Study guide
10.3 Energy Code & Accessibility
Arizona General Contractor Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Introduction & Exam Overview
1.1 Current Exam Facts 1.2 The Arizona Contractor Licensing Path 1.3 How to Use This Guide & Study Plan
2 Chapter 2: Arizona ROC & Licensing Law
2.1 The Arizona Registrar of Contractors 2.2 License Classifications 2.3 Qualifying Party & Experience Requirements 2.4 Application, Fees, Bond & Background Check 2.5 License Bonds, Cash Deposits & Bond Claims 2.6 Unlicensed Contracting: Penalties & Lost Remedies 2.7 Advertising Rules, Contract Disclosures & Workmanship Standards
3 Chapter 3: The Exams — SRE, Trade & NASCLA
3.1 The Statutes & Rules Exam (SRE) 3.2 The PSI Trade Exam 3.3 The NASCLA Commercial General Building Exam Option
4 Chapter 4: License Maintenance, Recovery Fund & Discipline
4.1 License Renewal & Continuing Education 4.2 The Residential Contractors' Recovery Fund 4.3 ROC Disciplinary Actions & Penalties
5 Chapter 5: Contract Law & Disputes
5.1 Arizona Contract Fundamentals 5.2 Construction Contract Terms & Provisions 5.3 Change Orders & Modifications 5.4 Dispute Resolution & ROC Complaints 5.5 The Arizona Prompt Payment Act
6 Chapter 6: Liens, Bonds & Insurance
6.1 Arizona Mechanics' Lien Law Overview 6.2 Lien Notices, Recording & Deadlines 6.3 Contract Bonds: Bid, Performance & Payment 6.4 Insurance Requirements
7 Chapter 7: Financial Management & Taxes
7.1 Accounting & Financial Statements 7.2 Estimating, Bidding & Markup 7.3 Taxes & Payroll
8 Chapter 8: Project Management
8.1 Scheduling & the Critical Path Method 8.2 Supervision, Subcontractors & Quality Control 8.3 Project Documentation & Closeout
9 Chapter 9: Safety & OSHA
9.1 OSHA Construction Standards Overview 9.2 Fall Protection, Scaffolds & Ladders 9.3 Excavation, Trenching & Electrical Safety 9.4 Heat Illness Prevention & Arizona Job-Site Hazards
10 Chapter 10: Building Codes, Permits & Plan Reading
10.1 IRC 2018 & IBC 2018 Fundamentals 10.2 Permits, Plan Review & Inspections 10.3 Energy Code & Accessibility 10.4 Reading Construction Drawings & Specifications 10.5 Means of Egress & Fire-Resistance-Rated Construction
11 Chapter 11: Sitework, Concrete & Masonry
11.1 Sitework: Surveying, Excavation & Grading 11.2 Concrete: Formwork, Reinforcement & Placing 11.3 Masonry: Brick, Block & Mortar 11.4 Soils, Compaction & Earthwork Testing 11.5 Concrete Materials & Mix Design 11.6 Concrete Curing, Joints, Testing & Defects 11.7 Masonry Reinforcement, Grouting & Wall Systems
12 Chapter 12: Carpentry, Metals & Building Envelope
12.1 Carpentry & Framing 12.2 Metals & Metal Framing 12.3 Thermal & Moisture Protection 12.4 Doors, Windows & Finishes 12.5 Engineered Wood, Trusses & Connectors 12.6 Structural Steel Erection & Connections 12.7 Steel Joists, Girders & Metal Deck
13 Chapter 13: Roofing, Waterproofing & Interior Finishes
13.1 Roofing Systems 13.2 Waterproofing, Flashing & Sealants 13.3 Interior Finishes: Gypsum, Stucco, Flooring & Paint
14 Chapter 14: Building Systems for the General Contractor
14.1 Mechanical & Plumbing Systems 14.2 Electrical Systems & Temporary Power
10.3 Energy Code & Accessibility
Key Takeaways Explain This Topic AI
The IECC (International Energy Conservation Code) sets minimum R-values, maximum U-factors and SHGC, and duct leakage limits by climate zone
Arizona jurisdictions adopt the IECC locally; the state spans climate zones 2 through 5 depending on elevation
Commercial buildings must comply with federal ADA Standards and IBC Chapter 11 accessibility provisions (incorporating ICC A117.1)
The IECC prescriptive path is the simplest compliance method for small residential projects; performance and ERI paths require modeling or a certified rater
On the B-1/B-2 open-book exam, expect both IECC commercial provisions and IBC Chapter 11 accessibility questions
Last updated: August 2026
IECC Energy Code Provisions
The International Energy Conservation Code (IECC) is the ICC model energy code. Like the IRC and IBC, it is adopted locally by Arizona cities and counties , so the edition in force depends on the jurisdiction. The IECC contains a residential chapter (for one- and two-family dwellings regulated by the IRC) and a commercial chapter (for buildings regulated by the IBC).
Key IECC Requirements
- Requirement Typical IECC Provision
- Building envelope insulation Minimum R-values for walls, ceilings/attics, and floors based on climate zone
- Fenestration (windows/skylights) Maximum U-factor and Solar Heat Gain Coefficient (SHGC)
- Air leakage Continuous air barrier; blower-door testing to verify leakage limits
- Duct leakage Ducts in unconditioned spaces must be sealed and tested; total leakage limits per code edition
- Lighting High-efficacy lamps in permanent fixtures; commercial lighting power density limits
- HVAC equipment efficiency Minimum SEER/HSPF/AFUE referenced to federal standards
- Service water heating Insulated piping, efficient water heaters
Arizona spans IECC climate zones 2 through 5 depending on elevation — Phoenix (Zone 2, hot-dry) and Flagstaff (Zone 5, cold) have very different envelope requirements. The trade exam may test your ability to look up the correct R-value or U-factor from the IECC climate-zone table.
Compliance Paths
The IECC offers multiple compliance paths:
Prescriptive — follow a table of minimum R-values and maximum U-factors directly (simplest, most common for residential)
- Performance — use software to show the proposed building meets an annual energy cost or energy use target
- Energy Rating Index (ERI) — demonstrate a target HERS score through a certified energy rater
Most small residential projects use the prescriptive path because it is straightforward: look up the climate zone, read the table, and build to the listed values. Commercial projects often use the performance path for design flexibility, especially when the building includes features that the prescriptive tables do not anticipate (large glazing areas, unusual HVAC configurations).
Accessibility: ADA and ICC A117.1
Commercial buildings must comply with accessibility standards that ensure people with disabilities can enter and use the facility. Two frameworks apply:
Americans with Disabilities Act (ADA) — federal civil rights law (1990). The ADA Standards for Accessible Design specify accessible routes, parking, entrances, restrooms, and reach ranges. ADA compliance is a federal legal requirement independent of any local code adoption.
ICC A117.1 — the model standard referenced by the IBC Chapter 11 for accessible design and technical criteria (door widths, grab-bar heights, ramp slopes, turning spaces). The IBC incorporates A117.1 by reference.
Key Accessibility Requirements (Commercial)
- Feature Requirement
- Accessible route Continuous, unobstructed path from site arrival to building entry and throughout the facility
Ramps Slope not steeper than 1:12; level landings at intervals; handrails on both sides for rises over 6 inches
- Door clear width Minimum 32 inches clear opening
- Parking Accessible spaces required based on total count; at least one van-accessible space
- Restrooms Accessible stalls, grab bars, 60-inch turning circle, reach ranges for controls
- Signage Tactile and visual signage for permanent rooms and spaces
- How These Appear on the Trade Exam
- Residential vs Commercial Energy Compliance
The IECC residential chapter applies to one- and two-family dwellings and townhouses regulated by the IRC. It focuses on the building envelope, duct sealing, and equipment efficiency, and is typically satisfied with the prescriptive path. The commercial chapter applies to all other buildings and adds requirements for building envelope sealing , mechanical system commissioning on larger systems, lighting power density limits by space type, and manual lighting controls or occupancy sensors. Commercial energy compliance often involves the COMcheck software tool to demonstrate performance-path compliance, while residential projects use the simpler REScheck tool or a prescriptive worksheet.
ADA vs ICC A117.1 — How They Relate
The ADA is a federal civil rights statute enforced by the Department of Justice; compliance is mandatory regardless of local code adoption. ICC A117.1 is a technical standard that provides the specific dimensional criteria (grab-bar heights, turning circles, reach ranges) that the IBC references in Chapter 11. In practice, designing to IBC Chapter 11 and A117.1 typically satisfies the ADA Standards as well, but the two are legally independent — a building can meet code and still face an ADA complaint if an accessible route or element is missing.
For the B trade exam (residential), energy code questions are most likely and accessibility is minimal — the IRC Chapter 11 (RECA) covers residential energy efficiency. For the B-1/B-2 commercial exam , expect both IECC commercial provisions and IBC Chapter 11 accessibility questions. Because the 2018 IBC is open-book , practice finding accessibility tables (reach ranges, door widths, ramp slopes) quickly in Chapter 11 and the referenced A117.1 tables. Know the difference between the federal ADA obligation (always applies) and the code-referenced A117.1 technical criteria (enforced through the local permit and inspection process).
What to Practice for the Open-Book Exam
For both exams, learn to look up values in tables quickly. Residential candidates should practice finding climate-zone R-value and U-factor tables in the IECC residential chapter and the IRC Chapter 11 energy provisions. Commercial candidates should practice navigating IBC Chapter 11 accessibility tables — reach ranges, door clear widths, ramp slopes — and the IECC commercial envelope requirements. Know that the ADA is a federal obligation that applies with or without a local permit, while A117.1 is enforced through the plan-review and inspection process. When a question asks whether a specific feature is required, check both the general rule and any exception beneath it before answering.
Quick Answer: The IECC prescriptive path is the fastest residential energy compliance route. For commercial, plan to look up accessibility criteria in IBC Chapter 11 and A117.1 during the open-book exam.