Study guide

Environmental Safety, OSHA Regulations & Infection Control

BOC Certified Mastectomy Fitter CMF

Track your progress as you read

Finished sections get a check mark.

1 Facilities Management, Safety & Regulatory Compliance

DMEPOS Supplier Standards, Quality Standards & BOC Facility Accreditation Fitting Room Design, Measuring Instruments & Inventory Controls Environmental Safety, OSHA Regulations & Infection Control Facility Policies, Record Retention & HIPAA Privacy/Security Compliance

2 Professional Practice, Scope of Practice & Ethics

Upholding Patient Confidentiality & Dignity in Clinical Encounters BOC Certification Eligibility, CEU Requirements & Recertification Policy Performance Improvement Systems & Inter-Professional Education BOC CMF Scope of Practice & BOC Code of Ethics Compliance

3 Breast Anatomy, Oncology, Surgical Procedures & Reconstruction

Breast, Chest Wall, Musculoskeletal & Lymphatic System Anatomy Breast Pathology, Cancer Types, Staging & Adjuvant Therapies Breast Conserving Surgery & Mastectomy Classifications Breast Reconstruction Modalities, Tissue Expanders & Going Flat

4 Patient Intake, Physical Assessment & Prescription Verification

Patient Relationship, Clinical Interview & Financial Counseling Evaluating Skin Condition, Healing Readiness, ROM, Strength & Dexterity Assessing Post-Surgical Edema, Lymphedema Risk & Precautions Prescription Assessment, Standard Written Orders & Physician Verification

5 Patient Communication, Psychosocial Care & Care Coordination

Explaining Device Objectives, Procedures & Product Options Psychosocial Impact, Grief, Body Image & Family Dynamics Trauma-Informed Fitting, Special Populations & Patient Autonomy Inter-Professional Communication, Clinical Progress Notes & Referrals

6 Anthropometric Landmarks, Measurement & Post-Surgical Garments

Anatomical Landmarks & Patient Positioning for Measurement Unilateral, Bilateral & Post-Reconstruction Measurement Techniques Post-Surgical Camisoles, Drain Management & Transitional Forms Lymphedema Sleeves & Gradient Compression Garment Selection

7 External Breast Prostheses & Post-Mastectomy Bra Selection

Silicone Weighted vs. Lightweight, Foam & Leisure Prostheses Prosthesis Shapes, Profiles, Partial Shapers & Attachable Designs Custom-Fabricated Breast Prostheses (3D Scanning) & Nipple Prostheses Post-Mastectomy Bra Engineering, Pocket Construction & Specialty Garments

8 Product Alignment, Delivery, Medicare Billing & Follow-Up

Fitting Alignment, Biomechanical Balance & Bra/Form Troubleshooting Donning/Doffing Instruction, Return Demonstration & Product Care Proof of Delivery, HCPCS L-Codes, Modifiers, ABNs & WHCRA Coverage Follow-Up Evaluation, Chart Updates & Replacement Schedules

Environmental Safety, OSHA Regulations & Infection Control

Key Takeaways Explain This Topic AI

Perform hand hygiene with 60%–95% alcohol-based hand rub for routine care when hands are not visibly soiled, and wash with soap and water for at least 20 seconds whenever hands are visibly soiled or exposed to body fluids or spore-forming pathogens.

Never place reusable try-on silicone prostheses or tight bands over open incisions, active surgical drains, or weeping radiation dermatitis; defer definitive silicone fitting until the wound is fully healed and fit a soft post-surgical camisole (L8015) if appropriate.

Clean reusable trial silicone forms with warm water and mild non-lanolin soap followed by a disinfectant the manufacturer approves for its polyurethane film, strictly observing the EPA-registered disinfectant's wet contact (dwell) time.

Comply with OSHA 29 CFR § 1910.1030 (annual Exposure Control Plan review, free Hepatitis B vaccine offer within 10 working days) and 29 CFR § 1910.1200 (accessible 16-section Safety Data Sheets and GHS labels for all disinfectants and adhesives).

Last updated: October 2026

CDC Standard & Contact Precautions in the Mastectomy Fitting Suite

Many breast cancer patients undergoing chemotherapy, targeted immunotherapy, or radiation therapy are significantly immunocompromised (neutropenic) and have fragile or disrupted skin barriers along the chest wall and axilla. At the same time, post-operative patients may present with seroma drainage, dehisced suture lines, moist desquamation from radiation dermatitis, or colonized wounds (such as Staphylococcus aureus / MRSA). Consequently, the mastectomy facility must enforce CDC Standard Precautions for every patient encounter and Transmission-Based Contact Precautions whenever non-intact skin or wound exudate is present.

Hand Hygiene Protocols :

Alcohol-Based Hand Rub (ABHR) : The preferred method for routine hand antisepsis when hands are not visibly soiled . Apply a rub containing 60%–95% ethanol or isopropanol and rub all surfaces of hands and fingers until completely dry (minimum 20 seconds ) before and after every patient contact.

Soap and Water Handwashing : Mandatory whenever hands are visibly soiled , after potential exposure to blood or body fluids (such as seroma fluid or wound exudate), after using the restroom, and after caring for patients with known or suspected spore-forming pathogens (such as Clostridioides difficile ). Wash with plain or antimicrobial soap and warm water with vigorous friction for at least 20 seconds , dry with a disposable paper towel, and use the paper towel to turn off the faucet.

Personal Protective Equipment (PPE) & Non-Intact Skin :

Gloves : Wear clean, non-sterile nitrile (latex-free) examination gloves whenever palpating or measuring a chest wall with unhealed incisions, scabs, surgical drains (e.g., Jackson-Pratt or Blake drains), radiation moist desquamation, open lymphedema skin fissures, or active dermatitis. Using latex-free gloves and products is standard practice to avoid triggering Type I IgE-mediated latex anaphylaxis or Type IV allergic contact dermatitis.

Gowns & Barrier Protection : Wear a disposable fluid-resistant gown if clothing may contact draining wounds or uncontained body fluids.

Wound Readiness & Deferral of Silicone Fitting :

A weighted silicone breast prosthesis ( L8030 ) and underwire or tight band bra must never be fitted directly over open surgical incisions, active surgical drains, unhealed skin grafts, or weeping radiation burns. Until the incision is fully closed, sutures/drains are removed, and the physician clears the chest wall for mechanical load, the fitter should fit only a soft, breathable post-surgical camisole with lightweight fiberfill puff forms (L8015) or sterile barrier dressing, and communicate directly with the referring physician if signs of surgical site infection (erythema, warmth, purulent exudate, fever, or sudden seroma swelling) are observed.

Warning

Critical Clinical Rule: Never Place Reusable Try-On Sizers Over Open or Weeping Skin: Under the Spaulding Classification for medical device reprocessing, reusable try-on silicone prostheses and bra sizers are designed as non-critical items that contact intact skin only . They must never be placed directly against open incisions, weeping radiation dermatitis, or draining wounds. Even on intact skin, facilities should use a clean single-use camisole, disposable hygienic liner, or freshly laundered pocketed try-on bra as a barrier between the patient's skin and the trial prosthesis.

Cleaning, Disinfection & Sanitization of Try-On Prostheses, Garments & Tools

BOC Facility Accreditation and CMS Quality Standards require written protocols for cleaning and disinfecting every reusable item that contacts a patient during a fitting session.

Item Category Post-Fitting Reprocessing Protocol Products & Practices to Strictly Avoid

Silicone Breast Forms & Trial Sizers Wash thoroughly with warm water and mild, unscented, non-lanolin liquid soap; rinse and dry with a soft lint-free towel; disinfect only with a product the prosthesis manufacturer approves for its polyurethane film (for example, an approved EPA-registered hospital-grade disinfectant wipe ), observing the exact wet contact / dwell time Never autoclave, boil, soak in bleach (sodium hypochlorite), or scrub with abrasive pads, acetone, or oil/lanolin-based cleansers—these destroy or cloud the polyurethane outer membrane

Reusable Measuring Tapes & Calipers Wipe the entire length of the fiberglass/coated tape and caliper tips with an EPA-registered intermediate- or low-level hospital disinfectant wipe , keeping the surface visibly wet for the manufacturer's stated dwell time (typically 1–3 minutes), then air-dry before returning to clean storage Do not return a used tape directly to a drawer without disinfecting; discard disposable paper tapes after a single patient

Try-On Mastectomy Bras & Camisoles Inspect after each try-on; launder soiled or perspiration-dampened try-on garments in hot water with hypoallergenic detergent and machine dry, or require patients to wear a thin disposable hygiene liner under trial garments Never place a visibly soiled, deodorant-stained, or exudate-contaminated garment back onto the fitting rack

Fitting Room Surfaces (Chair, Bench, Counter, Door Handles) Wipe down arm rests, bench surfaces, counters, and mirror frames between patients using EPA-registered hospital disinfectant wipes; replace disposable barrier paper on work surfaces Avoid household glass cleaners on high-touch clinical contact surfaces, as they lack bactericidal/virucidal efficacy

Contaminated Returns & Biohazard Handling : If a patient brings a previously dispensed prosthesis or garment back to the facility for warranty evaluation or adjustment, the fitter must don nitrile gloves, inspect and clean/disinfect the item in a designated utility area before placing it on any clean work counter, and place any item contaminated with blood or infectious exudate into a sealed biohazard bag.

Note

Understanding Disinfectant Wet Contact (Dwell) Time: When BOC surveyors inspect a facility's infection control practices, one of the most common questions posed to staff is: "What is the wet contact time for your disinfectant wipes?" Every EPA-registered disinfectant specifies a mandatory dwell time (e.g., 1, 2, or 3 minutes) on the canister label during which the treated surface must remain visibly wet to kill target pathogens (such as Staphylococcus aureus , Pseudomonas , HBV, HIV, and SARS-CoV-2). Wiping a surface and immediately drying it with a paper towel invalidates the disinfection process.

OSHA Workplace Safety: Bloodborne Pathogens, HazCom & Emergency Protocols

Mastectomy fitting facilities with employees are governed by Occupational Safety and Health Administration ( OSHA ) federal and state workplace safety standards:

OSHA Bloodborne Pathogens Standard (29 CFR § 1910.1030) :

Exposure Control Plan (ECP) : Facilities where employees have reasonably anticipated occupational exposure to blood or Other Potentially Infectious Materials (OPIM) (including unfixed tissue or wound drainage contaminated with blood) must maintain a written Exposure Control Plan that is reviewed and updated at least annually .

Hepatitis B Vaccination : Employers must offer the Hepatitis B vaccination series free of charge to all employees with occupational exposure within 10 working days of initial assignment (employees who decline must sign the mandatory OSHA declination statement).

Post-Exposure Evaluation : Following any mucous membrane, non-intact skin, or percutaneous exposure incident, the employer must provide immediate confidential medical evaluation, source testing (as permitted by law), and post-exposure prophylaxis at no cost to the employee.

Regulated Medical Waste : Gauze or dressings saturated or caked with liquid/semi-liquid blood or OPIM must be discarded in labeled, leak-proof red biohazard bags ( 29 CFR § 1910.1030(d)(4)(iii) ), whereas minor bandages with minimal dried spotting may go into lined general trash in accordance with state/local regulations.

OSHA Hazard Communication Standard (29 CFR § 1910.1200 — "Right-to-Know" / GHS) :

Facilities must maintain an up-to-date inventory of all hazardous chemicals on site (surface disinfectants, skin adhesives, adhesive removers, silicone cleaners) and ensure a standardized 16-section Safety Data Sheet (SDS) is readily accessible to all employees during every work shift (via physical binder or uninterrupted electronic access).

All secondary spray bottles or containers must carry Globally Harmonized System (GHS) compliant labels showing the product identifier, signal word, hazard statements, and pictograms.

Fire Safety & Fall Prevention :

Fire Extinguishers & Exits : Illuminated exit signs and unobstructed egress pathways must be maintained at all times. Portable fire extinguishers must undergo monthly visual inspections and annual professional maintenance tags . Staff are trained on the RACE (Rescue, Alarm, Contain, Extinguish/Evacuate) and PASS (Pull, Aim, Squeeze, Sweep) protocols.

Fall Prevention : Floor mats must have beveled, non-curling edges; electrical cords from 3D scanners or lamps must be secured out of walkways; spills must be cleaned immediately with wet-floor signage; and employees must use only OSHA-compliant step stools (never chairs) when retrieving high stockroom boxes.

  • Tip
  • RACE and PASS Fire Response Mnemonics

R-A-C-E (Facility Fire Response Sequence): R escue/remove patients in immediate danger → A ctivate the fire alarm / call 911 → C ontain the fire by closing doors → E xtinguish (if small and safe) or E vacuate.

P-A-S-S (Fire Extinguisher Operation): P ull the pin → A im low at the base of the fire → S queeze the lever → S weep from side to side.