---/----------\----------> +---/----------------\----->
- f_1 f_2 Freq f_1 f_2 Freq
- 1. Resolution Bandwidth (RBW) and Frequency Resolution
The RBW setting defines the frequency resolution of the analyser. When two equal-amplitude sinusoidal signals spaced by Δ f \Delta f Δ f enter the analyser, their individual responses merge into a single broad peak unless the RBW is narrower than their separation:
RBW ≤ Δ f \text{RBW} \le \Delta f RBW ≤ Δ f
In practical amateur transmitter testing—such as an audio two-tone intermodulation test where two tones are separated by 1.0 kHz 1.0\text{ kHz} 1.0 kHz —an RBW of 3 kHz 3\text{ kHz} 3 kHz or 10 kHz 10\text{ kHz} 10 kHz completely obscures the individual tones, showing only an aggregated hump. To display a deep valley (at least 10 to 20 dB 10\text{ to }20\text{ dB} 10 to 20 dB drop) between the 1 kHz 1\text{ kHz} 1 kHz tones and expose the adjacent 3rd-order IMD sidebands, the operator must select an RBW ≤ 300 Hz \text{RBW} \le 300\text{ Hz} RBW ≤ 300 Hz (or 100 Hz 100\text{ Hz} 100 Hz ).
2. The Sweep Time Constraint and Filter Ringing
An IF bandpass filter is a physical tuned resonator possessing stored energy and a finite rise/settling time. The time required for the Gaussian IF filter to charge up to full amplitude when an RF signal sweeps across its passband is inversely proportional to the filter's bandwidth:
t settle ≈ 1 RBW t_{\text{settle}} \approx \frac{1}{\text{RBW}} t settle ≈ RBW 1
If the local oscillator sweeps across the filter's passband faster than the filter can respond, energy cannot build up to its true steady-state level. The sweep velocity is defined as the frequency span divided by the sweep time ( Span / T sweep \text{Span} / T_{\text{sweep}} Span / T sweep in Hz/s \text{Hz/s} Hz/s ). To avoid distortion, the sweep velocity must not exceed a fraction of the filter bandwidth squared:
Span T sweep ≤ RBW 2 k \frac{\text{Span}}{T_{\text{sweep}}} \le \frac{\text{RBW}^2}{k} T sweep Span ≤ k RBW 2
Rearranging yields the fundamental Minimum Sweep Time Formula :
T sweep ≥ k ⋅ Span RBW 2 T_{\text{sweep}} \ge k \cdot \frac{\text{Span}}{\text{RBW}^2} T sweep ≥ k ⋅ RBW 2 Span
where k k k is a filter-response constant, typically 2.0 2.0 2.0 to 3.0 3.0 3.0 for conventional near-Gaussian analog resolution filters. FFT analysis processes frequency blocks and can be much faster; its acquisition time is not obtained merely by substituting a smaller fixed k k k into this swept-filter equation.
Caution
For a conventional swept measurement, a sweep faster than the resolution filter can settle under-reports the peak amplitude and displaces its indicated frequency. The response can also become asymmetric. The amount of error depends on the filter and sweep rate; it is not a fixed number of decibels.
Use the analyser's coupled automatic timing, or verify a manually chosen sweep against its specified settling requirements. Many swept analysers flag an excessively fast setting as “UNCAL” or “Meas Uncal”.
3. Displayed Average Noise Floor (DANL)
The Displayed Average Noise Floor (DANL) represents the internal thermal noise floor of the spectrum analyser, setting the absolute limit on the weakest signals the instrument can detect. Thermal noise power is governed by Johnson-Nyquist physics:
P n = k ⋅ T ⋅ B P_n = k \cdot T \cdot B P n = k ⋅ T ⋅ B
where k k k is Boltzmann's constant ( 1.38 × 10 − 23 J/K 1.38 \times 10^{-23}\text{ J/K} 1.38 × 1 0 − 23 J/K ), T T T is temperature in Kelvin, and B B B is the measurement bandwidth, which is determined directly by the RBW .
Expressed in decibels relative to one milliwatt:
DANL ∝ 10 log 10 ( RBW ) \text{DANL} \propto 10 \log_{10}(\text{RBW}) DANL ∝ 10 lo g 10 ( RBW )
Important
Every time the Resolution Bandwidth (RBW) is reduced by a factor of 10 (for example, from 10 kHz 10\text{ kHz} 10 kHz to 1 kHz 1\text{ kHz} 1 kHz , or 1 kHz 1\text{ kHz} 1 kHz to 100 Hz 100\text{ Hz} 100 Hz ), the internal noise power passing through the IF filter decreases by a factor of 10, lowering the displayed noise floor by exactly 10 dB 10\text{ dB} 10 dB .
Furthermore, the input step attenuator directly degrades DANL. Inserting 20 dB 20\text{ dB} 20 dB of input attenuation attenuates external noise and signals equally while internal mixer noise remains constant, raising the effective noise floor on the screen by 20 dB 20\text{ dB} 20 dB . Therefore, to detect microvolt-level signals, set input attenuation to 0 dB 0\text{ dB} 0 dB (or use an internal preamplifier) and select the narrowest practical RBW.
4. Video Bandwidth (VBW) vs. Resolution Bandwidth (RBW)
A common misconception is confusing RBW with Video Bandwidth (VBW):
Parameter Stage Functional Mechanism Effect on Noise Floor
Resolution Bandwidth (RBW) Pre-detector (IF bandpass filter) Restricts total RF/IF power entering detector Lowers average noise floor by 10 dB 10\text{ dB} 10 dB per decade reduction. Resolves adjacent tones.
Video Bandwidth (VBW) Post-detector (Baseband low-pass filter) Low-pass filters rectified DC video voltage Does NOT change average noise floor . Smooths peak-to-peak noise fuzz, revealing signals buried in noise grass.
Selecting a VBW significantly smaller than RBW (e.g., VBW = 0.1 × RBW \text{VBW} = 0.1 \times \text{RBW} VBW = 0.1 × RBW ) replaces a noisy, jagged noise band ( 5 − 8 dB 5-8\text{ dB} 5 − 8 dB peak-to-peak variation) with a clean, razor-thin line representing the true mathematical mean noise level.
- Practical Amateur Radio Spectral Measurements Harmonic measurement
- Power ^
- | |
- | |
- | | | |
- +-----------+-------------+-------------+----------------> Frequency
- f0 2f0 3f0
Compare each harmonic with the wanted signal using the applicable
section15 frequency/power-dependent requirement.
- Equal-tone IMD spectrum
- PEP reference: 6.02 dB above either equal wanted tone
- | - - - - - - - - - - - - - - - - - - - - - - -
- | | |
- | | |
- | | | | |
- +-----+-------------+-------------+-------------+--------> Frequency
- 2f1-f2 f1 f2 2f2-f1
Each outer third-order product is one tone-spacing beyond the wanted pair.
1. Harmonic Attenuation and ACMA Compliance
Non-linear transmitter stages generate harmonics at integer multiples of the wanted frequency. For operation under the Radiocommunications (Amateur Stations) Class Licence 2023 , section 15 requires spurious emissions to be attenuated below the power within the emission's necessary bandwidth, supplied to the antenna transmission line, by:
Below 30 MHz 30\text{ MHz} 30 MHz : the lesser of 43 + 10 log 10 ( p X ) 43 + 10\log_{10}(pX) 43 + 10 lo g 10 ( pX ) dB and 50 dB 50\text{ dB} 50 dB , where p X pX pX is PEP in watts.
At or above 30 MHz 30\text{ MHz} 30 MHz : the lesser of 43 + 10 log 10 ( P ) 43 + 10\log_{10}(P) 43 + 10 lo g 10 ( P ) dB and 70 dB 70\text{ dB} 70 dB , where P P P is the power in watts supplied to the antenna transmission line. There is no 25 W 25\text{ W} 25 W breakpoint in this rule.
Measurement Procedure:
Rated Attenuation: Never connect a power transmitter directly to the analyser. Use a suitably rated 50 Ω 50\ \Omega 50 Ω power attenuator, or a calibrated coupler with the main line terminated in a rated load. For example, 100 W 100\text{ W} 100 W ( + 50 dBm +50\text{ dBm} + 50 dBm ) through 40 dB 40\text{ dB} 40 dB attenuation gives + 10 dBm +10\text{ dBm} + 10 dBm at the analyser connector. Check its actual input/DC limits and select sufficient internal attenuation for a linear mixer-level measurement.
Reference and Frequency Response: Measure a steady carrier into the load. Set the reference level and span to display the fundamental and required harmonics, with suitable RBW and automatic sweep time. Account for the attenuator/coupler and cable response at each frequency; equal nominal attenuation does not establish equal calibrated response.
Delta Markers and Distortion Check: Compare each harmonic with the fundamental using delta markers and the path corrections. Repeat with more analyser input attenuation: an external component retains its corrected input level, whereas an internally generated distortion product changes. Ensure the harmonic remains above the noise before accepting the result.
2. Measuring Intermodulation Distortion (IMD) in SSB Transmitters
Single Sideband (SSB) requires linear amplification. Non-linearities in RF power transistors generate mixing between spectral components. In standard two-tone testing, two non-harmonically related audio tones (such as 700 Hz 700\text{ Hz} 700 Hz and 1900 Hz 1900\text{ Hz} 1900 Hz , separated by 1200 Hz 1200\text{ Hz} 1200 Hz ) are injected into the transmitter microphone input, producing two RF carrier tones at f 1 f_1 f 1 and f 2 f_2 f 2 .
Non-linear power amplifier transfer curves generate odd-order mixing products that fall directly within or immediately adjacent to the transmitter passband:
Third-Order Products ( 2 f 1 − f 2 2f_1 - f_2 2 f 1 − f 2 and 2 f 2 − f 1 2f_2 - f_1 2 f 2 − f 1 ): Located on either side of the two tones, spaced by exactly 1.2 kHz 1.2\text{ kHz} 1.2 kHz .
Fifth-Order Products ( 3 f 1 − 2 f 2 3f_1 - 2f_2 3 f 1 − 2 f 2 and 3 f 2 − 2 f 1 3f_2 - 2f_1 3 f 2 − 2 f 1 ): Spaced by 2.4 kHz 2.4\text{ kHz} 2.4 kHz .
The Crucial PEP Reference Distinction:
When quantifying IMD, two reference conventions exist in engineering:
Referenced to One of the Two Equal Tones (dBc): This is read directly off the spectrum analyser screen as the height difference between the peak of tone f 1 f_1 f 1 and the peak of the 3rd-order product ( 2 f 1 − f 2 2f_1 - f_2 2 f 1 − f 2 ). In high-grade amateur equipment, this ratio is typically − 30 dBc -30\text{ dBc} − 30 dBc to − 36 dBc -36\text{ dBc} − 36 dBc .
Referenced to Peak Envelope Power (PEP): Because two equal tones combining in phase double the peak voltage ( V PEP = 2 V single V_{\text{PEP}} = 2 V_{\text{single}} V PEP = 2 V single ), the peak envelope power is four times the single-tone average power ( + 6 dB +6\text{ dB} + 6 dB higher):
P PEP = 4 P single , P PEP (dBm) = P single (dBm) + 6.02 dB P_{\text{PEP}} = 4P_{\text{single}}, \qquad P_{\text{PEP}}\text{ (dBm)} = P_{\text{single}}\text{ (dBm)} + 6.02\text{ dB} P PEP = 4 P single , P PEP (dBm) = P single (dBm) + 6.02 dB
Tip
Relative to PEP, an IMD product has a ratio about 6 dB 6\text{ dB} 6 dB more negative than its ratio to one equal tone: − 30 dBc -30\text{ dBc} − 30 dBc relative to a tone becomes − 36 dB -36\text{ dB} − 36 dB relative to PEP. The suppression magnitude is larger, but the transmitter’s emitted spectrum has not changed.
3. Local Oscillator Phase Noise Skirts
No real-world oscillator generates an infinitely thin spectral line. Phase fluctuations and thermal noise modulate the oscillator, creating symmetrical noise "skirts" spreading out on either side of the carrier. This is phase noise , quantified in decibels relative to the carrier per unit bandwidth:
L ( Δ f ) in dBc/Hz \mathcal{L}(\Delta f) \quad \text{in } \text{dBc/Hz} L ( Δ f ) in dBc/Hz
at a specified frequency offset Δ f \Delta f Δ f (such as 10 kHz 10\text{ kHz} 10 kHz or 100 kHz 100\text{ kHz} 100 kHz ).
In amateur radio receivers, excessive local oscillator phase noise causes reciprocal mixing : when a strong adjacent-channel signal (e.g., 20 kHz 20\text{ kHz} 20 kHz away in a contest) enters the mixer, the LO phase noise skirts mix with the strong signal, transferring noise directly into the receiver's IF passband and completely masking weak desired signals.
- Step-by-Step Worked Measurement Calculations
- Worked Example 1: Minimum Sweep Time Calculation
An operator is conducting an in-depth spectral analysis of an HF transmitter over a span of Span = 500 kHz \text{Span} = 500\text{ kHz} Span = 500 kHz to inspect sideband splatter. To clearly resolve 1 kHz 1\text{ kHz} 1 kHz modulation products, the Resolution Bandwidth is set to RBW = 300 Hz \text{RBW} = 300\text{ Hz} RBW = 300 Hz . The analyser uses an analog Gaussian filter with shape constant k = 2.5 k = 2.5 k = 2.5 . Calculate the minimum sweep time required to prevent uncalibrated filter ringing and amplitude compression.
Calculation:
T sweep ≥ k ⋅ Span RBW 2 T_{\text{sweep}} \ge k \cdot \frac{\text{Span}}{\text{RBW}^2} T sweep ≥ k ⋅ RBW 2 Span
Substitute the known values:
T sweep ≥ 2.5 ⋅ 500 × 10 3 Hz ( 300 Hz ) 2 T_{\text{sweep}} \ge 2.5 \cdot \frac{500 \times 10^3\text{ Hz}}{(300\text{ Hz})^2} T sweep ≥ 2.5 ⋅ ( 300 Hz ) 2 500 × 1 0 3 Hz
( 300 ) 2 = 90,000 Hz 2 (300)^2 = 90{,}000\text{ Hz}^2 ( 300 ) 2 = 90 , 000 Hz 2
T sweep ≥ 2.5 ⋅ 500,000 90,000 = 2.5 ⋅ 5.5556 ≈ 13.89 seconds T_{\text{sweep}} \ge 2.5 \cdot \frac{500{,}000}{90{,}000} = 2.5 \cdot 5.5556 \approx 13.89\text{ seconds} T sweep ≥ 2.5 ⋅ 90 , 000 500 , 000 = 2.5 ⋅ 5.5556 ≈ 13.89 seconds
Result: The sweep time must be set to at least 14 seconds 14\text{ seconds} 14 seconds . Forcing a 1 1 1 -second or 500 ms 500\text{ ms} 500 ms sweep would result in severe amplitude errors and illuminate the "UNCAL" indicator.
Worked Example 2: DANL Noise Floor Reduction
A spectrum analyser is configured with RBW = 100 kHz \text{RBW} = 100\text{ kHz} RBW = 100 kHz , displaying an average noise floor of − 95 dBm -95\text{ dBm} − 95 dBm . To detect a weak spurious emission at − 120 dBm -120\text{ dBm} − 120 dBm , the operator reduces the RBW to 100 Hz 100\text{ Hz} 100 Hz . What is the new Displayed Average Noise Floor, and will the spurious signal be visible?
Calculation:
Determine the ratio of bandwidth reduction:
Ratio = RBW new RBW initial = 100 Hz 100,000 Hz = 10 − 3 \text{Ratio} = \frac{\text{RBW}_{\text{new}}}{\text{RBW}_{\text{initial}}} = \frac{100\text{ Hz}}{100{,}000\text{ Hz}} = 10^{-3} Ratio = RBW initial RBW new = 100 , 000 Hz 100 Hz = 1 0 − 3
Compute the noise floor change in decibels:
Δ P noise = 10 log 10 ( 10 − 3 ) = − 30 dB \Delta P_{\text{noise}} = 10 \log_{10}(10^{-3}) = -30\text{ dB} Δ P noise = 10 lo g 10 ( 1 0 − 3 ) = − 30 dB
Calculate the new DANL:
DANL new = − 95 dBm + ( − 30 dB ) = − 125 dBm \text{DANL}_{\text{new}} = -95\text{ dBm} + (-30\text{ dB}) = -125\text{ dBm} DANL new = − 95 dBm + ( − 30 dB ) = − 125 dBm
Result: The noise floor drops by 30 dB 30\text{ dB} 30 dB to − 125 dBm -125\text{ dBm} − 125 dBm . The − 120 dBm -120\text{ dBm} − 120 dBm spurious emission will be clearly visible, standing 5 dB 5\text{ dB} 5 dB above the noise floor.
Worked Example 3: Harmonic Compliance Calculation
An amateur linear amplifier delivers 100 W 100\text{ W} 100 W ( + 50 dBm +50\text{ dBm} + 50 dBm ) of RF power at 7.10 MHz 7.10\text{ MHz} 7.10 MHz into a 40 dB 40\text{ dB} 40 dB power attenuator feeding a spectrum analyser. The fundamental signal registers at + 10 dBm +10\text{ dBm} + 10 dBm on the screen. The second harmonic at 14.20 MHz 14.20\text{ MHz} 14.20 MHz registers at − 53 dBm -53\text{ dBm} − 53 dBm on the screen. Determine:
The attenuation of the second harmonic relative to the carrier ( dBc \text{dBc} dBc ).
Whether this second harmonic meets the applicable below-30-MHz class-licence attenuation requirement, assuming the measurement path is calibrated at both frequencies.
Calculation:
Compute the relative harmonic attenuation:
Suppression (dBc) = P harmonic − P fundamental = − 53 dBm − ( + 10 dBm ) = − 63 dBc \text{Suppression (dBc)} = P_{\text{harmonic}} - P_{\text{fundamental}} = -53\text{ dBm} - (+10\text{ dBm}) = -63\text{ dBc} Suppression (dBc) = P harmonic − P fundamental = − 53 dBm − ( + 10 dBm ) = − 63 dBc
Evaluate regulatory compliance:
For 100 W 100\text{ W} 100 W PEP below 30 MHz 30\text{ MHz} 30 MHz , section 15 requires the lesser of 43 + 10 log 10 ( 100 ) = 63 dB 43 + 10\log_{10}(100) = 63\text{ dB} 43 + 10 lo g 10 ( 100 ) = 63 dB and 50 dB 50\text{ dB} 50 dB : therefore 50 dB 50\text{ dB} 50 dB .
Result: This second harmonic is 63 dB 63\text{ dB} 63 dB below the wanted signal, a 13 dB 13\text{ dB} 13 dB margin over that requirement. This checks the measured harmonic under the stated calibration assumptions; other spurious emissions and licence conditions must be checked separately.
Comparison Table: Spectrum Analyser Front-Panel Controls
Control Parameter Domain / Location Primary Functional Purpose Impact of Improper Setting
Input Attenuator RF Input Stage ( 50 Ω 50\ \Omega 50 Ω ) Protects 1st mixer from damage; maintains mixer linearity; sets reference level Too low: mixer overload and spurious internal IMD. Too high: elevates noise floor, masking weak signals.
Resolution Bandwidth (RBW) IF Stage (Gaussian Bandpass Filter) Establishes frequency resolution; defines selectivity between adjacent spectral components Too wide: closely spaced signals merge. Too narrow: increases conventional analog sweep time approximately as the inverse square of RBW.
Video Bandwidth (VBW) Post-Detector (Low-Pass Filter) Averages and smooths high-frequency noise grass; clarifies signals near noise floor Too wide: noise fluctuations obscure weak signals. Too narrow: excessively slows sweep time without improving selectivity.
Frequency Span Local Oscillator Sweep Range Sets total frequency spectrum displayed across horizontal screen axis ( f stop − f start f_{\text{stop}} - f_{\text{start}} f stop − f start ) Too wide: fine spectral detail compressed into single pixel. Too narrow: out-of-band harmonics missed.
Sweep Time ( T sweep T_{\text{sweep}} T sweep ) Ramp Generator / Tuning Rate Controls rate at which LO sweeps across the designated frequency span Too fast: violates T sweep ≥ k ⋅ Span / RBW 2 T_{\text{sweep}} \ge k \cdot \text{Span} / \text{RBW}^2 T sweep ≥ k ⋅ Span / RBW 2 , causing amplitude loss, frequency error, and "UNCAL".