Study guide

1.2 Facility Classification & Operator in Direct Responsible Charge (ODRC)

Arizona Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Arizona Regulatory Framework & ADEQ Certification

1.1 ADEQ Operator Certification Rules & Grade Structure 1.2 Facility Classification & Operator in Direct Responsible Charge (ODRC) 1.3 Arizona Aquifer Protection Permit (APP) Program & BADCT 1.4 AZPDES Surface Water Discharges & Arizona Reclaimed Water Standards 1.5 The WPI Need-to-Know Criteria: What Is Actually on Your Exam

2 Chapter 2: Federal Drinking Water & Clean Water Act Compliance

2.1 Safe Drinking Water Act (SDWA) Primary & Secondary MCLs 2.2 Surface Water Treatment Rules & Revised Total Coliform Rule (RTCR) 2.3 Stage 1 & Stage 2 Disinfectants/Disinfection Byproducts Rules (D/DBPR)

3 Chapter 3: Source Water Assessment, Wells & Watershed Protection

3.1 Groundwater Sources, Well Components & Water Level Measurement 3.2 Surface Water Sources, Intakes & Reservoir Management 3.3 Watershed Management, Contamination Sources & Public Education 3.4 Pretreatment: Aeration, Presedimentation & Algae Control

4 Chapter 4: Source Water Quality, Coagulation & Flocculation

4.1 Arizona Source Water Quality & Arid Climate Challenges 4.2 Coagulation Chemistry, Coagulants & Jar Testing 4.3 Flocculation Basin Design & Process Control 4.4 Sedimentation Basins, Clarifiers & Solids Contact Units

5 Chapter 5: Filtration Systems & Advanced Separation

5.1 Granular Media Filtration Principles & Media Types 5.2 Filter Backwash Operations, Ripening & Filter-to-Waste 5.3 Membrane Filtration & Reverse Osmosis Desalination 5.4 Ion Exchange Softening, Arsenic Removal & GAC Adsorption

6 Chapter 6: Drinking Water Disinfection & Chemical Oxidation

6.1 Chlorine Chemistry & Break-Point Chlorination 6.2 The CT Disinfection Concept & Basin Hydraulics 6.3 Alternative Disinfectants: Chloramines, Ozone, UV & Chlorine Dioxide

7 Chapter 7: Specialized Drinking Water Treatment & Chemical Conditioning

7.1 Iron & Manganese Removal 7.2 Fluoridation: Chemicals, Dosage & Safety 7.3 Corrosion Control, Saturation Indices & the Lead and Copper Rule 7.4 Water Treatment Plant Residuals Handling & Disposal

8 Chapter 8: Water Treatment Plant Equipment Operation & Maintenance

8.1 Raw Water Intake, Screening & Pumping Equipment 8.2 Chemical Feed Equipment, Storage & Metering 8.3 Instrumentation, Online Analyzers, SCADA & Calibration 8.4 Valves, Motors, Auxiliary Systems & Maintenance Programs

9 Chapter 9: Wastewater Preliminary, Primary & Biological Treatment Principles

9.1 Wastewater Characteristics & Preliminary Treatment 9.2 Primary Clarification Design & Settling Mechanics 9.3 Biological Treatment Kinetics & Microbiology

10 Chapter 10: Activated Sludge Processes & Nutrient Removal

10.1 Activated Sludge Configurations & Operational Mass Balance 10.2 Process Control Parameters, Settleability & Troubleshooting 10.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal

11 Chapter 11: Fixed-Film, Lagoon & Advanced Secondary Processes

11.1 Trickling Filters & Attached Growth Fundamentals 11.2 Rotating Biological Contactors & Hybrid Processes 11.3 Stabilization Ponds & Lagoon Systems 11.4 Membrane Bioreactors

12 Chapter 12: Tertiary Treatment, Wastewater Disinfection & Effluent Management

12.1 Tertiary Filtration & Advanced Effluent Polishing 12.2 Wastewater Chlorination & Dechlorination 12.3 Ultraviolet & Ozone Disinfection of Wastewater 12.4 Effluent Disposal, Reclaimed Water Reuse & Permit Compliance

13 Chapter 13: Residuals Management & Sludge Processing

13.1 Sludge Thickening & Digestion Processes 13.2 Sludge Dewatering Technologies & Drying Beds 13.3 EPA Part 503 Biosolids Rules & Arizona Beneficial Use

14 Chapter 14: Wastewater Plant Equipment Operation & Maintenance

14.1 Preliminary & Primary Treatment Equipment 14.2 Aeration Systems, Blowers, Diffusers & Dissolved Oxygen Control 14.3 Wastewater Pumps, Mixers & Chemical Dosing Equipment 14.4 Electrical Systems, Online Analyzers & Auxiliary Power

15 Chapter 15: Water Distribution Infrastructure & Hydraulic Management

15.1 Water Main Materials, Fittings & Appurtenances 15.2 Water Storage, Pressure Management & Water Age 15.3 Cross-Connection Control & Backflow Prevention 15.4 Main Maintenance, Unidirectional Flushing & Leak Detection 15.5 Distribution Hydraulics, Head Loss & C-Factor 15.6 System Mapping, GIS, Plans & Distribution SCADA

16 Chapter 16: Water Main Installation, Repair & Disinfection

16.1 Main & Service Line Installation, Tapping & Thrust Restraint 16.2 New Construction Inspection, Pressure Testing & Utility Locating 16.3 Disinfection of Mains, Storage Facilities & Repaired Components 16.4 Booster Stations, Meters & Storage Facility Inspection

17 Chapter 17: Distribution Water Quality Management & Field Testing

17.1 Distribution Chemical Feed, Dosage Adjustment & Booster Chlorination 17.2 Distribution Sampling Programs & Field Analyses 17.3 Chemical Transport, Storage & Handling in Distribution Operations 17.4 Interpreting Water Quality Data, Complaints & Nitrification Control

18 Chapter 18: Wastewater Collection Systems & Lift Stations

18.1 Gravity Sewer Design, Piping Materials & Manholes 18.2 Inflow & Infiltration (I&I) Assessment & Pipeline Rehabilitation 18.3 Wastewater Lift Stations, Pump Types & Force Mains 18.4 Hydrogen Sulfide Corrosion, Odor Control & Line Cleaning 18.5 Excavation, Heavy Equipment & Surface Restoration

19 Chapter 19: Collection System Cleaning, Inspection & Rehabilitation

19.1 Hydraulic Cleaning, Rodding & Blockage Removal 19.2 CCTV Inspection, Condition Assessment & FOG Control 19.3 Trenchless Rehabilitation: CIPP, Pipe Bursting & Lining 19.4 SSO Response, Flow Monitoring & Capacity Assurance

20 Chapter 20: Laboratory Testing, Quality Control & Monitoring

20.1 Drinking Water Analytical Methods & Compliance Testing 20.2 Wastewater Laboratory Analytics & Process Control Tests 20.3 Sampling Protocols, Chain of Custody & Laboratory QA/QC 20.4 Emerging Contaminants, PFAS & Advanced Analytical Methods

21 Chapter 21: Utility Safety Programs & Emergency Preparedness

21.1 Lockout/Tagout, Electrical Safety & Arc Flash 21.2 Personal Protective Equipment, Fall Protection & Bloodborne Pathogens 21.3 Traffic Control & Work Zone Safety 21.4 Emergency Response Planning & Disaster Recovery 21.5 Heat Illness Prevention, Respiratory Protection & Hearing Conservation

22 Chapter 22: Security, Administration & Utility Management

22.1 Facility Security, Vulnerability Assessment & Cybersecurity 22.2 Recordkeeping, Standard Operating Procedures & Regulatory Reporting 22.3 Budgets, Procurement, Cost Analysis & Capital Improvement Planning 22.4 Asset Management, Energy Optimization & Water Loss Control 22.5 Supervision, Training, Customer Service & Public Communication

23 Chapter 23: Applied Operator Mathematics, Pumping Hydraulics & Utility Safety

23.1 Chemical Feed Calculations & Dosage Problem Solving 23.2 Geometric Volumes, Hydraulic Loading & Detention Time Math 23.3 Pumping Mechanics, System Head & Horsepower Calculations 23.4 Plant Safety: Confined Spaces, Chemical Hazards & OSHA Standards 23.5 Unit Conversions & Using the Supplied Formula/Conversion Table 23.6 Percent Removal, Process Efficiency & Solution Blending

1.2 Facility Classification & Operator in Direct Responsible Charge (ODRC)

Key Takeaways Explain This Topic AI

Arizona classifies water treatment plants, distribution systems, wastewater treatment facilities, and collection networks into Grades 1 through 4 based on design capacity, population served, and process complexity.

Every regulated facility must designate an Operator in Direct Responsible Charge (ODRC) certified at or above the facility's classification grade in the relevant discipline.

A substitute operator certified one grade lower than the facility may only oversee operations temporarily for up to 30 consecutive days (and no more than 60 cumulative days per year) with ADEQ notification.

Daily operational logbooks are permanent legal compliance records that must be bound with pre-numbered pages (or tamper-evident digital systems), retained for at least 3 years, and made immediately available for ADEQ inspection.

Under A.A.C. R18-5-115, ADEQ possesses statutory authority to suspend or revoke an operator's certification for gross negligence, incompetence, or willful falsification of compliance logs and reports.

Last updated: September 2026

1.2 Facility Classification & Operator in Direct Responsible Charge (ODRC)

Important

The ODRC Mandate : Arizona Administrative Code (A.A.C.) Title 18, Chapter 5, Article 1 mandates that every regulated public water system and wastewater treatment facility must officially designate at least one Operator in Direct Responsible Charge (ODRC). The designated ODRC must hold an active ADEQ certification equal to or exceeding the facility's classification grade in the appropriate operational discipline.

Facility classification establishes a legal alignment between the engineering complexity of a utility and the qualifications of the personnel responsible for its operation. An underspecified or improperly supervised treatment facility poses immediate risks to public health and the environment. ADEQ's classification matrices evaluate treatment technologies, flow volumes, chemical hazards, and population served to assign each facility a Grade from 1 to 4.

Facility Classification Matrices

Facility classification is governed by point-rating and threshold matrices set forth in A.A.C. Title 18, Chapter 5. The parameters differ across water treatment, water distribution, wastewater treatment, and wastewater collection.

1. Water Treatment Plants (WTP)

Water treatment classification is driven by the source water type (groundwater vs. surface water), raw water quality variability, design hydraulic capacity in Million Gallons per Day (MGD), and the complexity of chemical additions and physical separation processes.

Classification Grade Source Water & Treatment Technology Profile Flow Capacity Limits

Grade 1 Groundwater with simple disinfection (liquid sodium hypochlorite or gas chlorination); no filtration or chemical coagulation. All flows, provided treatment is limited to basic disinfection

Grade 2 Groundwater with chemical addition (sequestration, fluoridation, pH adjustment) or small surface water plants using package filtration. Design flow < 1.0 MGD for surface water or complex groundwater

Grade 3 Conventional surface water treatment (coagulation, flocculation, sedimentation, granular dual-media filtration); or complex groundwater plants with arsenic adsorption or ion exchange. Design flow between 1.0 MGD and 5.0 MGD for conventional surface water

Grade 4 Advanced surface water treatment incorporating ozone, membrane filtration (microfiltration, ultrafiltration, nanofiltration, reverse osmosis), granular activated carbon (GAC) contractors, or high-rate clarification. Design flow > 5.0 MGD; OR any facility using advanced multi-barrier processes

2. Water Distribution Systems (WD)

Water distribution system classification focuses primarily on the population served, hydraulic pressure management, storage configurations, and booster pumping complexity.

  • Classification Grade Population Served Threshold Infrastructure Characteristics
  • Grade 1 ≤ 1,499 persons Single pressure zone, gravity storage or hydropneumatic tank, basic booster station

Grade 2 1,500 to 15,000 persons Multiple pressure zones, elevated storage tanks, automated control valves (PRVs)

Grade 3 15,001 to 50,000 persons Complex multi-zone hydraulic topology, extensive booster stations, chloramine booster stations

Grade 4 > 50,000 persons Regional metropolitan networks, automated SCADA flow-pacing, multiple wholesale interties

3. Wastewater Treatment Plants (WWTP)

Wastewater facilities are classified based on influent raw wastewater strength, design hydraulic flow (MGD), receiving water sensitivity (APP groundwater recharge vs. AZPDES surface water discharge), and biological process complexity.

Classification Grade Treatment Technology & Process Profile Flow Capacity Limits

Grade 1 Facultative stabilization ponds, aerated lagoons, land application with minimal mechanical equipment. Design flow < 0.1 MGD

Grade 2 Fixed-film biological systems (trickling filters, rotating biological contactors), small extended aeration plants. Design flow 0.1 MGD to 1.0 MGD

Grade 3 Conventional activated sludge, sequencing batch reactors (SBRs), tertiary sand filters, biological nutrient removal (BNR). Design flow 1.0 MGD to 5.0 MGD

Grade 4 Advanced water reclamation facilities (WRFs), membrane bioreactors (MBR), microfiltration/RO, full denitrification, anaerobic digesters with biogas recovery. Design flow > 5.0 MGD; OR any advanced reclamation facility

4. Wastewater Collection Systems (WWC)

Collection networks are classified by population served, pipeline diameters, flow capacity, and the presence of lift stations and force mains.

Grade 1 : Population ≤ 1,499; simple gravity systems with zero lift stations.

Grade 2 : Population 1,500 to 15,000; or gravity systems with 1 to 2 lift stations.

Grade 3 : Population 15,001 to 50,000; multiple regional lift stations, force mains, and inverted siphons.

Grade 4 : Population > 50,000; extensive metropolitan interceptors, complex telemetry, and high-head pumping stations.

Designation & Responsibilities of the ODRC

The Operator in Direct Responsible Charge (ODRC) is the designated certified professional legally accountable for the daily operation of a facility. The facility owner must submit an official designation form to ADEQ naming the primary ODRC and any designated backups. +-----------------------------------------------------------------------------------+

  • | Core Responsibilities of the ODRC |
  • +-----------------------------------------------------------------------------------+
  • | 1. Daily Process Decisions | Set chemical dosages, filter run cycles, return |
  • | | sludge rates (RAS), and waste rates (WAS). |
  • | 2. Regulatory Compliance | Ensure strict adherence to NPDWRs, APP permits, |
  • | | AZPDES effluent limits, and monitoring schedules.|
  • | 3. Operational Logbooks | Maintain permanent, tamper-evident daily logs of |
  • | | all inspections, calibrations, and adjustments. |
  • | 4. Emergency Management | Lead response to line breaks, power outages, |
  • | | chemical spills, and unpermitted discharges. |
  • | 5. Staff Supervision | Direct and supervise shift operators, mechanics, |
  • | | and laboratory personnel. |
  • +-----------------------------------------------------------------------------------+
  • Shift & Substitute Operator Requirements

Operating utilities require 24/7 oversight or scheduled shift staffing. ADEQ rules delineate strict boundaries regarding who can make operational decisions:

Shift Operators : Personnel on duty during specific operating shifts must be certified, but they may hold a certification grade lower than the facility classification, provided they execute standard operating procedures (SOPs) established by the ODRC.

Substitute ODRC Provisions : When the primary ODRC is absent due to illness, vacation, or emergency, a designated substitute operator must assume responsibility.

An operator certified at or above the facility grade can serve as substitute indefinitely.

An operator certified one grade below the facility classification may serve as substitute for a temporary period not to exceed 30 consecutive calendar days , or no more than 60 cumulative calendar days in a single year .

The facility owner must formally notify ADEQ in writing if a lower-grade substitute serves as ODRC.

Loading diagram... Facility Governance, ODRC Oversight, and Staffing Hierarchy

Daily Operational Logbook Protocols

Under A.A.C. Title 18, Chapter 5, Article 1, every regulated facility must maintain a contemporaneous, permanent daily operational logbook. The logbook serves as an official legal record of facility operations, compliance verifications, and physical inspections.

Formatting and Integrity Standards

Physical Logbooks : Must be hard-bound with pre-numbered pages. Spiral notebooks, loose-leaf binders, or loose paper sheets are strictly prohibited to prevent page substitution or destruction.

Electronic Logbooks : Permitted only if the software incorporates automated, tamper-evident security controls. These include unique cryptographic user credentials, time-stamped entries, and an immutable audit trail that tracks any amendments or edits without erasing the original text.

Correction Protocols : If an error is entered in a physical logbook, the operator must draw a single horizontal line through the incorrect entry, write the correct text adjacent to it, and sign or initial and date the correction. The use of opaque correction fluid (white-out), erasures, or blacking out text is a violation of recordkeeping rules.

Mandatory Daily Entries

The on-duty operator must record the following parameters daily:

Date, shift times, and names/certification grades of all operators on duty.

Water production and wastewater influent/effluent flow totals (in gallons or MGD).

Chemical inventories, deliveries, and daily consumption (pounds fed, feed rates, dose calculations).

Water quality test results (pH, free/total chlorine residual, turbidity, dissolved oxygen, MLSS).

Equipment status changes (pumps started/stopped, filters washed, clarifier drive inspections).

Calibration dates for process instrumentation (turbidimeters, pH probes, chlorine analyzers).

System anomalies, emergency alarms, power outages, and corrective actions taken.

Off-site regulatory sampling occurrences and chain-of-custody tracking numbers.

Record Retention & Inspection

Logbooks must be preserved on site and readily accessible for a minimum of 3 years from the date of the last entry (note that chemical and bacteriological compliance monitoring records must be retained for 5 to 10 years under SDWA and CWA mandates). During unannounced ADEQ sanitary surveys and compliance audits, the logbook is one of the primary documents reviewed by inspectors.

Remote Monitoring & Unattended Facility Protocols

Across Arizona, many rural well sites, booster pumping stations, and automated package wastewater plants operate unattended. ADEQ permits unattended operation only under strict engineering and operational constraints:

Automated SCADA Monitoring : Unattended facilities must be equipped with Supervisory Control and Data Acquisition (SCADA) systems that continuously monitor critical process setpoints.

Fail-Safe Alarm Telemetry : The system must have automated dialer capabilities that broadcast critical alarms (loss of chlorine residual, high filter turbidity, high wet well level, low distribution pressure, power failure) to the on-call certified operator.

Mandatory Physical Site Visits : Automated monitoring does not eliminate physical inspections. A certified operator must conduct scheduled physical site visits (typically daily or weekly, depending on facility grade and permit conditions) to verify equipment operation, log manual gauges, and conduct grab sampling.

On-Call Response Time : The designated on-call operator must reside within a geographic radius enabling physical arrival at the facility within 1 to 2 hours of receiving an emergency alarm.

Legal Liabilities & Disciplinary Proceedings under A.A.C. R18-5-115

Certified operators bear legal responsibility for public health and safety. Under A.A.C. R18-5-115, ADEQ possesses explicit statutory authority to investigate complaints, initiate administrative proceedings, and impose sanctions against certified individuals.

Grounds for Disciplinary Action

ADEQ may suspend, revoke, or refuse to renew an operator's certification upon finding that the operator has:

Fraud or Deceit : Obtained certification through fraudulent means, such as submitting false educational transcripts, forged experience verification letters, or cheating on examinations.

Gross Negligence : Demonstrated reckless disregard in the operation of a facility, leading to equipment destruction, extended distribution outages, or widespread contamination.

Incompetence : Consistently failed to exercise reasonable care or demonstrate technical competence in process control, chemical handling, or compliance reporting.

Willful Falsification : Deliberately falsified monitoring data, logbook entries, calibration records, or regulatory compliance submittals (such as Discharge Monitoring Reports).

Permit Non-Compliance : Willfully or repeatedly violated the provisions of the Safe Drinking Water Act, Aquifer Protection Permit, or AZPDES permit.

Administrative Hearings and Civil/Criminal Sanctions

Disciplinary proceedings adhere to Arizona administrative due process. ADEQ issues a formal Notice of Violation (NOV) or Notice of Intent to Revoke. The operator has the statutory right to request an evidentiary hearing before an independent Administrative Law Judge (ALJ) at the Arizona Office of Administrative Hearings (OAH). Following the hearing, the ALJ submits recommended findings to the ADEQ Director, who issues the final administrative order.

Beyond administrative certificate revocation, severe violations carry significant legal liability:

Civil Penalties : Under A.R.S. Title 49, civil penalties of up to $25,000 per day per violation may be assessed against facilities and responsible corporate/individual entities.

Criminal Prosecution : Knowing or intentional falsification of environmental compliance documents is classified as a Class 5 felony under Arizona Revised Statutes, exposing the individual to potential state imprisonment and criminal fines.