Study guide

23.5 Unit Conversions & Using the Supplied Formula/Conversion Table

Arizona Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Arizona Regulatory Framework & ADEQ Certification

1.1 ADEQ Operator Certification Rules & Grade Structure 1.2 Facility Classification & Operator in Direct Responsible Charge (ODRC) 1.3 Arizona Aquifer Protection Permit (APP) Program & BADCT 1.4 AZPDES Surface Water Discharges & Arizona Reclaimed Water Standards 1.5 The WPI Need-to-Know Criteria: What Is Actually on Your Exam

2 Chapter 2: Federal Drinking Water & Clean Water Act Compliance

2.1 Safe Drinking Water Act (SDWA) Primary & Secondary MCLs 2.2 Surface Water Treatment Rules & Revised Total Coliform Rule (RTCR) 2.3 Stage 1 & Stage 2 Disinfectants/Disinfection Byproducts Rules (D/DBPR)

3 Chapter 3: Source Water Assessment, Wells & Watershed Protection

3.1 Groundwater Sources, Well Components & Water Level Measurement 3.2 Surface Water Sources, Intakes & Reservoir Management 3.3 Watershed Management, Contamination Sources & Public Education 3.4 Pretreatment: Aeration, Presedimentation & Algae Control

4 Chapter 4: Source Water Quality, Coagulation & Flocculation

4.1 Arizona Source Water Quality & Arid Climate Challenges 4.2 Coagulation Chemistry, Coagulants & Jar Testing 4.3 Flocculation Basin Design & Process Control 4.4 Sedimentation Basins, Clarifiers & Solids Contact Units

5 Chapter 5: Filtration Systems & Advanced Separation

5.1 Granular Media Filtration Principles & Media Types 5.2 Filter Backwash Operations, Ripening & Filter-to-Waste 5.3 Membrane Filtration & Reverse Osmosis Desalination 5.4 Ion Exchange Softening, Arsenic Removal & GAC Adsorption

6 Chapter 6: Drinking Water Disinfection & Chemical Oxidation

6.1 Chlorine Chemistry & Break-Point Chlorination 6.2 The CT Disinfection Concept & Basin Hydraulics 6.3 Alternative Disinfectants: Chloramines, Ozone, UV & Chlorine Dioxide

7 Chapter 7: Specialized Drinking Water Treatment & Chemical Conditioning

7.1 Iron & Manganese Removal 7.2 Fluoridation: Chemicals, Dosage & Safety 7.3 Corrosion Control, Saturation Indices & the Lead and Copper Rule 7.4 Water Treatment Plant Residuals Handling & Disposal

8 Chapter 8: Water Treatment Plant Equipment Operation & Maintenance

8.1 Raw Water Intake, Screening & Pumping Equipment 8.2 Chemical Feed Equipment, Storage & Metering 8.3 Instrumentation, Online Analyzers, SCADA & Calibration 8.4 Valves, Motors, Auxiliary Systems & Maintenance Programs

9 Chapter 9: Wastewater Preliminary, Primary & Biological Treatment Principles

9.1 Wastewater Characteristics & Preliminary Treatment 9.2 Primary Clarification Design & Settling Mechanics 9.3 Biological Treatment Kinetics & Microbiology

10 Chapter 10: Activated Sludge Processes & Nutrient Removal

10.1 Activated Sludge Configurations & Operational Mass Balance 10.2 Process Control Parameters, Settleability & Troubleshooting 10.3 Biological Nutrient Removal: Nitrification, Denitrification & Phosphorus Removal

11 Chapter 11: Fixed-Film, Lagoon & Advanced Secondary Processes

11.1 Trickling Filters & Attached Growth Fundamentals 11.2 Rotating Biological Contactors & Hybrid Processes 11.3 Stabilization Ponds & Lagoon Systems 11.4 Membrane Bioreactors

12 Chapter 12: Tertiary Treatment, Wastewater Disinfection & Effluent Management

12.1 Tertiary Filtration & Advanced Effluent Polishing 12.2 Wastewater Chlorination & Dechlorination 12.3 Ultraviolet & Ozone Disinfection of Wastewater 12.4 Effluent Disposal, Reclaimed Water Reuse & Permit Compliance

13 Chapter 13: Residuals Management & Sludge Processing

13.1 Sludge Thickening & Digestion Processes 13.2 Sludge Dewatering Technologies & Drying Beds 13.3 EPA Part 503 Biosolids Rules & Arizona Beneficial Use

14 Chapter 14: Wastewater Plant Equipment Operation & Maintenance

14.1 Preliminary & Primary Treatment Equipment 14.2 Aeration Systems, Blowers, Diffusers & Dissolved Oxygen Control 14.3 Wastewater Pumps, Mixers & Chemical Dosing Equipment 14.4 Electrical Systems, Online Analyzers & Auxiliary Power

15 Chapter 15: Water Distribution Infrastructure & Hydraulic Management

15.1 Water Main Materials, Fittings & Appurtenances 15.2 Water Storage, Pressure Management & Water Age 15.3 Cross-Connection Control & Backflow Prevention 15.4 Main Maintenance, Unidirectional Flushing & Leak Detection 15.5 Distribution Hydraulics, Head Loss & C-Factor 15.6 System Mapping, GIS, Plans & Distribution SCADA

16 Chapter 16: Water Main Installation, Repair & Disinfection

16.1 Main & Service Line Installation, Tapping & Thrust Restraint 16.2 New Construction Inspection, Pressure Testing & Utility Locating 16.3 Disinfection of Mains, Storage Facilities & Repaired Components 16.4 Booster Stations, Meters & Storage Facility Inspection

17 Chapter 17: Distribution Water Quality Management & Field Testing

17.1 Distribution Chemical Feed, Dosage Adjustment & Booster Chlorination 17.2 Distribution Sampling Programs & Field Analyses 17.3 Chemical Transport, Storage & Handling in Distribution Operations 17.4 Interpreting Water Quality Data, Complaints & Nitrification Control

18 Chapter 18: Wastewater Collection Systems & Lift Stations

18.1 Gravity Sewer Design, Piping Materials & Manholes 18.2 Inflow & Infiltration (I&I) Assessment & Pipeline Rehabilitation 18.3 Wastewater Lift Stations, Pump Types & Force Mains 18.4 Hydrogen Sulfide Corrosion, Odor Control & Line Cleaning 18.5 Excavation, Heavy Equipment & Surface Restoration

19 Chapter 19: Collection System Cleaning, Inspection & Rehabilitation

19.1 Hydraulic Cleaning, Rodding & Blockage Removal 19.2 CCTV Inspection, Condition Assessment & FOG Control 19.3 Trenchless Rehabilitation: CIPP, Pipe Bursting & Lining 19.4 SSO Response, Flow Monitoring & Capacity Assurance

20 Chapter 20: Laboratory Testing, Quality Control & Monitoring

20.1 Drinking Water Analytical Methods & Compliance Testing 20.2 Wastewater Laboratory Analytics & Process Control Tests 20.3 Sampling Protocols, Chain of Custody & Laboratory QA/QC 20.4 Emerging Contaminants, PFAS & Advanced Analytical Methods

21 Chapter 21: Utility Safety Programs & Emergency Preparedness

21.1 Lockout/Tagout, Electrical Safety & Arc Flash 21.2 Personal Protective Equipment, Fall Protection & Bloodborne Pathogens 21.3 Traffic Control & Work Zone Safety 21.4 Emergency Response Planning & Disaster Recovery 21.5 Heat Illness Prevention, Respiratory Protection & Hearing Conservation

22 Chapter 22: Security, Administration & Utility Management

22.1 Facility Security, Vulnerability Assessment & Cybersecurity 22.2 Recordkeeping, Standard Operating Procedures & Regulatory Reporting 22.3 Budgets, Procurement, Cost Analysis & Capital Improvement Planning 22.4 Asset Management, Energy Optimization & Water Loss Control 22.5 Supervision, Training, Customer Service & Public Communication

23 Chapter 23: Applied Operator Mathematics, Pumping Hydraulics & Utility Safety

23.1 Chemical Feed Calculations & Dosage Problem Solving 23.2 Geometric Volumes, Hydraulic Loading & Detention Time Math 23.3 Pumping Mechanics, System Head & Horsepower Calculations 23.4 Plant Safety: Confined Spaces, Chemical Hazards & OSHA Standards 23.5 Unit Conversions & Using the Supplied Formula/Conversion Table 23.6 Percent Removal, Process Efficiency & Solution Blending

23.5 Unit Conversions & Using the Supplied Formula/Conversion Table

Key Takeaways Explain This Topic AI

The formula and conversion table is supplied at the testing site, so the exam tests whether you can select and apply a formula rather than recall it.

Dimensional analysis cancels units through a calculation and is the most reliable defense against setting up a problem backward.

One million gallons per day equals 694.4 gallons per minute and 1.547 cubic feet per second, and these conversions appear constantly.

The 8.34 factor is pounds per gallon of water and is what converts a concentration in milligrams per liter into pounds per day.

WPI calculation items present US Standard units first and metric units in parentheses, and each problem must be solved entirely within one unit system.

Last updated: September 2026

23.5 Unit Conversions & Using the Supplied Formula/Conversion Table

ADEQ states plainly that formula and conversion sheets are supplied at the testing site and that non-programmable calculators are permitted. That single fact should reshape how you prepare: the exam is not testing whether you memorized the pounds formula. It is testing whether you can select the right formula and set the problem up correctly.

Download the WPI formula and conversion table from gowpi.org and practice with it until you know where each item sits on the page. An operator who has never seen the sheet before exam day loses time hunting for entries.

Dimensional Analysis: The Setup Check

The most common calculation error is not arithmetic — it is setting the problem up upside down. Dimensional analysis catches this by tracking units through the calculation.

Write each quantity with its units, arrange the conversion factors so that unwanted units cancel, and confirm that what remains is what the question asked for.

Example. Convert 850 gpm to MGD. 850 gal min × 1,440 min day × 1 MG 1,000,000 gal = 1.224 MGD 850\ \frac{\text{gal}}{\text{min}} \times 1{,}440\ \frac{\text{min}}{\text{day}} \times \frac{1\text{ MG}}{1{,}000{,}000\text{ gal}} = 1.224\text{ MGD} 850 min gal ​ × 1 , 440 day min ​ × 1 , 000 , 000 gal 1 MG ​ = 1.224 MGD

The minutes cancel, the gallons cancel, and million gallons per day remains. If you had divided by 1,440 instead, the units would not have resolved and the error would be visible before you finished.

Important

If the units do not cancel to the answer's units, the setup is wrong. This check costs seconds and catches the majority of calculation errors on an exam where every item is multiple choice and a wrong setup usually lands exactly on one of the distractors.

  • The Conversions Used Most
  • Volume
  • From To
  • 1 ft³ 7.48 gallons
  • 1 gallon 0.1337 ft³
  • 1 acre 43,560 ft²
  • 1 acre-foot 325,851 gallons
  • 1 gallon 3.785 liters
  • 1 ft³ 28.32 liters
  • Flow
  • From To
  • 1 MGD 694.4 gpm
  • 1 MGD 1.547 cfs
  • 1 cfs 448.8 gpm
  • 1 cfs 0.646 MGD
  • 1 gpm 1,440 gal/day
  • Weight and Pressure
  • From To
  • 1 gallon of water 8.34 lb
  • 1 ft³ of water 62.4 lb
  • 1 psi 2.31 ft of head
  • 1 ft of head 0.433 psi
  • 1 lb 453.6 grams
  • 1% 10,000 mg/L
  • Power
  • From To
  • 1 horsepower 746 watts
  • 1 hp 33,000 ft-lb/min
  • 1 kW 1.341 hp

Note

The 8.34 factor is the weight of a gallon of water in pounds , and it is what converts a concentration into a mass. Understanding why it appears rather than memorizing where it goes prevents most pounds-formula errors: milligrams per liter is a ratio, millions of gallons per day is a volume rate, and 8.34 pounds per gallon converts that volume into weight.

Geometry

  • Shape Formula
  • Circle area A = 0.785 × D 2 A = 0.785 \times D^2 A = 0.785 × D 2 or π r 2 \pi r^2 π r 2
  • Rectangle area A = L × W A = L \times W A = L × W
  • Triangle area A = 1 2 b h A = \frac{1}{2} b h A = 2 1 ​ bh
  • Cylinder volume V = 0.785 × D 2 × H V = 0.785 \times D^2 \times H V = 0.785 × D 2 × H
  • Rectangular volume V = L × W × D V = L \times W \times D V = L × W × D

Cone volume V = 1 3 × 0.785 × D 2 × H V = \frac{1}{3} \times 0.785 \times D^2 \times H V = 3 1 ​ × 0.785 × D 2 × H

  • Sphere volume V = 0.524 × D 3 V = 0.524 \times D^3 V = 0.524 × D 3
  • Circumference C = π D C = \pi D C = π D

Worked example — tank volume in gallons. A cylindrical tank 40 ft in diameter with 22 ft of water. V = 0.785 × 40 2 × 22 = 0.785 × 1,600 × 22 = 27,632 ft 3 V = 0.785 \times 40^2 \times 22 = 0.785 \times 1{,}600 \times 22 = 27{,}632\text{ ft}^3 V = 0.785 × 4 0 2 × 22 = 0.785 × 1 , 600 × 22 = 27 , 632 ft 3 27,632 × 7.48 = 206,687 gallons 27{,}632 \times 7.48 = 206{,}687\text{ gallons} 27 , 632 × 7.48 = 206 , 687 gallons

Worked example — pipe volume. 1,500 ft of 10-inch main. Convert diameter to feet: 10/12 = 0.833 ft. V = 0.785 × 0.833 2 × 1,500 = 0.785 × 0.694 × 1,500 = 817 ft 3 V = 0.785 \times 0.833^2 \times 1{,}500 = 0.785 \times 0.694 \times 1{,}500 = 817\text{ ft}^3 V = 0.785 × 0.83 3 2 × 1 , 500 = 0.785 × 0.694 × 1 , 500 = 817 ft 3 817 × 7.48 = 6,111 gallons 817 \times 7.48 = 6{,}111\text{ gallons} 817 × 7.48 = 6 , 111 gallons

Warning

Converting diameter from inches to feet is the single most common error in volume problems. A 10-inch pipe has a diameter of 0.833 ft , not 10 ft and not 0.10 ft. Every dimension in a formula using 7.48 gallons per cubic foot must be in feet.

A Systematic Approach to Word Problems

Read the question last line first. Know what is being asked before absorbing the data.

List the given values with their units.

Identify what is irrelevant. WPI deliberately includes unused data — recall the published example where a tank's 12-ft diameter is given but static pressure depends only on the 21-ft water level.

Select the formula from the supplied sheet.

Convert units so everything is consistent before substituting.

Substitute and solve.

Check the answer for reasonableness. A chlorine dose of 4,000 mg/L, a detention time of 0.02 minutes, or a pump efficiency of 340 percent are all signals of a setup error.

Confirm the units of the answer match what was requested.

Dual Units

WPI presents each calculation item in US Standard units first with metric in parentheses , and each is independently solvable.

Important

Pick one unit system and stay in it for the entire problem. Mixing feet with kilopascals or gallons with cubic meters partway through is the most self-inflicted error available on the exam. Read the whole problem in one system, ignore the parenthetical values entirely, and select the answer in the same system you worked in.

Rounding

Carry intermediate values to at least one more significant figure than the answer requires and round only at the end. Rounding at each step accumulates error and can move a result past the nearest answer choice. Where answer choices are close together, that accumulated error is exactly what separates the correct choice from the distractor placed next to it.

Loading diagram... Systematic approach to a calculation item