1.1 Mathematics, Units and Metric Prefixes 1.2 DC Circuits, Voltage, Current, and Ohm's Law 1.3 Power, Energy, and Resistance Calculations 1.4 Resistor Colour Code and Component Symbol Identification 1.5 Capacitors: Construction, Ratings and Safety 1.6 Inductors: Construction, Factors Affecting Inductance and Combinations 1.7 Capacitor and Inductor Combination Calculations 1.8 AC Circuits, Frequency, Wavelength, and RMS Values 1.9 Reactance and Impedance in AC Circuits 1.10 Resonance, Q Factor and Tuned Circuits 1.11 Transformers: Turns Ratio, Impedance Matching and Eddy Currents 1.12 Rectifiers, PIV and Power Supply Smoothing 1.13 Active Components: Semiconductors, Diodes, and Transistors 1.14 Transistor and FET Symbols, Configurations and External Behaviour
2 Chapter 2: Transmitters and Receivers
2.1 Superheterodyne Receiver Architecture and Block Diagrams 2.2 Frequency Converters, IF Amplifiers and Transceiver Sharing 2.3 Receiver Performance: Sensitivity, Selectivity, and AGC 2.4 Signal-to-Noise Ratio and Receiver Noise Performance 2.5 Transmitter Architecture, Oscillators and Frequency Synthesisers 2.6 Transmission Quality: Frequency Drift, Parasitic Oscillation and Over-Modulation 2.7 Modulation Techniques: AM, FM, and SSB 2.8 Amplifier Classes and Power Amplifiers (Class A, B, C, and AB) 2.9 Modulation, Duty Cycle and Rated Transmitter Power 2.10 Transceiver Control: ALC, Squelch, and Digital Modes 2.11 Digital Transmission Modes and Bandwidth
3 Chapter 3: Transmission Lines and Antennas
3.1 Transmission Lines: Coaxial, Twin-Lead, and Characteristic Impedance 3.2 Standing Wave Ratio (SWR) and Reflection Loss 3.3 Impedance Matching, Baluns, and Antenna Tuning Units (ATUs) 3.4 Resonant Antennas: Dipoles, Verticals, and End-Fed Antennas 3.5 Angle of Radiation, Antenna Height and Current Distribution 3.6 Directional Antennas: Yagis, Gain and Radiation Patterns 3.7 Effective Radiated Power: System Gains and Losses
4 Chapter 4: Radio Wave Propagation
4.1 Electromagnetic Waves: Velocity, Wavelength and Polarisation 4.2 Ground Wave, Direct Wave and Line-of-Sight Propagation 4.3 Ionospheric Layers (D, E, F1, F2) and Skywave Propagation 4.4 Critical Frequency, Maximum Usable Frequency (MUF), and Fading 4.5 Solar Activity, Sunspot Cycles, and VHF Anomalous Propagation 4.6 Seasonal and Diurnal Effects on Band Selection
5 Chapter 5: Electrical and RF Measurements
5.1 Multimeter Operation: Voltage, Current, and Resistance Measurements 5.2 RF Power and SWR Measurement (PEP vs. Average Power) 5.3 Frequency Counters, Dummy Loads, and Test Equipment 5.4 Frequency Standards, Crystal Calibrators and Standard-Frequency Transmissions
6 Chapter 6: Interference and Electromagnetic Compatibility (EMC)
6.1 Harmonic Emissions, Spurious Signals, and Transmitter Filtering 6.2 How Interference Enters Television and Broadcast Receivers 6.3 Masthead Amplifier Overload and Audio-Stage Demodulation 6.4 Electromagnetic Interference (EMI), Breakthrough, Ferrites, and EMC 6.5 Filter Types, Response Curves and EMC Filter Selection 6.6 EMC Good Practice: Minimum Power, Balanced Antennas and Feedline Routing 6.7 Vehicle EMC and Resolving Community Interference Complaints
7 Chapter 7: Safety and Environmental Hazards
7.1 Mains Voltage Safety, Earthing, and High-Voltage Capacitors 7.2 Equipment Approval, Mains Wiring and Fuse Practice 7.3 Station Layout, Cabling and Emergency Shut-Off 7.4 Lightning Protection and Station Security 7.5 Electric Shock: Prevention, Rescue and Emergency Response 7.6 Battery, Chemical and Hearing Safety in the Amateur Station 7.7 RF Exposure: EMR Hazards and Safe Distance 7.8 Antenna Erection, Siting and Power Line Safety
1.5 Capacitors: Construction, Ratings and Safety
Key Takeaways Explain This Topic AI
The farad is defined as one coulomb of stored charge per volt applied, and practical station parts are labelled in picofarads, nanofarads or microfarads.
Capacitance rises with plate area, falls as plate separation increases, and rises with the permittivity of the dielectric between the plates.
A working-voltage rating must exceed the peak of the applied waveform, and 230 V RMS Australian mains peaks at 1.414 x 230 = 325 V.
Electrolytic and tantalum capacitors are polarised because their dielectric is a thin oxide layer; reversed, they heat, gas and burst their vent.
Stored energy is half C V squared, so a 100 uF reservoir at 450 V holds about 10 joules and can stay lethal for hours after the plug is pulled.
Last updated: July 2026
1.5 Capacitors: Construction, Ratings and Safety
ACMA Exam Focus: Syllabus items 4.9, 4.10 and 4.11 — recall the farad and the two-conductors-and-an-insulator construction, state how plate area, plate separation and the dielectric change the value, explain breakdown voltage and polarised capacitors, and describe the danger of the charge a capacitor still holds after switch-off.
The farad and the units you will actually meet
Capacitance is the ability of a component to store electric charge. It is defined by C = Q V C = \frac{Q}{V} C = V Q
where Q Q Q is the stored charge in coulombs and V V V is the voltage across the component. The unit is the farad (F) , named after Michael Faraday: a capacitor of one farad holds one coulomb of charge for every volt applied to it.
One farad is an enormous amount of capacitance, so almost every part in a VK station is labelled in a sub-multiple.
- Sub-multiple Value in farads Where you meet it
- picofarad (pF) 10 − 12 10^{-12} 1 0 − 12 F VFO tuning, receiver front ends, trimmers, feedthrough capacitors
- nanofarad (nF) 10 − 9 10^{-9} 1 0 − 9 F RF bypass and decoupling, audio filters, timing networks
- microfarad (µF) 10 − 6 10^{-6} 1 0 − 6 F audio coupling, power-supply reservoir and smoothing capacitors
Learn the ladder in both directions: 1 µF = 1000 nF = 1 000 000 pF. Older circuit diagrams and surplus gear label microfarads mfd and picofarads mmfd .
What a capacitor is made of
Every capacitor is two conducting surfaces (the plates) separated by an insulator (the dielectric) . Connect a voltage source and electrons are pushed onto one plate and pulled off the other until the resulting charge imbalance produces a voltage equal to the source. The energy is stored in the electric field in the dielectric, not in the metal.
Because the plates never touch, a capacitor blocks direct current while still passing alternating current — the plates simply charge and discharge in step with the applied waveform. That one property explains most of its uses in a transceiver: coupling audio between stages without passing the DC bias along with it, bypassing RF to chassis while leaving a supply rail intact, and setting the frequency of a tuned circuit.
The three factors that set the value
- Change made Capacitance Why
- Larger plate area rises, in direct proportion more conducting surface is available to hold charge
- Wider plate separation falls, inversely the field between the plates weakens as the gap grows
Higher-permittivity dielectric rises the dielectric polarises and partly cancels the internal field, so more charge fits at the same voltage
Written together, C ∝ ε r A / d C \propto \varepsilon_r A / d C ∝ ε r A / d . The examination asks for the direction of each effect rather than the arithmetic: increase the area or the permittivity and you gain capacitance, increase the spacing and you lose it. A variable capacitor demonstrates the first two directly — rotating the moving vanes out of mesh reduces the overlapping area and therefore the capacitance, while transmitting types use wide plate spacing so they can survive high RF voltages.
Common dielectrics in a station
Ceramic — 1 pF to about 1 µF, non-polarised; the standard RF bypass and decoupling part.
Silvered mica — 1 pF to about 10 nF; very stable and low loss, used in VFOs and power-amplifier tank circuits.
Polyester and polypropylene film — 1 nF to about 10 µF; audio coupling, timing and snubber duty.
Aluminium electrolytic — 1 µF to 10 000 µF and beyond, polarised ; power-supply reservoirs, useless at RF.
Tantalum — 0.1 µF to about 100 µF, polarised ; compact low-voltage decoupling on logic boards.
Air-spaced variable — a few pF to a few hundred pF; tuning, and the valve-era antenna tuning unit.
Breakdown voltage and working voltage (item 4.10)
Every capacitor carries a DC working voltage (WVDC) rating. Exceed it and the dielectric suffers breakdown : the insulator is punctured, the part becomes a short circuit or fails in a puff of smoke, and whatever it was serving usually goes with it.
The trap the examiners set is the difference between root-mean-square and peak. A capacitor charges towards the peak of the applied waveform, and for a sine wave the peak is 1.414 times the RMS value.
Worked example — a mains-derived rail. Australian mains is 230 V RMS at 50 Hz. Rectified straight into a reservoir capacitor, the peak is V p e a k = 1.414 × 230 = 325 V V_{peak} = 1.414 \times 230 = 325\ \text{V} V p e ak = 1.414 × 230 = 325 V
so a 250 V part, and even a 350 V part, is unsafe here. Fit a 400 V or 450 V capacitor and you have headroom for mains surges and for the higher voltage present at no load. The same trap appears at radio frequencies in a different guise: the RF voltage swinging across a transmitter tank circuit can be several times the DC supply rail, which is why tank capacitors have widely spaced plates.
Polarised capacitors (item 4.10)
Aluminium electrolytic and tantalum capacitors achieve their very high capacitance per unit volume because their dielectric is an extremely thin oxide layer, formed electrochemically on the anode foil. That oxide survives only while the applied voltage keeps the correct polarity, so these parts are polarised and must be connected the right way round.
Can-type electrolytics carry a printed stripe filled with minus signs down the negative side; radial types have a longer positive lead .
Connect one backwards and the oxide degrades, leakage current rises sharply, the electrolyte heats and boils, and pressure bursts the scored vent — noisily, and with hot electrolyte.
Never place a plain electrolytic directly across an AC source, where the polarity reverses every half-cycle. Use a bipolar (non-polarised) electrolytic or a film capacitor instead.
- Stored charge is the real hazard (item 4.11)
- The energy held in a charged capacitor is E = 1 2 C V 2 E = \tfrac{1}{2}CV^2 E = 2 1 C V 2
in joules, with C C C in farads and V V V in volts. Energy rises with the square of the voltage, so doubling the voltage quadruples the stored energy.
Worked example. A linear amplifier supply uses a 100 µF reservoir charged to 450 V: E = 0.5 × ( 100 × 10 − 6 ) × 450 2 = 0.5 × 0.0001 × 202 500 ≈ 10.1 J E = 0.5 \times (100 \times 10^{-6}) \times 450^2 = 0.5 \times 0.0001 \times 202\,500 \approx 10.1\ \text{J} E = 0.5 × ( 100 × 1 0 − 6 ) × 45 0 2 = 0.5 × 0.0001 × 202 500 ≈ 10.1 J
The danger is not the number by itself. It is that the capacitor still holds that charge after the equipment is switched off and unplugged . With no discharge path the terminals can sit near full voltage hours later, and even a shock that is not directly fatal triggers an involuntary muscular reaction, so the fall or the secondary contact does the damage.
The controls are simple, and they are examinable:
Bleeder resistor — a high-value resistor of adequate power and voltage rating, permanently connected across the reservoir and sized to discharge it within a set time after switch-off. It can fail open with no outward sign, so it is never the only safeguard.
Shorting stick — an insulated rod carrying a suitably rated resistor, typically a few hundred ohms to a few kilohms, with a heavy lead to chassis earth. The resistor limits the peak current so the discharge is controlled rather than explosive.
Verify, then link — measure zero volts, then clip a shorting link across the terminals and leave it in place while you work, because a capacitor can recover some voltage through dielectric absorption.
Order of work — switch off, unplug, wait, discharge with the stick, verify with a meter, fit the link. Keep one hand in your pocket so that no current path crosses your chest.
Capacitors are rarely used one at a time. The rules for finding the value of a series, parallel or series-parallel group are dealt with in the next section, alongside the matching rules for inductors.