Study guide
8.1 Transmission Line Characteristics, Impedance, and Velocity Factor
ACMA Amateur Radio Advanced Recognition Certificate - Theory Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: DC Theory, Circuit Laws & Passive Components
1.1 DC Circuit Analysis, Ohm's Law, and Kirchhoff's Laws 1.2 AC Fundamentals, Sine Waves, Peak, RMS, and Phase Relationships 1.3 Inductance, Capacitance, Reactance, and Time Constants
2 Chapter 2: Impedance, Resonance & Passive Filters
2.1 Complex Impedance, Phasors, and AC Circuit Analysis 2.2 Series and Parallel LC Resonance and Q Factor 2.3 Passive Filters, Cutoff Frequency, and Attenuator Pads
3 Chapter 3: Semiconductor Devices & Power Supplies
3.1 Semiconductor Diodes, Zener Regulators, and Rectifier Circuits 3.2 Bipolar Junction Transistors, FETs, and Operational Amplifiers 3.3 Thermionic Valves (Vacuum Tubes) and High-Power Linear Amplifiers 3.4 DC Power Supplies, Filter Networks, and Voltage Regulators
4 Chapter 4: Oscillators & Frequency Synthesis
4.1 RF Oscillators, LC Tank Topologies, and Frequency Stability 4.2 Phase-Locked Loops (PLLs) and Frequency Synthesisers 4.3 Direct Digital Synthesis (DDS), SDR Architectures, and Digital Filter Topologies
5 Chapter 5: RF Amplifiers & Linearity
5.1 Classes of Amplification, Conduction Angles, and Operating Efficiency 5.2 RF Power Amplifiers, Push-Pull Topologies, and Output Matching 5.3 Amplifier Stability, Neutralisation, and Intermodulation Distortion
6 Chapter 6: Modulation & Demodulation
6.1 Amplitude Modulation, Double Sideband, and Single Sideband (SSB) 6.2 Frequency Modulation, Phase Modulation, and FM Detectors 6.3 Digital Modulation Modes, Spectral Efficiency, and Weak-Signal Protocols
7 Chapter 7: Transmitters, Mixers & Receivers
7.1 RF Mixers, Frequency Translation, and Intermodulation 7.2 Transmitter Architectures, CW Keying, and Output Filtering 7.3 Superheterodyne Receiver Design, IF Selection, and Image Rejection 7.4 Receiver Performance Specifications, Dynamic Range, and Selectivity
8 Chapter 8: Transmission Lines & Waveguides
8.1 Transmission Line Characteristics, Impedance, and Velocity Factor 8.2 Standing Waves, Reflection Coefficient, SWR, and Return Loss 8.3 Resonant Line Sections, Quarter-Wave Transformers, and Stubs
9 Chapter 9: Impedance Matching & Baluns
9.1 Lumped-Element Matching Networks and Antenna Tuning Units 9.2 Baluns, Ununs, and Common-Mode Current Choking 9.3 Feedline Losses, High-SWR Stress, and Coaxial Installation Practice
10 Chapter 10: Practical Antennas & Arrays
10.1 Resonant Dipoles, Inverted-Vs, and Multiband Wire Antennas 10.2 Quarter-Wave Verticals, Ground Systems, and Radiation Efficiency 10.3 Parasitic Arrays, Yagi-Uda Antennas, and Quad Arrays 10.4 Antenna Gain, Aperture Antennas & Horns, ERP/EIRP, Radiation Patterns
11 Chapter 11: Radio Wave Propagation & Ionospheric Mechanics
11.1 Electromagnetic Wave Fundamentals, Polarisation, and Ground Waves 11.2 The Ionosphere, Solar Radiation, and Solar Cycles 11.3 Critical Frequency, Maximum Usable Frequency, and HF Propagation Paths
12 Chapter 12: VHF/UHF Propagation & Space Communications
12.1 Line-of-Sight, Tropospheric Ducting, and Diffraction 12.2 Sporadic-E, Auroral Scatter, and Trans-Equatorial Propagation 12.3 Amateur Satellites, Doppler Shift, and Earth-Moon-Earth (EME)
13 Chapter 13: Test Equipment & RF Measurements
13.1 Decibels, Power Ratios, and Cascaded Stage Calculations 13.2 RF Power Meters, Directional Couplers, and Dummy Loads 13.3 Multirange Meters, Waveform Diagnostics, Oscilloscopes, and Frequency Counters
14 Chapter 14: Advanced RF Analysis & Diagnostics
14.1 Spectrum Analyser Architecture, Operation, and Spectral Purity 14.2 Antenna Analysers, Vector Network Analysers, and Smith Charts 14.3 Calibrated Signal Generators, Grid Dip Meters, and Component Testing
15 Chapter 15: Electromagnetic Compatibility & Interference
15.1 Sources of Interference, Coupling Mechanisms, and Audio Rectification 15.2 Receiver Susceptibility, Desensitisation, and Front-End Intermodulation 15.3 Practical RFI Suppression, Filter Design, and Bonding Techniques
16 Chapter 16: Electrical, RF & Station Safety
16.1 Biological Effects of RF Energy and ARPANSA Exposure Standards 16.2 Safe Separation Distances, Power Density, and Duty Cycles 16.3 Station Electrical Safety, Battery Hazards, and Safe Headphone Use 16.4 Mast and Tower Construction, Power Line Clearance, and Lightning Protection
8.1 Transmission Line Characteristics, Impedance, and Velocity Factor
Key Takeaways Explain This Topic AI
A transmission line is modeled by distributed primary parameters per unit length: series resistance ( R ′ R' R ′ in Ω / m \Omega/\text{m} Ω/ m ), series inductance ( L ′ L' L ′ in H/m \text{H/m} H/m ), shunt conductance ( G ′ G' G ′ in S/m \text{S/m} S/m ), and shunt capacitance ( C ′ C' C ′ in F/m \text{F/m} F/m ).
At radio frequencies where R ′ ≪ ω L ′ R' \ll \omega L' R ′ ≪ ω L ′ and G ′ ≪ ω C ′ G' \ll \omega C' G ′ ≪ ω C ′ , the characteristic impedance simplifies to Z 0 = L ′ / C ′ Z_0 = \sqrt{L'/C'} Z 0 = L ′ / C ′ , behaving as a purely resistive surge impedance independent of line length.
The velocity factor ( V F = 1 / ε r VF = 1/\sqrt{\varepsilon_r} V F = 1/ ε r ) quantifies the ratio of signal velocity in the dielectric to the speed of light in vacuum, directly scaling the physical length corresponding to a given electrical fraction of a wavelength ( l phys = V F × l free space l_{\text{phys}} = VF \times l_{\text{free space}} l phys = V F × l free space ).
Conductor skin-effect loss grows approximately with f \sqrt f f , while dielectric loss grows approximately with f f f for constant loss tangent. Select feedline using its loss data; balanced open-wire lines also require close conductor spacing relative to wavelength and equal, opposite currents.
Hollow metal waveguides act as high-pass transmission media supporting transverse electric ( T E TE TE ) and transverse magnetic ( T M TM TM ) modes above a cutoff frequency ( f c = c / ( 2 a ) f_c = c / (2a) f c = c / ( 2 a ) for T E 10 TE_{10} T E 10 ), providing ultra-low loss power handling at microwave frequencies where coaxial cables become impractical.
Last updated: November 2026
8.1 Transmission Line Characteristics, Impedance, and Velocity Factor
In direct current (DC) and low-frequency alternating current (AC) circuits, interconnecting conductors are routinely treated as ideal equipotential nodes. According to Kirchhoff's current and voltage laws, the current entering one end of a wire instantaneously equals the current exiting the other end, and the potential difference along the wire is assumed to be negligible. This lumped-element approximation holds true only as long as the physical length of the circuit remains negligibly small compared to the wavelength ( λ \lambda λ ) of the electromagnetic energy being transported—typically when the physical length is less than λ / 16 \lambda / 16 λ /16 or 0.1 λ 0.1\lambda 0.1 λ .
In radio frequency (RF) engineering, where frequencies span from high frequency (HF, 3 to 30 MHz 3\text{ to }30\text{ MHz} 3 to 30 MHz ) through very high frequency (VHF, 30 to 300 MHz 30\text{ to }300\text{ MHz} 30 to 300 MHz ) and ultra-high frequency (UHF, 300 to 3000 MHz 300\text{ to }3000\text{ MHz} 300 to 3000 MHz ), operational wavelengths shrink from 100 meters 100\text{ meters} 100 meters down to mere centimeters. Under these conditions, the physical length of the interconnecting cable between a transceiver and an antenna is often several wavelengths long. The transit time of the electromagnetic wave across the line becomes a substantial fraction of the RF wave's period, causing voltage and current to vary continuously in magnitude and phase along the conductor. Such an interconnection can no longer be modeled as a simple lumped wire; it must be analyzed as a distributed parameter transmission line .
The Distributed Parameter Model (Primary Line Constants)
A transmission line consists of two or more parallel conductors guiding electromagnetic energy from a source (such as a transmitter) to a load (such as an antenna). Because the inductance, capacitance, resistance, and dielectric leakage are distributed continuously along the entire length of the cable rather than concentrated in discrete components, engineers model the line as an infinite cascade of infinitesimally short segments of length Δ x \Delta x Δ x . R' dx L' dx
- upper o----[ R ]---------[ L ]----+------------+----o upper
- | |
- [ C' dx ] [ G' dx ]
- | |
- return o--------------------------+------------+----o return
V(x) is measured upper-to-return at the left.
V(x+dx) is measured upper-to-return at the right.
Each infinitesimal segment Δ x \Delta x Δ x is governed by four primary line constants :
Distributed Series Resistance ( R ′ R' R ′ ): Measured in ohms per meter ( Ω / m \Omega/\text{m} Ω/ m ), representing the combined ohmic resistance of both conductors per unit length. At radio frequencies, R ′ R' R ′ is not constant; it increases with the square root of frequency ( f \sqrt{f} f ) due to the skin effect , where alternating current crowds into a shallow depth along the conductor surface.
Distributed Series Inductance ( L ′ L' L ′ ): Measured in henrys per meter ( H/m \text{H/m} H/m ), representing the total self-inductance of the conductors and the magnetic flux linkage established in the space between and around them per unit length.
Distributed Shunt Conductance ( G ′ G' G ′ ): Measured in siemens per meter ( S/m \text{S/m} S/m ), representing the leakage current flowing through the imperfect insulating dielectric separating the two conductors per unit length. In high-grade RF lines, G ′ G' G ′ is extremely small but increases with frequency due to dielectric hysteresis losses.
Distributed Shunt Capacitance ( C ′ C' C ′ ): Measured in farads per meter ( F/m \text{F/m} F/m ), representing the electrostatic capacitance established between the conductors across the intervening dielectric per unit length.
The Telegrapher's Equations and Wave Propagation
Applying Kirchhoff's voltage and current laws to the infinitesimal segment of length Δ x \Delta x Δ x as Δ x → 0 \Delta x \to 0 Δ x → 0 yields the foundational Telegrapher's Equations for sinusoidal steady-state RF signals ( e j ω t e^{j\omega t} e jω t ): d V ( x ) d x = − ( R ′ + j ω L ′ ) I ( x ) \frac{dV(x)}{dx} = -(R' + j\omega L') I(x) d x d V ( x ) = − ( R ′ + jω L ′ ) I ( x ) d I ( x ) d x = − ( G ′ + j ω C ′ ) V ( x ) \frac{dI(x)}{dx} = -(G' + j\omega C') V(x) d x d I ( x ) = − ( G ′ + jω C ′ ) V ( x )
where ω = 2 π f \omega = 2\pi f ω = 2 π f is the angular frequency in radians per second. Differentiating these first-order coupled equations and substituting one into the other yields the second-order uncoupled wave equations : d 2 V ( x ) d x 2 = γ 2 V ( x ) \frac{d^2 V(x)}{dx^2} = \gamma^2 V(x) d x 2 d 2 V ( x ) = γ 2 V ( x ) d 2 I ( x ) d x 2 = γ 2 I ( x ) \frac{d^2 I(x)}{dx^2} = \gamma^2 I(x) d x 2 d 2 I ( x ) = γ 2 I ( x )
where γ \gamma γ is the complex propagation constant : γ = α + j β = ( R ′ + j ω L ′ ) ( G ′ + j ω C ′ ) \gamma = \alpha + j\beta = \sqrt{(R' + j\omega L')(G' + j\omega C')} γ = α + j β = ( R ′ + jω L ′ ) ( G ′ + jω C ′ )
The real part, α \alpha α , is the attenuation constant (measured in nepers per meter, convertible to dB/m \text{dB/m} dB/m via 1 Np ≈ 8.686 dB 1\text{ Np} \approx 8.686\text{ dB} 1 Np ≈ 8.686 dB ), representing signal amplitude decay per unit distance due to heat dissipation.
The imaginary part, β \beta β , is the phase constant (measured in radians per meter, β = 2 π / λ \beta = 2\pi / \lambda β = 2 π / λ ), representing the spatial phase rotation of the wave as it travels along the line.
Characteristic Impedance ( Z 0 Z_0 Z 0 )
The characteristic impedance ( Z 0 Z_0 Z 0 ), also termed the surge impedance, is defined as the ratio of the forward-travelling voltage wave to the forward-travelling current wave at any point on a uniform line of infinite length, or on a line of finite length terminated in an impedance equal to Z 0 Z_0 Z 0 : Z 0 = V + ( x ) I + ( x ) = R ′ + j ω L ′ G ′ + j ω C ′ Z_0 = \frac{V^+(x)}{I^+(x)} = \sqrt{\frac{R' + j\omega L'}{G' + j\omega C'}} Z 0 = I + ( x ) V + ( x ) = G ′ + jω C ′ R ′ + jω L ′
The RF Low-Loss Approximation
In practical amateur radio installations operating at HF, VHF, and UHF, high-quality feedlines use conductors with high electrical conductivity (copper or silver-plated copper) and low-loss dielectrics (polyethylene, foam, or air). At these operating frequencies, the reactive terms far exceed the loss terms: ω L ′ ≫ R ′ and ω C ′ ≫ G ′ \omega L' \gg R' \quad \text{and} \quad \omega C' \gg G' ω L ′ ≫ R ′ and ω C ′ ≫ G ′
Under this low-loss condition, R ′ R' R ′ and G ′ G' G ′ can be neglected in the impedance formula: Z 0 ≈ j ω L ′ j ω C ′ = L ′ C ′ Z_0 \approx \sqrt{\frac{j\omega L'}{j\omega C'}} = \sqrt{\frac{L'}{C'}} Z 0 ≈ jω C ′ jω L ′ = C ′ L ′
Important
This simplification reveals three critical physical principles of transmission lines:
At radio frequencies, the characteristic impedance of a low-loss transmission line is purely real (resistive) and exhibits zero net reactance ( Z 0 = R 0 + j 0 Z_0 = R_0 + j0 Z 0 = R 0 + j 0 ).
Characteristic impedance is entirely independent of line length ; a 1 -meter 1\text{-meter} 1 -meter section of 50 Ω 50\ \Omega 50 Ω coaxial cable exhibits the exact same Z 0 Z_0 Z 0 as a 1000 -meter 1000\text{-meter} 1000 -meter spool of the same cable.
Z 0 Z_0 Z 0 is governed exclusively by the physical geometry of the conductors and the dielectric properties of the insulating material separating them.
Physical Geometries and Geometric Impedance Formulas
Transmission lines in amateur radio fall into two primary physical categories: coaxial cables (unbalanced lines) and parallel open-wire / ladder lines (balanced lines).
1. Coaxial Cable Geometry
A coaxial cable consists of a central inner conductor of diameter d d d concentric with a cylindrical outer shielding conductor of inner diameter D D D , separated by a dielectric medium having relative permittivity ε r \varepsilon_r ε r (dielectric constant). Coaxial Cable Cross-Section
- /-------------\
- / Dielectric \
- | (ε_r) |
- | /-------\ |
- | | Center | |
- | | Conductor |
- | | (d) | |
- | \-------/ |
- | |
- \ Outer Shield /
- \-- (D) -------/
The distributed inductance and capacitance per unit length are: L ′ = μ 0 μ r 2 π ln ( D d ) ( H/m ) L' = \frac{\mu_0 \mu_r}{2\pi} \ln\left(\frac{D}{d}\right) \quad (\text{H/m}) L ′ = 2 π μ 0 μ r ln ( d D ) ( H/m ) C ′ = 2 π ε 0 ε r ln ( D / d ) ( F/m ) C' = \frac{2\pi \varepsilon_0 \varepsilon_r}{\ln(D/d)} \quad (\text{F/m}) C ′ = ln ( D / d ) 2 π ε 0 ε r ( F/m )
Substituting L ′ L' L ′ and C ′ C' C ′ into Z 0 = L ′ / C ′ Z_0 = \sqrt{L'/C'} Z 0 = L ′ / C ′ (assuming non-magnetic dielectric μ r = 1 \mu_r = 1 μ r = 1 ): Z 0 = 1 2 π μ 0 ε 0 ε r ln ( D d ) = 60 ε r ln ( D d ) = 138 ε r log 10 ( D d ) Z_0 = \frac{1}{2\pi} \sqrt{\frac{\mu_0}{\varepsilon_0 \varepsilon_r}} \ln\left(\frac{D}{d}\right) = \frac{60}{\sqrt{\varepsilon_r}} \ln\left(\frac{D}{d}\right) = \frac{138}{\sqrt{\varepsilon_r}} \log_{10}\left(\frac{D}{d}\right) Z 0 = 2 π 1 ε 0 ε r μ 0 ln ( d D ) = ε r 60 ln ( d D ) = ε r 138 lo g 10 ( d D )
where μ 0 / ε 0 ≈ 376.73 Ω \sqrt{\mu_0 / \varepsilon_0} \approx 376.73\ \Omega μ 0 / ε 0 ≈ 376.73 Ω is the intrinsic impedance of free space.
The Historical Origin of 50-Ohm and 75-Ohm Standards
Why did 50 Ω 50\ \Omega 50 Ω and 75 Ω 75\ \Omega 75 Ω become ubiquitous standards across RF systems?
Minimum Attenuation ( 77 Ω 77\ \Omega 77 Ω ): For an air-dielectric coaxial line, mathematical minimization of conductor skin loss yields an optimal diameter ratio of D / d ≈ 3.591 D/d \approx 3.591 D / d ≈ 3.591 . Substituting this ratio into the impedance formula gives Z 0 = 60 ln ( 3.591 ) ≈ 76.7 Ω Z_0 = 60 \ln(3.591) \approx 76.7\ \Omega Z 0 = 60 ln ( 3.591 ) ≈ 76.7 Ω . This was rounded to 75 Ω 75\ \Omega 75 Ω , which became the worldwide standard for low-loss receiving systems and telecommunications distribution (e.g., cable TV, RG-6, RG-11).
Maximum RF Power Handling ( 30 Ω 30\ \Omega 30 Ω ): In high-power transmitters, dielectric breakdown caused by peak electric field gradient ( E max E_{\text{max}} E max ) limits voltage capacity. Peak power handling is maximized when D / d = e ≈ 1.649 D/d = \sqrt{e} \approx 1.649 D / d = e ≈ 1.649 , yielding Z 0 = 60 ln ( 1.649 ) ≈ 29.9 Ω Z_0 = 60 \ln(1.649) \approx 29.9\ \Omega Z 0 = 60 ln ( 1.649 ) ≈ 29.9 Ω .
The 50-Ohm Compromise: In 1929, Bell Laboratories demonstrated that 50 Ω 50\ \Omega 50 Ω represents the ideal engineering compromise between the power-handling capability of 30 Ω 30\ \Omega 30 Ω and the low attenuation of 77 Ω 77\ \Omega 77 Ω . Furthermore, when solid polyethylene ( ε r ≈ 2.26 \varepsilon_r \approx 2.26 ε r ≈ 2.26 ) is used, the minimum loss ratio shifts downwards toward 52 Ω 52\ \Omega 52 Ω , firmly establishing 50 Ω 50\ \Omega 50 Ω as the universal standard for amateur transceivers, commercial two-way radios, and RF test equipment.
2. Parallel Two-Wire Line Geometry (Open-Wire and Twin-Lead)
A parallel two-wire line consists of two identical conductors of diameter d d d , separated center-to-center by spacing S S S , immersed in a dielectric medium of relative permittivity ε r \varepsilon_r ε r . Parallel Two-Wire Line Geometry
- <------- S ------->
- (•) (•)
- <-d-> <-d->
When the spacing is large compared to wire diameter ( S ≫ d S \gg d S ≫ d ): Z 0 = 120 ε r cosh − 1 ( S d ) ≈ 120 ε r ln ( 2 S d ) = 276 ε r log 10 ( 2 S d ) Z_0 = \frac{120}{\sqrt{\varepsilon_r}} \cosh^{-1}\left(\frac{S}{d}\right) \approx \frac{120}{\sqrt{\varepsilon_r}} \ln\left(\frac{2S}{d}\right) = \frac{276}{\sqrt{\varepsilon_r}} \log_{10}\left(\frac{2S}{d}\right) Z 0 = ε r 120 cosh − 1 ( d S ) ≈ ε r 120 ln ( d 2 S ) = ε r 276 lo g 10 ( d 2 S )
For an open-wire line suspended in air ( ε r ≈ 1.0 \varepsilon_r \approx 1.0 ε r ≈ 1.0 ), with wire diameter d = 2.0 mm d = 2.0\text{ mm} d = 2.0 mm and spacing S = 150 mm S = 150\text{ mm} S = 150 mm : Z 0 = 276 log 10 ( 2 × 150 2.0 ) = 276 log 10 ( 150 ) = 276 × 2.176 ≈ 600.6 Ω Z_0 = 276 \log_{10}\left(\frac{2 \times 150}{2.0}\right) = 276 \log_{10}(150) = 276 \times 2.176 \approx 600.6\ \Omega Z 0 = 276 lo g 10 ( 2.0 2 × 150 ) = 276 lo g 10 ( 150 ) = 276 × 2.176 ≈ 600.6 Ω
This explains why classic open-wire ladder lines built by radio amateurs naturally possess characteristic impedances of 450 to 600 Ω 450\text{ to }600\ \Omega 450 to 600 Ω .
Standard Amateur Radio Feedlines
Radio amateurs select transmission lines based on power rating, physical environment, mechanical flexibility, and acceptable attenuation across specific frequency bands.
- Feedline Family Typical Construction Nominal Impedance
- RG-58 Small flexible coax; useful for short runs 50 Ω 50\ \Omega 50 Ω
- RG-8X (Mini-8) Medium-size flexible coax, commonly foam insulated 50 Ω 50\ \Omega 50 Ω
- RG-213 Heavier flexible coax, commonly solid polyethylene insulated 50 Ω 50\ \Omega 50 Ω
- LMR-400 Foam-insulated coax with foil and braid shielding 50 Ω 50\ \Omega 50 Ω
- RG-6 and RG-11 Coax widely used in receiving/distribution systems 75 Ω 75\ \Omega 75 Ω
- Twin-lead Insulated parallel conductors Commonly 300 Ω 300\ \Omega 300 Ω
- Window line Parallel conductors in a slotted insulating web Commonly 450 Ω 450\ \Omega 450 Ω
- Open wire Wires held apart by spaced insulators Commonly 600 Ω 600\ \Omega 600 Ω ; set by geometry
Use the selected manufacturer's data sheet for velocity factor, attenuation at the operating frequency and allowable RF power. Average thermal power and peak voltage limits are different ratings. Observe the stated temperature, VSWR and installation conditions; connectors can impose a lower limit than the cable.
Velocity Factor ( V F VF V F ): Electrical vs. Physical Length
In a vacuum, electromagnetic waves propagate at the speed of light, c ≈ 2.9979 × 10 8 m/s c \approx 2.9979 \times 10^8\text{ m/s} c ≈ 2.9979 × 1 0 8 m/s (routinely approximated as 3.00 × 10 8 m/s 3.00 \times 10^8\text{ m/s} 3.00 × 1 0 8 m/s ). When an electromagnetic wave travels through a dielectric medium (insulator), its propagation velocity ( v v v ) slows down according to the relative permittivity ( ε r \varepsilon_r ε r ) of the material: v = c ε r v = \frac{c}{\sqrt{\varepsilon_r}} v = ε r c
The Velocity Factor ( V F VF V F ), also called the velocity of propagation, is the ratio of the phase velocity in the transmission line to the speed of light in vacuum: V F = v c = 1 ε r VF = \frac{v}{c} = \frac{1}{\sqrt{\varepsilon_r}} V F = c v = ε r 1
Because all practical dielectrics have a relative permittivity greater than unity ( ε r > 1.0 \varepsilon_r > 1.0 ε r > 1.0 ), the velocity factor is always less than 1.0 1.0 1.0 :
Air: ε r ≈ 1.0006 ⟹ V F ≈ 0.9997 \varepsilon_r\approx1.0006\implies VF\approx0.9997 ε r ≈ 1.0006 ⟹ V F ≈ 0.9997 , effectively 1 1 1 for ordinary calculations. Spacers and other dielectric supports can reduce a practical open-wire line's velocity factor.
Cellular (Foam) Polyethylene: ε r ≈ 1.38 − 1.64 ⟹ V F ≈ 0.78 − 0.85 \varepsilon_r \approx 1.38 - 1.64 \implies VF \approx 0.78 - 0.85 ε r ≈ 1.38 − 1.64 ⟹ V F ≈ 0.78 − 0.85
Polytetrafluoroethylene (PTFE / Teflon): ε r ≈ 2.05 ⟹ V F ≈ 0.70 \varepsilon_r \approx 2.05 \implies VF \approx 0.70 ε r ≈ 2.05 ⟹ V F ≈ 0.70
Solid Polyethylene (PE): ε r ≈ 2.26 ⟹ V F = 1 2.26 ≈ 0.66 \varepsilon_r \approx 2.26 \implies VF = \frac{1}{\sqrt{2.26}} \approx 0.66 ε r ≈ 2.26 ⟹ V F = 2.26 1 ≈ 0.66
Calculating Physical Length from Electrical Length
Because the wave travels slower in the cable, the wavelength within the transmission line ( λ line \lambda_{\text{line}} λ line ) is compressed compared to the free-space wavelength ( λ 0 \lambda_0 λ 0 ): λ line = v f = V F × c f = V F × λ 0 \lambda_{\text{line}} = \frac{v}{f} = \frac{VF \times c}{f} = VF \times \lambda_0 λ line = f v = f V F × c = V F × λ 0
Consequently, when cutting transmission lines for resonant stubs, phasing sections, or quarter-wave transformers, the physical length ( l phys l_{\text{phys}} l phys ) required to achieve a specific electrical fraction ( n n n ) of a wavelength is: l phys = n × λ line = n × V F × λ 0 = n × V F × ( c f ) l_{\text{phys}} = n \times \lambda_{\text{line}} = n \times VF \times \lambda_0 = n \times VF \times \left(\frac{c}{f}\right) l phys = n × λ line = n × V F × λ 0 = n × V F × ( f c )
Step-by-Step Worked Example: Quarter-Wave Matching Section
An amateur radio operator needs to construct a quarter-wave ( λ / 4 \lambda/4 λ /4 ) matching transformer for an antenna array operating at f = 144.20 MHz f = 144.20\text{ MHz} f = 144.20 MHz . Calculate the physical length required if using:
- Solid polyethylene coaxial cable ( V F = 0.66 VF = 0.66 V F = 0.66 )
- Gas-injected foam polyethylene cable ( V F = 0.85 VF = 0.85 V F = 0.85 )
- Open-wire line with a measured velocity factor of 0.98 0.98 0.98
Step 1: Compute the free-space wavelength ( λ 0 \lambda_0 λ 0 ): λ 0 = c f = 2.9979 × 10 8 m/s 144.20 × 10 6 Hz ≈ 2.0790 m \lambda_0 = \frac{c}{f} = \frac{2.9979 \times 10^8\text{ m/s}}{144.20 \times 10^6\text{ Hz}} \approx 2.0790\text{ m} λ 0 = f c = 144.20 × 1 0 6 Hz 2.9979 × 1 0 8 m/s ≈ 2.0790 m
The free-space quarter-wavelength is: λ 0 4 = 2.0790 m 4 ≈ 0.5197 m = 51.97 cm \frac{\lambda_0}{4} = \frac{2.0790\text{ m}}{4} \approx 0.5197\text{ m} = 51.97\text{ cm} 4 λ 0 = 4 2.0790 m ≈ 0.5197 m = 51.97 cm
Step 2: Apply the Velocity Factor for each cable type:
Solid PE ( V F = 0.66 VF = 0.66 V F = 0.66 ): l phys = 0.5197 m × 0.66 = 0.3430 m = 34.30 cm l_{\text{phys}} = 0.5197\text{ m} \times 0.66 = 0.3430\text{ m} = 34.30\text{ cm} l phys = 0.5197 m × 0.66 = 0.3430 m = 34.30 cm
Foam PE ( V F = 0.85 VF = 0.85 V F = 0.85 ): l phys = 0.5197 m × 0.85 = 0.4417 m = 44.17 cm l_{\text{phys}} = 0.5197\text{ m} \times 0.85 = 0.4417\text{ m} = 44.17\text{ cm} l phys = 0.5197 m × 0.85 = 0.4417 m = 44.17 cm
Open-wire line (specified V F = 0.98 VF=0.98 V F = 0.98 ): l phys = 0.5197 m × 0.98 = 0.5093 m = 50.93 cm l_{\text{phys}} = 0.5197\text{ m} \times 0.98 = 0.5093\text{ m} = 50.93\text{ cm} l phys = 0.5197 m × 0.98 = 0.5093 m = 50.93 cm
Caution
A quarter-wave section must be cut using its line wavelength. For the coax factors in this example, its physical length is 66 % 66\% 66% or 85 % 85\% 85% of a free-space quarter wavelength. Using the longer free-space length would put its quarter-wave frequency below the intended frequency.
Transmission Line Loss Mechanisms
Power entering a transmission line is not transferred with 100 % 100\% 100% efficiency. Power dissipation along the line occurs primarily through three distinct physical mechanisms:
1. Conductor Ohmic Losses ( I 2 R ′ I^2 R' I 2 R ′ )
Conductor loss results from the finite electrical conductivity ( σ \sigma σ ) of the metal conductors. As alternating current flows, electrical energy is converted into heat according to P loss = I 2 R ′ P_{\text{loss}} = I^2 R' P loss = I 2 R ′ . At radio frequencies, this loss is severely exacerbated by the skin effect .
Alternating current flowing through a conductor induces internal magnetic flux that opposes current flow in the center of the conductor. Consequently, the current density ( J J J ) concentrates exponentially in a thin annular layer at the outer periphery of the conductor. The skin depth ( δ \delta δ ), defined as the depth at which current density drops to 1 / e 1/e 1/ e ( ≈ 36.8 % \approx 36.8\% ≈ 36.8% ) of its surface value, is: δ = ρ π f μ = 1 π f μ σ \delta = \sqrt{\frac{\rho}{\pi f \mu}} = \sqrt{\frac{1}{\pi f \mu \sigma}} δ = π f μ ρ = π f μ σ 1
where ρ \rho ρ is electrical resistivity ( Ω ⋅ m \Omega\cdot\text{m} Ω ⋅ m ), μ \mu μ is magnetic permeability, and σ \sigma σ is electrical conductivity ( S/m \text{S/m} S/m ). For pure copper at 20 ∘ C 20^\circ\text{C} 2 0 ∘ C :
At f = 3.5 MHz f = 3.5\text{ MHz} f = 3.5 MHz (80m band): δ ≈ 35.1 μ m \delta \approx 35.1\ \mu\text{m} δ ≈ 35.1 μ m
At f = 14.0 MHz f = 14.0\text{ MHz} f = 14.0 MHz (20m band): δ ≈ 17.5 μ m \delta \approx 17.5\ \mu\text{m} δ ≈ 17.5 μ m
At f = 144 MHz f = 144\text{ MHz} f = 144 MHz (2m band): δ ≈ 5.48 μ m \delta \approx 5.48\ \mu\text{m} δ ≈ 5.48 μ m
At f = 432 MHz f = 432\text{ MHz} f = 432 MHz (70cm band): δ ≈ 3.16 μ m \delta \approx 3.16\ \mu\text{m} δ ≈ 3.16 μ m
Because the effective cross-sectional area through which RF current flows is restricted to this tiny skin layer, the effective RF resistance ( R RF R_{\text{RF}} R RF ) increases proportionally to the square root of frequency: R RF ∝ f R_{\text{RF}} \propto \sqrt{f} R RF ∝ f
Conductor attenuation ( α c \alpha_c α c ) in decibels per unit length therefore scales as: α c ∝ f d \alpha_c \propto \frac{\sqrt{f}}{d} α c ∝ d f
This explains why thin coaxial cables (such as RG-58, with center conductor diameter d ≈ 0.9 mm d \approx 0.9\text{ mm} d ≈ 0.9 mm ) exhibit dramatically higher attenuation than heavy cables (such as RG-213 with d ≈ 2.25 mm d \approx 2.25\text{ mm} d ≈ 2.25 mm or LMR-400 with d ≈ 2.74 mm d \approx 2.74\text{ mm} d ≈ 2.74 mm ).
2. Dielectric Losses ( V 2 G ′ V^2 G' V 2 G ′ )
Dielectric loss occurs when the alternating electric field between the conductors repeatedly realigns the molecular dipoles of the insulating material. The microscopic molecular friction converts electrical energy directly into thermal heat. Dielectric loss is governed by the material's dissipation factor or loss tangent ( tan δ \tan \delta tan δ ): α d ≈ 27.3 ε r f tan δ c ( dB/m ) \alpha_d\approx27.3\,\frac{\sqrt{\varepsilon_r}\,f\tan\delta}{c}\quad(\text{dB/m}) α d ≈ 27.3 c ε r f tan δ ( dB/m )
Note
For a low-loss, non-magnetic TEM line filled with a uniform dielectric, this expression follows from α d ≈ β tan δ / 2 \alpha_d\approx\beta\tan\delta/2 α d ≈ β tan δ /2 in Np/m and 1 Np = 8.686 dB 1\text{ Np}=8.686\text{ dB} 1 Np = 8.686 dB . With approximately constant loss tangent, dielectric loss scales with f f f , while conductor skin loss scales with f \sqrt f f . Their relative contributions depend on cable construction and material; there is no universal crossover frequency.
3. Radiation and Induction Losses
In balanced open-wire lines, radiation loss occurs if the conductor spacing ( S S S ) approaches an appreciable fraction of a wavelength ( S > 0.05 λ S > 0.05\lambda S > 0.05 λ ) or if current unbalance exists between the two wires. Coaxial shielding confines normal differential fields mostly inside the cable. Real shields and connectors have finite leakage, and common-mode current on the outside can also radiate.
Waveguides: Microwave Transmission Media
At frequencies above 1 to 2 GHz 1\text{ to }2\text{ GHz} 1 to 2 GHz , conventional coaxial cables face severe operational bottlenecks: skin-effect resistance on the tiny center conductor becomes enormous, dielectric dissipation causes heavy signal loss, and high RF voltages can cause dielectric breakdown. To overcome these limitations, microwave systems utilize waveguides . Rectangular Waveguide Geometry (TE_10 Mode)
- +--------------------------+
- /| /|
- / | / |
- +--------------------------+ |
- | | | |
- b | | | | b (Narrow Dimension)
- | | | |
- | +-----------------------|--+
- | / | /
- |/ |/
- +--------------------------+
- a (Broad Dimension)
A waveguide is a hollow, highly conductive metallic pipe—typically rectangular or circular in cross-section—that confines and directs electromagnetic waves through its enclosed dielectric (usually dry air or pressurized inert gas). Because waveguides possess no center conductor and use air dielectric, they exhibit neither center-conductor skin loss nor solid dielectric dissipation, achieving exceptionally low attenuation and multi-kilowatt power handling at microwave frequencies.
Modes of Propagation and Cutoff Frequency
Electromagnetic waves cannot propagate through a single hollow pipe in the Transverse Electro-Magnetic (TEM) mode that characterizes coaxial and two-wire lines. TEM propagation requires two electrically isolated conductors. Instead, waveguides support two families of propagation modes:
Transverse Electric ( T E m , n TE_{m,n} T E m , n or H m , n H_{m,n} H m , n Modes): The electric field ( E E E ) is everywhere purely transverse (perpendicular) to the direction of wave propagation along the guide ( E z = 0 E_z = 0 E z = 0 ), while a longitudinal magnetic field ( H z H_z H z ) exists.
Transverse Magnetic ( T M m , n TM_{m,n} T M m , n or E m , n E_{m,n} E m , n Modes): The magnetic field ( H H H ) is everywhere purely transverse ( H z = 0 H_z = 0 H z = 0 ), while a longitudinal electric field ( E z E_z E z ) exists.
The integers m m m and n n n represent the number of half-wave field variations across the broad dimension ( a a a ) and narrow dimension ( b b b ) respectively.
The Dominant T E 10 TE_{10} T E 10 Mode
In rectangular waveguides where a > b a > b a > b (typically a = 2 b a = 2b a = 2 b ), the mode possessing the lowest cutoff frequency is the T E 10 TE_{10} T E 10 mode , known as the dominant mode . For the T E 10 TE_{10} T E 10 mode, the cutoff wavelength ( λ c \lambda_c λ c ) and cutoff frequency ( f c f_c f c ) are: λ c = 2 a \lambda_c = 2a λ c = 2 a f c = c λ c = c 2 a f_c = \frac{c}{\lambda_c} = \frac{c}{2a} f c = λ c c = 2 a c
High-Pass Filter Behavior: The waveguide functions as an intrinsic high-pass filter. Signals with frequencies below the cutoff frequency ( f < f c f < f_c f < f c ) cannot propagate down the guide; they are attenuated exponentially as evanescent waves.
Operating Frequency Band: To ensure single-mode propagation and prevent multimode dispersion (where multiple modes propagate at different velocities, distorting signals), waveguides are operated within a recommended passband between 1.25 f c 1.25 f_c 1.25 f c and 1.90 f c 1.90 f_c 1.90 f c .
In amateur radio, standard rectangular waveguide designations include:
WR-90 (WG-16): Broad dimension a = 0.900 in = 22.86 mm a = 0.900\text{ in} = 22.86\text{ mm} a = 0.900 in = 22.86 mm . Cutoff frequency f c = 3.00 × 10 8 / ( 2 × 0.02286 ) ≈ 6.56 GHz f_c = 3.00 \times 10^8 / (2 \times 0.02286) \approx 6.56\text{ GHz} f c = 3.00 × 1 0 8 / ( 2 × 0.02286 ) ≈ 6.56 GHz . Designed for the 10.0 to 10.5 GHz 10.0\text{ to }10.5\text{ GHz} 10.0 to 10.5 GHz amateur microwave band.
WR-42 (WG-20): Broad dimension a = 0.420 in = 10.67 mm a = 0.420\text{ in} = 10.67\text{ mm} a = 0.420 in = 10.67 mm . Cutoff frequency f c ≈ 14.05 GHz f_c \approx 14.05\text{ GHz} f c ≈ 14.05 GHz . Designed for the 24 GHz 24\text{ GHz} 24 GHz amateur band.