Study guide
9.2 Baluns, Ununs, and Common-Mode Current Choking
ACMA Amateur Radio Advanced Recognition Certificate - Theory Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: DC Theory, Circuit Laws & Passive Components
1.1 DC Circuit Analysis, Ohm's Law, and Kirchhoff's Laws 1.2 AC Fundamentals, Sine Waves, Peak, RMS, and Phase Relationships 1.3 Inductance, Capacitance, Reactance, and Time Constants
2 Chapter 2: Impedance, Resonance & Passive Filters
2.1 Complex Impedance, Phasors, and AC Circuit Analysis 2.2 Series and Parallel LC Resonance and Q Factor 2.3 Passive Filters, Cutoff Frequency, and Attenuator Pads
3 Chapter 3: Semiconductor Devices & Power Supplies
3.1 Semiconductor Diodes, Zener Regulators, and Rectifier Circuits 3.2 Bipolar Junction Transistors, FETs, and Operational Amplifiers 3.3 Thermionic Valves (Vacuum Tubes) and High-Power Linear Amplifiers 3.4 DC Power Supplies, Filter Networks, and Voltage Regulators
4 Chapter 4: Oscillators & Frequency Synthesis
4.1 RF Oscillators, LC Tank Topologies, and Frequency Stability 4.2 Phase-Locked Loops (PLLs) and Frequency Synthesisers 4.3 Direct Digital Synthesis (DDS), SDR Architectures, and Digital Filter Topologies
5 Chapter 5: RF Amplifiers & Linearity
5.1 Classes of Amplification, Conduction Angles, and Operating Efficiency 5.2 RF Power Amplifiers, Push-Pull Topologies, and Output Matching 5.3 Amplifier Stability, Neutralisation, and Intermodulation Distortion
6 Chapter 6: Modulation & Demodulation
6.1 Amplitude Modulation, Double Sideband, and Single Sideband (SSB) 6.2 Frequency Modulation, Phase Modulation, and FM Detectors 6.3 Digital Modulation Modes, Spectral Efficiency, and Weak-Signal Protocols
7 Chapter 7: Transmitters, Mixers & Receivers
7.1 RF Mixers, Frequency Translation, and Intermodulation 7.2 Transmitter Architectures, CW Keying, and Output Filtering 7.3 Superheterodyne Receiver Design, IF Selection, and Image Rejection 7.4 Receiver Performance Specifications, Dynamic Range, and Selectivity
8 Chapter 8: Transmission Lines & Waveguides
8.1 Transmission Line Characteristics, Impedance, and Velocity Factor 8.2 Standing Waves, Reflection Coefficient, SWR, and Return Loss 8.3 Resonant Line Sections, Quarter-Wave Transformers, and Stubs
9 Chapter 9: Impedance Matching & Baluns
9.1 Lumped-Element Matching Networks and Antenna Tuning Units 9.2 Baluns, Ununs, and Common-Mode Current Choking 9.3 Feedline Losses, High-SWR Stress, and Coaxial Installation Practice
10 Chapter 10: Practical Antennas & Arrays
10.1 Resonant Dipoles, Inverted-Vs, and Multiband Wire Antennas 10.2 Quarter-Wave Verticals, Ground Systems, and Radiation Efficiency 10.3 Parasitic Arrays, Yagi-Uda Antennas, and Quad Arrays 10.4 Antenna Gain, Aperture Antennas & Horns, ERP/EIRP, Radiation Patterns
11 Chapter 11: Radio Wave Propagation & Ionospheric Mechanics
11.1 Electromagnetic Wave Fundamentals, Polarisation, and Ground Waves 11.2 The Ionosphere, Solar Radiation, and Solar Cycles 11.3 Critical Frequency, Maximum Usable Frequency, and HF Propagation Paths
12 Chapter 12: VHF/UHF Propagation & Space Communications
12.1 Line-of-Sight, Tropospheric Ducting, and Diffraction 12.2 Sporadic-E, Auroral Scatter, and Trans-Equatorial Propagation 12.3 Amateur Satellites, Doppler Shift, and Earth-Moon-Earth (EME)
13 Chapter 13: Test Equipment & RF Measurements
13.1 Decibels, Power Ratios, and Cascaded Stage Calculations 13.2 RF Power Meters, Directional Couplers, and Dummy Loads 13.3 Multirange Meters, Waveform Diagnostics, Oscilloscopes, and Frequency Counters
14 Chapter 14: Advanced RF Analysis & Diagnostics
14.1 Spectrum Analyser Architecture, Operation, and Spectral Purity 14.2 Antenna Analysers, Vector Network Analysers, and Smith Charts 14.3 Calibrated Signal Generators, Grid Dip Meters, and Component Testing
15 Chapter 15: Electromagnetic Compatibility & Interference
15.1 Sources of Interference, Coupling Mechanisms, and Audio Rectification 15.2 Receiver Susceptibility, Desensitisation, and Front-End Intermodulation 15.3 Practical RFI Suppression, Filter Design, and Bonding Techniques
16 Chapter 16: Electrical, RF & Station Safety
16.1 Biological Effects of RF Energy and ARPANSA Exposure Standards 16.2 Safe Separation Distances, Power Density, and Duty Cycles 16.3 Station Electrical Safety, Battery Hazards, and Safe Headphone Use 16.4 Mast and Tower Construction, Power Line Clearance, and Lightning Protection
9.2 Baluns, Ununs, and Common-Mode Current Choking
Key Takeaways Explain This Topic AI
Coax carries differential return current on the shield interior and can carry a separate common-mode current on its exterior. Direct connection to a balanced antenna can excite that exterior path.
Common-mode current can alter the antenna pattern, cause RF feedback or burns, and couple local noise into the receiver. Its size and effects depend on the antenna, feedline route and return paths.
Current baluns add impedance to the common-mode path and encourage equal and opposite antenna currents. Differential flux ideally cancels, but common-mode flux, cable loss, core heating and component ratings still limit operation.
A 9:1 unun ideally transforms a given 450 + j 0 Ω 450+j0\ \Omega 450 + j 0 Ω unbalanced load to 50 + j 0 Ω 50+j0\ \Omega 50 + j 0 Ω . An end-fed wire’s complex impedance varies with frequency and installation, so this ratio does not guarantee a match across bands.
Ferrite mix, core dimensions, winding and parasitic capacitance determine a choke’s impedance versus frequency. Resistive ferrite loss can broaden useful choking; both ferrite and air-core designs require checks over the intended bands.
Last updated: November 2026
9.2 Baluns, Ununs, and Common-Mode Current Choking
An antenna system consists not merely of the radiating wire or tubing in the air, but of the entire electromagnetic assembly comprising the transmitter, feedline, matching transformers, and ground environment. A persistent source of station dysfunction—manifesting as distorted radiation patterns, inexplicable RF feedback in the radio shack, unexplained high noise floors, and RFI complaints from neighbors—stems from improper interfacing between balanced and unbalanced circuits. Resolving these challenges requires mastering the physics of baluns (balanced-to-unbalanced transformers), ununs (unbalanced-to-unbalanced transformers), and common-mode current chokes .
Balanced vs. Unbalanced Transmission Systems
To understand why baluns are necessary, we must examine the electromagnetic field geometry of balanced versus unbalanced lines. Balanced System (e.g., Open-Wire Ladder Line) Unbalanced System (Coaxial Cable)
- +I ------------------------------> +I_center -------------------->
- [ Dielectric Core ]
- I <------------------------------ -I_inner <===================
- (Equal currents, opposite phase, (Shield Inside Surface)
- identical impedance to ground) +I_outer ~~~~~~~~~~~~~~~~~~~>
- (Shield Outside - Common Mode!)
- 1. Balanced Systems (Dipoles, Loops, Open-Wire Feeders)
A balanced system is electrically symmetrical with respect to ground. In a center-fed half-wave dipole or a two-wire open ladder line:
Both conductors exhibit identical physical dimensions and identical stray capacitance to surrounding earth and structures.
The alternating voltages on the two conductors are equal in magnitude and 180 ∘ 180^\circ 18 0 ∘ out of phase ( V 1 = − V 2 V_1 = -V_2 V 1 = − V 2 ).
The RF currents flowing along the conductors are equal in magnitude and flow in opposite directions ( I 1 = − I 2 I_1 = -I_2 I 1 = − I 2 ).
Because the conductors carry equal and opposite currents in close proximity, their external radiated fields cancel completely along the transmission line, preventing the feedline from radiating.
2. Unbalanced Systems (Coaxial Cable)
A coaxial cable is an asymmetrical, unbalanced transmission line:
The central conductor is entirely enclosed within a cylindrical conducting shield.
The shield is maintained at ground potential at the transceiver chassis.
Forward signal current flows along the center conductor ( I center I_{\text{center}} I center ).
The Skin Effect and the Three-Conductor Reality of Coaxial Cable
At radio frequencies ( > 1.8 MHz > 1.8\text{ MHz} > 1.8 MHz ), electrical currents do not penetrate uniformly through a conductor. The skin depth ( δ \delta δ ) in copper is defined by: δ = ρ π f μ \delta = \sqrt{\frac{\rho}{\pi f \mu}} δ = π f μ ρ
where ρ \rho ρ is copper resistivity ( 1.724 × 10 − 8 Ω ⋅ m 1.724 \times 10^{-8}\ \Omega\cdot\text{m} 1.724 × 1 0 − 8 Ω ⋅ m ), f f f is operating frequency, and μ \mu μ is permeability ( 4 π × 10 − 7 H/m 4\pi \times 10^{-7}\ \text{H/m} 4 π × 1 0 − 7 H/m ). At 14 MHz 14\text{ MHz} 14 MHz , the skin depth is approximately 17 μ m 17\ \mu\text{m} 17 μ m ( 0.017 mm 0.017\text{ mm} 0.017 mm ). Because standard coaxial braid is several skin depths thick:
The Inner Shield Surface: Carries the return current ( I inner I_{\text{inner}} I inner ) for the center conductor. Guided by electromagnetic boundary conditions within the dielectric, I inner I_{\text{inner}} I inner is strictly equal and opposite to I center I_{\text{center}} I center ( I inner = − I center I_{\text{inner}} = -I_{\text{center}} I inner = − I center ). The net magnetic field outside the inner shield surface is zero.
The Outer Shield Surface: Acts as a separate RF-current path, largely isolated from the inside by skin effect; real shielding still permits some coupling. Current flowing on the outside of the shield is termed common-mode current ( I cm I_{\text{cm}} I cm ). It flows unimpeded along the exterior of the cable jacket and radiates into free space exactly like an unguided wire antenna.
Direct Coax Connection and the Common-Mode Path
When a coaxial cable is connected directly to a center-fed dipole without an isolation device:
The center conductor connects to antenna leg A.
The shield connects to antenna leg B. Coax center ----------------o A ---- Antenna leg A
- Coax shield interior -------o B ---- Antenna leg B
- |
- Shield exterior <-----------+
- Possible common-mode path along cable exterior
A and B are separate feed terminals.
Desired differential current returns inside the shield.
At this junction, antenna leg B connects directly to two parallel paths:
The inside surface of the shield (guided return path back to the generator).
The outside surface of the shield (path to ground via the cable exterior).
Antenna asymmetry or the feedline's coupling to its surroundings can drive current on the shield exterior. Its magnitude depends on the impedance of the complete common-mode return path.
Define I A I_A I A and I B I_B I B as phasor currents directed away from the feed terminals into the two legs , and I cm I_{\text{cm}} I cm as the exterior current directed away from the feedpoint. Current balance gives I cm = − ( I A + I B ) I_{\text{cm}}=-(I_A+I_B) I cm = − ( I A + I B ) . For balanced differential operation, I A = − I B I_A=-I_B I A = − I B and the exterior current is zero. A finite exterior current indicates imbalance.
Possible Consequences of Common-Mode Current
Pattern Changes: The feedline exterior can radiate, filling nulls or changing lobes and front-to-back ratio. There is no universal direction or amount of takeoff-angle change.
RF in the Shack: Exterior current can reach chassis and connected cables, causing audio distortion, computer-interface faults or RF burns.
Receive Noise: By reciprocity, noise coupled onto the exterior can reach the antenna feedpoint and receiver. The noise change depends on local sources and coupling; it is not a fixed decibel increase.
Balun Topologies: Voltage Baluns vs. Current Baluns
A balun interfaces a balanced antenna or line with an unbalanced feed. Voltage and current baluns impose different ideal conditions; practical suppression depends on their construction and the connected load. Voltage balun: ideal V_A = -V_B relative to the reference.
Unequal impedances to the reference can give unequal leg currents.
Current balun: ideal I_A = -I_B.
A practical choke adds finite impedance to the common-mode path.
Differential flux cancels ideally; common-mode flux remains.
1. Voltage Baluns (Ruthroff Type)
A voltage balun is wound as an autotransformer or trifilar transformer on a toroidal core. Its winding topology forces the potentials at the two balanced output terminals to be equal and opposite relative to ground: V 1 = − V 2 V_1 = -V_2 V 1 = − V 2
Voltage Balance and Current Imbalance
The antenna legs may have different impedances to their surroundings. In a simplified leg-to-reference model, I A = V A Z A , I B = V B Z B . I_A=\frac{V_A}{Z_A},\qquad I_B=\frac{V_B}{Z_B}. I A = Z A V A , I B = Z B V B .
Even with V A = − V B V_A=-V_B V A = − V B , unequal Z A Z_A Z A and Z B Z_B Z B generally give I A + I B ≠ 0 I_A+I_B\ne0 I A + I B = 0 . Thus voltage balance alone does not ensure current balance or suppress exterior shield current. Reactance alone does not imply imbalance: both complex impedances and their symmetry matter.
A voltage transformer has core excitation set by its winding voltage, frequency, turns and core properties. Excess flux or loss can cause distortion and heating. Neither load imbalance alone nor a universal 400 W 400\text{ W} 400 W threshold determines saturation.
2. Current Baluns (Guanella Transmission Line Type)
A current balun (first developed by G. Guanella in 1944) treats the winding as a transmission line (a bifilar pair or miniature coaxial cable) wound through one or more high-permeability ferrite toroids.
Operational Principle: The Common-Mode Choke
A current balun adds impedance to the common-mode path while allowing the wanted differential signal through its transmission line:
Differential Mode: Equal and opposite conductor currents ideally produce cancelling flux in the surrounding core. The line still has conductor/dielectric loss and voltage/current limits.
Common Mode: Exterior shield current, or same-direction current on a wire pair, produces core flux. It encounters a complex choking impedance Z cm = R cm + j X cm Z_{\text{cm}}=R_{\text{cm}}+jX_{\text{cm}} Z cm = R cm + j X cm , which depends on frequency and construction.
High common-mode impedance reduces the imbalance current. In the ideal limit, I A = − I B . I_A=-I_B. I A = − I B .
A real choke has finite impedance, so residual common-mode current can remain. Its resistive component dissipates I cm 2 R cm I_{\text{cm}}^2R_{\text{cm}} I cm 2 R cm ; excessive excitation can overheat the core. Current baluns are useful for maintaining current balance with asymmetric antenna surroundings, but their suppression and power capability must be assessed for the intended bands and duty cycle.
- Specific Balun Configurations and Impedance Ratios
- 1:1 Current Balun (Choke Balun)
A 1:1 current balun provides no intended differential impedance transformation. It can use a bifilar line or coax wound through ferrite cores and is commonly placed at a dipole, inverted-V or Yagi feedpoint. Select the material, dimensions and winding from measured choking-impedance data for the required bands. A turn count or material name alone does not establish full-HF coverage or a fixed decibel reduction.
4:1 Current Balun (Guanella Design)
A 4:1 Guanella balun transforms a 50 Ω 50\ \Omega 50 Ω unbalanced coaxial input to a 200 Ω 200\ \Omega 200 Ω balanced output. It is constructed from two identical 1:1 Guanella transformers :
The inputs of the two transmission lines are connected in parallel ( 50 Ω 50\ \Omega 50 Ω system input).
The outputs of the two transmission lines are connected in series ( 200 Ω 200\ \Omega 200 Ω balanced output).
Because ( 2 × V ) 2 / R (2 \times V)^2 / R ( 2 × V ) 2 / R yields an impedance transformation of 1 : 4 1:4 1 : 4 , it provides a true wideband 4 : 1 4:1 4 : 1 step-up.
Applications: Balanced antennas whose measured feed impedance is suitable for transformation to the coax impedance. A 200 Ω 200\ \Omega 200 Ω resistive load transforms to 50 Ω 50\ \Omega 50 Ω with an ideal 4:1 unit; height, geometry and surroundings determine the actual antenna impedance.
- RF Connection Terminals
- Input positive Line 1 input positive and line 2 input positive
- Input return Line 1 input negative and line 2 input negative
- Series output junction Line 1 output negative to line 2 output positive
- Balanced output A Line 1 output positive
- Balanced output B Line 2 output negative
Use the correct winding polarity and adequate, reasonably matched common-mode impedances in both line sections. These are RF transmission-line-transformer connections, not two isolated ordinary transformers.
Ununs: Unbalanced-to-Unbalanced Transformers
An unun transforms impedance between unbalanced ports. An end-fed antenna also needs an RF return, such as a counterpoise or another defined return path. An impedance-transforming unun alone does not necessarily suppress common-mode current on the coax.
9:1 Unun (Impedance Step-Down for End-Fed Wires)
A 9:1 unun utilizes a trifilar winding connected as an autotransformer on a ferrite toroid:
Turns Ratio: The primary winding has N N N turns, and the total winding has 3 N 3N 3 N turns (turns ratio 1 : 3 1:3 1 : 3 ).
Impedance Ratio: Impedance scales as the square of the turns ratio: Z secondary Z primary = ( N sec N pri ) 2 = ( 3 1 ) 2 = 9 : 1 \frac{Z_{\text{secondary}}}{Z_{\text{primary}}} = \left(\frac{N_{\text{sec}}}{N_{\text{pri}}}\right)^2 = \left(\frac{3}{1}\right)^2 = 9:1 Z primary Z secondary = ( N pri N sec ) 2 = ( 1 3 ) 2 = 9 : 1
Application: End-fed wire antennas can present high, complex impedances that change with frequency, wire length, height and the RF return path. For a specified 450 + j 0 Ω 450+j0\ \Omega 450 + j 0 Ω load at one frequency, an ideal 9:1 step-down gives 50 + j 0 Ω 50+j0\ \Omega 50 + j 0 Ω . More generally, it gives Z in = Z load / 9 Z_{\text{in}}=Z_{\text{load}}/9 Z in = Z load /9 : it scales reactance as well as resistance rather than cancelling it. Measure the installed system and check the tuner's actual matching range.
4:1 Unun
A 4:1 unun uses a bifilar autotransformer to match 50 Ω 50\ \Omega 50 Ω coax to 12.5 Ω 12.5\ \Omega 12.5 Ω (stepping up low-impedance vertical mobile whips) or to match 50 Ω 50\ \Omega 50 Ω coax to 200 Ω 200\ \Omega 200 Ω unbalanced feeds (such as high-impedance ground planes).
Coaxial Common-Mode Chokes: Coiled Coax vs. Ferrite Sleeves
Amateur operators frequently attempt to suppress common-mode shield currents using one of two methods: Air-core coiled coax Ferrite common-mode choke
- Inductance + stray capacitance Complex permeability + stray C
- Frequency-selective impedance Resistive loss can broaden response
Both have self-resonances; check impedance over the required bands.
1. Air-Core Coiled Coax ("Ugly Balun")
Coiling coax adds common-mode inductance, while inter-turn capacitance creates self-resonance. The impedance is inductive below a simple parallel resonance, high near resonance and capacitive above it. Such chokes are often more frequency selective than a suitably designed resistive ferrite choke. Useful coverage depends on the actual coil and surrounding common-mode circuit; it is not fixed to exactly one amateur band.
2. Ferrite Core Chokes (The W2DU and Toroidal Chokes)
Toroidal Choke: Pass the complete transmission line through ferrite cores, often with multiple turns.
Bead Choke: Pass the coax through a series of ferrite sleeves.
Ferrite has complex permeability, μ = μ ′ − j μ ′ ′ \mu=\mu'-j\mu'' μ = μ ′ − j μ ′′ . Its loss component can produce a useful resistive choking impedance and damp resonance. Ferrite chokes still have parasitic capacitance and self-resonances. Their impedance curves depend on mix, dimensions and winding; more than one choke may be needed for wide coverage. A high resistive component is often useful because it does not cancel a reactive return path. Actual current reduction depends on the choke and the complete common-mode loop.
Step-by-Step Worked Common-Mode Choke Calculation
An amateur transmitter generates V 0 = 141.4 V RMS V_0 = 141.4\text{ V RMS} V 0 = 141.4 V RMS ( 400 W 400\text{ W} 400 W into 50 Ω 50\ \Omega 50 Ω ). Due to antenna installation asymmetry, a common-mode RF potential of V cm = 100 V RMS V_{\text{cm}} = 100\text{ V RMS} V cm = 100 V RMS is induced at the feedpoint between the shield exterior and local earth ground. The stray ground-return path impedance along the outside of the coax shield is measured as Z path = 50 + j 20 Ω Z_{\text{path}} = 50 + j20\ \Omega Z path = 50 + j 20 Ω ( ∣ Z ∣ ≈ 53.9 Ω |Z| \approx 53.9\ \Omega ∣ Z ∣ ≈ 53.9 Ω ).
Step 1: Calculate Common-Mode Current WITHOUT a Choke I cm = V cm Z path = 100 V 53.9 Ω ≈ 1.855 A RMS I_{\text{cm}} = \frac{V_{\text{cm}}}{Z_{\text{path}}} = \frac{100\text{ V}}{53.9\ \Omega} \approx 1.855\text{ A RMS} I cm = Z path V cm = 53.9 Ω 100 V ≈ 1.855 A RMS
This large exterior current could cause substantial unwanted radiation, interference or RF burns, depending on its distribution and the surrounding installation.
Step 2: Insert a High-Performance Guanella Current Choke
A 1:1 Guanella ferrite choke presenting a purely resistive common-mode choking impedance of Z choke = 4000 Ω Z_{\text{choke}} = 4000\ \Omega Z choke = 4000 Ω is installed directly at the feedpoint.
The total common-mode loop impedance becomes: Z total = Z choke + Z path = ( 4000 + 50 ) + j 20 = 4050 + j 20 Ω Z_{\text{total}} = Z_{\text{choke}} + Z_{\text{path}} = (4000 + 50) + j20 = 4050 + j20\ \Omega Z total = Z choke + Z path = ( 4000 + 50 ) + j 20 = 4050 + j 20 Ω ∣ Z total ∣ = 4050 2 + 20 2 ≈ 4050.05 Ω |Z_{\text{total}}| = \sqrt{4050^2 + 20^2} \approx 4050.05\ \Omega ∣ Z total ∣ = 405 0 2 + 2 0 2 ≈ 4050.05 Ω
Step 3: Calculate Suppressed Common-Mode Current I cm, suppressed = 100 V 4050 Ω ≈ 0.0247 A RMS = 24.7 mA RMS I_{\text{cm, suppressed}} = \frac{100\text{ V}}{4050\ \Omega} \approx 0.0247\text{ A RMS} = 24.7\text{ mA RMS} I cm, suppressed = 4050 Ω 100 V ≈ 0.0247 A RMS = 24.7 mA RMS
Step 4: Calculate Attenuation in Decibels Atten (dB) = 20 log 10 ( I unsuppressed I suppressed ) = 20 log 10 ( 1.855 0.0247 ) = 20 log 10 ( 75.1 ) ≈ 37.5 dB \text{Atten (dB)} = 20 \log_{10}\left(\frac{I_{\text{unsuppressed}}}{I_{\text{suppressed}}}\right) = 20 \log_{10}\left(\frac{1.855}{0.0247}\right) = 20 \log_{10}(75.1) \approx 37.5\text{ dB} Atten (dB) = 20 lo g 10 ( I suppressed I unsuppressed ) = 20 lo g 10 ( 0.0247 1.855 ) = 20 lo g 10 ( 75.1 ) ≈ 37.5 dB
With the assumed fixed 100 V RMS 100\text{ V RMS} 100 V RMS common-mode source and unchanged return path, the calculated reduction is 37.5 dB 37.5\text{ dB} 37.5 dB and the remaining current is 24.7 mA RMS 24.7\text{ mA RMS} 24.7 mA RMS . This does not guarantee elimination of RFI or a particular receive-noise improvement. The choke also dissipates I 2 R ≈ ( 0.0247 ) 2 × 4000 = 2.44 W I^2R\approx(0.0247)^2\times4000=2.44\text{ W} I 2 R ≈ ( 0.0247 ) 2 × 4000 = 2.44 W from this common-mode current, which its thermal design must accommodate.
Comparison Table: Balun and Unun Classifications
Device Type Topology / Core Type Ratio Forced Condition Core Flux Status Primary Application
1:1 Current Balun Guanella transmission-line choke 1 : 1 1:1 1 : 1 Encourages I A = − I B I_A=-I_B I A = − I B Differential flux cancels ideally; common-mode flux/heating remain Dipoles, Yagis and loops
4:1 Current Balun Two lines, parallel in/series out 4 : 1 4:1 4 : 1 Current balance and impedance transformation Same common-mode and thermal limits Suitable balanced loads near 200 Ω 200\ \Omega 200 Ω
4:1 Voltage Balun Voltage-transformer winding 4 : 1 4:1 4 : 1 Ideal V A = − V B V_A=-V_B V A = − V B Excitation depends on voltage, frequency, turns and core Loads where voltage balance is appropriate
9:1 Unun Unbalanced autotransformer 9 : 1 9:1 9 : 1 Voltage and impedance transformation Transformer excitation and loss must be rated Suitable unbalanced high-impedance loads
Air-Core Choke Coiled coax, no ferrite 1 : 1 1:1 1 : 1 Frequency-dependent common-mode impedance No magnetic-core loss; cable loss remains Bands covered by its measured impedance response