Study guide
7.3 Battery Types, Specifications and Dangerous Goods
CASA Remote Pilot Licence RePL
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 About the RePL Exam 1.2 How to Use This Guide & Build a Study Plan
2 RPA Air Law: Regulatory Framework & Standard Operating Conditions
2.1 CASR Part 101 and the Manual of Standards 2.2 Standard Operating Conditions (SOC) 2.3 The 120 m (400 ft) AGL Height Limit 2.4 VLOS, Daylight, Visibility and the One-RPA Rule
3 RPA Air Law: Licensing, Categories & Approvals
3.1 RePL vs ReOC: Pilot Licence vs Operator Certificate 3.2 Excluded Categories and Operator Accreditation 3.3 RPA Weight Categories and Registration 3.4 Operating Beyond the SOC: Approvals and the ReB1
4 Basic Aviation Knowledge (RBAK)
4.1 Direction, Wind Velocity and Aviation Time 4.2 Units of Measurement: Height, Altitude and Elevation 4.3 Aerodynamics: Lift, Drag, Thrust, Weight and Energy 4.4 Weight and Balance: Terms and Limits 4.5 Propellers and Rotors 4.6 Axes, Attitude and Flight Control Principles 4.7 The Remote Pilot Station
5 RPAS Systems: Platforms, C2 Link & Power
5.1 Multirotor vs Fixed-Wing Characteristics 5.2 Command-and-Control Link and Failsafes 5.3 Lithium-Polymer Battery Management and Safety
6 RPAS Systems: Sensors, Payload & Preflight
6.1 GNSS, Compass, IMU and Geofencing 6.2 Payload, Centre of Gravity and Pre-Flight Checks 6.3 Automated Flight Management Systems (RAFM)
7 Electrical & Electronic Systems (REES)
7.1 Electrical Terms and RPAS Electrical Components 7.2 Electric Motors, Kv and Current Draw 7.3 Battery Types, Specifications and Dangerous Goods 7.4 Charging, Discharging, Balancing and Battery Limitations 7.5 Radio Waves, Frequency Bands and Propagation 7.6 GPS Components, Errors and Electromagnetic Hazards
8 Multirotor Aerodynamics & Performance (RBKM)
8.1 Multirotor Airframe and Component Layout 8.2 Rotor Aerodynamics: Blade Design, Thrust, Drag and Torque 8.3 Hovering: Ground Effect, Recirculation and Translational Lift 8.4 Multirotor Flight Controls, Stabilisation and GPS Hold 8.5 Motor Failure, Rotor Direction and Abnormal Aerodynamics 8.6 Weight, Power, Wind and Climb Performance 8.7 Descent, Vortex Ring State and Landing
9 Navigation & Charts
9.1 Chart Fundamentals: Latitude, Longitude, Variation and Distance 9.2 Visual Terminal Charts and Visual Navigation Charts 9.3 Airspace Classes, Control Zones and CTA Steps 9.4 Restricted, Danger and Prohibited Areas and Obstacles 9.5 NOTAMs, the AIP and Chart Currency
10 Meteorology
10.1 Wind, Sea Breezes and Local Effects 10.2 Turbulence, Orographic Effects and Terrain 10.3 Thunderstorms, Fronts and Fog 10.4 Density Altitude, METAR/TAF and BoM Forecasts 10.5 Weather Observations: Reading the Sky and the Site
11 Human Factors
11.1 IMSAFE, Fatigue and Complacency 11.2 Situational Awareness, Fixation and External Pressure 11.3 Alcohol, Drugs and Crew Resource Management 11.4 Vision, Visual Limitations and Illusions 11.5 Stress and Stress Management 11.6 Threat and Error Management
12 Radio & AROC
12.1 Phonetic Alphabet, Phraseology and CTAF 12.2 The 121.5 MHz Emergency Frequency, Transponder Codes and the AROC
13 Risk & Operational Procedures
13.1 Job Safety Assessment, Risk Assessment and the Hierarchy of Controls 13.2 Site Survey, Bystander Management, Emergencies and Giving Way
14 Operations, Airworthiness & Reporting (RKOP)
14.1 Remote Pilot Responsibilities, Crew Briefing and Ground Operations 14.2 Operational, Remote Pilot and Technical Logs 14.3 Airworthiness, Serviceability and Defect Reporting 14.4 Role Equipment, Sensors and Payload Implications 14.5 Accident and Incident Reporting to the ATSB 14.6 Abnormal Operations, Fail-Safes and Flight Termination 14.7 Operating Near Aerodromes and Above 400 ft AGL
7.3 Battery Types, Specifications and Dangerous Goods
Key Takeaways Explain This Topic AI
Schedule 4 names five energy sources: nickel metal hydride, lithium polymer, alkaline, nickel cadmium and fuel cells; LiPo dominates RPAS because of its energy density and discharge rate.
A pack label decodes as cell count in series (S), cells in parallel (P), capacity in mAh or Ah, and a continuous C-rating with a separate burst rating.
Cells in series add voltage at the same capacity; cells in parallel add capacity at the same voltage.
Lithium batteries are classified dangerous goods for air transport, so airline carriage rules on watt-hours, terminal protection and carry-on carriage apply.
Last updated: August 2026
The Five Energy Sources Schedule 4 Names
Most RPA candidates only ever handle lithium polymer packs, but the syllabus asks about five chemistries and expects you to know why LiPo won.
Type Nominal cell voltage Energy density RPAS relevance
Lithium polymer (LiPo) 3.7 V Very high The dominant RPA flight battery: high energy density and very high discharge rate
- Nickel metal hydride (NiMH) 1.2 V Moderate Ground equipment, older transmitters; robust and tolerant but heavy
- Nickel cadmium (NiCd) 1.2 V Low Largely obsolete; suffers memory effect and contains cadmium
Alkaline 1.5 V Moderate but non-rechargeable Primary cells for small ground accessories only; cannot supply high current
Fuel cell Varies by stack Very high (by mass) Emerging long-endurance RPA technology; converts hydrogen to electricity with water as the by-product
A related chemistry worth knowing is lithium-ion (Li-ion) , used in "smart battery" packs on many commercial airframes. It has higher energy density than LiPo per unit mass but a lower maximum discharge rate, so it suits endurance-focused aircraft rather than high-thrust ones.
Decoding a Pack Label
A typical label reads something like: 6S1P 22.2 V 16,000 mAh 15C / 30C burst .
- Element Meaning
- 6S Six cells in series . Nominal voltage = 6 × 3.7 = 22.2 V; fully charged = 6 × 4.2 = 25.2 V
- 1P One set of cells in parallel . A 6S2P pack has two parallel strings, doubling capacity
- 22.2 V Nominal pack voltage (the number quoted in specifications)
- 16,000 mAh Capacity — 16 amp-hours. The pack can theoretically deliver 16 A for one hour
- 15C Continuous C-rating — maximum sustained discharge = 15 × 16 A = 240 A
- 30C burst Maximum burst C-rating — brief peaks only, a few seconds at most
- Series and parallel
Series (S) : voltage adds, capacity stays the same. Two 3S 5,000 mAh packs in series give 6S 5,000 mAh.
Parallel (P) : capacity adds, voltage stays the same. Two 3S 5,000 mAh packs in parallel give 3S 10,000 mAh.
Both increase the total energy stored, but they do so in different ways. Series raises the voltage the motors see, which raises rpm for a given Kv. Parallel raises the current the pack can supply and the run time, without changing rpm. Substituting a 6S pack into an airframe designed for 4S can destroy ESCs rated for the lower voltage — always check the cell count, not just the physical fit.
The Two Plugs
Every multi-cell RPA pack has two connectors and Schedule 4 names both:
The main power plug — the heavy connector (XT60, XT90, AS150, EC5 and similar) carrying the full discharge current to the aircraft.
The balance plug — a small multi-pin connector with one wire per cell junction, letting a charger or cell checker read and equalise each cell individually .
The balance plug is the safety-critical one. Without it, a charger can only see total pack voltage; a pack reading a healthy 25.2 V could contain one cell at 4.4 V (over-charged, a fire risk) and another at 4.0 V, and the charger would never know. Always charge through the balance lead, and always check individual cell voltages before flight.
State of Charge and Cell Health
Cell voltage is the practical proxy for state of charge on a LiPo:
- Per-cell voltage State Action
- 4.20 V Fully charged Ready to fly; do not exceed
- ~3.85 V Storage level Charge before flight
- 3.70 V Nominal Mid-flight
- 3.5–3.6 V Low warning Land promptly
- Below ~3.0 V Over-discharged Cell damaged; capacity permanently lost
A cell checker is a small device that plugs into the balance lead and reads each cell. It is the fastest pre-flight battery check there is, and the single most useful $20 item in a drone bag. The pass criterion is not just "all cells above 4.1 V" but all cells within about 0.05 V of each other . A pack with one cell 0.1 V or more adrift is unbalanced or has an internal fault and should be grounded.
Beyond voltage, serviceability is judged by:
Physical condition — any swelling, puffiness, or a soft spot means retire the pack immediately.
Internal resistance , if your charger measures it. Rising internal resistance is the clearest early indicator of a pack approaching end of life, and it shows in flight as increasing voltage sag.
Cycle count — many smart packs log this. Manufacturers typically publish a useful life of a few hundred cycles.
Temperature after flight — a pack that is hot rather than warm has been worked beyond its comfortable current.
Batteries as Dangerous Goods
Schedule 4 topic 4(d) asks specifically about batteries classified as dangerous goods for air transportation , and this is a real operational issue for any remote pilot who flies to a job.
Lithium batteries are Class 9 dangerous goods . The governing measure is watt-hours (Wh) : Wh = Voltage (V) × Capacity (Ah) \text{Wh} = \text{Voltage (V)} \times \text{Capacity (Ah)} Wh = Voltage (V) × Capacity (Ah)
Worked example. A 6S 16,000 mAh pack is 22.2 V × 16 Ah = 355 Wh — far above the limits most airlines apply to passenger carriage, and typically requiring freight arrangements as declared dangerous goods. A 4S 5,000 mAh pack is 14.8 × 5 = 74 Wh , which falls in the band that many airlines permit in carry-on baggage with prior approval.
The rules that apply almost universally:
Carry-on only. Spare lithium batteries must travel in the cabin, never in checked baggage, because a fire in the hold cannot be fought.
Terminal protection. Tape the terminals or carry each pack in its own bag or fire-resistant pouch so nothing can short across them.
Quantity limits and approval thresholds vary by airline and by watt-hour band. Check with the specific carrier before you travel.
Charge state. Many carriers require spares to be transported at or near storage charge rather than fully charged.
Road transport within Australia is less regulated for small quantities but the same physics applies: terminals insulated, packs in fire-resistant containers, secured so they cannot move, and out of direct sun. A pack left on a car dashboard on a 40-degree day is a genuine fire risk, and it is also a pack you should retire afterwards even if it looks intact.