Study guide

10.2 Quarter-Wave Verticals, Ground Systems, and Radiation Efficiency

ACMA Amateur Radio Advanced Recognition Certificate - Theory Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: DC Theory, Circuit Laws & Passive Components

1.1 DC Circuit Analysis, Ohm's Law, and Kirchhoff's Laws 1.2 AC Fundamentals, Sine Waves, Peak, RMS, and Phase Relationships 1.3 Inductance, Capacitance, Reactance, and Time Constants

2 Chapter 2: Impedance, Resonance & Passive Filters

2.1 Complex Impedance, Phasors, and AC Circuit Analysis 2.2 Series and Parallel LC Resonance and Q Factor 2.3 Passive Filters, Cutoff Frequency, and Attenuator Pads

3 Chapter 3: Semiconductor Devices & Power Supplies

3.1 Semiconductor Diodes, Zener Regulators, and Rectifier Circuits 3.2 Bipolar Junction Transistors, FETs, and Operational Amplifiers 3.3 Thermionic Valves (Vacuum Tubes) and High-Power Linear Amplifiers 3.4 DC Power Supplies, Filter Networks, and Voltage Regulators

4 Chapter 4: Oscillators & Frequency Synthesis

4.1 RF Oscillators, LC Tank Topologies, and Frequency Stability 4.2 Phase-Locked Loops (PLLs) and Frequency Synthesisers 4.3 Direct Digital Synthesis (DDS), SDR Architectures, and Digital Filter Topologies

5 Chapter 5: RF Amplifiers & Linearity

5.1 Classes of Amplification, Conduction Angles, and Operating Efficiency 5.2 RF Power Amplifiers, Push-Pull Topologies, and Output Matching 5.3 Amplifier Stability, Neutralisation, and Intermodulation Distortion

6 Chapter 6: Modulation & Demodulation

6.1 Amplitude Modulation, Double Sideband, and Single Sideband (SSB) 6.2 Frequency Modulation, Phase Modulation, and FM Detectors 6.3 Digital Modulation Modes, Spectral Efficiency, and Weak-Signal Protocols

7 Chapter 7: Transmitters, Mixers & Receivers

7.1 RF Mixers, Frequency Translation, and Intermodulation 7.2 Transmitter Architectures, CW Keying, and Output Filtering 7.3 Superheterodyne Receiver Design, IF Selection, and Image Rejection 7.4 Receiver Performance Specifications, Dynamic Range, and Selectivity

8 Chapter 8: Transmission Lines & Waveguides

8.1 Transmission Line Characteristics, Impedance, and Velocity Factor 8.2 Standing Waves, Reflection Coefficient, SWR, and Return Loss 8.3 Resonant Line Sections, Quarter-Wave Transformers, and Stubs

9 Chapter 9: Impedance Matching & Baluns

9.1 Lumped-Element Matching Networks and Antenna Tuning Units 9.2 Baluns, Ununs, and Common-Mode Current Choking 9.3 Feedline Losses, High-SWR Stress, and Coaxial Installation Practice

10 Chapter 10: Practical Antennas & Arrays

10.1 Resonant Dipoles, Inverted-Vs, and Multiband Wire Antennas 10.2 Quarter-Wave Verticals, Ground Systems, and Radiation Efficiency 10.3 Parasitic Arrays, Yagi-Uda Antennas, and Quad Arrays 10.4 Antenna Gain, Aperture Antennas & Horns, ERP/EIRP, Radiation Patterns

11 Chapter 11: Radio Wave Propagation & Ionospheric Mechanics

11.1 Electromagnetic Wave Fundamentals, Polarisation, and Ground Waves 11.2 The Ionosphere, Solar Radiation, and Solar Cycles 11.3 Critical Frequency, Maximum Usable Frequency, and HF Propagation Paths

12 Chapter 12: VHF/UHF Propagation & Space Communications

12.1 Line-of-Sight, Tropospheric Ducting, and Diffraction 12.2 Sporadic-E, Auroral Scatter, and Trans-Equatorial Propagation 12.3 Amateur Satellites, Doppler Shift, and Earth-Moon-Earth (EME)

13 Chapter 13: Test Equipment & RF Measurements

13.1 Decibels, Power Ratios, and Cascaded Stage Calculations 13.2 RF Power Meters, Directional Couplers, and Dummy Loads 13.3 Multirange Meters, Waveform Diagnostics, Oscilloscopes, and Frequency Counters

14 Chapter 14: Advanced RF Analysis & Diagnostics

14.1 Spectrum Analyser Architecture, Operation, and Spectral Purity 14.2 Antenna Analysers, Vector Network Analysers, and Smith Charts 14.3 Calibrated Signal Generators, Grid Dip Meters, and Component Testing

15 Chapter 15: Electromagnetic Compatibility & Interference

15.1 Sources of Interference, Coupling Mechanisms, and Audio Rectification 15.2 Receiver Susceptibility, Desensitisation, and Front-End Intermodulation 15.3 Practical RFI Suppression, Filter Design, and Bonding Techniques

16 Chapter 16: Electrical, RF & Station Safety

16.1 Biological Effects of RF Energy and ARPANSA Exposure Standards 16.2 Safe Separation Distances, Power Density, and Duty Cycles 16.3 Station Electrical Safety, Battery Hazards, and Safe Headphone Use 16.4 Mast and Tower Construction, Power Line Clearance, and Lightning Protection

10.2 Quarter-Wave Verticals, Ground Systems, and Radiation Efficiency

Key Takeaways Explain This Topic AI

A quarter-wave ( λ / 4 \lambda/4 λ /4 ) vertical monopole relies on conducting earth or an artificial counterpoise to form an image antenna, establishing a current antinode ( I max I_{\text{max}} I max ​ ) at the base and a theoretical radiation resistance of 36.8 Ω 36.8\ \Omega 36.8 Ω over perfect ground.

Vertical monopoles can provide useful low-angle radiation for long-distance skywave paths. Actual elevation patterns depend on ground and surroundings; low horizontal dipoles can instead be useful for high-angle regional coverage.

Feedpoint input resistance is the algebraic sum of radiation resistance and loss resistance ( R in = R r + R g R_{\text{in}} = R_r + R_g R in ​ = R r ​ + R g ​ ); radiation efficiency is defined as η = R r R r + R g × 100 % \eta = \frac{R_r}{R_r + R_g} \times 100\% η = R r ​ + R g ​ R r ​ ​ × 100% .

Buried radials reduce near-field ground loss; more wires generally give diminishing improvements. A few well-arranged elevated radials can also be effective, but height, tuning, symmetry, surroundings and soil affect both systems.

For an electrically short monopole with triangular current over a perfect ground plane, R r ≈ 40 π 2 ( h / λ ) 2 R_r\approx40\pi^2(h/\lambda)^2 R r ​ ≈ 40 π 2 ( h / λ ) 2 . Top loading can make current more uniform and improve efficiency; actual coil and ground losses still matter.

Last updated: November 2026

10.2 Quarter-Wave Verticals, Ground Systems, and Radiation Efficiency

While horizontal wire antennas are staple performers for regional and transcontinental communications, long-distance intercontinental DX on the High Frequency (HF) bands requires radiation concentrated at low vertical takeoff angles. The quarter-wave ( λ / 4 \lambda/4 λ /4 ) vertical monopole is the preeminent omnidirectional antenna for achieving low-angle radiation without requiring astronomical tower heights. However, because a vertical monopole is an unbalanced system operating against the earth, its radiation efficiency, input impedance, and overall performance are governed directly by the quality of its ground return system.

The Quarter-Wave Monopole and Image Antenna Theory

A quarter-wave vertical antenna consists of a straight vertical radiating element of electrical length λ / 4 \lambda/4 λ /4 , fed at its base against an underlying conductive plane. Quarter-Wave Vertical Monopole

  • Open Top: Voltage Antinode (V_max), Current Zero (I = 0)
  • |
  • |
  • | Physical Radiator
  • | Length h ≈ λ/4
  • |
  • |
  • Base Feed: Current Maximum; Finite RF Feed Voltage
  • ==================================o==================================
  • ///// Conductive Ground Plane ///////////////////////////////////////
  • : (Image Antenna)
  • : Forms lower half of
  • : virtual half-wave dipole

:

:

The Image Antenna Principle

The physical operation of a vertical monopole is explained through the Method of Images in electrodynamics:

Boundary conditions at the surface of an infinite, perfectly conducting planar ground require that the tangential component of the electric field must equal zero ( E tan = 0 E_{\text{tan}} = 0 E tan ​ = 0 ).

This boundary condition is mathematically identical to replacing the conducting ground plane with a virtual image antenna positioned beneath the surface.

Because the radiator is oriented perpendicularly to the ground plane, the vertical current in the real monopole induces an in-phase vertical current in the subterranean image.

Together, the real λ / 4 \lambda/4 λ /4 vertical radiator and its virtual λ / 4 \lambda/4 λ /4 image synthesize a complete half-wave ( λ / 2 \lambda/2 λ /2 ) vertical dipole operating in free space!

Current, Voltage, and Theoretical Input Resistance

The standing wave distribution on a quarter-wave monopole corresponds exactly to one half of a center-fed dipole:

Base Feedpoint: Current is maximum and voltage is relatively low compared with the open top. The driven terminal voltage is finite: V feed = I base Z in V_{\text{feed}}=I_{\text{base}}Z_{\text{in}} V feed ​ = I base ​ Z in ​ .

Open Top: Forms a voltage antinode ( V max V_{\text{max}} V max ​ ) and a current node ( I = 0 I = 0 I = 0 ).

Over an infinite, perfectly conducting ground plane, the monopole radiates only into the upper hemisphere ( 2 π 2\pi 2 π steradians), whereas a dipole radiates into the full sphere ( 4 π 4\pi 4 π steradians). For an identical feedpoint current I base I_{\text{base}} I base ​ , the total power radiated by the monopole is exactly half that of a dipole in free space: P monopole = 1 2 P dipole = 1 2 I base 2 R dipole = I base 2 ( R dipole 2 ) P_{\text{monopole}} = \frac{1}{2} P_{\text{dipole}} = \frac{1}{2} I_{\text{base}}^2 R_{\text{dipole}} = I_{\text{base}}^2 \left(\frac{R_{\text{dipole}}}{2}\right) P monopole ​ = 2 1 ​ P dipole ​ = 2 1 ​ I base 2 ​ R dipole ​ = I base 2 ​ ( 2 R dipole ​ ​ )

Consequently, the theoretical radiation resistance of a resonant quarter-wave vertical over perfect ground is exactly half the radiation resistance of a resonant half-wave dipole ( 73.13 Ω / 2 73.13\ \Omega / 2 73.13 Ω/2 ): R r = 36.6 Ω ≈ 36.8 Ω R_r = 36.6\ \Omega \approx 36.8\ \Omega R r ​ = 36.6 Ω ≈ 36.8 Ω

Elevation Pattern and DX

An ideal quarter-wave monopole over an infinite perfect conductor is omnidirectional in azimuth, has maximum radiation toward the horizon and a null along its vertical axis. Real ground loss and reflection modify this pattern, including its low-angle strength.

Low-angle radiation is often useful for long single-hop skywave paths, so a vertical with an effective ground system can be a practical DX antenna. It is not automatically superior on every path. Horizontal-dipole height and terrain also determine elevation lobes, while a low dipole can be advantageous for high-angle regional communication.

Ground Systems and Radiation Efficiency

While the theoretical radiation resistance over perfect ground is 36.8 Ω 36.8\ \Omega 36.8 Ω , real earth is far from a perfect conductor. Soil consists of minerals, moisture, and organic material exhibiting poor electrical conductivity (typically σ ≈ 10 − 4 S/m \sigma \approx 10^{-4}\text{ S/m} σ ≈ 1 0 − 4 S/m for dry sand to 10 − 2 S/m 10^{-2}\text{ S/m} 1 0 − 2 S/m for rich loam) and dielectric permittivity ( ε r ≈ 5 − 15 \varepsilon_r \approx 5 - 15 ε r ​ ≈ 5 − 15 ). Earth Return Currents

  • Vertical Radiator
  • |
  • |
  • | Displacement Currents (E-Field Lines)
  • | ) ) ) ) )
  • | ( ( ( ( (
  • ====================================o====================================
  • <======= (J_return) ======> Base <====== (J_return) =======>

High Current Concentration in Lossy Earth -> Severe I^2 * R_g Dissipation!

The Closed Electrical Circuit of an Antenna

Charge-current continuity involves both conduction current and the changing electric field. The displacement-current density is J D = ∂ D / ∂ t \mathbf J_D=\partial\mathbf D/\partial t J D ​ = ∂ D / ∂ t (or ε ∂ E / ∂ t \varepsilon\,\partial\mathbf E/\partial t ε ∂ E / ∂ t in a uniform linear dielectric), and current through a surface is I D = ∫ J D ⋅ d A I_D=\int\mathbf J_D\cdot d\mathbf A I D ​ = ∫ J D ​ ⋅ d A . In a practical monopole, soil and the radial system participate in the RF return. This does not mean radiated energy returns to the transmitter: radiation carries energy away. The equivalent input resistance is: R in = R r + R g + R c R_{\text{in}} = R_r + R_g + R_c R in ​ = R r ​ + R g ​ + R c ​

where:

R r R_r R r ​ is the radiation resistance (the virtual resistance that accounts for energy genuinely launched into space as radio waves).

R g R_g R g ​ is the ground loss resistance (ohmic dissipation caused by return currents flowing through lossy soil).

R c R_c R c ​ is the conductor resistance (RF ohmic resistance of the aluminum tubing, loading coils, and connecting leads due to skin effect).

Radiation Efficiency Formulation

The radiation efficiency ( η \eta η ) of an antenna is the fraction of net power accepted at its feedpoint that is radiated, rather than dissipated in antenna and ground losses: η = P radiated P input × 100 % = I base 2 R r I base 2 ( R r + R g + R c ) × 100 % = R r R r + R g + R c × 100 % \eta = \frac{P_{\text{radiated}}}{P_{\text{input}}} \times 100\% = \frac{I_{\text{base}}^2 R_r}{I_{\text{base}}^2 (R_r + R_g + R_c)} \times 100\% = \frac{R_r}{R_r + R_g + R_c} \times 100\% η = P input ​ P radiated ​ ​ × 100% = I base 2 ​ ( R r ​ + R g ​ + R c ​ ) I base 2 ​ R r ​ ​ × 100% = R r ​ + R g ​ + R c ​ R r ​ ​ × 100%

Because R c R_c R c ​ is usually small ( < 0.5 Ω < 0.5\ \Omega < 0.5 Ω ) in full-size aluminum radiators, efficiency is governed almost entirely by the ratio of radiation resistance ( R r R_r R r ​ ) to ground resistance ( R g R_g R g ​ ): η ≈ R r R r + R g × 100 % \eta \approx \frac{R_r}{R_r + R_g} \times 100\% η ≈ R r ​ + R g ​ R r ​ ​ × 100%

Warning

If an amateur installs a quarter-wave vertical ( R r = 36.8 Ω R_r = 36.8\ \Omega R r ​ = 36.8 Ω ) over poor soil with only a single ground rod, the ground loss resistance ( R g R_g R g ​ ) typically exceeds 35 Ω 35\ \Omega 35 Ω to 50 Ω 50\ \Omega 50 Ω ! In this scenario: η = 36.8 36.8 + 45 × 100 % = 36.8 81.8 × 100 % ≈ 45 % \eta = \frac{36.8}{36.8 + 45} \times 100\% = \frac{36.8}{81.8} \times 100\% \approx 45\% η = 36.8 + 45 36.8 ​ × 100% = 81.8 36.8 ​ × 100% ≈ 45%

More than half of the transmitter's output power is permanently lost heating the earth around the base of the mast!

Current Concentration and Radial Density

RF return currents and electric fields can produce substantial loss near the antenna base. Their distribution depends on the radiator, soil and ground-system geometry. Radial wires provide lower-loss conducting paths and reduce these near-field losses; one universal 1/r law does not describe every radial installation. Buried Radial Screen Layout

  • / | \
  • / | \
  • / | \
  • / | \
  • +-----------o-----------+
  • / \ Base / \
  • / \ / \
  • / \ / \
  • / \ / \
  • \ /
  • (30 to 120 Buried Radials)
  • Buried Radial Systems

A classic buried ground system consists of bare copper wires laid in a radial spoke pattern centered at the antenna base:

Wire Placement: Radials are buried shallowly—typically 2 to 10 cm 2\text{ to }10\text{ cm} 2 to 10 cm below the surface—merely to prevent mechanical damage from lawn mowers and turf aeration. Because skin depth in conductive soil at HF is on the order of meters, shallow burial intercepts displacement currents at the surface.

Adding radials generally reduces ground loss, with diminishing improvement as the system becomes denser. Radial count alone does not specify a resistance or efficiency: soil conductivity, frequency, wire length, burial and antenna dimensions also matter.

Ground-system feature Practical effect

Ground rod alone May leave large RF ground loss; a protective/lightning earth is not by itself an efficient RF radial system

  • A few surface or buried radials Can improve efficiency, but performance is sensitive to the installation
  • More radials over the available area Usually reduce near-field loss and sensitivity to individual wires

Dense radial screen Further improvement becomes progressively smaller; assess the useful return for the available wire and space

Tip

With a limited wire budget, many shorter radials are often more useful than a few long ones. The best number and length still depend on antenna height, soil and available area; this is a practical trade-off, not a universal mathematical optimum.

Elevated Resonant Radials

For suburban stations where laying 60 buried radials is impossible, elevated resonant radials provide an extraordinarily efficient alternative. Elevated Resonant Ground Plane

  • Vertical Monopole
  • |
  • |
  • o Base Feedpoint
  • / | \
  • Elevated Radial 1 / | \ Elevated Radial 2
  • ===============================+ | +===============================
  • (Height h > 0.05λ above earth) | (Height h > 0.05λ above earth)
  • Support Post
  • ~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Lossy Earth Soil ~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Lower-Loss Return: Elevating the radial system can reduce lossy interaction with nearby soil, but does not eliminate the electric field in the ground.

Coupled Tuning: The radiator and radials interact with each other and earth. Their lengths, height and symmetry affect resonance and current distribution; separately cutting each wire to a nominal quarter wavelength does not establish zero loss.

Practical Performance: Three or four well-arranged elevated radials can perform well and, in suitable installations, compare with many ground-based radials. This result is not guaranteed by a fixed height or count. Check the actual geometry, balance and surroundings, and keep high-voltage radial ends inaccessible.

Shortened Vertical Antennas and Loading Methods

On the low HF bands ( 80 m 80\text{ m} 80 m and 160 m 160\text{ m} 160 m ), a full-size quarter-wave vertical requires physical heights of 20 meters 20\text{ meters} 20 meters ( 66 ft 66\text{ ft} 66 ft ) and 40 meters 40\text{ meters} 40 meters ( 130 ft 130\text{ ft} 130 ft ), respectively. Physical space and zoning restrictions often mandate electrically shortened radiators.

The Radiation Resistance Collapse

For an electrically short unloaded monopole ( h ≪ λ h\ll\lambda h ≪ λ ), the current is approximately triangular: maximum at the base and zero at the top. Over a perfect ground plane its base-referred radiation resistance is R r ≈ 40 π 2 ( h λ ) 2 Ω ≈ 395 ( h λ ) 2 Ω . R_r\approx40\pi^2\left(\frac{h}{\lambda}\right)^2\ \Omega

\approx395\left(\frac{h}{\lambda}\right)^2\ \Omega. R r ​ ≈ 40 π 2 ( λ h ​ ) 2 Ω ≈ 395 ( λ h ​ ) 2 Ω.

This short-antenna approximation does not accurately describe every height up to λ / 4 \lambda/4 λ /4 .

Furthermore, because the antenna is shorter than resonance, it exhibits intense capacitive reactance ( − j X C -jX_C − j X C ​ ) that must be canceled by inserting inductive reactance ( + j X L +jX_L + j X L ​ ) to re-establish resonance. Loading Methods for Shortened Verticals

  • Base Loading Center Loading Top-Hat Loading
  • | | === Capacitive Hat ===
  • | | |
  • | | |
  • | [#] Loading Coil |
  • | | |
  • [#] Loading Coil | |
  • | | |
  • =======o======= =======o======= =======o=======
  • (Full coil current) (Changes current profile) (Capacitive end loading)
  • Comparative Analysis of Loading Techniques
  • 1. Base Loading

Mechanism: A series loading inductor is inserted at the bottom feedpoint of the mast.

Loss: The base coil carries the full feed current and adds series resistance r coil = ∣ X L ∣ / Q 0 r_{\text{coil}}=|X_L|/Q_0 r coil ​ = ∣ X L ​ ∣/ Q 0 ​ . If radiation resistance is small, this resistance can consume a large fraction of accepted power. For example, R r = 1 Ω R_r=1\ \Omega R r ​ = 1 Ω and coil loss resistance 4 Ω 4\ \Omega 4 Ω , neglecting other losses, give η = 1 / ( 1 + 4 ) = 20 % \eta=1/(1+4)=20\% η = 1/ ( 1 + 4 ) = 20% . Actual loss is not fixed by the label “base loading.”

Advantages: Mechanically simple; easily accessible for motor-driven roller inductors or switched taps.

2. Center Loading

Mechanism: The loading inductor is positioned midway up the vertical radiator.

Advantages: Moving loading upward can maintain more current over the lower part of the radiator and increase effective radiating height. The coil current may be lower, but its required inductance and loss also change. Calculate the resulting current distribution and loss rather than assuming a universal twofold resistance increase or 3–5 dB efficiency gain.

Disadvantages: Heavy inductor aloft requires stronger mechanical mast guy wires.

3. Top Loading / Capacitive Hat

Mechanism: Large metallic horizontal spokes, wires, or a perimeter ring (a capacitive top hat ) are attached to the upper extremity of the mast.

Current Profile: A capacitive hat supports charge at the top and increases current in the upper vertical section. A sufficiently large hat can make the vertical current approach a uniform distribution.

Ideal Short-Radiator Limit: Relative to a triangular profile with effective height h / 2 h/2 h /2 , a uniform profile has effective height h h h . For the same base current, this doubles field strength and gives four times the radiation resistance: R r ≈ 160 π 2 ( h λ ) 2 Ω ≈ 1580 ( h λ ) 2 Ω . R_r\approx160\pi^2\left(\frac{h}{\lambda}\right)^2\ \Omega

\approx1580\left(\frac{h}{\lambda}\right)^2\ \Omega. R r ​ ≈ 160 π 2 ( λ h ​ ) 2 Ω ≈ 1580 ( λ h ​ ) 2 Ω.

Practical Trade-Off: A finite hat gives an intermediate current distribution and may still need a loading coil. Top loading can reduce required inductance and improve efficiency, but hat size, conductor/coil losses, ground and mechanical constraints determine the result.

Ground Plane (GP) Antennas with Drooping Radials

A Ground Plane (GP) antenna is an elevated vertical monopole where the ground plane is formed by 3 or 4 insulated elevated radials extending outward from the base of the center radiator. Drooping Ground Plane Antenna

  • Vertical Monopole
  • Length l ≈ λ/4
  • |
  • |
  • o Feedpoint Terminals
  • / \
  • 45° Droop / \ 45° Droop
  • =============/ \=============
  • Radial 1 Radial 2
  • (l ≈ λ/4) (l ≈ λ/4)

Drooping radials can move the input toward 50 ohms.

The 45° Droop Impedance Transformation

When the elevated radials are held strictly horizontal ( 90 ∘ 90^\circ 9 0 ∘ relative to the vertical radiator):

The antenna exhibits a radiation resistance of R in ≈ 36.6 Ω R_{\text{in}} \approx 36.6\ \Omega R in ​ ≈ 36.6 Ω .

Feeding a 36.6 Ω 36.6\ \Omega 36.6 Ω resistive load with standard 50 Ω 50\ \Omega 50 Ω coaxial cable produces a mismatch: SWR = 50 Ω 36.6 Ω ≈ 1.37 : 1 \text{SWR} = \frac{50\ \Omega}{36.6\ \Omega} \approx 1.37:1 SWR = 36.6 Ω 50 Ω ​ ≈ 1.37 : 1

Drooping the radials commonly raises feedpoint resistance toward a convenient coaxial match:

Important

A downward slope around 45 ∘ 45^\circ 4 5 ∘ is a useful starting geometry, giving an included angle around 135 ∘ 135^\circ 13 5 ∘ to the vertical radiator. The structure moves toward a vertical-dipole configuration and its resistance rises. Adjust dimensions and measure the complete input impedance; the angle alone does not guarantee exactly 50 + j 0 Ω 50+j0\ \Omega 50 + j 0 Ω .

Step-by-Step Worked Calculation: Ground Radial Efficiency Analysis

Compare two illustrative ground systems at 7.150 MHz 7.150\text{ MHz} 7.150 MHz with the same 100 W 100\text{ W} 100 W mean power accepted at the antenna feedpoint . Assume R r = 36.8 Ω R_r=36.8\ \Omega R r ​ = 36.8 Ω and R c = 0.2 Ω R_c=0.2\ \Omega R c ​ = 0.2 Ω in both cases:

Configuration A: Ground-rod installation, assumed equivalent R g = 38.0 Ω R_g=38.0\ \Omega R g ​ = 38.0 Ω .

Configuration B: A 60-radial ground system, assumed equivalent R g = 3.0 Ω R_g=3.0\ \Omega R g ​ = 3.0 Ω .

These resistance values are inputs to the example, not predictions from radial count or soil conductivity alone. Worked Efficiency Comparison

  • Configuration A (Single Ground Rod) Configuration B (60 Buried Radials)
  • ==================================== ===================================
  • R_r = 36.8 Ω R_r = 36.8 Ω
  • R_g = 38.0 Ω (Assumed Ground Loss) R_g = 3.0 Ω (Assumed Ground Loss)
  • R_c = 0.2 Ω R_c = 0.2 Ω
  • ----------------------------------- -----------------------------------
  • R_in = 75.0 Ω R_in = 40.0 Ω
  • Radiation Efficiency η ≈ 49.1% Radiation Efficiency η ≈ 92.0%
  • Step 1: Calculate Total Feedpoint Input Resistance ( R in R_{\text{in}} R in ​ )

Configuration A: R in(A) = R r + R g + R c = 36.8 Ω + 38.0 Ω + 0.2 Ω = 75.0 Ω R_{\text{in(A)}} = R_r + R_g + R_c = 36.8\ \Omega + 38.0\ \Omega + 0.2\ \Omega = 75.0\ \Omega R in(A) ​ = R r ​ + R g ​ + R c ​ = 36.8 Ω + 38.0 Ω + 0.2 Ω = 75.0 Ω

Configuration B: R in(B) = R r + R g + R c = 36.8 Ω + 3.0 Ω + 0.2 Ω = 40.0 Ω R_{\text{in(B)}} = R_r + R_g + R_c = 36.8\ \Omega + 3.0\ \Omega + 0.2\ \Omega = 40.0\ \Omega R in(B) ​ = R r ​ + R g ​ + R c ​ = 36.8 Ω + 3.0 Ω + 0.2 Ω = 40.0 Ω

Step 2: Calculate Radiation Efficiency ( η \eta η ) η = R r R in × 100 % \eta = \frac{R_r}{R_{\text{in}}} \times 100\% η = R in ​ R r ​ ​ × 100%

Configuration A: η A = 36.8 Ω 75.0 Ω × 100 % ≈ 49.07 % \eta_A = \frac{36.8\ \Omega}{75.0\ \Omega} \times 100\% \approx 49.07\% η A ​ = 75.0 Ω 36.8 Ω ​ × 100% ≈ 49.07%

Configuration B: η B = 36.8 Ω 40.0 Ω × 100 % = 92.00 % \eta_B = \frac{36.8\ \Omega}{40.0\ \Omega} \times 100\% = 92.00\% η B ​ = 40.0 Ω 36.8 Ω ​ × 100% = 92.00%

Step 3: Calculate Radiated Power vs. Ground Heat Loss

Mean accepted power is 100 W 100\text{ W} 100 W in both configurations. Feedline and matching losses are outside this example.

Configuration A: P rad(A) = 100 × 36.8 75 = 49.07 W P_{\text{rad(A)}}=100\times\frac{36.8}{75}=49.07\text{ W} P rad(A) ​ = 100 × 75 36.8 ​ = 49.07 W P loss(A) = 100 − 49.07 = 50.93 W P_{\text{loss(A)}}=100-49.07=50.93\text{ W} P loss(A) ​ = 100 − 49.07 = 50.93 W

Ground loss is 100 ( 38 / 75 ) = 50.67 W 100(38/75)=50.67\text{ W} 100 ( 38/75 ) = 50.67 W ; conductor loss is 100 ( 0.2 / 75 ) = 0.267 W 100(0.2/75)=0.267\text{ W} 100 ( 0.2/75 ) = 0.267 W .

Configuration B: P rad(B) = 100 × 36.8 40 = 92.00 W P_{\text{rad(B)}}=100\times\frac{36.8}{40}=92.00\text{ W} P rad(B) ​ = 100 × 40 36.8 ​ = 92.00 W P loss(B) = 100 − 92 = 8.00 W P_{\text{loss(B)}}=100-92=8.00\text{ W} P loss(B) ​ = 100 − 92 = 8.00 W

Ground loss is 100 ( 3 / 40 ) = 7.50 W 100(3/40)=7.50\text{ W} 100 ( 3/40 ) = 7.50 W ; conductor loss is 100 ( 0.2 / 40 ) = 0.50 W 100(0.2/40)=0.50\text{ W} 100 ( 0.2/40 ) = 0.50 W . PEP alone would not specify these mean heating powers.

Step 4: Quantify the Signal Advantage in Decibels

Comparing the radiated field strength: Δ dB = 10 log ⁡ 10 ( P rad(B) P rad(A) ) = 10 log ⁡ 10 ( 92 49.0667 ) ≈ + 2.73 dB \Delta\text{dB}=10\log_{10}\left(\frac{P_{\text{rad(B)}}}{P_{\text{rad(A)}}}\right)=10\log_{10}\left(\frac{92}{49.0667}\right)\approx+2.73\text{ dB} Δ dB = 10 lo g 10 ​ ( P rad(A) ​ P rad(B) ​ ​ ) = 10 lo g 10 ​ ( 49.0667 92 ​ ) ≈ + 2.73 dB

For unchanged radiation pattern, path and accepted power, the example gives about 2.73 dB 2.73\text{ dB} 2.73 dB more signal in a given direction. With the standard 6 dB 6\text{ dB} 6 dB per S-unit, this is 2.73 / 6 ≈ 0.46 2.73/6\approx0.46 2.73/6 ≈ 0.46 S-unit, rather than nearly a full S-unit. Actual meter indications depend on calibration.

Comparison Table: Vertical Ground Systems & Loading Configurations

System Type RF Loss / Matching Consideration Practical Notes

Ground Rod Only Can leave substantial RF ground loss Do not equate a ground connection with an efficient RF screen

Buried Radials More effective coverage generally reduces near-field loss Count, length, burial and soil all matter

  • Dense Buried Screen Diminishing improvement as loss is reduced Balance benefit against available wire and area
  • Elevated Radials Can provide an effective lower-loss return Check geometry, height, tuning and symmetry

Drooping Ground Plane Often moves resistance toward 50 Ω 50\ \Omega 50 Ω Verify resonance and the actual input match

Base-Loaded Short Vertical Full feed current flows through the loading coil Simple tuning; evaluate coil Q and ground loss

Center-Loaded Short Vertical Loading changes the vertical current distribution May improve efficiency; coil value/current and support matter

Top-Loaded Short Vertical Hat can increase effective height and reduce coil requirement Finite hat size and all losses determine practical efficiency