Study guide

2.6 Cleaning, Disinfecting, Sporicidal Agents & Sterile 70% IPA

BCSCP Board Certified Sterile Compounding Pharmacist Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Exam Overview, USP Standards & CSP Categories

1.1 BCSCP Exam Format, Eligibility, Scoring & 2024 Content Outline 1.2 USP <797> Scope, Core Philosophy & Regulatory Framework 1.3 USP <797> Categories 1, 2, and 3 CSP Classification 1.4 Immediate-Use CSPs: The 4-Hour Rule and Its Conditions

2 Chapter 2: Facilities, Engineering Controls & Cleaning

2.1 Cleanroom Architecture & ISO Classifications 2.2 Primary Engineering Controls (PECs) & Laminar Airflow Dynamics 2.3 Segregated Compounding Areas (SCAs) & Containment SCAs (C-SCAs) 2.4 HVAC Engineering Controls, Pressure Differentials & Air Exchange 2.5 Equipment & Materials in Classified Areas Under Dynamic Conditions 2.6 Cleaning, Disinfecting, Sporicidal Agents & Sterile 70% IPA 2.7 Contingency Planning: Power, HVAC, Supply and Staffing Failures

3 Chapter 3: Environmental Monitoring & Facility Certification

3.1 Viable Airborne Microbial Monitoring 3.2 Total Airborne Non-Viable Particle Counting & Cleanroom Certification Standards 3.3 Surface Microbial Sampling: Contact Plates, Swabs, Incubation Protocols & Action Levels 3.4 Environmental Sampling Excursions, Trend Analysis, and Remediation Protocols

4 Chapter 4: Hand Hygiene, Garbing & Aseptic Technique

4.1 Hand Hygiene & Cleansing Protocols 4.2 Step-by-Step Garbing Sequence & Ante-Room Logistics 4.3 Direct Compounding Area (DCA) Aseptic Technique & First Air Integrity

5 Chapter 5: Beyond-Use Dating, Storage & Container Rules

5.1 Category 1 Beyond-Use Dating & Storage Limitations 5.2 Category 2 Beyond-Use Dating: Sterile vs. Nonsterile Starting Components 5.3 Category 3 Beyond-Use Dating: Requirements for Extended Dating (60/90/120 Days) 5.4 Container Types, Puncture Limits & Multi-Dose Container Rules

6 Chapter 6: Sterilization, Release Testing & Hazardous Drug Compounding

6.1 Terminal Sterilization vs. Sterilizing Filtration 6.2 Release Testing: Sterility (USP <71>), Endotoxin (USP <85>) & Particulates (USP <788>) 6.3 Container Closure Integrity Testing (CCIT) & Visual Inspection 6.4 USP <800> Hazardous Drug Compounding & Closed System Drug-Transfer Devices (CSTDs)

7 Chapter 7: Materials, Equipment & Compounding Workflow

7.1 Compounding Equipment & Technology: ACDs, Balances, Pumps & IV Workflow Systems 7.2 Compounding Supplies, Containers & Closures 7.3 Component Receipt, Storage & Material Transfer 7.4 Calibration, Verification, Validation & Maintenance of Equipment 7.5 Compounding Workflow: SOPs, Workflow Software, Production Queues & Labeling 7.6 Handling, Storing, Packaging, Transporting & Disposing of Finished CSPs

8 Chapter 8: Calculations, Osmolarity & Physicochemical Compatibility

8.1 Sterile Compounding Calculations: Millimoles, Milliequivalents, Osmolarity & Tonicity Adjustments 8.2 Physical and Chemical Incompatibilities: pH Effects, Salt Formations & Precipitation Mechanisms 8.3 Complex Admixture Compatibility: Calcium-Phosphate Solubility Curves & Parenteral Nutrition Dynamics

9 Chapter 9: Therapeutics, Administration & Patient Monitoring

9.1 Patient-Specific Parameters: Verifying CSP Orders 9.2 Special Administration Routes: Epidural, Intrathecal, Ophthalmic & Intravesical Sterile Preparations 9.3 Medication Delivery Devices, Home Infusion & Patient Education 9.4 High-Alert Sterile Medications, Pediatric/Neonatal Considerations & Extravasation Management 9.5 Therapeutic Drug Monitoring, Catheter-Related Bloodstream Infection (CRBSI) Prevention & Clinical Vigilance 9.6 Medication Adherence in Home and Outpatient Sterile Therapy 9.7 Interprofessional Care Coordination for Sterile Preparations

10 Chapter 10: Quality Management, Records & Personnel Competency

10.1 Master Formulation Records (MFR) vs. Compounding Records (CR) Requirements & Workflow 10.2 Personnel Training, Core Competency & Written Testing Requirements 10.3 Gloved Fingertip and Thumb Sampling (GFT) Testing Cadence, Pass/Fail Thresholds & Action Plans 10.4 Media-Fill Testing Protocols: Simulation Design, Incubation Parameters & Failure Investigations 10.5 Standard Operating Procedures & Document Control 10.6 Quality Assurance & Quality Control Programs 10.7 Inspection Methods, Self-Audits & Continuous Readiness 10.8 Literature Evaluation: Research Methods, Statistics & Stability Evidence

11 Chapter 11: Regulatory Oversight, Accreditation & Drug Supply Chain

11.1 Drug Quality and Security Act (DQSA) & FDA Section 503A Traditional Pharmacies vs. Section 503B Outsourcing Facilities 11.2 State Boards of Pharmacy, FDA Guidance & Inter-Agency Regulatory Jurisdictions 11.3 Drug Supply Chain Security Act (DSCSA), Component Qualification & Certificate of Analysis (CoA) Verification 11.4 CMS, The Joint Commission, CDC, ASPEN & ASHP: Standards Beyond USP and FDA

12 Chapter 12: Safety Management, Investigations, Recalls & Waste

12.1 Root Cause Analysis (RCA), CAPA Framework & Out-of-Specification (OOS) Investigations 12.2 Adverse Drug Event Reporting, FDA MedWatch Form 3500 & Product Recall Protocols 12.3 Occupational Safety, Hazardous Waste Disposal (RCRA / EPA) & Spill Clean-up Management

2.6 Cleaning, Disinfecting, Sporicidal Agents & Sterile 70% IPA

Key Takeaways Explain This Topic AI

USP <797> separates cleaning (removing soil), disinfecting (killing vegetative microbes) and applying a sporicidal (killing spores). An EPA-registered one-step disinfectant cleaner can combine the first two, but sterile 70% IPA is not a one-step cleaner.

The PEC interior and the equipment inside it, pass-throughs, work surfaces outside the PEC and floors are cleaned and disinfected daily on compounding days. Walls, doors, ceilings, shelving and equipment outside the PEC are done monthly.

A sporicidal disinfectant is applied at least monthly for Category 1 and 2 compounding, and at least weekly for Category 3.

Everything used for cleaning, disinfecting or sporicidal treatment inside the PEC must be sterile, concentrates are diluted with sterile water, and cleaning supplies are low-lint.

Sterile 70% IPA goes on the PEC work surface immediately before compounding and at least every 30 minutes during work. If one process runs longer than 30 minutes, it is not interrupted, and the surface is disinfected right after it ends.

Last updated: September 2026

2.6 Cleaning, Disinfecting, Sporicidal Agents & Sterile 70% IPA

Environmental monitoring can only show what cleaning has already achieved. USP <797> Section 7 is one of the most detailed parts of the chapter, and exam items tend to test exact frequencies and the difference between the kinds of agents.

Four different jobs

Term What it does Example

Cleaning Removes organic and inorganic residue, usually with a detergent Germicidal detergent, sterile water wipe

Disinfecting Destroys fungi, viruses and vegetative bacteria on surfaces EPA-registered disinfectant (quaternary ammonium, phenolic, peroxide)

Sporicidal disinfectant Destroys bacterial and fungal spores, and is expected to kill all vegetative organisms Hydrogen peroxide/peracetic acid, sodium hypochlorite

Sterile 70% IPA A sanitizing agent that reduces microbial numbers and leaves no residue Wiping gloves, critical sites and the PEC work surface

Surfaces must be cleaned before they are disinfected , unless an EPA-registered one-step disinfectant cleaner is used. Such a product is registered to clean and disinfect in the presence of light to moderate soil. USP's FAQ stresses that sterile 70% IPA is not a one-step disinfectant cleaner . If a sporicidal product is also registered as a one-step disinfectant cleaner, it can do all three jobs at once.

Table 10 minimum frequencies (classified areas and SCA perimeter)

Site Cleaning Disinfecting Sporicidal

PEC and the equipment inside it Daily on compounding days, and when contamination is known or suspected Daily on compounding days Monthly

  • Removable work tray Work surface daily; all sides and the area underneath monthly Same Monthly
  • Pass-through chambers Daily on compounding days Daily Monthly
  • Work surfaces outside the PEC Daily on compounding days Daily Monthly
  • Floors Daily on compounding days Daily Monthly
  • Walls, doors and door frames Monthly Monthly Monthly
  • Ceilings Monthly Monthly Monthly
  • Storage shelving and bins Monthly Monthly Monthly
  • Equipment outside the PEC Monthly Monthly Monthly

Category 3: a sporicidal disinfectant is applied at least weekly . SCA ceilings are an exception: USP's FAQ says the Table 10 frequencies cover every SCA surface except the ceiling, which is done when visibly soiled or when contamination is known or suspected. Sinks are cleaned and disinfected each day of use, with a sporicidal at least monthly.

Sterile 70% IPA inside the PEC

Apply it after cleaning and disinfecting, or after a one-step or sporicidal product, to remove any residue.

Apply it immediately before compounding starts.

During compounding, apply it to the horizontal work surface, including any removable tray, at least every 30 minutes . If a single compounding process takes more than 30 minutes , do not interrupt it; disinfect the work surface immediately after it ends.

Always let the IPA dry before starting work.

Agents

Choose agents based on antimicrobial activity, inactivation by organic matter, residue, shelf life, preparation needs and suitability for the surface.

Every agent must be left on the surface for at least the manufacturer's minimum contact time . USP's FAQ notes that one product may need 1 minute to kill bacteria but 3 minutes to kill spores.

In the U.S., disinfectants must be EPA-registered .

Inside the PEC, all cleaning, disinfecting and sporicidal agents must be sterile , and concentrates must be diluted with sterile water . In classified areas outside the PEC, sterile agents should be used.

Once opened, sterile agents and supplies (such as a closed container of sterile wipers, or sterile 70% IPA) may be used only for as long as the manufacturer or the facility's SOPs allow.

Supplies and tools

Wipers, sponges, pads and mop heads must be low-lint ; tool handles and holders are the only exception. USP recommends disposable supplies, and disposable supplies are thrown away after each cleaning activity.

Reusable tools are made of cleanable material (no wood or other porous material). They are dedicated to the classified areas or SCA , are cleaned and disinfected before and after each use , and leave the area only for disposal.

Inside the PEC, cleaning supplies must be sterile, apart from handles and holders, which are cleaned and disinfected before use.

Dispose of used supplies in a way that minimizes dispersal, with minimal agitation and away from work surfaces.

Procedure principles

Only trained, properly garbed personnel clean, using facility-approved agents and written SOPs. Any change in agents or methods requires retraining.

Work from clean to dirty . The same floor mop may be used in the buffer room and then the anteroom, but only in that order .

Inside the PEC, work from the cleanest area toward the dirtiest, in overlapping strokes, and keep liquid off the HEPA filter face.

Document every cleaning, disinfecting and sporicidal application as the SOPs require.

Loading diagram...

Hazardous drug areas (USP <800>)

In HD areas, cleaning also has to protect workers. USP <800> adds deactivation (for example, an oxidizer such as sodium hypochlorite) and decontamination (removing the residue) before cleaning, and disinfection is still required in sterile areas. Agents are applied with wetted wipes rather than spray bottles, to avoid spreading HD residue. The C-PEC is decontaminated at least daily when used, between different HDs, after any spill, and before and after certification. The area under its work tray is treated at least monthly (see 6.4).