Study guide

12.7 Steel Joists, Girders & Metal Deck

Arizona General Contractor Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Introduction & Exam Overview

1.1 Current Exam Facts 1.2 The Arizona Contractor Licensing Path 1.3 How to Use This Guide & Study Plan

2 Chapter 2: Arizona ROC & Licensing Law

2.1 The Arizona Registrar of Contractors 2.2 License Classifications 2.3 Qualifying Party & Experience Requirements 2.4 Application, Fees, Bond & Background Check 2.5 License Bonds, Cash Deposits & Bond Claims 2.6 Unlicensed Contracting: Penalties & Lost Remedies 2.7 Advertising Rules, Contract Disclosures & Workmanship Standards

3 Chapter 3: The Exams — SRE, Trade & NASCLA

3.1 The Statutes & Rules Exam (SRE) 3.2 The PSI Trade Exam 3.3 The NASCLA Commercial General Building Exam Option

4 Chapter 4: License Maintenance, Recovery Fund & Discipline

4.1 License Renewal & Continuing Education 4.2 The Residential Contractors' Recovery Fund 4.3 ROC Disciplinary Actions & Penalties

5 Chapter 5: Contract Law & Disputes

5.1 Arizona Contract Fundamentals 5.2 Construction Contract Terms & Provisions 5.3 Change Orders & Modifications 5.4 Dispute Resolution & ROC Complaints 5.5 The Arizona Prompt Payment Act

6 Chapter 6: Liens, Bonds & Insurance

6.1 Arizona Mechanics' Lien Law Overview 6.2 Lien Notices, Recording & Deadlines 6.3 Contract Bonds: Bid, Performance & Payment 6.4 Insurance Requirements

7 Chapter 7: Financial Management & Taxes

7.1 Accounting & Financial Statements 7.2 Estimating, Bidding & Markup 7.3 Taxes & Payroll

8 Chapter 8: Project Management

8.1 Scheduling & the Critical Path Method 8.2 Supervision, Subcontractors & Quality Control 8.3 Project Documentation & Closeout

9 Chapter 9: Safety & OSHA

9.1 OSHA Construction Standards Overview 9.2 Fall Protection, Scaffolds & Ladders 9.3 Excavation, Trenching & Electrical Safety 9.4 Heat Illness Prevention & Arizona Job-Site Hazards

10 Chapter 10: Building Codes, Permits & Plan Reading

10.1 IRC 2018 & IBC 2018 Fundamentals 10.2 Permits, Plan Review & Inspections 10.3 Energy Code & Accessibility 10.4 Reading Construction Drawings & Specifications 10.5 Means of Egress & Fire-Resistance-Rated Construction

11 Chapter 11: Sitework, Concrete & Masonry

11.1 Sitework: Surveying, Excavation & Grading 11.2 Concrete: Formwork, Reinforcement & Placing 11.3 Masonry: Brick, Block & Mortar 11.4 Soils, Compaction & Earthwork Testing 11.5 Concrete Materials & Mix Design 11.6 Concrete Curing, Joints, Testing & Defects 11.7 Masonry Reinforcement, Grouting & Wall Systems

12 Chapter 12: Carpentry, Metals & Building Envelope

12.1 Carpentry & Framing 12.2 Metals & Metal Framing 12.3 Thermal & Moisture Protection 12.4 Doors, Windows & Finishes 12.5 Engineered Wood, Trusses & Connectors 12.6 Structural Steel Erection & Connections 12.7 Steel Joists, Girders & Metal Deck

13 Chapter 13: Roofing, Waterproofing & Interior Finishes

13.1 Roofing Systems 13.2 Waterproofing, Flashing & Sealants 13.3 Interior Finishes: Gypsum, Stucco, Flooring & Paint

14 Chapter 14: Building Systems for the General Contractor

14.1 Mechanical & Plumbing Systems 14.2 Electrical Systems & Temporary Power

12.7 Steel Joists, Girders & Metal Deck

Key Takeaways Explain This Topic AI

Open-web steel joist designations such as 24K9 encode depth in inches, series, and chord section number

Bridging holds joists laterally during erection and in service; the number of rows comes from the joist tables and bridging must be installed and anchored before workers stand on the joist

No construction loads may be placed on a joist until all bridging is completely installed and anchored

Metal deck is classified as form deck, roof deck, or composite floor deck, and composite deck acts structurally with the concrete topping through embossments

Deck attachment — puddle welds, screws, or power-actuated fasteners plus sidelap fasteners — is what makes the deck a structural diaphragm

Last updated: August 2026

The Systems Above Your Head

Quick Answer: Open-web steel joists and joist girders span between beams and columns; metal deck spans between joists and forms the roof or floor surface. Together they account for a large share of the Metals (13 items) questions on the AZ ROC commercial exam, and they are the source of some of the most serious construction-phase collapses in the industry.

The economics are simple: an open-web joist gets the same span as a rolled beam at a fraction of the weight, because the web is mostly air. That efficiency is also the hazard — until a joist is bridged and decked, it has almost no lateral stability.

Reading Joist Designations

  • Designation Meaning
  • 24K9 24 in. deep, K series (open-web steel joist), chord section 9
  • 28LH10 28 in. deep, LH series (longspan), chord section 10
  • 52DLH15 52 in. deep, DLH series (deep longspan)
  • 44G8N9.6K Joist girder : 44 in. deep, 8 joist spaces, 9.6 kip panel point load
  • Series Typical span range
  • K — open web steel joists Short to medium spans
  • LH — longspan Longer spans
  • DLH — deep longspan Long-span roof structures
  • Joist girders Support joists at panel points, framing into columns

The chord number is a relative section size, not a dimension: a 24K9 has heavier chords and greater capacity than a 24K4 at the same depth. Load tables published by the joist institute give allowable total and live loads by span for each designation, and the structural drawings identify the required designation plus any special loads such as suspended mechanical units.

Bridging — the Rule That Prevents Collapses

Bridging is the horizontal and diagonal bracing between joists. It does two jobs: it stabilizes the joists laterally during erection, and it braces the compression chord in service.

  • Type What it is
  • Horizontal bridging Continuous angles or bars attached to the top and bottom chords
  • Diagonal (cross) bridging X-braces between adjacent joists

The number of rows required comes from the joist tables and increases with span. Two rules control the field:

Bridging must be completely installed and anchored before any construction loads are placed on the joists. That includes workers, bundles of deck, welding equipment, and stacked material. An unbridged joist under a bundle of deck will roll over.

Bridging terminus points must be anchored — the end of each bridging line must be fastened to a wall, beam, or other point that can take the force, or the line simply moves as an assembly.

Deck bundles are the specific hazard the industry keeps relearning. Landing a full bundle of deck on a few unbridged joists concentrates a load the system was never designed to take in that configuration. Bundles are placed only over or adjacent to bearing points, distributed as the erection plan directs, and only after bridging is complete.

Warning: joists are designed for uniformly distributed loads applied at the panel points . Hanging a mechanical unit, a pipe, or a scoreboard from a mid-panel web member is not a field decision — concentrated loads require the joist manufacturer's or engineer's direction, and often a reinforcing detail.

Metal Deck

  • Deck type Function
  • Form deck Serves only as a stay-in-place form for a concrete slab; the concrete carries the load once cured
  • Roof deck Spans between joists and supports roof insulation and membrane; typically type B (1½ in. rib)

Composite floor deck Acts structurally together with the concrete topping through embossments rolled into the flutes that key into the slab

Cellular deck Adds a flat bottom plate to create raceways for electrical distribution

The composite distinction is the exam item. Composite deck is not a form; the embossed ribs transfer horizontal shear between deck and slab so the two act as one member. Substituting plain form deck where composite deck was specified produces a floor with a fraction of its design capacity and no visible difference from below once it is painted.

Attachment is what converts loose sheets into a structural diaphragm capable of carrying lateral wind and seismic load to the frame:

Attachment Where

Puddle (arc-spot) welds , often with weld washers on thin deck Deck to supporting steel, at the pattern shown (e.g., 36/4 or 36/7)

  • Screws or power-actuated fasteners Alternative support attachment on many projects
  • Sidelap fasteners — button punch, screw, or weld Deck sheet to adjacent deck sheet, at the specified spacing

Sidelap fasteners are the most commonly shorted item in the field and one of the most consequential: without them, adjacent sheets slide relative to one another and the diaphragm does not develop its rated shear.

Shear studs on composite beams are welded through the deck to the beam flange in the number and pattern the drawings specify. Miscounting studs is a capacity reduction that is invisible after the slab is poured.