Study guide

2.1 Groove and Fillet Weld Design & Effective Throat Calculations

AWS D1.1 Structural Steel Endorsement Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Exam Structure, Code Scope & General Requirements

1.1 AWS D1.1 Endorsement Exam Format & Open-Book Navigation 1.2 Clause 1 Scope, Responsibilities & Structural Classifications 1.3 Normative References, Terminology & Base Metal Scope

2 Chapter 2: Design of Welded Connections (Clause 4)

2.1 Groove and Fillet Weld Design & Effective Throat Calculations 2.2 Statically Loaded Connection Details, Geometry Limits & Transitions 2.3 Cyclically Loaded Structures, Stress Categories & Fatigue Life Design

3 Chapter 3: Prequalification of Welding Procedure Specifications (Clause 5)

3.1 Prequalified Processes, Base Metal Groups & Matching Filler Metals 3.2 Prequalified Joint Geometries, CJP/PJP Details & Backing 3.3 Prequalified Minimum Fillet Sizes & Preheat/Interpass Temperatures

4 Chapter 4: Welding Procedure Specification (WPS) Qualification (Clause 6, Part B)

4.1 WPS Qualification Requirements, PQR Coupon Testing & Mechanical Evaluation 4.2 PQR Mechanical Test Types: Tension, Guided Bend & Macroetch 4.3 WPS Essential Variables, Base Metal Ranges & Qualified Positions (Table 6.6)

5 Chapter 5: Welder, Welding Operator & Tack Welder Performance Qualification (Clause 6, Part C)

5.1 Welder Qualification Test Plates, Positions & Pipe Assemblies 5.2 Performance Test Evaluation (Visual, Guided Bend, Macroetch) & Retest Rules 5.3 Performance Essential Variables, Qualification Limits (Table 6.12) & Continuity

6 Chapter 6: Fabrication & Workmanship (Clause 7)

6.1 Base Metal Preparation, Thermal Cutting Tolerances & Fit-Up 6.2 Welding Consumable Storage, Low-Hydrogen Exposure Limits & Baking 6.3 Distortion Control, Arc Strikes, Tack Welds & Weld Repair Rules

7 Chapter 7: Visual Inspection & Acceptance Criteria (Clause 8, Parts A-C)

7.1 Inspector Responsibilities, Qualifications (CWI/SCWI) & Inspection Sequence 7.2 Table 8.1 Visual Inspection Criteria: Static vs. Cyclic Non-Tubular Connections 7.3 Weld Profiles, Undercut Tolerances, Porosity Limits & Crack Rejection

8 Chapter 8: Nondestructive Testing (NDT) Procedures & Acceptance (Clause 8, Part D)

8.1 Radiographic Testing (RT) Requirements, IQI Placement & Acceptance 8.2 Ultrasonic Testing (UT) Procedures, Calibration & Tables 8.2 / 8.3 8.3 Magnetic Particle (MT), Liquid Penetrant (PT) & Inspection Records

9 Chapter 9: Stud Welding & Tubular Structures (Clauses 9 & 10)

9.1 Clause 9 Stud Welding: Pre-Production Testing, Bend Tests & Flash Acceptance 9.2 Clause 10 Tubular Connections: T-, Y-, K-Joints, Geometry & Effective Throat 9.3 Clause 10 Tubular Qualification & Inspection: 6GR Restriction Testing & Acceptance

10 Chapter 10: Strengthening/Repair of Existing Structures & Welding Symbols (Clause 11 & AWS A2.4)

10.1 Clause 11 Evaluation, Base Metal Identification & Welding Under Load 10.2 Clause 11 Repair Workmanship, Heat Input Control & Member Restoration 10.3 AWS A2.4 Welding Symbols: Notation, Sizing, Pitch & Field Flags

2.1 Groove and Fillet Weld Design & Effective Throat Calculations

Key Takeaways Explain This Topic AI

Complete Joint Penetration (CJP) groove welds develop an effective throat equal to the thickness of the thinner part joined, transmitting full tensile and compressive capacity without design deductions.

Partial Joint Penetration (PJP) groove welds with groove angles between 45° and 59° welded via SMAW, GMAW, or FCAW require a 1/8 in. [3 mm] deduction from the groove depth (E = S - 1/8 in.) to determine effective throat.

For 90° equal-leg fillet welds, theoretical throat equals 0.707w, while actual throat includes convexity, which is strictly capped by AWS D1.1 Clause 7.23.1 and Figure 7.4.

Skewed T-joints with acute dihedral angles between 30° and 59° require a Z-loss deduction that depends on the welding process: 1/8 in. from 45° to under 60° for all processes, then 1/4 in. (SMAW, FCAW-S) or 3/8 in. (FCAW-G, GMAW) from 30° to under 45°. Dihedral angles below 30° are prohibited without qualification testing.

Combination welds superimpose a fillet weld over a groove weld, measuring total effective throat along a single continuous vector from the joint root to the outer weld face.

Last updated: August 2026

2.1 Groove and Fillet Weld Design & Effective Throat Calculations

Quick Answer: In AWS D1.1/D1.1M:2025 Clause 4 Part A , weld strength is governed by the effective throat ( t e t_e t e ​ or E E E ) and effective length ( L L L ) . For CJP groove welds , E E E equals the thickness of the thinner part joined ( t 1 t_1 t 1 ​ ). For PJP groove welds , E E E equals the groove depth ( S S S ) when the included angle α ≥ 60 ∘ \alpha \ge 60^\circ α ≥ 6 0 ∘ , but requires a 1 / 8 in. 1/8\text{ in.} 1/8 in. [ 3 mm 3\text{ mm} 3 mm ] deduction ( E = S − 1 / 8 in. E = S - 1/8\text{ in.} E = S − 1/8 in. ) when 45 ∘ ≤ α < 60 ∘ 45^\circ \le \alpha < 60^\circ 4 5 ∘ ≤ α < 6 0 ∘ for SMAW, GMAW, and FCAW. For standard 90 ∘ 90^\circ 9 0 ∘ equal-leg fillet welds, t e = 0.707 × w t_e = 0.707 \times w t e ​ = 0.707 × w . In skewed T-joints with acute dihedral angles between 30 ∘ 30^\circ 3 0 ∘ and 59 ∘ 59^\circ 5 9 ∘ , a Z-loss deduction ( 1 / 8 in. 1/8\text{ in.} 1/8 in. , 1 / 4 in. 1/4\text{ in.} 1/4 in. , or 3 / 8 in. 3/8\text{ in.} 3/8 in. depending on the process) must be subtracted from the theoretical throat. Dihedral angles below 30 ∘ 30^\circ 3 0 ∘ are strictly prohibited without procedure qualification testing.

Mastery of welded connection design under Clause 4 is one of the most heavily tested areas on the AWS D1.1 Code Endorsement Examination. Inspectors and welding engineers must be capable of calculating the precise load-carrying cross-sectional area of any welded joint from design drawings, determining whether joint preparations meet code limits, and calculating geometric deductions for groove angle and dihedral skew.

CJP vs. PJP Groove Weld Fundamentals

Groove welds are classified into two fundamental categories based on the extent of fusion penetration through the base metal thickness:

Complete Joint Penetration (CJP) Groove Welds (Clause 4.5): A groove weld that extends completely through the joint thickness, achieving total fusion of weld metal and base metal throughout the entire cross-section. CJP welds require backing, complete joint backgouging to sound metal prior to second-side welding, or prequalified open-root joint geometry.

Partial Joint Penetration (PJP) Groove Welds (Clause 4.5): A groove weld in which the depth of joint preparation and weld penetration is intentionally less than the full thickness of the base metal. PJP welds leave an unfused root ligament.

CJP vs. PJP Engineering Comparison

Design Parameter Complete Joint Penetration (CJP) Partial Joint Penetration (PJP)

Effective Throat ( E E E ) Full thickness of thinner member ( t 1 t_1 t 1 ​ ) Calculated based on groove depth ( S S S ) and included angle ( α \alpha α )

Backgouging / Backing Required (or qualified open-root) Not required; welded from one or both sides

Static Tensile Strength 100% of matching base metal capacity Governed by effective throat area ( E × L E \times L E × L )

Cyclic Stress Category Category B (ground flush) or Category C/D Category C, D, or E (depending on root geometry)

  • Root Notch Effect None (solid fused throat) Unfused root acts as built-in stress concentration notch
  • Inspection Standard RT, UT, or visual inspection Visual inspection, UT (when specified), macroetch sectioning
  • PJP Effective Throat ( E E E ) Calculations & Groove Angle Rules

Under Clause 4.5 , the effective throat ( E E E ) of a PJP groove weld depends on the welding process , the welding position , and the included groove angle ( α \alpha α ) :

Groove Angle α ≥ 60 ∘ \alpha \ge 60^\circ α ≥ 6 0 ∘ : The arc can penetrate directly to the root apex. The effective throat is equal to the depth of the groove preparation: E = S \mathbf{E = S} E = S

Groove Angle 45 ∘ ≤ α < 60 ∘ 45^\circ \le \alpha < 60^\circ 4 5 ∘ ≤ α < 6 0 ∘ (SMAW, GMAW, FCAW): Electrode access is restricted by narrow sidewall interference, causing incomplete root fusion. A 1 / 8 in. 1/8\text{ in.} 1/8 in. [ 3 mm 3\text{ mm} 3 mm ] deduction must be subtracted from the prepared groove depth: E = S − 1 / 8 in. [ S − 3 mm ] \mathbf{E = S - 1/8\text{ in.} \quad [S - 3\text{ mm}]} E = S − 1/8 in. [ S − 3 mm ]

Submerged Arc Welding (SAW): For SAW with α ≥ 60 ∘ \alpha \ge 60^\circ α ≥ 6 0 ∘ , E = S E = S E = S . For 45 ∘ ≤ α < 60 ∘ 45^\circ \le \alpha < 60^\circ 4 5 ∘ ≤ α < 6 0 ∘ in the flat (1G) position, E = S E = S E = S without deduction due to the deep penetration characteristics of the high-amperage submerged arc.

Gas Metal Arc Welding (GMAW - Short Circuiting Transfer / GMAW-S): GMAW-S is not prequalified under Clause 5 and requires procedure qualification under Clause 6 for all groove angles.

AWS D1.1 PJP Effective Throat Deduction Schedule

  • Welding Process Included Groove Angle ( α \alpha α ) Welding Position Effective Throat ( E E E )
  • SMAW α ≥ 60 ∘ \alpha \ge 60^\circ α ≥ 6 0 ∘ All E = S E = S E = S

SMAW 45 ∘ ≤ α < 60 ∘ 45^\circ \le \alpha < 60^\circ 4 5 ∘ ≤ α < 6 0 ∘ All E = S − 1 / 8 in. E = S - 1/8\text{ in.} E = S − 1/8 in. [ 3 mm 3\text{ mm} 3 mm ]

GMAW (Spray/Globular) α ≥ 60 ∘ \alpha \ge 60^\circ α ≥ 6 0 ∘ All E = S E = S E = S

GMAW (Spray/Globular) 45 ∘ ≤ α < 60 ∘ 45^\circ \le \alpha < 60^\circ 4 5 ∘ ≤ α < 6 0 ∘ Flat (1G), Horizontal (2F/2G) E = S − 1 / 8 in. E = S - 1/8\text{ in.} E = S − 1/8 in. [ 3 mm 3\text{ mm} 3 mm ]

FCAW (Gas-Shielded / Self-Shielded) α ≥ 60 ∘ \alpha \ge 60^\circ α ≥ 6 0 ∘ All E = S E = S E = S

FCAW (Gas-Shielded / Self-Shielded) 45 ∘ ≤ α < 60 ∘ 45^\circ \le \alpha < 60^\circ 4 5 ∘ ≤ α < 6 0 ∘ All E = S − 1 / 8 in. E = S - 1/8\text{ in.} E = S − 1/8 in. [ 3 mm 3\text{ mm} 3 mm ]

SAW α ≥ 60 ∘ \alpha \ge 60^\circ α ≥ 6 0 ∘ Flat (1G) E = S E = S E = S

SAW 45 ∘ ≤ α < 60 ∘ 45^\circ \le \alpha < 60^\circ 4 5 ∘ ≤ α < 6 0 ∘ Flat (1G) E = S E = S E = S (no deduction)

Worked Example 1: PJP Effective Throat Comparison

Problem: A fabricator prepares two 1.5 in. 1.5\text{ in.} 1.5 in. [ 38 mm 38\text{ mm} 38 mm ] thick plates with a single-bevel groove preparation having a groove depth S = 0.75 in. S = 0.75\text{ in.} S = 0.75 in. [ 19 mm 19\text{ mm} 19 mm ].

Joint A: Prepared with a 60 ∘ 60^\circ 6 0 ∘ included bevel angle, welded using FCAW-G.

Joint B: Prepared with a 45 ∘ 45^\circ 4 5 ∘ included bevel angle, welded using FCAW-G.

Calculation:

For Joint A ( α = 60 ∘ ≥ 60 ∘ \alpha = 60^\circ \ge 60^\circ α = 6 0 ∘ ≥ 6 0 ∘ ): E A = S = 0.750 in. [ 19.0 mm ] E_A = S = 0.750\text{ in.} \quad [19.0\text{ mm}] E A ​ = S = 0.750 in. [ 19.0 mm ]

For Joint B ( 45 ∘ ≤ α = 45 ∘ < 60 ∘ 45^\circ \le \alpha = 45^\circ < 60^\circ 4 5 ∘ ≤ α = 4 5 ∘ < 6 0 ∘ ): E B = S − 0.125 in. = 0.750 in. − 0.125 in. = 0.625 in. ( 5 / 8 in. ) [ 15.9 mm ] E_B = S - 0.125\text{ in.} = 0.750\text{ in.} - 0.125\text{ in.} = 0.625\text{ in.} \quad (5/8\text{ in.}) \quad [15.9\text{ mm}] E B ​ = S − 0.125 in. = 0.750 in. − 0.125 in. = 0.625 in. ( 5/8 in. ) [ 15.9 mm ]

Conclusion: Reducing the groove angle from 60 ∘ 60^\circ 6 0 ∘ to 45 ∘ 45^\circ 4 5 ∘ reduces the load-carrying effective throat by 16.7 % 16.7\% 16.7% , requiring a larger groove depth or longer weld length to carry equivalent static shear/tension.

Fillet Weld Geometry, Throat Definitions & Convexity Limits

Fillet welds are triangular in cross-section and transmit shear loads across the joint root. AWS D1.1 defines three distinct throat dimensions ( Clause 4.5 ):

Theoretical Throat ( t t t_t t t ​ ): The perpendicular distance from the beginning of the joint root to the hypotenuse of the largest right triangle that can be inscribed within the fillet weld cross-section.

For an equal-leg 90 ∘ 90^\circ 9 0 ∘ fillet weld with leg size w w w : t t = w × cos ⁡ ( 45 ∘ ) = w × 2 2 ≈ 0.707 × w t_t = w \times \cos(45^\circ) = w \times \frac{\sqrt{2}}{2} \approx 0.707 \times w t t ​ = w × cos ( 4 5 ∘ ) = w × 2 2 ​ ​ ≈ 0.707 × w

Effective Throat ( t e t_e t e ​ ): The minimum distance from the joint root to the weld face, minus any convexity. In standard design without deep penetration credit: t e = t t = 0.707 × w t_e = t_t = 0.707 \times w t e ​ = t t ​ = 0.707 × w (Note: Submerged Arc Welding [SAW] allows deep penetration credit if verified by Clause 6 PQR macroetch sectioning, adding root penetration to t e t_e t e ​ .)

Actual Throat ( t a t_a t a ​ ): The shortest distance from the joint root to the exterior face of the weld, including root penetration and weld reinforcement (convexity): t a = t e + Convexity + Root Penetration t_a = t_e + \text{Convexity} + \text{Root Penetration} t a ​ = t e ​ + Convexity + Root Penetration

Unequal-Leg Fillet Welds

When design constraints dictate unequal fillet weld legs ( w 1 w_1 w 1 ​ and w 2 w_2 w 2 ​ ) intersecting at 90 ∘ 90^\circ 9 0 ∘ , the theoretical and effective throat is calculated from the altitude of the inscribed right triangle: t e = w 1 ⋅ w 2 w 1 2 + w 2 2 t_e = \frac{w_1 \cdot w_2}{\sqrt{w_1^2 + w_2^2}} t e ​ = w 1 2 ​ + w 2 2 ​ ​ w 1 ​ ⋅ w 2 ​ ​

Maximum Convexity Limits (Clause 7.23.1 & Figure 7.4)

Excessive convexity creates sharp notch transitions at the weld toes, drastically increasing stress concentration. AWS D1.1 Clause 7.23.1 and Figure 7.4 limit fillet weld convexity ( C C C ) based on the measured width of the weld face ( W W W ):

Measured Width of Weld Face ( W W W ) Maximum Allowable Convexity ( C m a x C_{max} C ma x ​ )

W ≤ 5 / 16 in. W \le 5/16\text{ in.} W ≤ 5/16 in. [ 8 mm 8\text{ mm} 8 mm ] 1 / 16 in. 1/16\text{ in.} 1/16 in. [ 1.6 mm 1.6\text{ mm} 1.6 mm ]

5 / 16 in. < W < 1.0 in. 5/16\text{ in.} < W < 1.0\text{ in.} 5/16 in. < W < 1.0 in. [ 8 mm < W < 25 mm 8\text{ mm} < W < 25\text{ mm} 8 mm < W < 25 mm ] 1 / 8 in. 1/8\text{ in.} 1/8 in. [ 3.2 mm 3.2\text{ mm} 3.2 mm ]

W ≥ 1.0 in. W \ge 1.0\text{ in.} W ≥ 1.0 in. [ 25 mm 25\text{ mm} 25 mm ] 3 / 16 in. 3/16\text{ in.} 3/16 in. [ 4.8 mm 4.8\text{ mm} 4.8 mm ]

Worked Example 2: Unequal-Leg Fillet Weld Theoretical Throat

Problem: An unequal-leg fillet weld has nominal leg dimensions w 1 = 3 / 8 in. w_1 = 3/8\text{ in.} w 1 ​ = 3/8 in. [ 0.375 in. 0.375\text{ in.} 0.375 in. ] and w 2 = 1 / 2 in. w_2 = 1/2\text{ in.} w 2 ​ = 1/2 in. [ 0.500 in. 0.500\text{ in.} 0.500 in. ] in a 90 ∘ 90^\circ 9 0 ∘ T-joint. Calculate the effective throat ( t e t_e t e ​ ).

Calculation: t e = w 1 ⋅ w 2 w 1 2 + w 2 2 = 0.375 × 0.500 ( 0.375 ) 2 + ( 0.500 ) 2 = 0.1875 0.140625 + 0.250000 = 0.1875 0.390625 = 0.1875 0.625 = 0.300 in. [ 7.62 mm ] t_e = \frac{w_1 \cdot w_2}{\sqrt{w_1^2 + w_2^2}} = \frac{0.375 \times 0.500}{\sqrt{(0.375)^2 + (0.500)^2}} = \frac{0.1875}{\sqrt{0.140625 + 0.250000}} = \frac{0.1875}{\sqrt{0.390625}} = \frac{0.1875}{0.625} = 0.300\text{ in.} \quad [7.62\text{ mm}] t e ​ = w 1 2 ​ + w 2 2 ​ ​ w 1 ​ ⋅ w 2 ​ ​ = ( 0.375 ) 2 + ( 0.500 ) 2 ​ 0.375 × 0.500 ​ = 0.140625 + 0.250000 ​ 0.1875 ​ = 0.390625 ​ 0.1875 ​ = 0.625 0.1875 ​ = 0.300 in. [ 7.62 mm ]

Skewed T-Joints and Dihedral Angle Limits (Clause 4.5 & Annex A)

In skewed connections, members intersect at an acute or obtuse dihedral angle ( Ψ \Psi Ψ ) rather than 90 ∘ 90^\circ 9 0 ∘ . The dihedral angle governs joint accessibility, root fusion, and allowable weld throat:

Standard Range ( 80 ∘ ≤ Ψ ≤ 100 ∘ 80^\circ \le \Psi \le 100^\circ 8 0 ∘ ≤ Ψ ≤ 10 0 ∘ ): Treated as a standard 90 ∘ 90^\circ 9 0 ∘ T-joint; no geometric deductions apply ( Z = 0 Z = 0 Z = 0 ).

Acute Skewed Range ( 60 ∘ ≤ Ψ < 80 ∘ 60^\circ \le \Psi < 80^\circ 6 0 ∘ ≤ Ψ < 8 0 ∘ ): Fillet welds are fully permitted without Z-loss deduction ( Z = 0 Z = 0 Z = 0 ). Effective throat is computed using skewed trigonometry: t e = w sin ⁡ Ψ 2 cos ⁡ ( Ψ / 2 ) t_e = \frac{w \sin\Psi}{2 \cos(\Psi / 2)} t e ​ = 2 cos ( Ψ/2 ) w sin Ψ ​

Acute Skewed Range ( 30 ∘ ≤ Ψ < 60 ∘ 30^\circ \le \Psi < 60^\circ 3 0 ∘ ≤ Ψ < 6 0 ∘ ): The tight root apex prevents the welding arc from reaching the root. A Z-loss deduction ( Z Z Z ) must be subtracted from the theoretical throat to determine effective throat: t e = t t − Z \mathbf{t_e = t_t - Z} t e ​ = t t ​ − Z

Prohibited Range ( Ψ < 30 ∘ \Psi < 30^\circ Ψ < 3 0 ∘ ): Welds in joints having a dihedral angle less than 30 ∘ 30^\circ 3 0 ∘ are strictly prohibited for prequalification and design. Such welds shall not be considered capable of transmitting design load unless qualified by specific testing in accordance with Clause 6 .

Skewed T-Joint Z-Loss Deduction Table (Table 4.2)

Dihedral Angle Range ( Ψ \Psi Ψ ) SMAW FCAW-S FCAW-G GMAW

60 ∘ > Ψ ≥ 45 ∘ 60^\circ > \Psi \ge 45^\circ 6 0 ∘ > Ψ ≥ 4 5 ∘ 1 / 8 in. 1/8\text{ in.} 1/8 in. [ 3 mm 3\text{ mm} 3 mm ] 1 / 8 in. 1/8\text{ in.} 1/8 in. [ 3 mm 3\text{ mm} 3 mm ] 1 / 8 in. 1/8\text{ in.} 1/8 in. [ 3 mm 3\text{ mm} 3 mm ] 1 / 8 in. 1/8\text{ in.} 1/8 in. [ 3 mm 3\text{ mm} 3 mm ]

45 ∘ > Ψ ≥ 30 ∘ 45^\circ > \Psi \ge 30^\circ 4 5 ∘ > Ψ ≥ 3 0 ∘ 1 / 4 in. 1/4\text{ in.} 1/4 in. [ 6 mm 6\text{ mm} 6 mm ] 1 / 4 in. 1/4\text{ in.} 1/4 in. [ 6 mm 6\text{ mm} 6 mm ] 3 / 8 in. 3/8\text{ in.} 3/8 in. [ 10 mm 10\text{ mm} 10 mm ] 3 / 8 in. 3/8\text{ in.} 3/8 in. [ 10 mm 10\text{ mm} 10 mm ]

The trap in Table 4.2 is the process column, not the angle column. Below 45 ∘ 45^\circ 4 5 ∘ , the gas-shielded processes (FCAW-G and GMAW) lose an extra 1 / 8 in. 1/8\text{ in.} 1/8 in. relative to SMAW and FCAW-S, because the shielding gas column disturbs the arc in the tight root apex. Reading only the angle row and applying 1 / 4 in. 1/4\text{ in.} 1/4 in. to every process is the single most common Z-loss error. Note also that GMAW and FCAW-G Z values are listed for the flat and horizontal positions; D1.1 does not tabulate them for vertical and overhead.

Worked Example 3: Skewed T-Joint Effective Throat with Z-Loss

Problem: A skewed bracing member intersects a column flange at an acute dihedral angle Ψ = 40 ∘ \Psi = 40^\circ Ψ = 4 0 ∘ . The fillet weld is deposited using SMAW in the flat position. Trigonometric layout produces a theoretical throat t t = 0.500 in. t_t = 0.500\text{ in.} t t ​ = 0.500 in. [ 12.7 mm 12.7\text{ mm} 12.7 mm ]. What is the effective throat ( t e t_e t e ​ ) credited for structural design?

Calculation:

Check dihedral angle range: 30 ∘ ≤ Ψ = 40 ∘ < 45 ∘ 30^\circ \le \Psi = 40^\circ < 45^\circ 3 0 ∘ ≤ Ψ = 4 0 ∘ < 4 5 ∘ .

Look up Z-loss deduction from Table 4.2: For SMAW at 40 ∘ 40^\circ 4 0 ∘ , Z = 1 / 4 in. = 0.250 in. Z = 1/4\text{ in.} = 0.250\text{ in.} Z = 1/4 in. = 0.250 in. [ 6.4 mm 6.4\text{ mm} 6.4 mm ].

Calculate effective throat: t e = t t − Z = 0.500 in. − 0.250 in. = 0.250 in. ( 1 / 4 in. ) [ 6.35 mm ] t_e = t_t - Z = 0.500\text{ in.} - 0.250\text{ in.} = 0.250\text{ in.} \quad (1/4\text{ in.}) \quad [6.35\text{ mm}] t e ​ = t t ​ − Z = 0.500 in. − 0.250 in. = 0.250 in. ( 1/4 in. ) [ 6.35 mm ]

Combination Groove and Fillet Welds (Clause 4.5)

In heavy structural connections, a fillet weld is frequently placed over a PJP or CJP groove weld to reduce stress concentrations at the reentrant corner or to provide supplementary shear area.

Effective Throat Determination: The effective throat of a combination weld is the shortest straight-line distance from the joint root to the face of the superimposed fillet weld, minus convexity.

Calculation: When a fillet weld of leg size w f w_f w f ​ is superimposed on a PJP groove weld having effective depth E g E_g E g ​ , the effective throat is not simply the arithmetic sum of the two throats; rather, it is measured along a continuous straight ray passing from the root through the fusion face.