Study guide

Facility Policies, Record Retention & HIPAA Privacy/Security Compliance

BOC Certified Mastectomy Fitter CMF

Track your progress as you read

Finished sections get a check mark.

1 Facilities Management, Safety & Regulatory Compliance

DMEPOS Supplier Standards, Quality Standards & BOC Facility Accreditation Fitting Room Design, Measuring Instruments & Inventory Controls Environmental Safety, OSHA Regulations & Infection Control Facility Policies, Record Retention & HIPAA Privacy/Security Compliance

2 Professional Practice, Scope of Practice & Ethics

Upholding Patient Confidentiality & Dignity in Clinical Encounters BOC Certification Eligibility, CEU Requirements & Recertification Policy Performance Improvement Systems & Inter-Professional Education BOC CMF Scope of Practice & BOC Code of Ethics Compliance

3 Breast Anatomy, Oncology, Surgical Procedures & Reconstruction

Breast, Chest Wall, Musculoskeletal & Lymphatic System Anatomy Breast Pathology, Cancer Types, Staging & Adjuvant Therapies Breast Conserving Surgery & Mastectomy Classifications Breast Reconstruction Modalities, Tissue Expanders & Going Flat

4 Patient Intake, Physical Assessment & Prescription Verification

Patient Relationship, Clinical Interview & Financial Counseling Evaluating Skin Condition, Healing Readiness, ROM, Strength & Dexterity Assessing Post-Surgical Edema, Lymphedema Risk & Precautions Prescription Assessment, Standard Written Orders & Physician Verification

5 Patient Communication, Psychosocial Care & Care Coordination

Explaining Device Objectives, Procedures & Product Options Psychosocial Impact, Grief, Body Image & Family Dynamics Trauma-Informed Fitting, Special Populations & Patient Autonomy Inter-Professional Communication, Clinical Progress Notes & Referrals

6 Anthropometric Landmarks, Measurement & Post-Surgical Garments

Anatomical Landmarks & Patient Positioning for Measurement Unilateral, Bilateral & Post-Reconstruction Measurement Techniques Post-Surgical Camisoles, Drain Management & Transitional Forms Lymphedema Sleeves & Gradient Compression Garment Selection

7 External Breast Prostheses & Post-Mastectomy Bra Selection

Silicone Weighted vs. Lightweight, Foam & Leisure Prostheses Prosthesis Shapes, Profiles, Partial Shapers & Attachable Designs Custom-Fabricated Breast Prostheses (3D Scanning) & Nipple Prostheses Post-Mastectomy Bra Engineering, Pocket Construction & Specialty Garments

8 Product Alignment, Delivery, Medicare Billing & Follow-Up

Fitting Alignment, Biomechanical Balance & Bra/Form Troubleshooting Donning/Doffing Instruction, Return Demonstration & Product Care Proof of Delivery, HCPCS L-Codes, Modifiers, ABNs & WHCRA Coverage Follow-Up Evaluation, Chart Updates & Replacement Schedules

Facility Policies, Record Retention & HIPAA Privacy/Security Compliance

Key Takeaways Explain This Topic AI

CMS requires DMEPOS suppliers to retain medical records, Standard Written Orders, fitting notes, and Proof of Delivery documentation for 7 years from the date of service, whereas HIPAA requires privacy/compliance records to be kept for at least 6 years.

Under the HIPAA Privacy Rule, PHI may be used or disclosed without separate patient authorization for Treatment, Payment, and Health Care Operations (TPO), while patients have the right to obtain copies of their records within 30 calendar days of request.

Chest wall photographs and 3D scans for custom breast prostheses (L8035) must be captured only on encrypted facility devices with documented consent, and Business Associate Agreements (BAAs) must be signed with any vendor handling PHI.

Under the HITECH Breach Notification Rule, breaches of unsecured PHI require notifying affected individuals within 60 calendar days; breaches affecting 500 or more individuals also require notifying the HHS Secretary and local media within 60 calendar days, whereas breaches under 500 individuals are reported to HHS within 60 days after the calendar year ends.

Last updated: October 2026

Facility Governance: Policy Manuals, Credentialing & Continuous Quality Improvement (CQI)

A BOC-accredited mastectomy facility must maintain a comprehensive, site-specific Policy and Procedure (P&P) Manual that governs daily administration, clinical fitting protocols, emergency preparedness, human resources, and billing compliance. Surveyors verify that the P&P Manual is not merely a static binder on a shelf, but a living operational system:

Annual Policy Review & Version Control : Management must review the P&P Manual at least annually , documenting the review date, revision history, and leadership signature. Staff must receive documented training whenever policies are updated.

Human Resources, Credentialing & OIG Exclusion Screening :

Personnel files must contain current job descriptions, competency evaluations (observed fitting assessments for clinical staff), annual OSHA/HIPAA training logs, and active credentials ( BOC CMF certification and any required state orthotic/prosthetic/mastectomy fitter license).

OIG LEIE & SAM.gov Screening : Because federal healthcare programs prohibit payment for items or services furnished by—or at the medical direction of—an excluded individual or entity, facilities should screen all prospective employees, contractors, and vendors against the HHS Office of Inspector General (OIG) List of Excluded Individuals and Entities (LEIE) and the System for Award Management (SAM.gov) before hiring and then on a regular schedule (many compliance programs check monthly).

Continuous Quality Improvement (CQI) Program :

The CMS DMEPOS Quality Standards require a performance management program that measures outcomes and beneficiary satisfaction. Many accredited suppliers review the data quarterly and summarize it annually. Core mastectomy CQI metrics include patient satisfaction survey results , beneficiary complaint logs , remake/exchange or warranty return rates , adverse event/incident reports , and internal chart audit pass rates (verifying that Standard Written Orders, clinical fitting notes, and Proof of Delivery records are complete prior to claim submission).

Note

CMS 7-Year vs. HIPAA 6-Year Record Retention Rules Mastectomy facilities must satisfy two distinct federal retention clocks (in addition to any stricter state statute of limitations):

CMS DMEPOS Medical & Claim Record Retention (42 CFR § 424.57(c)(28) / § 424.516(f)) : 7 years from the date of service . Applies to physician orders (SWOs), clinical assessment and fitting notes, medical necessity documentation, proof of delivery (POD) receipts, and lot/serial number logs.

HIPAA Compliance Documentation Retention (45 CFR § 164.530(j)) : 6 years from the date of creation or the date when it last was in effect, whichever is later . Applies to written privacy/security policies, signed Notice of Privacy Practices (NPP) acknowledgments, HIPAA authorizations, Business Associate Agreements (BAAs), and breach investigation logs.

Best Practice : Retain both clinical and HIPAA records for at least 7 years (or until a minor reaches the age of majority plus the state statute of limitations, if longer).

HIPAA Privacy Rule (45 CFR Part 164 Subpart E) & Patient Rights

As a healthcare provider that transmits health information electronically in connection with standard HIPAA transactions (such as X12 837P electronic claims), a mastectomy supplier is a Covered Entity under the Health Insurance Portability and Accountability Act (HIPAA) .

Protected Health Information (PHI) & the 18 Identifiers : Individually identifiable health information held or transmitted in any form (oral, paper, or electronic ePHI ) is protected. De-identification requires removing all 18 HIPAA identifiers (including name, geographic subdivisions smaller than a state, dates directly related to an individual such as birth/admission/service dates, phone numbers, e-mail addresses, SSN, medical record numbers, health plan beneficiary numbers/MBIs, device serial numbers, and full-face photographs or comparable biometric images ).

Permitted Uses & Disclosures for TPO : Covered entities may use and disclose PHI without a separate signed patient authorization for Treatment (coordinating care or clarifying an order with the referring oncologist/surgeon), Payment (submitting claims and medical necessity records to Medicare or private insurers), and Health Care Operations (quality assessment, accreditation surveys, and internal audits).

Minimum Necessary Standard : When using or disclosing PHI for Payment or Health Care Operations, staff must make reasonable efforts to limit PHI to the minimum necessary to accomplish the intended purpose. ( Note : The Minimum Necessary Standard does not apply to disclosures made to a healthcare provider for Treatment , disclosures to the patient directly, or uses pursuant to a valid patient-signed authorization.)

Notice of Privacy Practices (NPP) & Patient Access Timeline :

The facility must provide its Notice of Privacy Practices (NPP) to every patient no later than the date of first service delivery , make a good-faith effort to obtain a written acknowledgment of receipt (or document why acknowledgment could not be obtained), and post the NPP prominently in the facility and on its website.

Under the HIPAA Right of Access (45 CFR § 164.524) , when a patient requests to inspect or obtain a copy of their medical and fitting records, the facility must provide access within 30 calendar days of receipt of the request (with at most one 30-calendar-day extension permitted if the facility provides a written statement of the reasons for delay and the expected completion date within the initial 30 days).

Loading diagram... HITECH Act Breach Notification Decision & Reporting Timeline (45 CFR §§ 164.400–414)

HIPAA Security Safeguards, Business Associate Agreements & HITECH Breach Rules

To protect electronic PHI ( ePHI ) stored in EHR/billing software, 3D custom breast scanning tablets, and cloud backups, the HIPAA Security Rule (45 CFR Part 164 Subpart C) requires three interlocking safeguard categories:

Safeguard Category Core Implementation Requirements in a Mastectomy Facility

Administrative Safeguards Designated Privacy/Security Officer; enterprise-wide Security Risk Analysis (SRA) ; workforce security training; role-based access authorization; sanction policy for employee violations; contingency/data backup plan

Physical Safeguards Locked file cabinets and server closets; computer monitors angled away from waiting room/public sightlines ( privacy screens ); clean-desk policy; secure disposal of paper PHI via cross-cut shredding or locked shred bins (never regular trash)

Technical Safeguards Unique user IDs and complex passwords for every fitter/biller ( no shared logins ); automatic workstation logoff after inactivity; AES-256 encryption of ePHI at rest and TLS encryption in transit; electronic audit logs tracking who viewed or modified patient charts

Clinical Photography & 3D Scanning for Custom Breast Prostheses (L8035) :

When fitting a custom-fabricated silicone prosthesis, fitters frequently capture digital chest wall photographs or 3D optical scans to document surgical chest wall contour and match skin pigment. Even if the patient's face is excluded, chest wall images linked to a patient file or containing distinctive tattoos/scars constitute PHI . The facility must:

Obtain documented informed consent explaining the clinical/manufacturing purpose of the images (and obtain a separate written HIPAA marketing authorization before ever using a photo on social media, brochures, or educational displays).

Capture images only on facility-owned, encrypted devices or HIPAA-compliant clinical applications— never on a fitter's personal unencrypted smartphone camera roll with consumer cloud photo syncing enabled.

Business Associate Agreements (BAAs) :

Before sharing any PHI with an outside vendor that creates, receives, maintains, or transmits PHI on the facility's behalf—such as an electronic billing clearinghouse, cloud EHR vendor, external CPA/auditor, shredding contractor, or custom breast prosthesis manufacturer (L8035 lab) —the facility must execute a written Business Associate Agreement (BAA) obligating the vendor to safeguard PHI and report any security breaches.

HITECH Act Breach Notification Rule (45 CFR §§ 164.400–414) :

If unsecured (unencrypted) PHI is impermissibly accessed, stolen, or disclosed, a breach is presumed unless a documented Four-Factor Risk Assessment (1. nature/extent of PHI involved; 2. unauthorized person who used/received it; 3. whether PHI was actually acquired or viewed; 4. extent to which risk was mitigated) demonstrates a low probability that the PHI was compromised. For reportable breaches:

Affected Individuals : Written notification must be sent without unreasonable delay and no later than 60 calendar days from discovery.

500 or More Individuals : Notify the HHS Secretary contemporaneously (no later than 60 calendar days ) and notify prominent media outlets serving the state/jurisdiction.

Fewer Than 500 Individuals : Maintain an internal breach log and report to the HHS Secretary within 60 calendar days after the end of the calendar year in which the breaches were discovered.

Civil Monetary Penalties : HITECH establishes a four-tier penalty structure ranging from $100 to $50,000+ per violation (adjusted annually for inflation), up to a base statutory cap of $1,500,000 per year for identical violation categories.

  • Note
  • Distinguishing TPO Disclosure vs. Written HIPAA Authorization

No Separate HIPAA Authorization Needed (TPO) : Faxing a patient's clinical fitting notes and chest wall measurements to her referring breast surgeon to request a corrected Standard Written Order, or transmitting those records to the DME MAC during a prepayment medical necessity audit.

Separate Written HIPAA Authorization Required : Posting an anonymized patient testimonial and post-fitting photograph on the boutique's Instagram page, or selling/sharing a patient mailing list with a third-party cosmetic spa.