Study guide
8.2 Standing Waves, Reflection Coefficient, SWR, and Return Loss
ACMA Amateur Radio Advanced Recognition Certificate - Theory Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: DC Theory, Circuit Laws & Passive Components
1.1 DC Circuit Analysis, Ohm's Law, and Kirchhoff's Laws 1.2 AC Fundamentals, Sine Waves, Peak, RMS, and Phase Relationships 1.3 Inductance, Capacitance, Reactance, and Time Constants
2 Chapter 2: Impedance, Resonance & Passive Filters
2.1 Complex Impedance, Phasors, and AC Circuit Analysis 2.2 Series and Parallel LC Resonance and Q Factor 2.3 Passive Filters, Cutoff Frequency, and Attenuator Pads
3 Chapter 3: Semiconductor Devices & Power Supplies
3.1 Semiconductor Diodes, Zener Regulators, and Rectifier Circuits 3.2 Bipolar Junction Transistors, FETs, and Operational Amplifiers 3.3 Thermionic Valves (Vacuum Tubes) and High-Power Linear Amplifiers 3.4 DC Power Supplies, Filter Networks, and Voltage Regulators
4 Chapter 4: Oscillators & Frequency Synthesis
4.1 RF Oscillators, LC Tank Topologies, and Frequency Stability 4.2 Phase-Locked Loops (PLLs) and Frequency Synthesisers 4.3 Direct Digital Synthesis (DDS), SDR Architectures, and Digital Filter Topologies
5 Chapter 5: RF Amplifiers & Linearity
5.1 Classes of Amplification, Conduction Angles, and Operating Efficiency 5.2 RF Power Amplifiers, Push-Pull Topologies, and Output Matching 5.3 Amplifier Stability, Neutralisation, and Intermodulation Distortion
6 Chapter 6: Modulation & Demodulation
6.1 Amplitude Modulation, Double Sideband, and Single Sideband (SSB) 6.2 Frequency Modulation, Phase Modulation, and FM Detectors 6.3 Digital Modulation Modes, Spectral Efficiency, and Weak-Signal Protocols
7 Chapter 7: Transmitters, Mixers & Receivers
7.1 RF Mixers, Frequency Translation, and Intermodulation 7.2 Transmitter Architectures, CW Keying, and Output Filtering 7.3 Superheterodyne Receiver Design, IF Selection, and Image Rejection 7.4 Receiver Performance Specifications, Dynamic Range, and Selectivity
8 Chapter 8: Transmission Lines & Waveguides
8.1 Transmission Line Characteristics, Impedance, and Velocity Factor 8.2 Standing Waves, Reflection Coefficient, SWR, and Return Loss 8.3 Resonant Line Sections, Quarter-Wave Transformers, and Stubs
9 Chapter 9: Impedance Matching & Baluns
9.1 Lumped-Element Matching Networks and Antenna Tuning Units 9.2 Baluns, Ununs, and Common-Mode Current Choking 9.3 Feedline Losses, High-SWR Stress, and Coaxial Installation Practice
10 Chapter 10: Practical Antennas & Arrays
10.1 Resonant Dipoles, Inverted-Vs, and Multiband Wire Antennas 10.2 Quarter-Wave Verticals, Ground Systems, and Radiation Efficiency 10.3 Parasitic Arrays, Yagi-Uda Antennas, and Quad Arrays 10.4 Antenna Gain, Aperture Antennas & Horns, ERP/EIRP, Radiation Patterns
11 Chapter 11: Radio Wave Propagation & Ionospheric Mechanics
11.1 Electromagnetic Wave Fundamentals, Polarisation, and Ground Waves 11.2 The Ionosphere, Solar Radiation, and Solar Cycles 11.3 Critical Frequency, Maximum Usable Frequency, and HF Propagation Paths
12 Chapter 12: VHF/UHF Propagation & Space Communications
12.1 Line-of-Sight, Tropospheric Ducting, and Diffraction 12.2 Sporadic-E, Auroral Scatter, and Trans-Equatorial Propagation 12.3 Amateur Satellites, Doppler Shift, and Earth-Moon-Earth (EME)
13 Chapter 13: Test Equipment & RF Measurements
13.1 Decibels, Power Ratios, and Cascaded Stage Calculations 13.2 RF Power Meters, Directional Couplers, and Dummy Loads 13.3 Multirange Meters, Waveform Diagnostics, Oscilloscopes, and Frequency Counters
14 Chapter 14: Advanced RF Analysis & Diagnostics
14.1 Spectrum Analyser Architecture, Operation, and Spectral Purity 14.2 Antenna Analysers, Vector Network Analysers, and Smith Charts 14.3 Calibrated Signal Generators, Grid Dip Meters, and Component Testing
15 Chapter 15: Electromagnetic Compatibility & Interference
15.1 Sources of Interference, Coupling Mechanisms, and Audio Rectification 15.2 Receiver Susceptibility, Desensitisation, and Front-End Intermodulation 15.3 Practical RFI Suppression, Filter Design, and Bonding Techniques
16 Chapter 16: Electrical, RF & Station Safety
16.1 Biological Effects of RF Energy and ARPANSA Exposure Standards 16.2 Safe Separation Distances, Power Density, and Duty Cycles 16.3 Station Electrical Safety, Battery Hazards, and Safe Headphone Use 16.4 Mast and Tower Construction, Power Line Clearance, and Lightning Protection
8.2 Standing Waves, Reflection Coefficient, SWR, and Return Loss
Key Takeaways Explain This Topic AI
Standing waves develop along a transmission line when an incident forward travelling wave encounters an impedance mismatch at the load ( Z L ≠ Z 0 Z_L \neq Z_0 Z L = Z 0 ), reflecting a portion of the voltage and current backwards toward the generator.
The complex voltage reflection coefficient ( Γ = ( Z L − Z 0 ) / ( Z L + Z 0 ) \Gamma = (Z_L - Z_0) / (Z_L + Z_0) Γ = ( Z L − Z 0 ) / ( Z L + Z 0 ) ) defines the amplitude ratio and phase difference between reflected and forward waves, ranging in magnitude from ∣ Γ ∣ = 0 |\Gamma| = 0 ∣Γ∣ = 0 for a perfect match to ∣ Γ ∣ = 1 |\Gamma| = 1 ∣Γ∣ = 1 for total reflection.
Voltage Standing Wave Ratio ( VSWR = ( 1 + ∣ Γ ∣ ) / ( 1 − ∣ Γ ∣ ) \text{VSWR} = (1 + |\Gamma|) / (1 - |\Gamma|) VSWR = ( 1 + ∣Γ∣ ) / ( 1 − ∣Γ∣ ) ) quantifies the ratio of maximum to minimum voltage along the line, reducing to SWR = R L / Z 0 \text{SWR} = R_L / Z_0 SWR = R L / Z 0 or Z 0 / R L Z_0 / R_L Z 0 / R L for purely resistive loads.
Return loss ( R L = − 20 log 10 ∣ Γ ∣ RL = -20 \log_{10} |\Gamma| R L = − 20 lo g 10 ∣Γ∣ ) and reflected power ratio ( P ref / P fwd = ∣ Γ ∣ 2 P_{\text{ref}} / P_{\text{fwd}} = |\Gamma|^2 P ref / P fwd = ∣Γ ∣ 2 ) measure match quality in decibels and percentage; an SWR of 1.5 : 1 1.5:1 1.5 : 1 corresponds to R L = 14.0 dB RL = 14.0\text{ dB} R L = 14.0 dB and 4 % 4\% 4% reflected power, whereas an SWR of 2.0 : 1 2.0:1 2.0 : 1 reflects 11.1 % 11.1\% 11.1% ( R L = 9.54 dB RL = 9.54\text{ dB} R L = 9.54 dB ).
A mismatched load can stress the transmitter through excessive RF voltage, current or device dissipation. Reflected energy may be absorbed or re-reflected at the source, depending on its design. Power foldback reduces drive or output power to limit this stress.
Last updated: November 2026
8.2 Standing Waves, Reflection Coefficient, SWR, and Return Loss
When a radio transmitter generates alternating electromagnetic energy, it launches a forward-travelling wave of voltage and current along the transmission line toward the antenna. If the impedance presented by the load ( Z L Z_L Z L ) exactly matches the characteristic impedance of the feedline ( Z 0 Z_0 Z 0 ), all incident energy is smoothly absorbed by the load and converted into radiated electromagnetic waves or heat. In this matched state ( Z L = Z 0 Z_L = Z_0 Z L = Z 0 ), the transmission line operates in a pure travelling wave regime.
However, if the load impedance differs from the line's characteristic impedance ( Z L ≠ Z 0 Z_L \neq Z_0 Z L = Z 0 ), boundary conditions at the termination dictate that not all incident energy can be absorbed. The electrical mismatch forces a portion—and in extreme cases, all—of the incident energy to reflect back from the load toward the transmitter. The superposition of the forward-travelling wave and the reverse-travelling reflected wave creates a stationary interference pattern known as a standing wave .
The Mechanism of Standing Waves: Wave Superposition
Let distance x x x be measured along a lossless line from the load ( x = 0 x=0 x = 0 ) toward the generator ( x > 0 x>0 x > 0 ). The complex voltage and current phasors are the sums of the incident and reflected waves below. The instantaneous quantities are Re { V ( x ) e j ω t } \operatorname{Re}\{V(x)e^{j\omega t}\} Re { V ( x ) e jω t } and Re { I ( x ) e j ω t } \operatorname{Re}\{I(x)e^{j\omega t}\} Re { I ( x ) e jω t } . V ( x ) = V + e + j β x + V − e − j β x V(x) = V^+ e^{+j\beta x} + V^- e^{-j\beta x} V ( x ) = V + e + j β x + V − e − j β x I ( x ) = I + e + j β x − I − e − j β x = V + Z 0 e + j β x − V − Z 0 e − j β x I(x) = I^+ e^{+j\beta x} - I^- e^{-j\beta x} = \frac{V^+}{Z_0} e^{+j\beta x} - \frac{V^-}{Z_0} e^{-j\beta x} I ( x ) = I + e + j β x − I − e − j β x = Z 0 V + e + j β x − Z 0 V − e − j β x
where:
V + V^+ V + and V − V^- V − are complex voltage-wave phasors at the load, using peak rather than RMS magnitudes.
I + = V + / Z 0 I^+=V^+/Z_0 I + = V + / Z 0 and I − = V − / Z 0 I^-=V^-/Z_0 I − = V − / Z 0 are the corresponding wave coefficients; the reflected term has the explicit minus sign shown.
β = 2 π / λ \beta = 2\pi / \lambda β = 2 π / λ is the phase constant.
Note
Note the minus sign in the current equation: because the reflected wave travels in the opposite physical direction, its associated magnetic field and current flow are reversed relative to the electric field. Example: Gamma = -0.5, so the load is a voltage minimum.
- Distance from load: 0 lambda/4 lambda/2 3lambda/4 lambda
- Voltage magnitude: Vmin Vmax Vmin Vmax Vmin
- Current magnitude: Imax Imin Imax Imin Imax
Vmax = 1.5 |V+| Vmin = 0.5 |V+| VSWR = 3:1
Adjacent voltage extrema: lambda/4; repeated maxima: lambda/2.
Other reflection phases shift this pattern relative to the load.
Interference Nodes and Antinodes
As the forward and reflected waves travel in opposite directions, their relative phase shift changes continuously with position along the line:
Voltage Antinodes (Voltage Maxima, V max V_{\text{max}} V max ): At points where the forward and reflected voltage phasors align in phase, they interfere constructively, creating a voltage peak: V max = ∣ V + ∣ + ∣ V − ∣ V_{\text{max}} = |V^+| + |V^-| V max = ∣ V + ∣ + ∣ V − ∣
Voltage Nodes (Voltage Minima, V min V_{\text{min}} V min ): At points located a quarter-wavelength ( λ / 4 \lambda/4 λ /4 , or 90 ∘ 90^\circ 9 0 ∘ electrically) away from the antinodes, the forward and reflected voltage phasors are exactly 180 ∘ 180^\circ 18 0 ∘ out of phase, interfering destructively to create a voltage trough: V min = ∣ V + ∣ − ∣ V − ∣ V_{\text{min}} = |V^+| - |V^-| V min = ∣ V + ∣ − ∣ V − ∣
Current Distribution: Because the reflected current is inverted in sign, current antinodes ( I max I_{\text{max}} I max ) occur precisely at voltage nodes ( V min V_{\text{min}} V min ), and current nodes ( I min I_{\text{min}} I min ) occur precisely at voltage antinodes ( V max V_{\text{max}} V max ): I max = ∣ V + ∣ + ∣ V − ∣ Z 0 = V max Z 0 I_{\text{max}} = \frac{|V^+| + |V^-|}{Z_0} = \frac{V_{\text{max}}}{Z_0} I max = Z 0 ∣ V + ∣ + ∣ V − ∣ = Z 0 V max I min = ∣ V + ∣ − ∣ V − ∣ Z 0 = V min Z 0 I_{\text{min}} = \frac{|V^+| - |V^-|}{Z_0} = \frac{V_{\text{min}}}{Z_0} I min = Z 0 ∣ V + ∣ − ∣ V − ∣ = Z 0 V min
Spatial Periodicity: Adjacent nodes and antinodes are separated by λ / 4 \lambda/4 λ /4 ( 90 ∘ 90^\circ 9 0 ∘ ). Successive peaks (or successive troughs) are separated by λ / 2 \lambda/2 λ /2 ( 180 ∘ 180^\circ 18 0 ∘ ).
The Voltage Reflection Coefficient ( Γ \Gamma Γ )
The voltage reflection coefficient (denoted by Γ \Gamma Γ , the uppercase Greek letter gamma, or occasionally ρ \rho ρ , rho) is the complex ratio of the reflected voltage wave to the forward incident voltage wave at the load termination ( x = 0 x = 0 x = 0 ): Γ = V − V + \Gamma = \frac{V^-}{V^+} Γ = V + V −
At the load, the total voltage is V L = V + + V − V_L = V^+ + V^- V L = V + + V − and the total current is I L = ( V + − V − ) / Z 0 I_L = (V^+ - V^-) / Z_0 I L = ( V + − V − ) / Z 0 . By Ohm's law, the load impedance is Z L = V L / I L Z_L = V_L / I_L Z L = V L / I L : Z L = Z 0 ( V + + V − V + − V − ) = Z 0 ( 1 + Γ 1 − Γ ) Z_L = Z_0 \left( \frac{V^+ + V^-}{V^+ - V^-} \right) = Z_0 \left( \frac{1 + \Gamma}{1 - \Gamma} \right) Z L = Z 0 ( V + − V − V + + V − ) = Z 0 ( 1 − Γ 1 + Γ )
Solving explicitly for Γ \Gamma Γ yields the fundamental Reflection Coefficient Formula : Γ = Z L − Z 0 Z L + Z 0 \Gamma = \frac{Z_L - Z_0}{Z_L + Z_0} Γ = Z L + Z 0 Z L − Z 0
Because load impedance Z L = R L + j X L Z_L = R_L + jX_L Z L = R L + j X L is generally a complex number containing both resistance and reactance, Γ \Gamma Γ is also a complex quantity characterized by a scalar magnitude ( ∣ Γ ∣ |\Gamma| ∣Γ∣ ) and a phase angle ( θ \theta θ ): Γ = ∣ Γ ∣ e j θ = ∣ Γ ∣ ∠ θ \Gamma = |\Gamma| e^{j\theta} = |\Gamma| \angle \theta Γ = ∣Γ∣ e j θ = ∣Γ∣∠ θ
The magnitude ∣ Γ ∣ |\Gamma| ∣Γ∣ represents the proportion of incident voltage reflected, bounded strictly between zero and unity: 0 ≤ ∣ Γ ∣ ≤ 1 0 \le |\Gamma| \le 1 0 ≤ ∣Γ∣ ≤ 1 .
The phase angle θ \theta θ represents the phase shift between the reflected voltage wave and the incident voltage wave at the load boundary.
Analysis of Boundary Termination Conditions
Termination Condition Load Impedance ( Z L Z_L Z L ) Reflection Coefficient ( Γ \Gamma Γ ) Voltage Pattern at Load Physical Consequence
Matched Load Z L = Z 0 Z_L = Z_0 Z L = Z 0 Γ = Z 0 − Z 0 Z 0 + Z 0 = 0 \Gamma = \frac{Z_0 - Z_0}{Z_0 + Z_0} = 0 Γ = Z 0 + Z 0 Z 0 − Z 0 = 0 Flat ( V = V + V = V^+ V = V + ) Pure travelling wave; 100 % 100\% 100% power absorbed; zero reflection
Short Circuit Z L = 0 Z_L = 0 Z L = 0 Γ = 0 − Z 0 0 + Z 0 = − 1 = 1 ∠ 180 ∘ \Gamma = \frac{0 - Z_0}{0 + Z_0} = -1 = 1 \angle 180^\circ Γ = 0 + Z 0 0 − Z 0 = − 1 = 1∠18 0 ∘ Voltage Node ( V = 0 V = 0 V = 0 ) Total reflection; voltage inverted 180 ∘ 180^\circ 18 0 ∘ ; current antinode ( I max I_{\text{max}} I max )
Open Circuit Z L = ∞ Z_L = \infty Z L = ∞ Γ = lim Z L → ∞ Z L − Z 0 Z L + Z 0 = + 1 = 1 ∠ 0 ∘ \Gamma = \lim_{Z_L \to \infty} \frac{Z_L - Z_0}{Z_L + Z_0} = +1 = 1 \angle 0^\circ Γ = lim Z L → ∞ Z L + Z 0 Z L − Z 0 = + 1 = 1∠ 0 ∘ Voltage Antinode ( V max V_{\text{max}} V max ) Total reflection; voltage reflected in-phase; current node ( I = 0 I = 0 I = 0 )
Pure Inductor Z L = + j X L Z_L = +jX_L Z L = + j X L Γ = j X L − Z 0 j X L + Z 0 = 1 ∠ θ \Gamma = \frac{jX_L - Z_0}{jX_L + Z_0} = 1 \angle \theta Γ = j X L + Z 0 j X L − Z 0 = 1∠ θ Reactive phase shift ∣ Γ ∣ = 1 \lvert\Gamma\rvert = 1 ∣ Γ ∣ = 1 ; 100% power reflected; phase shift θ = 180 ∘ − 2 arctan ( X L / Z 0 ) \theta = 180^\circ - 2\arctan(X_L/Z_0) θ = 18 0 ∘ − 2 arctan ( X L / Z 0 )
Pure Capacitor Z L = − j X C Z_L = -jX_C Z L = − j X C Γ = − j X C − Z 0 − j X C + Z 0 = 1 ∠ − θ \Gamma = \frac{-jX_C - Z_0}{-jX_C + Z_0} = 1 \angle -\theta Γ = − j X C + Z 0 − j X C − Z 0 = 1∠ − θ Reactive phase shift ∣ Γ ∣ = 1 \lvert\Gamma\rvert = 1 ∣ Γ ∣ = 1 ; 100% power reflected; phase shift θ = − ( 180 ∘ − 2 arctan ( X C / Z 0 ) ) \theta = -(180^\circ - 2\arctan(X_C/Z_0)) θ = − ( 18 0 ∘ − 2 arctan ( X C / Z 0 ))
Important
For any purely reactive termination ( Z L = ± j X Z_L = \pm jX Z L = ± j X ), the magnitude of the reflection coefficient is always exactly unity ( ∣ Γ ∣ = 1.0 |\Gamma| = 1.0 ∣Γ∣ = 1.0 ), meaning that 100 % 100\% 100% of the incident power is reflected , regardless of the value of reactance X X X .
Voltage Standing Wave Ratio (VSWR)
The Voltage Standing Wave Ratio (VSWR, or simply SWR ) is defined as the ratio of the maximum RF envelope voltage ( V max V_{\text{max}} V max ) to the minimum RF envelope voltage ( V min V_{\text{min}} V min ) along the transmission line: VSWR = V max V min = ∣ V + ∣ + ∣ V − ∣ ∣ V + ∣ − ∣ V − ∣ \text{VSWR} = \frac{V_{\text{max}}}{V_{\text{min}}} = \frac{|V^+| + |V^-|}{|V^+| - |V^-|} VSWR = V min V max = ∣ V + ∣ − ∣ V − ∣ ∣ V + ∣ + ∣ V − ∣
Factoring out ∣ V + ∣ |V^+| ∣ V + ∣ from numerator and denominator, and recognizing that ∣ V − ∣ / ∣ V + ∣ = ∣ Γ ∣ |V^-| / |V^+| = |\Gamma| ∣ V − ∣/∣ V + ∣ = ∣Γ∣ : VSWR = 1 + ∣ Γ ∣ 1 − ∣ Γ ∣ \text{VSWR} = \frac{1 + |\Gamma|}{1 - |\Gamma|} VSWR = 1 − ∣Γ∣ 1 + ∣Γ∣
Conversely, given a known VSWR, the magnitude of the reflection coefficient is uniquely determined: ∣ Γ ∣ = VSWR − 1 VSWR + 1 |\Gamma| = \frac{\text{VSWR} - 1}{\text{VSWR} + 1} ∣Γ∣ = VSWR + 1 VSWR − 1
Because 0 ≤ ∣ Γ ∣ ≤ 1 0 \le |\Gamma| \le 1 0 ≤ ∣Γ∣ ≤ 1 , SWR values range from a minimum of 1.0 1.0 1.0 (expressed as 1 : 1 1:1 1 : 1 or 1.0 : 1 1.0:1 1.0 : 1 ) for a perfectly matched line, up to infinity ( ∞ : 1 \infty:1 ∞ : 1 ) for total reflection (short, open, or pure reactance).
SWR for Purely Resistive Loads
When the load is non-reactive ( Z L = R L + j 0 Z_L = R_L + j0 Z L = R L + j 0 ), the reflection coefficient formula simplifies to: Γ = R L − Z 0 R L + Z 0 \Gamma = \frac{R_L - Z_0}{R_L + Z_0} Γ = R L + Z 0 R L − Z 0
Substituting this into the VSWR equation yields two straightforward rules: SWR = R L Z 0 ( when R L > Z 0 ) \text{SWR} = \frac{R_L}{Z_0} \quad (\text{when } R_L > Z_0) SWR = Z 0 R L ( when R L > Z 0 ) SWR = Z 0 R L ( when R L < Z 0 ) \text{SWR} = \frac{Z_0}{R_L} \quad (\text{when } R_L < Z_0) SWR = R L Z 0 ( when R L < Z 0 )
Practical Example: The Duality of Resistive Mismatches
Consider a standard 50 Ω 50\ \Omega 50 Ω transmission line:
Terminating in a 150 Ω 150\ \Omega 150 Ω resistor: SWR = 150 / 50 = 3.0 : 1 \text{SWR} = 150 / 50 = 3.0:1 SWR = 150/50 = 3.0 : 1 . The reflection coefficient is Γ = ( 150 − 50 ) / ( 150 + 50 ) = + 0.50 \Gamma = (150 - 50)/(150 + 50) = +0.50 Γ = ( 150 − 50 ) / ( 150 + 50 ) = + 0.50 .
Terminating in a 16.67 Ω 16.67\ \Omega 16.67 Ω resistor: SWR = 50 / 16.67 = 3.0 : 1 \text{SWR} = 50 / 16.67 = 3.0:1 SWR = 50/16.67 = 3.0 : 1 . The reflection coefficient is Γ = ( 16.67 − 50 ) / ( 16.67 + 50 ) = − 0.50 = 0.50 ∠ 180 ∘ \Gamma = (16.67 - 50)/(16.67 + 50) = -0.50 = 0.50 \angle 180^\circ Γ = ( 16.67 − 50 ) / ( 16.67 + 50 ) = − 0.50 = 0.50∠18 0 ∘ .
Both loads produce an identical standing wave ratio ( 3.0 : 1 3.0:1 3.0 : 1 ) and reflect the exact same percentage of incident power ( ∣ Γ ∣ 2 = 0.25 = 25 % |\Gamma|^2 = 0.25 = 25\% ∣Γ ∣ 2 = 0.25 = 25% ). However, at the load boundary, the 150 Ω 150\ \Omega 150 Ω termination creates a voltage antinode ( V max V_{\text{max}} V max ), whereas the 16.67 Ω 16.67\ \Omega 16.67 Ω termination creates a voltage node ( V min V_{\text{min}} V min ) and current antinode ( I max I_{\text{max}} I max ).
Return Loss ( R L RL R L ) and Reflected Power Ratios
In RF laboratory testing and professional telecommunications, engineers frequently express impedance match quality using Return Loss ( R L RL R L ) and power ratios rather than VSWR.
Reflected Power Ratio
The power carried by a forward-travelling wave is P fwd = ∣ V + ∣ 2 / ( 2 Z 0 ) P_{\text{fwd}} = |V^+|^2 / (2Z_0) P fwd = ∣ V + ∣ 2 / ( 2 Z 0 ) , and the power carried by the reflected wave is P ref = ∣ V − ∣ 2 / ( 2 Z 0 ) P_{\text{ref}} = |V^-|^2 / (2Z_0) P ref = ∣ V − ∣ 2 / ( 2 Z 0 ) . The ratio of reflected power to forward incident power is: P ref P fwd = ∣ V − V + ∣ 2 = ∣ Γ ∣ 2 \frac{P_{\text{ref}}}{P_{\text{fwd}}} = \left| \frac{V^-}{V^+} \right|^2 = |\Gamma|^2 P fwd P ref = V + V − 2 = ∣Γ ∣ 2
The fraction of incident power accepted by the load is the difference between forward and reflected powers at that load plane. Antenna radiation is only part of accepted power if the antenna also dissipates energy as heat: P absorbed P fwd = 1 − ∣ Γ ∣ 2 = 1 − ( VSWR − 1 VSWR + 1 ) 2 \frac{P_{\text{absorbed}}}{P_{\text{fwd}}} = 1 - |\Gamma|^2 = 1 - \left( \frac{\text{VSWR} - 1}{\text{VSWR} + 1} \right)^2 P fwd P absorbed = 1 − ∣Γ ∣ 2 = 1 − ( VSWR + 1 VSWR − 1 ) 2
Return Loss Formula
Return Loss ( R L RL R L ), expressed in decibels ( dB \text{dB} dB ), is defined as the logarithmic ratio of forward incident power to reflected power: R L = − 20 log 10 ∣ Γ ∣ = − 10 log 10 ( P ref P fwd ) RL = -20 \log_{10}|\Gamma| = -10 \log_{10}\left( \frac{P_{\text{ref}}}{P_{\text{fwd}}} \right) R L = − 20 lo g 10 ∣Γ∣ = − 10 lo g 10 ( P fwd P ref )
Tip
In return loss notation, a larger positive decibel number indicates a superior impedance match :
R L = ∞ dB RL = \infty\text{ dB} R L = ∞ dB : Perfect match ( ∣ Γ ∣ = 0 |\Gamma| = 0 ∣Γ∣ = 0 , SWR = 1.0 : 1 \text{SWR} = 1.0:1 SWR = 1.0 : 1 ), zero power reflected.
R L = 20 dB RL = 20\text{ dB} R L = 20 dB : Excellent match ( ∣ Γ ∣ = 0.10 |\Gamma| = 0.10 ∣Γ∣ = 0.10 , SWR = 1.22 : 1 \text{SWR} = 1.22:1 SWR = 1.22 : 1 ), only 1.0 % 1.0\% 1.0% of incident power is reflected.
R L = 14 dB RL = 14\text{ dB} R L = 14 dB : Standard good amateur antenna match ( ∣ Γ ∣ = 0.20 |\Gamma| = 0.20 ∣Γ∣ = 0.20 , SWR ≈ 1.5 : 1 \text{SWR} \approx 1.5:1 SWR ≈ 1.5 : 1 ), 4.0 % 4.0\% 4.0% reflected power.
R L = 9.54 dB RL = 9.54\text{ dB} R L = 9.54 dB : Marginal match ( ∣ Γ ∣ = 0.333 |\Gamma| = 0.333 ∣Γ∣ = 0.333 , SWR = 2.0 : 1 \text{SWR} = 2.0:1 SWR = 2.0 : 1 ), 11.1 % 11.1\% 11.1% reflected power.
R L = 6.02 dB RL = 6.02\text{ dB} R L = 6.02 dB : Poor match ( ∣ Γ ∣ = 0.50 |\Gamma| = 0.50 ∣Γ∣ = 0.50 , SWR = 3.0 : 1 \text{SWR} = 3.0:1 SWR = 3.0 : 1 ), 25.0 % 25.0\% 25.0% reflected power.
R L = 0 dB RL = 0\text{ dB} R L = 0 dB : Total reflection ( ∣ Γ ∣ = 1.0 |\Gamma| = 1.0 ∣Γ∣ = 1.0 , SWR = ∞ : 1 \text{SWR} = \infty:1 SWR = ∞ : 1 ), 100 % 100\% 100% of power reflected.
Master Conversion Table: SWR, Reflection Coefficient, Return Loss, and Power
VSWR Reflection Coeff. ( ∣ Γ ∣ \lvert\Gamma\rvert ∣ Γ ∣ ) Return Loss ( R L RL R L , dB) Reflected Power ( P ref / P fwd P_{\text{ref}} / P_{\text{fwd}} P ref / P fwd ) Power Accepted by Load Voltage Envelope ( V max / V min V_{\text{max}} / V_{\text{min}} V max / V min )
1.0:1 0.000 0.000 0.000 ∞ dB \infty\text{ dB} ∞ dB 0.00 % 0.00\% 0.00% 100.00 % 100.00\% 100.00% 1.00 × V 0 1.00 \times V_0 1.00 × V 0
1.1:1 0.048 0.048 0.048 26.44 dB 26.44\text{ dB} 26.44 dB 0.23 % 0.23\% 0.23% 99.77 % 99.77\% 99.77% 1.05 / 0.95 1.05 / 0.95 1.05/0.95
1.2:1 0.091 0.091 0.091 20.83 dB 20.83\text{ dB} 20.83 dB 0.83 % 0.83\% 0.83% 99.17 % 99.17\% 99.17% 1.09 / 0.91 1.09 / 0.91 1.09/0.91
1.3:1 0.130 0.130 0.130 17.69 dB 17.69\text{ dB} 17.69 dB 1.70 % 1.70\% 1.70% 98.30 % 98.30\% 98.30% 1.13 / 0.87 1.13 / 0.87 1.13/0.87
1.5:1 0.200 0.200 0.200 13.98 dB 13.98\text{ dB} 13.98 dB 4.00 % 4.00\% 4.00% 96.00 % 96.00\% 96.00% 1.20 / 0.80 1.20 / 0.80 1.20/0.80
1.7:1 0.259 0.259 0.259 11.73 dB 11.73\text{ dB} 11.73 dB 6.72 % 6.72\% 6.72% 93.28 % 93.28\% 93.28% 1.26 / 0.74 1.26 / 0.74 1.26/0.74
2.0:1 0.333 0.333 0.333 9.54 dB 9.54\text{ dB} 9.54 dB 11.11 % 11.11\% 11.11% 88.89 % 88.89\% 88.89% 1.33 / 0.67 1.33 / 0.67 1.33/0.67
2.5:1 0.429 0.429 0.429 7.36 dB 7.36\text{ dB} 7.36 dB 18.37 % 18.37\% 18.37% 81.63 % 81.63\% 81.63% 1.43 / 0.57 1.43 / 0.57 1.43/0.57
3.0:1 0.500 0.500 0.500 6.02 dB 6.02\text{ dB} 6.02 dB 25.00 % 25.00\% 25.00% 75.00 % 75.00\% 75.00% 1.50 / 0.50 1.50 / 0.50 1.50/0.50
4.0:1 0.600 0.600 0.600 4.44 dB 4.44\text{ dB} 4.44 dB 36.00 % 36.00\% 36.00% 64.00 % 64.00\% 64.00% 1.60 / 0.40 1.60 / 0.40 1.60/0.40
5.0:1 0.667 0.667 0.667 3.52 dB 3.52\text{ dB} 3.52 dB 44.44 % 44.44\% 44.44% 55.56 % 55.56\% 55.56% 1.67 / 0.33 1.67 / 0.33 1.67/0.33
10.0:1 0.818 0.818 0.818 1.74 dB 1.74\text{ dB} 1.74 dB 66.94 % 66.94\% 66.94% 33.06 % 33.06\% 33.06% 1.82 / 0.18 1.82 / 0.18 1.82/0.18
∞ : 1 \infty:1 ∞ : 1 1.000 1.000 1.000 0.00 dB 0.00\text{ dB} 0.00 dB 100.00 % 100.00\% 100.00% 0.00 % 0.00\% 0.00% 2.00 / 0.00 2.00 / 0.00 2.00/0.00
Practical Realities and Common SWR Myths
High SWR means a mismatch at the measurement plane. Its effect on a transmitter depends on the impedance presented to the final stage and the amplifier’s ruggedness and protection. Both electrical breakdown and excessive dissipation are possible; reflected-power heating is not forbidden by electromagnetic theory.
What Actually Happens to Reflected Power?
Source-End Behavior: A returning wave may be absorbed or re-reflected, depending on the impedance looking toward the source. A matched termination absorbs an incoming wave. An ATU transforms the feedline input impedance to a suitable transmitter load; it does not automatically eliminate standing waves on the antenna side or guarantee that all returning power is re-reflected.
Energy Conservation: Separate transmitter output, line dissipation, power accepted by the antenna and power radiated. For a low-loss line with approximately real Z 0 Z_0 Z 0 , a matched-line loss of 0.2 dB 0.2\text{ dB} 0.2 dB and load SWR of 10 : 1 10:1 10 : 1 give about 0.91 dB 0.91\text{ dB} 0.91 dB total line loss, or 81 % 81\% 81% transfer of net line-input power to the load. Antenna losses reduce the radiated fraction further. Settling time depends on line delay, reflections and circuit response.
The SWR Loss Penalty on Lossy Coax: Why, then, is high SWR undesirable on coaxial feedlines? Because on a lossy transmission line (such as RG-58 at 144 MHz 144\text{ MHz} 144 MHz ), every time the reflected wave traverses back and forth across the line, it suffers the cable's normal attenuation. Higher standing wave current antinodes ( I max I_{\text{max}} I max ) dramatically increase I 2 R ′ I^2 R' I 2 R ′ conductor skin heating, and voltage antinodes ( V max V_{\text{max}} V max ) increase V 2 G ′ V^2 G' V 2 G ′ dielectric heating. This compounding effect is known as the additional SWR loss penalty .
Transmitter Protection Circuits: Power Foldback
How does automatic power foldback reduce the risk from an antenna mismatch?
Peak Transistor Voltage and Current Ratings: Solid-state bipolar junction transistors (BJTs) and laterally diffused MOSFETs (LDMOS) have strict absolute maximum ratings for collector-emitter breakdown voltage ( B V ceo BV_{\text{ceo}} B V ceo ) or drain-source breakdown voltage ( V dss V_{\text{dss}} V dss ), as well as maximum safe operating current ( I max I_{\text{max}} I max ).
Adverse Load Impedance: Feedline length transforms a mismatch to different impedances at the transmitter. The resulting RF voltage/current swings can exceed device ratings, while reduced amplifier efficiency can increase heat dissipation. The severity depends on reflection phase, power level and circuit design.
Power Foldback: A protection circuit senses reflected power or related device stress and reduces drive, gain or supply voltage. This reduces available output power and helps protect the final stage. Thresholds, response speed and the control path depend on the transceiver; follow its specified mismatch limits.
Step-by-Step Worked Calculation: Complex Load Mismatch
An amateur antenna system operating on the 20-meter band ( 14.15 MHz 14.15\text{ MHz} 14.15 MHz ) uses a 50 Ω 50\ \Omega 50 Ω coaxial feedline. An antenna analyzer connected to the line measures a complex load impedance of: Z L = 75 + j 50 Ω Z_L = 75 + j50\ \Omega Z L = 75 + j 50 Ω
Calculate:
- The complex voltage reflection coefficient ( Γ \Gamma Γ )
- The magnitude ( ∣ Γ ∣ |\Gamma| ∣Γ∣ ) and phase angle ( θ \theta θ )
- The Voltage Standing Wave Ratio (VSWR)
- The Return Loss ( R L RL R L ) in decibels
- The percentage of forward incident power reflected
Step 1: Calculate the Complex Reflection Coefficient ( Γ \Gamma Γ ) Γ = Z L − Z 0 Z L + Z 0 = ( 75 + j 50 ) − 50 ( 75 + j 50 ) + 50 = 25 + j 50 125 + j 50 \Gamma = \frac{Z_L - Z_0}{Z_L + Z_0} = \frac{(75 + j50) - 50}{(75 + j50) + 50} = \frac{25 + j50}{125 + j50} Γ = Z L + Z 0 Z L − Z 0 = ( 75 + j 50 ) + 50 ( 75 + j 50 ) − 50 = 125 + j 50 25 + j 50
To divide complex numbers, multiply numerator and denominator by the complex conjugate of the denominator ( 125 − j 50 125 - j50 125 − j 50 ): Γ = ( 25 + j 50 ) ( 125 − j 50 ) ( 125 + j 50 ) ( 125 − j 50 ) = ( 25 × 125 ) − j ( 25 × 50 ) + j ( 50 × 125 ) − j 2 ( 50 × 50 ) 125 2 + 50 2 \Gamma = \frac{(25 + j50)(125 - j50)}{(125 + j50)(125 - j50)} = \frac{(25 \times 125) - j(25 \times 50) + j(50 \times 125) - j^2(50 \times 50)}{125^2 + 50^2} Γ = ( 125 + j 50 ) ( 125 − j 50 ) ( 25 + j 50 ) ( 125 − j 50 ) = 12 5 2 + 5 0 2 ( 25 × 125 ) − j ( 25 × 50 ) + j ( 50 × 125 ) − j 2 ( 50 × 50 ) Γ = 3125 − j 1250 + j 6250 + 2500 15625 + 2500 = 5625 + j 5000 18125 \Gamma = \frac{3125 - j1250 + j6250 + 2500}{15625 + 2500} = \frac{5625 + j5000}{18125} Γ = 15625 + 2500 3125 − j 1250 + j 6250 + 2500 = 18125 5625 + j 5000 Γ ≈ 0.3103 + j 0.2759 \Gamma \approx 0.3103 + j0.2759 Γ ≈ 0.3103 + j 0.2759
Step 2: Determine Magnitude ( ∣ Γ ∣ |\Gamma| ∣Γ∣ ) and Phase Angle ( θ \theta θ ) ∣ Γ ∣ = ( 0.3103 ) 2 + ( 0.2759 ) 2 = 0.0963 + 0.0761 = 0.1724 ≈ 0.4152 |\Gamma| = \sqrt{(0.3103)^2 + (0.2759)^2} = \sqrt{0.0963 + 0.0761} = \sqrt{0.1724} \approx 0.4152 ∣Γ∣ = ( 0.3103 ) 2 + ( 0.2759 ) 2 = 0.0963 + 0.0761 = 0.1724 ≈ 0.4152 θ = arctan ( 0.2759 0.3103 ) = arctan ( 0.8891 ) ≈ 41.64 ∘ \theta = \arctan\left(\frac{0.2759}{0.3103}\right) = \arctan(0.8891) \approx 41.64^\circ θ = arctan ( 0.3103 0.2759 ) = arctan ( 0.8891 ) ≈ 41.6 4 ∘
In polar form: Γ ≈ 0.4152 ∠ 41.64 ∘ \Gamma \approx 0.4152 \angle 41.64^\circ Γ ≈ 0.4152∠41.6 4 ∘ .
Step 3: Calculate the Voltage Standing Wave Ratio (VSWR) VSWR = 1 + ∣ Γ ∣ 1 − ∣ Γ ∣ = 1 + 0.4152 1 − 0.4152 = 1.4152 0.5848 ≈ 2.42 : 1 \text{VSWR} = \frac{1 + |\Gamma|}{1 - |\Gamma|} = \frac{1 + 0.4152}{1 - 0.4152} = \frac{1.4152}{0.5848} \approx 2.42:1 VSWR = 1 − ∣Γ∣ 1 + ∣Γ∣ = 1 − 0.4152 1 + 0.4152 = 0.5848 1.4152 ≈ 2.42 : 1
Step 4: Calculate Return Loss ( R L RL R L ) R L = − 20 log 10 ∣ Γ ∣ = − 20 log 10 ( 0.4152 ) = − 20 × ( − 0.3818 ) ≈ 7.64 dB RL = -20 \log_{10}|\Gamma| = -20 \log_{10}(0.4152) = -20 \times (-0.3818) \approx 7.64\text{ dB} R L = − 20 lo g 10 ∣Γ∣ = − 20 lo g 10 ( 0.4152 ) = − 20 × ( − 0.3818 ) ≈ 7.64 dB
Step 5: Determine Reflected Power Percentage P ref P fwd = ∣ Γ ∣ 2 = ( 0.4152 ) 2 ≈ 0.1724 = 17.24 % \frac{P_{\text{ref}}}{P_{\text{fwd}}} = |\Gamma|^2 = (0.4152)^2 \approx 0.1724 = 17.24\% P fwd P ref = ∣Γ ∣ 2 = ( 0.4152 ) 2 ≈ 0.1724 = 17.24%
If the transmitter delivers 100 W 100\text{ W} 100 W forward incident power, approximately 17.2 W 17.2\text{ W} 17.2 W is reflected by the load mismatch, leaving 82.8 W 82.8\text{ W} 82.8 W absorbed by the antenna system on the initial wave passage.