Study guide
23.6 Percent Removal, Process Efficiency & Solution Blending
Arizona Water/Wastewater Operator Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Arizona Regulatory Framework & ADEQ Certification
1.1 ADEQ Operator Certification Rules & Grade Structure 1.2 Facility Classification & Operator in Direct Responsible Charge (ODRC) 1.3 Arizona Aquifer Protection Permit (APP) Program & BADCT 1.4 AZPDES Surface Water Discharges & Arizona Reclaimed Water Standards 1.5 The WPI Need-to-Know Criteria: What Is Actually on Your Exam
2 Chapter 2: Federal Drinking Water & Clean Water Act Compliance
2.1 Safe Drinking Water Act (SDWA) Primary & Secondary MCLs 2.2 Surface Water Treatment Rules & Revised Total Coliform Rule (RTCR) 2.3 Stage 1 & Stage 2 Disinfectants/Disinfection Byproducts Rules (D/DBPR)
3 Chapter 3: Source Water Assessment, Wells & Watershed Protection
3.1 Groundwater Sources, Well Components & Water Level Measurement 3.2 Surface Water Sources, Intakes & Reservoir Management 3.3 Watershed Management, Contamination Sources & Public Education 3.4 Pretreatment: Aeration, Presedimentation & Algae Control
4 Chapter 4: Source Water Quality, Coagulation & Flocculation
4.1 Arizona Source Water Quality & Arid Climate Challenges 4.2 Coagulation Chemistry, Coagulants & Jar Testing 4.3 Flocculation Basin Design & Process Control 4.4 Sedimentation Basins, Clarifiers & Solids Contact Units
5 Chapter 5: Filtration Systems & Advanced Separation
5.1 Granular Media Filtration Principles & Media Types 5.2 Filter Backwash Operations, Ripening & Filter-to-Waste 5.3 Membrane Filtration & Reverse Osmosis Desalination 5.4 Ion Exchange Softening, Arsenic Removal & GAC Adsorption
6 Chapter 6: Drinking Water Disinfection & Chemical Oxidation
6.1 Chlorine Chemistry & Break-Point Chlorination 6.2 The CT Disinfection Concept & Basin Hydraulics 6.3 Alternative Disinfectants: Chloramines, Ozone, UV & Chlorine Dioxide
7 Chapter 7: Specialized Drinking Water Treatment & Chemical Conditioning
7.1 Iron & Manganese Removal 7.2 Fluoridation: Chemicals, Dosage & Safety 7.3 Corrosion Control, Saturation Indices & the Lead and Copper Rule 7.4 Water Treatment Plant Residuals Handling & Disposal
8 Chapter 8: Water Treatment Plant Equipment Operation & Maintenance
8.1 Raw Water Intake, Screening & Pumping Equipment 8.2 Chemical Feed Equipment, Storage & Metering 8.3 Instrumentation, Online Analyzers, SCADA & Calibration 8.4 Valves, Motors, Auxiliary Systems & Maintenance Programs
9 Chapter 9: Wastewater Preliminary, Primary & Biological Treatment Principles
9.1 Wastewater Characteristics & Preliminary Treatment 9.2 Primary Clarification Design & Settling Mechanics 9.3 Biological Treatment Kinetics & Microbiology
10 Chapter 10: Activated Sludge Processes & Nutrient Removal
10.1 Activated Sludge Configurations & Operational Mass Balance 10.2 Process Control Parameters, Settleability & Troubleshooting 10.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal
11 Chapter 11: Fixed-Film, Lagoon & Advanced Secondary Processes
11.1 Trickling Filters & Attached Growth Fundamentals 11.2 Rotating Biological Contactors & Hybrid Processes 11.3 Stabilization Ponds & Lagoon Systems 11.4 Membrane Bioreactors
12 Chapter 12: Tertiary Treatment, Wastewater Disinfection & Effluent Management
12.1 Tertiary Filtration & Advanced Effluent Polishing 12.2 Wastewater Chlorination & Dechlorination 12.3 Ultraviolet & Ozone Disinfection of Wastewater 12.4 Effluent Disposal, Reclaimed Water Reuse & Permit Compliance
13 Chapter 13: Residuals Management & Sludge Processing
13.1 Sludge Thickening & Digestion Processes 13.2 Sludge Dewatering Technologies & Drying Beds 13.3 EPA Part 503 Biosolids Rules & Arizona Beneficial Use
14 Chapter 14: Wastewater Plant Equipment Operation & Maintenance
14.1 Preliminary & Primary Treatment Equipment 14.2 Aeration Systems, Blowers, Diffusers & Dissolved Oxygen Control 14.3 Wastewater Pumps, Mixers & Chemical Dosing Equipment 14.4 Electrical Systems, Online Analyzers & Auxiliary Power
15 Chapter 15: Water Distribution Infrastructure & Hydraulic Management
15.1 Water Main Materials, Fittings & Appurtenances 15.2 Water Storage, Pressure Management & Water Age 15.3 Cross-Connection Control & Backflow Prevention 15.4 Main Maintenance, Unidirectional Flushing & Leak Detection 15.5 Distribution Hydraulics, Head Loss & C-Factor 15.6 System Mapping, GIS, Plans & Distribution SCADA
16 Chapter 16: Water Main Installation, Repair & Disinfection
16.1 Main & Service Line Installation, Tapping & Thrust Restraint 16.2 New Construction Inspection, Pressure Testing & Utility Locating 16.3 Disinfection of Mains, Storage Facilities & Repaired Components 16.4 Booster Stations, Meters & Storage Facility Inspection
17 Chapter 17: Distribution Water Quality Management & Field Testing
17.1 Distribution Chemical Feed, Dosage Adjustment & Booster Chlorination 17.2 Distribution Sampling Programs & Field Analyses 17.3 Chemical Transport, Storage & Handling in Distribution Operations 17.4 Interpreting Water Quality Data, Complaints & Nitrification Control
18 Chapter 18: Wastewater Collection Systems & Lift Stations
18.1 Gravity Sewer Design, Piping Materials & Manholes 18.2 Inflow & Infiltration (I&I) Assessment & Pipeline Rehabilitation 18.3 Wastewater Lift Stations, Pump Types & Force Mains 18.4 Hydrogen Sulfide Corrosion, Odor Control & Line Cleaning 18.5 Excavation, Heavy Equipment & Surface Restoration
19 Chapter 19: Collection System Cleaning, Inspection & Rehabilitation
19.1 Hydraulic Cleaning, Rodding & Blockage Removal 19.2 CCTV Inspection, Condition Assessment & FOG Control 19.3 Trenchless Rehabilitation: CIPP, Pipe Bursting & Lining 19.4 SSO Response, Flow Monitoring & Capacity Assurance
20 Chapter 20: Laboratory Testing, Quality Control & Monitoring
20.1 Drinking Water Analytical Methods & Compliance Testing 20.2 Wastewater Laboratory Analytics & Process Control Tests 20.3 Sampling Protocols, Chain of Custody & Laboratory QA/QC 20.4 Emerging Contaminants, PFAS & Advanced Analytical Methods
21 Chapter 21: Utility Safety Programs & Emergency Preparedness
21.1 Lockout/Tagout, Electrical Safety & Arc Flash 21.2 Personal Protective Equipment, Fall Protection & Bloodborne Pathogens 21.3 Traffic Control & Work Zone Safety 21.4 Emergency Response Planning & Disaster Recovery 21.5 Heat Illness Prevention, Respiratory Protection & Hearing Conservation
22 Chapter 22: Security, Administration & Utility Management
22.1 Facility Security, Vulnerability Assessment & Cybersecurity 22.2 Recordkeeping, Standard Operating Procedures & Regulatory Reporting 22.3 Budgets, Procurement, Cost Analysis & Capital Improvement Planning 22.4 Asset Management, Energy Optimization & Water Loss Control 22.5 Supervision, Training, Customer Service & Public Communication
23 Chapter 23: Applied Operator Mathematics, Pumping Hydraulics & Utility Safety
23.1 Chemical Feed Calculations & Dosage Problem Solving 23.2 Geometric Volumes, Hydraulic Loading & Detention Time Math 23.3 Pumping Mechanics, System Head & Horsepower Calculations 23.4 Plant Safety: Confined Spaces, Chemical Hazards & OSHA Standards 23.5 Unit Conversions & Using the Supplied Formula/Conversion Table 23.6 Percent Removal, Process Efficiency & Solution Blending
23.6 Percent Removal, Process Efficiency & Solution Blending
Key Takeaways Explain This Topic AI
Percent removal is the quantity removed divided by the quantity entering, and the denominator is always the influent value.
Loading calculations use the pounds formula, and removal expressed in pounds per day is often more meaningful than a percentage.
The dilution relationship C1V1 equals C2V2 solves both dilution and blending problems as long as the units are consistent.
A weighted average blending calculation must weight each stream by its flow, not by simply averaging the concentrations.
Wire-to-water efficiency is the product of pump efficiency and motor efficiency and is always lower than either individually.
Last updated: September 2026
23.6 Percent Removal, Process Efficiency & Solution Blending
Percent Removal % Removal = In − Out In × 100 \% \text{ Removal} = \frac{\text{In} - \text{Out}}{\text{In}} \times 100 % Removal = In In − Out × 100
The denominator is always the influent value. Dividing by the effluent is the single most common error and, on a multiple-choice exam, it lands on an answer choice that was placed there for exactly that reason.
Worked example. Primary influent BOD is 260 mg/L; primary effluent is 165 mg/L. 260 − 165 260 × 100 = 95 260 × 100 = 36.5 % \frac{260 - 165}{260} \times 100 = \frac{95}{260} \times 100 = 36.5\% 260 260 − 165 × 100 = 260 95 × 100 = 36.5%
That figure is typical for primary clarification, which normally removes about 25 to 40 percent of BOD and 50 to 70 percent of suspended solids.
Removal in Pounds
A percentage says nothing about the actual load a process handled. Pounds are what matter for design and for troubleshooting. lb/day removed = ( In − Out ) × Flow (MGD) × 8.34 \text{lb/day removed} = (\text{In} - \text{Out}) \times \text{Flow (MGD)} \times 8.34 lb/day removed = ( In − Out ) × Flow (MGD) × 8.34
Worked example. Using the values above at 3.8 MGD: 95 × 3.8 × 8.34 = 3,011 lb BOD/day removed 95 \times 3.8 \times 8.34 = 3{,}011\text{ lb BOD/day removed} 95 × 3.8 × 8.34 = 3 , 011 lb BOD/day removed
Important
Percent removal and pounds removed can move in opposite directions. If flow doubles while percent removal holds constant, the process is handling twice the load. Conversely a plant whose percent removal drops during a low-flow, low-strength period may be removing the same pounds as always. Always ask which one the question is about.
Overall Plant Removal
Overall removal is calculated from the plant influent and final effluent , not by adding the removals of the individual processes.
Worked example. Influent 240 mg/L BOD, primary effluent 155 mg/L, final effluent 12 mg/L.
- Primary removal: (240 − 155) ÷ 240 × 100 = 35.4%
- Secondary removal: (155 − 12) ÷ 155 × 100 = 92.3%
- Overall: (240 − 12) ÷ 240 × 100 = 95.0%
Note that 35.4 + 92.3 = 127.7, which is obviously wrong. Removals in series do not add , because each stage acts on what remains after the previous one.
Mass Balance
The principle: what goes in must come out or accumulate. In = Out + Accumulation \text{In} = \text{Out} + \text{Accumulation} In = Out + Accumulation
Worked example — solids balance. A plant receives 2,900 lb/day of solids in the influent and discharges 180 lb/day in the effluent. How much must be removed as sludge? 2,900 − 180 = 2,720 lb/day 2{,}900 - 180 = 2{,}720\text{ lb/day} 2 , 900 − 180 = 2 , 720 lb/day
If the plant is actually wasting only 2,100 lb/day, the difference of 620 lb/day is accumulating in the system — building inventory in the aeration basin or the clarifier blanket — and the operator has a developing problem that a single day's data would not reveal.
Solids in a sludge stream: lb/day = Flow (MGD) × 8.34 × % Solids × 10,000 \text{lb/day} = \text{Flow (MGD)} \times 8.34 \times \% \text{ Solids} \times 10{,}000 lb/day = Flow (MGD) × 8.34 × % Solids × 10 , 000
Because 1 percent equals 10,000 mg/L, this is the pounds formula with the percentage converted to a concentration.
Worked example. 0.028 MGD of sludge at 3.4 percent solids: 0.028 × 8.34 × 3.4 × 10,000 = 7,940 lb/day 0.028 \times 8.34 \times 3.4 \times 10{,}000 = 7{,}940\text{ lb/day} 0.028 × 8.34 × 3.4 × 10 , 000 = 7 , 940 lb/day
- Dilution and Blending
- The Dilution Relationship C 1 V 1 = C 2 V 2 C_1 V_1 = C_2 V_2 C 1 V 1 = C 2 V 2
Worked example. How much 12.5 percent sodium hypochlorite is needed to make 400 gallons of 1.0 percent solution? 12.5 × V 1 = 1.0 × 400 12.5 \times V_1 = 1.0 \times 400 12.5 × V 1 = 1.0 × 400 V 1 = 400 12.5 = 32 gallons V_1 = \frac{400}{12.5} = 32\text{ gallons} V 1 = 12.5 400 = 32 gallons
Add 32 gallons of the 12.5 percent solution and dilute to 400 gallons total — not add 400 gallons of water to it. The distinction between "dilute to" and "add to" is a standard trap.
Blending Two Streams C blend = ( C 1 × Q 1 ) + ( C 2 × Q 2 ) Q 1 + Q 2 C_{\text{blend}} = \frac{(C_1 \times Q_1) + (C_2 \times Q_2)}{Q_1 + Q_2} C blend = Q 1 + Q 2 ( C 1 × Q 1 ) + ( C 2 × Q 2 )
Warning
This is a flow-weighted average, not a simple average. Averaging the two concentrations directly is correct only when the two flows happen to be equal, and the exam reliably includes the simple average as a distractor.
Worked example. A utility blends 1.8 MGD of well water at 1,450 mg/L TDS with 4.2 MGD of surface water at 380 mg/L TDS. C = ( 1,450 × 1.8 ) + ( 380 × 4.2 ) 1.8 + 4.2 = 2,610 + 1,596 6.0 = 4,206 6.0 = 701 mg/L C = \frac{(1{,}450 \times 1.8) + (380 \times 4.2)}{1.8 + 4.2} = \frac{2{,}610 + 1{,}596}{6.0} = \frac{4{,}206}{6.0} = 701\text{ mg/L} C = 1.8 + 4.2 ( 1 , 450 × 1.8 ) + ( 380 × 4.2 ) = 6.0 2 , 610 + 1 , 596 = 6.0 4 , 206 = 701 mg/L
The simple average of 1,450 and 380 is 915 mg/L — meaningfully different, and wrong, because the lower-concentration stream carries more than twice the flow.
Blending is a real Arizona treatment strategy. Where a well exceeds a standard for arsenic, nitrate, or fluoride, blending it with a compliant source can bring the combined water into compliance, and the blend calculation is how the allowable ratio is determined.
Worked example — allowable blend. A well contains 0.018 mg/L arsenic against a maximum contaminant level of 0.010 mg/L, and the alternate source contains 0.002 mg/L. What fraction of the blend may come from the well?
Let x be the well fraction: 0.018 x + 0.002 ( 1 − x ) = 0.010 0.018x + 0.002(1-x) = 0.010 0.018 x + 0.002 ( 1 − x ) = 0.010 0.018 x + 0.002 − 0.002 x = 0.010 0.018x + 0.002 - 0.002x = 0.010 0.018 x + 0.002 − 0.002 x = 0.010 0.016 x = 0.008 ⇒ x = 0.50 0.016x = 0.008 \quad \Rightarrow \quad x = 0.50 0.016 x = 0.008 ⇒ x = 0.50
No more than 50 percent of the blend may come from the well , and prudent operation targets a margin below that rather than the exact limit.
Efficiency
Pump, Motor, and Wire-to-Water Water Horsepower = Flow (gpm) × Head (ft) 3,960 \text{Water Horsepower} = \frac{\text{Flow (gpm)} \times \text{Head (ft)}}{3{,}960} Water Horsepower = 3 , 960 Flow (gpm) × Head (ft) Brake Horsepower = WHP Pump Efficiency \text{Brake Horsepower} = \frac{\text{WHP}}{\text{Pump Efficiency}} Brake Horsepower = Pump Efficiency WHP Motor Horsepower = BHP Motor Efficiency \text{Motor Horsepower} = \frac{\text{BHP}}{\text{Motor Efficiency}} Motor Horsepower = Motor Efficiency BHP Wire-to-Water Efficiency = Pump Efficiency × Motor Efficiency \text{Wire-to-Water Efficiency} = \text{Pump Efficiency} \times \text{Motor Efficiency} Wire-to-Water Efficiency = Pump Efficiency × Motor Efficiency
Worked example. 1,100 gpm against 190 ft of total dynamic head, with a pump efficiency of 76 percent and a motor efficiency of 91 percent. WHP = 1,100 × 190 3,960 = 209,000 3,960 = 52.8 hp \text{WHP} = \frac{1{,}100 \times 190}{3{,}960} = \frac{209{,}000}{3{,}960} = 52.8\text{ hp} WHP = 3 , 960 1 , 100 × 190 = 3 , 960 209 , 000 = 52.8 hp BHP = 52.8 0.76 = 69.5 hp \text{BHP} = \frac{52.8}{0.76} = 69.5\text{ hp} BHP = 0.76 52.8 = 69.5 hp MHP = 69.5 0.91 = 76.4 hp \text{MHP} = \frac{69.5}{0.91} = 76.4\text{ hp} MHP = 0.91 69.5 = 76.4 hp Wire-to-water = 0.76 × 0.91 = 0.692 = 69.2 % \text{Wire-to-water} = 0.76 \times 0.91 = 0.692 = 69.2\% Wire-to-water = 0.76 × 0.91 = 0.692 = 69.2%
Important
Wire-to-water efficiency is always lower than either component efficiency , because the losses multiply rather than average. A pump at 76 percent driven by a motor at 91 percent delivers 69 percent of the electrical energy as useful water horsepower — nearly a third is lost. This is why pump efficiency testing is a genuine energy conservation measure and why it appears explicitly in the Need-to-Know Criteria as a scored task.
A Reasonableness Habit
Every efficiency must be less than 100 percent . Every percent removal must be between 0 and 100 . Any blended concentration must fall between the two input concentrations. Results outside those bounds mean the setup was wrong, and catching that takes two seconds.