Study guide

9.2 Filler Metal F-Numbers and As-Deposited Chemistry A-Numbers

AWS ASME BPVC Section IX + B31.1/B31.3 Endorsement CWI/SCWI

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Exam Structure, Logistics & Code Navigation Strategy

1.1 Credential Overview, Prometric Delivery & July 2025 Hard-Copy Rule 1.2 The Three-Code Triad: Section IX, B31.1, and B31.3 Roles & Interrelationships 1.3 Rapid Code-Book Navigation: Tabbing, Cross-Referencing & Time Management

2 Chapter 2: Section IX Article I — General Welding Requirements

2.1 Scope, Responsibilities & Section IX Architecture 2.2 Mechanical Test Types, Specimen Dimensions & Acceptance Criteria 2.3 Notch-Toughness Tests, Fillet-Weld Tests & Special Examinations

3 Chapter 3: Section IX Article II — Procedure Qualification Fundamentals

3.1 PQR vs. WPS Workflow, Purpose & Content Requirements 3.2 Coupling and Supporting Multiple WPSs and PQRs 3.3 Test Coupons, Preparation & Required Test Specimen Allocations

4 Chapter 4: Section IX Procedure Qualification Limits & Thickness Rules

4.1 Base Metal & Deposited Weld Metal Thickness Limits 4.2 Impact Testing Requirements & Toughness Thickness Qualification Ranges 4.3 Fillet Weld Procedure Qualification Rules & Special Applications

5 Chapter 5: Section IX Article III — Welder Performance Qualification Fundamentals

5.1 Welder & Welding Operator Qualification Intent, Responsibilities & Identification 5.2 Qualification Testing Methods: Mechanical Bend Tests vs. Volumetric NDE 5.3 Welder Qualification Continuity, Expiration, and Requalification

6 Chapter 6: Section IX Welder Performance Limits, Positions & Diameters

6.1 Test Positions, Groove Weld Orientations & Production Position Limits 6.2 Welder Thickness Limits and Pipe Diameter Qualification Ranges 6.3 Welder Essential Variables: F-Numbers, Backing, and Process Transfers

7 Chapter 7: Section IX Article IV — Welding Variables by Process (Part 1: SMAW & GTAW)

7.1 Understanding Essential, Supplementary Essential & Nonessential Variables 7.2 Shielded Metal Arc Welding (SMAW) Procedure Variables 7.3 Gas Tungsten Arc Welding (GTAW) Procedure Variables

8 Chapter 8: Section IX Article IV — Welding Variables by Process (Part 2: GMAW/FCAW & SAW)

8.1 GMAW & FCAW Procedure Variables and Short-Circuiting Transfer Rules 8.2 Submerged Arc Welding (SAW) Procedure Variables and Flux-Wire Combinations 8.3 Special Variables: Heat Input, Electrical Characteristics & Shielding Gases

9 Chapter 9: Section IX Material Classifications, Numbers & Standard Documentation

9.1 Base Metal P-Numbers, Group Numbers, and S-Numbers 9.2 Filler Metal F-Numbers and As-Deposited Chemistry A-Numbers 9.3 ASME Standard Documentation: Auditing WPS, PQR, and WPQ Forms

10 Chapter 10: ASME B31.1 Power Piping — Scope, Materials, Design & Welding Fabrication

10.1 B31.1 Scope, Jurisdiction, Boiler External Piping vs. Non-Boiler External Piping 10.2 B31.1 Welding Requirements, Joint Alignment, Backing Rings & Tack Welds 10.3 B31.1 Welder & Procedure Qualification Interfacing with Section IX 10.4 B31.1 Materials, Design Conditions & Pressure Design of Components

11 Chapter 11: ASME B31.1 Power Piping — Heat Treatment, Examination, Testing & Fabrication Records

11.1 B31.1 Preheat Rules & Mandatory Temperatures 11.2 B31.1 Postweld Heat Treatment (PWHT) Rules, Temperatures & Holding Times 11.3 B31.1 Mandatory NDE Examination, Acceptance Standards & Pressure Leak Tests 11.4 B31.1 Bending, Forming, Assembly & Code Records

12 Chapter 12: ASME B31.3 Process Piping — Scope, Fluid Services, Materials, Design & Welding

12.1 B31.3 Scope, Fluid Service Classifications & Owner Responsibilities 12.2 B31.3 Welding, Joint Preparation, Backing Rings & Fabrication Details 12.3 B31.3 Procedure & Performance Qualification Rules and Section IX Exceptions 12.4 B31.3 Materials, Design Conditions & Pressure Design of Components

13 Chapter 13: ASME B31.3 Process Piping — Heat Treatment, Examination, Testing, Fabrication & Records

13.1 B31.3 Preheat and Postweld Heat Treatment Rules & Tables 13.2 B31.3 Inspection vs. Examination Responsibilities & Examination Extents 13.3 B31.3 Acceptance Criteria for Weld Imperfections 13.4 B31.3 Pressure Leak Testing: Hydrostatic, Pneumatic & Sensitive Leak Tests 13.5 B31.3 Bending, Forming, Assembly & Records

9.2 Filler Metal F-Numbers and As-Deposited Chemistry A-Numbers

Key Takeaways Explain This Topic AI

Filler metal F-Numbers (Table QW-432) group welding electrodes and rods based on usability characteristics, essentially reflecting the manual dexterity required of a welder to make sound deposits.

In procedure qualification (QW-404.4), changing from one F-Number to any other F-Number is an essential variable requiring complete requalification, with zero cross-qualification between F-Numbers.

In welder performance qualification (Table QW-433), qualifying with an F-No. 4 electrode with backing qualifies the welder to deposit F-No. 1, F-No. 2, F-No. 3, and F-No. 4 electrodes with backing in production.

Table QW-442 A-Numbers categorize ferrous weld metal deposits into 12 groups based on as-deposited chemical composition; A-Numbers apply strictly to ferrous metals and do not apply to nonferrous alloys.

Under paragraph QW-404.5, a change in weld deposit A-Number is an essential variable for procedure qualification, but A-Numbers are never an essential variable for welder performance qualification.

Last updated: September 2026

9.2 Filler Metal F-Numbers and As-Deposited Chemistry A-Numbers

Core Principle: In ASME Section IX, filler metals are governed by two distinct classification systems that serve entirely different engineering functions: F-Numbers (Table QW-432) classify electrodes by operator handling and usability characteristics, whereas A-Numbers (Table QW-442) classify ferrous weld deposits by their final as-deposited chemical composition. An inspector must never confuse usability (how an electrode runs) with metallurgy (the chemical composition of the deposited weld metal).

1. Engineering Basis of Table QW-432 F-Numbers

Under paragraph QW-430 , filler metals are assigned F-Numbers to reduce the number of welding procedure and welder performance qualifications. The fundamental basis of F-Number assignment is usability characteristics —the operational behavior of the flux coating, slag viscosity, arc force, wetting characteristics, and operator dexterity required to deposit sound weld metal in various positions.

Table QW-432 organizes filler metals across ASME Section II Part C (SFA specifications) into distinct F-Number categories. For steel welding, the first six F-Numbers represent the cornerstone of the qualification system. +-----------------------------------------------------------------------------------------+

  • | THE STEEL SMAW COATING SPECTRUM (F-1 THROUGH F-4) |
  • +-----------------------------------------------------------------------------------------+
  • | F-No. 1 | Heavy Rutile / Iron Powder | High deposition, thick slag, flat/horizontal |
  • | F-No. 2 | Titania / Rutile | Medium penetration, smooth arc, sheet metal |
  • | F-No. 3 | Cellulosic | Deep penetration, fast freezing, high arc force |
  • | F-No. 4 | Low-Hydrogen Basic | Clean weld metal, high impact toughness, crack-resistant|
  • +-----------------------------------------------------------------------------------------+
  • 2. In-Depth Breakdown of Steel and Alloy F-Numbers

F-Number SFA Specifications & AWS Classifications Flux Coating / Core Characteristics Industrial Applications & Pointers

F-No. 1 SFA-5.1 & SFA-5.5: EXX20, EXX24, EXX27, EXX28 Heavy rutile or iron oxide coating containing up to 50% iron powder; creates large fluid puddle with heavy slag cover. Restricted to flat position and horizontal fillet welds. High deposition rates for heavy structural joints and tank bottoms.

F-No. 2 SFA-5.1 & SFA-5.5: EXX12, EXX13, EXX14, EXX19 Titania (rutile) coating with potassium or sodium silicate binders; soft, stable arc with moderate penetration and light spatter. General sheet metal fabrication, non-code light structural steel, automotive bodywork; poor low-temperature toughness.

F-No. 3 SFA-5.1 & SFA-5.5: EXX10, EXX11 (e.g., E6010, E7010-P1, E6011) High cellulose coating (up to 30% wood pulp); burns in the arc to generate large volumes of CO and H2 gas, creating forceful, digging penetration. The pipeline welder's staple. Used worldwide for open-root downhill cross-country pipe welding; high hydrogen content requires strict preheat.

F-No. 4 SFA-5.1 & SFA-5.5: EXX15, EXX16, EXX18, EXX18M, EXX28, EXX48 Basic mineral coating containing calcium carbonate (limestone) and calcium fluoride (fluorspar); produces low-hydrogen weld metal (< 4–8 mL/100g). Mandatory for pressure vessels, nuclear piping, and heavy structural joints. Resists hydrogen cold cracking; requires strict storage ovens (250°F+).

F-No. 5 SFA-5.4: Covered austenitic and duplex stainless electrodes (e.g., E308, E308L, E309, E316, E316L, E347, E2209) Lime-basic or rutile-titania flux coatings formulated for high-alloy stainless cores. Joining austenitic, martensitic, and duplex stainless steels. High operator dexterity needed to manage sluggish puddle flow.

F-No. 6 SFA-5.9, 5.17, 5.18, 5.20, 5.22, 5.23, 5.25, 5.26, 5.28, 5.29, 5.36 Bare solid wire, composite metal-cored wire, flux-cored wire, and GTAW cut rods for carbon, low-alloy, and stainless steels across all processes. Encompasses all continuous wire and rod processes: GTAW (ER70S-6, ER308L), GMAW (ER70S-3), FCAW (E71T-1M, E71T-8), and SAW (F7A2-EM12K).

Nonferrous and Specialty F-Numbers

Beyond the steel classifications, Table QW-432 assigns specialized blocks for nonferrous alloys:

F-No. 21 through F-No. 25: Aluminum and aluminum-base alloys (SFA-5.10, e.g., ER4043, ER5356).

F-No. 31 through F-No. 37: Copper and copper-base alloys (SFA-5.6, SFA-5.7, SFA-5.8).

F-No. 41 through F-No. 46: Nickel and nickel-base alloys (SFA-5.11 covered electrodes, SFA-5.14 bare wire). Notably, F-No. 43 encompasses the premier nickel-chromium welding alloys: Alloy 625 (ERNiCrMo-3 / ENiCrMo-3) and Alloy 82 (ERNiCr-3) .

F-No. 51 through F-No. 56: Titanium and titanium-base alloys.

F-No. 61: Zirconium and zirconium-base alloys.

F-No. 71 through F-No. 72: Hard-facing weld metal overlay alloys.

3. Procedure Qualification vs. Welder Qualification Rules for F-Numbers

One of the greatest points of divergence in ASME Section IX is how F-Numbers are treated for Procedure Qualification (WPS/PQR) versus Welder Performance Qualification (WPQ) .

The Strict Procedure Qualification Rule: Paragraph QW-404.4

For procedure qualification under Article II, paragraph QW-404.4 designates a change from one F-Number to any other F-Number as an essential variable (or to any filler metal not assigned an F-Number).

There is zero cross-qualification between F-Numbers for welding procedures ! A PQR qualified using an E7018 (F-No. 4) electrode cannot support a WPS specifying E6010 (F-No. 3), nor can it support an ER70S-6 (F-No. 6) GTAW wire. Each F-Number represents a unique metallurgical flux formulation and deposit dynamic that must be independently qualified by mechanical testing.

The Flexible Welder Qualification Hierarchy: Table QW-433

For welder performance qualification under Article III, Section IX recognizes that welders who master more difficult electrode coatings possess the manual dexterity to handle easier coatings. Thus, Table QW-433 establishes a progressive qualification hierarchy for groove welds:

Welder Test Coupon Electrode Used Qualified With Backing in Production Qualified Without Backing (Open Root) in Production

  • F-No. 4 with backing F-No. 1, F-No. 2, F-No. 3, and F-No. 4 None
  • F-No. 4 without backing F-No. 1, F-No. 2, and F-No. 3 F-No. 4 only
  • F-No. 3 with backing F-No. 1, F-No. 2, and F-No. 3 None
  • F-No. 3 without backing F-No. 1 and F-No. 2 F-No. 3 only
  • F-No. 2 with backing F-No. 1 and F-No. 2 None
  • F-No. 1 with backing F-No. 1 only None

F-No. 6 (Any process) F-No. 6 with backing F-No. 6 without backing (if tested without backing) +-----------------------------------------------------------------------------------------+

  • | THE F-4 WELDER QUALIFICATION SUPERIORITY RULE |
  • +-----------------------------------------------------------------------------------------+
  • | Welder qualifies on pipe with E7018 (F-4) on a backing ring: |
  • | - Can they weld E7024 (F-1) with backing? YES! |
  • | - Can they weld E6013 (F-2) with backing? YES! |
  • | - Can they weld E6010 (F-3) with backing? YES! |
  • | - Can they weld E7018 (F-4) with backing? YES! |
  • | - Can they weld E6010 (F-3) open-root (without backing)? NO! (Tested with backing). |
  • +-----------------------------------------------------------------------------------------+

Important

The Open-Root Welder Trap: A welder who tests with an F-No. 4 electrode without backing qualifies to weld F-No. 4 without backing, but for F-No. 1, F-No. 2, and F-No. 3, they are qualified with backing only ! Qualifying open-root with low-hydrogen basic electrodes (which requires dragging or weaving a tight arc) does not prove competence in whipping and manipulating an open-root cellulosic keyhole (E6010).

4. Table QW-442 A-Numbers: As-Deposited Weld Metal Chemical Composition

While F-Numbers define usability, A-Numbers (Table QW-442) classify the final chemical composition of the deposited weld metal . Understanding A-Numbers is critical because mechanical properties, corrosion resistance, and postweld heat treatment responses depend entirely on weld chemistry.

The Scope Boundary: Ferrous Metals Only!

Table QW-442 applies strictly to ferrous (iron-base) weld metals . Nonferrous alloys—including aluminum, copper, nickel, and titanium filler metals—do not have A-Numbers. One of the most common CWI exam tricks asks candidates to find the A-Number for an Inconel 625 (ERNiCrMo-3) or aluminum (ER4043) deposit; the correct answer is always that no A-Number exists .

A-Number Weld Metal Classification Nominal Elemental Breakdown Common Welding Applications

A-No. 1 Carbon Steel C ≤ 0.20 % \le 0.20\% ≤ 0.20% , Mn ≤ 1.60 % \le 1.60\% ≤ 1.60% , Si ≤ 1.00 % \le 1.00\% ≤ 1.00% Standard carbon steel welding (E7018, ER70S-6, E71T-1).

A-No. 2 Carbon-Molybdenum C ≤ 0.15 % \le 0.15\% ≤ 0.15% , Mo 0.40 % to 0.65 % 0.40\%\text{ to } 0.65\% 0.40% to 0.65% C-Mo piping and boiler tubes (E7018-A1, ER80S-D2).

A-No. 3 Chromium-Molybdenum (1-1/4Cr - 1/2Mo) Cr 0.40 % to 1.50 % 0.40\%\text{ to } 1.50\% 0.40% to 1.50% , Mo 0.40 % to 0.65 % 0.40\%\text{ to } 0.65\% 0.40% to 0.65% P-No. 4 low-alloy piping (E8018-B2, ER80S-B2).

A-No. 4 Chromium-Molybdenum (2-1/4Cr - 1Mo) Cr 1.50 % to 4.00 % 1.50\%\text{ to } 4.00\% 1.50% to 4.00% , Mo 0.40 % to 1.50 % 0.40\%\text{ to } 1.50\% 0.40% to 1.50% P-No. 5A high-pressure piping (E9018-B3, ER90S-B3).

A-No. 5 Chromium-Molybdenum (5% to 9% Cr) Cr 4.00 % to 10.50 % 4.00\%\text{ to } 10.50\% 4.00% to 10.50% , Mo 0.40 % to 1.50 % 0.40\%\text{ to } 1.50\% 0.40% to 1.50% P-No. 5B cracking tubes and refinery piping (E502, E505).

A-No. 6 Chromium-Martensitic Cr 11.00 % to 15.00 % 11.00\%\text{ to } 15.00\% 11.00% to 15.00% 410 stainless steel overlays and hardfacing deposits.

A-No. 7 Chromium-Ferritic Cr 11.00 % to 30.00 % 11.00\%\text{ to } 30.00\% 11.00% to 30.00% 430 stainless cladding and nitric acid service piping.

A-No. 8 Chromium-Nickel Austenitic Cr 14.50 % to 30.00 % 14.50\%\text{ to } 30.00\% 14.50% to 30.00% , Ni 7.50 % to 15.00 % 7.50\%\text{ to } 15.00\% 7.50% to 15.00% Standard 300-series austenitic stainless (E308L, E316L).

A-No. 9 Chromium-Nickel Austenitic (High Alloy) Cr 19.00 % to 30.00 % 19.00\%\text{ to } 30.00\% 19.00% to 30.00% , Ni 15.00 % to 37.00 % 15.00\%\text{ to } 37.00\% 15.00% to 37.00% Dissimilar welding and high-alloy stainless (E309L, E310).

A-No. 10 Nickel Alloy Steel Ni 1.50 % to 4.00 % 1.50\%\text{ to } 4.00\% 1.50% to 4.00% Low-temperature nickel steels (E8018-C1, E8018-C2).

A-No. 11 Manganese-Molybdenum Mn 1.25 % to 2.25 % 1.25\%\text{ to } 2.25\% 1.25% to 2.25% , Mo 0.25 % to 0.75 % 0.25\%\text{ to } 0.75\% 0.25% to 0.75% High-strength pressure vessel fabrication (E8018-D1).

A-No. 12 Nickel-Chromium-Molybdenum Ni 0.50 % to 4.25 % 0.50\%\text{ to } 4.25\% 0.50% to 4.25% , Cr 0.30 % to 3.15 % 0.30\%\text{ to } 3.15\% 0.30% to 3.15% , Mo 0.10 % to 1.15 % 0.10\%\text{ to } 1.15\% 0.10% to 1.15% High-yield quenched and tempered steels (E10018-M, E11018-M).

5. Establishing A-Numbers under QW-404.5 & Requalification Rules

Paragraph QW-404.5 governs how a fabricator determines and verifies the A-Number of a weld deposit. A change in the weld metal A-Number is an essential variable for procedure qualification. If a WPS was qualified using an A-No. 1 deposit (carbon steel), changing production welding to an A-No. 2 (C-Mo) or A-No. 3 (Cr-Mo) deposit requires qualifying an entirely new PQR.

Methods for Establishing A-Number Compliance (QW-404.5)

Section IX provides four distinct methods for an organization to determine the A-Number on a PQR:

Chemical Analysis of the Actual PQR Weld Deposit: Taking chips or drillings directly from the qualification coupon weld metal and conducting a laboratory spectrometer analysis.

Chemical Analysis from an All-Weld-Metal Coupon: Using certified chemistry data from a separate coupon welded in accordance with the applicable SFA specification.

Certified Material Test Report (CMTR) / Manufacturer's Certification: Relying on the filler metal manufacturer's certified chemical analysis for that specific heat/lot of electrode or flux-wire combination.

AWS Classification Chemistry in Section II Part C: Assuming the weld deposit matches the chemical composition limits published in the SFA specification for that AWS classification.

Caution

Special Warning for SAW and FCAW: Under QW-404.5, for Submerged Arc Welding (SAW) and Gas-Shielded Flux-Cored Arc Welding (FCAW), the alloy content of the deposit depends heavily on flux alloy transfer, wire dilution, and shielding gas interaction. Fabricators cannot simply assume wire chemistry equals deposit chemistry; the flux-wire combination or lot CMTR must verify the final deposited A-Number.

Essential Variable Contrast: Welder Qualification Immunity

Does a change in A-Number affect a welder's qualification? No! A-Numbers are never an essential variable for welder performance qualification . A welder who qualifies on carbon steel using E7018 (F-No. 4, A-No. 1) is fully qualified to weld P-No. 4 chrome-moly steel using E8018-B2 (F-No. 4, A-No. 3) in production! The welder's manual manipulation of the basic flux puddle is identical, even though the chemical composition differs.

6. Practical Exam Traps & Code Navigation Strategies

Trap 1: Confusing F-Number Welder Rules with Procedure Rules: A question states: "A manufacturer qualifies a PQR using SMAW with an AWS E7018 (F-No. 4) electrode. Can the manufacturer issue a WPS specifying AWS E6010 (F-No. 3) based on this PQR?" Candidates often remember that an F-4 welder can weld F-3 with backing, and mistakenly answer YES. For procedures (WPS/PQR) , F-Number changes are strictly essential variables under QW-404.4 with zero cross-qualification. The answer is an emphatic NO .

Trap 2: Assigning A-Numbers to Nonferrous Alloys: If an exam item asks for the A-Number of an ERNiCr-3 (Inconel 82) or ERCuSi-A (silicon bronze) filler metal, look for the option stating: "No A-Number is assigned because Table QW-442 applies only to ferrous weld metals."

Trap 3: F-6 Process Boundaries for Welders: Under Table QW-433, testing with an F-No. 6 filler metal qualifies only F-No. 6 filler metals. An operator qualified on GTAW using ER70S-6 (F-6) is never qualified to weld SMAW with E7018 (F-4) or E6010 (F-3) without a separate performance test.

Loading diagram... Figure 9.2: Filler Metal Qualification Framework: F-Number Usability vs. A-Number Metallurgy