1 Facilities Management, Safety & Regulatory Compliance

DMEPOS Supplier Standards, Quality Standards & BOC Facility Accreditation Fitting Room Design, Measuring Instruments & Inventory Controls Environmental Safety, OSHA Regulations & Infection Control Facility Policies, Record Retention & HIPAA Privacy/Security Compliance

2 Professional Practice, Scope of Practice & Ethics

Upholding Patient Confidentiality & Dignity in Clinical Encounters BOC Certification Eligibility, CEU Requirements & Recertification Policy Performance Improvement Systems & Inter-Professional Education BOC CMF Scope of Practice & BOC Code of Ethics Compliance

3 Breast Anatomy, Oncology, Surgical Procedures & Reconstruction

Breast, Chest Wall, Musculoskeletal & Lymphatic System Anatomy Breast Pathology, Cancer Types, Staging & Adjuvant Therapies Breast Conserving Surgery & Mastectomy Classifications Breast Reconstruction Modalities, Tissue Expanders & Going Flat

4 Patient Intake, Physical Assessment & Prescription Verification

Patient Relationship, Clinical Interview & Financial Counseling Evaluating Skin Condition, Healing Readiness, ROM, Strength & Dexterity Assessing Post-Surgical Edema, Lymphedema Risk & Precautions Prescription Assessment, Standard Written Orders & Physician Verification

5 Patient Communication, Psychosocial Care & Care Coordination

Explaining Device Objectives, Procedures & Product Options Psychosocial Impact, Grief, Body Image & Family Dynamics Trauma-Informed Fitting, Special Populations & Patient Autonomy Inter-Professional Communication, Clinical Progress Notes & Referrals

6 Anthropometric Landmarks, Measurement & Post-Surgical Garments

Anatomical Landmarks & Patient Positioning for Measurement Unilateral, Bilateral & Post-Reconstruction Measurement Techniques Post-Surgical Camisoles, Drain Management & Transitional Forms Lymphedema Sleeves & Gradient Compression Garment Selection

7 External Breast Prostheses & Post-Mastectomy Bra Selection

Silicone Weighted vs. Lightweight, Foam & Leisure Prostheses Prosthesis Shapes, Profiles, Partial Shapers & Attachable Designs Custom-Fabricated Breast Prostheses (3D Scanning) & Nipple Prostheses Post-Mastectomy Bra Engineering, Pocket Construction & Specialty Garments

8 Product Alignment, Delivery, Medicare Billing & Follow-Up

Fitting Alignment, Biomechanical Balance & Bra/Form Troubleshooting Donning/Doffing Instruction, Return Demonstration & Product Care Proof of Delivery, HCPCS L-Codes, Modifiers, ABNs & WHCRA Coverage Follow-Up Evaluation, Chart Updates & Replacement Schedules

Anatomical Landmarks & Patient Positioning for Measurement

Key Takeaways Explain This Topic AI

The five core thoracic landmarks for mastectomy measurement are the jugular (sternal) notch, mid-sternum, inframammary fold (IMF, typically 6th–7th rib), natural breast apex, and mid-axillary line / posterior mid-spine.

During unilateral measurement, the mid-sternum serves as the anterior zero-point and the posterior spinous process (mid-spine) serves as the posterior terminal point for half-chest under-bust and over-bust readings.

The patient must stand or sit upright with relaxed, level shoulders, arms hanging naturally at the sides, breathing normally, and wearing a well-supporting, non-padded diagnostic bra on the intact breast.

Measuring a ptotic or heavy natural breast bare-chested allows the apex to sag and flatten, placing the measurement plane too low and underestimating true cup projection and prosthesis volume.

Last updated: October 2026

Skeletal and Soft-Tissue Reference Landmarks of the Thorax

Precision in post-mastectomy fitting begins with objective anthropometric measurement anchored to reproducible skeletal and soft-tissue landmarks on the patient's thorax. Pre-surgical bra labels cannot be trusted as baseline measurements because commercial lingerie sizing varies widely across retail brands, patients frequently wore an incorrect band or cup size prior to surgery, and oncologic treatments—including mastectomy, axillary lymph node dissection, chemotherapy-induced weight shifts, and radiation fibrosis—fundamentally remodel the geometry of the chest wall.

Under the BOC Certified Mastectomy Fitter clinical standards (Domain 3.A.1.a ), the fitter palpates and visually identifies five primary anatomical landmarks before applying a measuring tape:

Jugular / Suprasternal Notch (Sternal Notch): The palpable concave depression at the superior border of the manubrium sterni, situated directly between the medial sternal heads of the left and right clavicles at the horizontal plane of the T2–T3 thoracic intervertebral disc. Because the sternal notch is a fixed skeletal landmark unaffected by soft-tissue surgical resection, it serves as the superior vertex for measuring the sternal-notch-to-apex distance (or mid-clavicle-to-apex distance ). In a unilateral mastectomy fitting, matching the vertical diagonal distance from the sternal notch to the prosthesis apex against the intact contralateral sternal-notch-to-apex measurement ensures that both breasts rest at the exact same vertical elevation on the chest wall.

Mid-Sternum (Anterior Midline): The vertical longitudinal line bisecting the anterior surface of the sternal body (corpus sterni) from the manubriosternal junction (Angle of Louis at the second costal cartilage) inferiorly to the xiphisternal joint. Clinically, the mid-sternum represents the bony plane where the center gore (bridge) of a therapeutic mastectomy bra must sit flush against the chest wall without floating, twisting, or shifting toward the intact breast. During unilateral measurement, the mid-sternum functions as the anterior zero-point ( 0.0 in. ) for both the half-chest under-bust and half-chest over-bust measurements.

Inframammary Fold (IMF / Inframammary Crease): The curved inferior cutaneous and fascial junction where the lower pole of the natural breast parenchyma meets the anterior thoracic wall, typically overlying the sixth to seventh ribs (6th–7th costal cartilages) . Where Cooper's suspensory ligaments and superficial fascia condense into the deep pectoral fascia, the IMF defines the horizontal transverse plane for the under-bust (band) circumference measurement . On the surgical side—where the natural IMF crease has often been ablated or shifted during skin-flap closure—the fitter projects a horizontal line across from the intact IMF so that the surgical-side bra cup cradle and the lower edge of the breast prosthesis sit level with the remaining natural breast.

Apex (Nipple-Areola Prominence): The point of maximal anterior projection of the remaining natural breast when supported inside a properly fitted, non-padded diagnostic bra. The apex dictates the horizontal path for the over-bust cup measurement as well as the horizontal mid-sternum-to-apex projection distance , verifying that the selected breast prosthesis restores symmetrical forward projection and medial-lateral spacing.

Mid-Axillary Line & Posterior Spinous Process (Mid-Spine): The mid-axillary line drops vertically from the apex of the axillary vault midway between the anterior axillary fold (formed by the lateral border of the pectoralis major) and the posterior axillary fold (formed by the latissimus dorsi and teres major). It defines the lateral boundary of the natural breast footprint and the lateral wire channel of the bra cup. Directly posteriorly ( 180° opposite the mid-sternum), the posterior spinous process (mid-spine) along the mid-thoracic vertebrae ( T4–T8 ) provides the posterior terminal anchor point for half-chest under-bust and over-bust measurements when unilateral breast absence distorts a full 360-degree tape circumference.

Anatomical Landmark Skeletal / Soft-Tissue Location Primary Measurement Function Clinical Consequence of Landmark Error

Jugular / Sternal Notch Superior border of manubrium between medial clavicular heads Superior anchor for diagonal sternal-notch-to-apex vertical leveling Prosthesis sits noticeably higher or lower than the contralateral natural nipple

Mid-Sternum Vertical anterior midline along the body of the sternum Anterior 0.0 in. starting point for half-chest under-bust and over-bust tape paths; center gore tack site Starting lateral to mid-sternum underestimates hemithorax circumference and yields an undersized cup

Inframammary Fold (IMF) Inferior crease at base of breast (6th–7th rib level) Horizontal plane for under-bust (band) measurement and inferior cup cradle leveling Measuring below the IMF onto the upper abdomen or above the IMF onto breast tissue distorts band size

Apex Point of greatest anterior projection of the supported natural breast Horizontal plane for over-bust measurement and anterior-posterior profile selection Measuring above or below the true apex underestimates cup differential and results in cup gaping or spillage

Mid-Axillary Line & Mid-Spine Vertical line from axillary apex ( lateral ) and thoracic spinous processes ( posterior ) Lateral limit of prosthesis footprint ( mid-axillary ) and posterior terminal point ( mid-spine ) for half-chest sizing Prosthesis base too wide impinges into the axilla during arm adduction; off-center posterior anchor skews band/cup math

Note

The Sternal-Notch-to-Apex Symmetry Triangle: Experienced Certified Mastectomy Fitters verify bilateral symmetry by evaluating an imaginary isoceles triangle on the anterior chest wall. The superior apex of the triangle is the jugular (sternal) notch , and the two basal vertices are the left and right breast apices (typically measuring 7.5 in. 7.5\text{ in.} 7.5 in. to 10.5 in. 10.5\text{ in.} 10.5 in. radially from the sternal notch, depending on patient stature and breast maturity). When both diagonal legs from the sternal notch to each apex are equal in length—and the horizontal distances from the mid-sternum to each apex match—the prosthesis and the natural breast achieve visual symmetry both inside the fitting room mirror and under form-fitting street clothing.

Standardized Patient Positioning and Pre-Measurement Setup

Even when anatomical landmarks are palpated accurately, improper patient posture or an unsupported natural breast can introduce errors of 1.5 in. 1.5\text{ in.} 1.5 in. to 3.0 in. 3.0\text{ in.} 3.0 in. into chest circumference readings. Under BOC DCO 3.A.1.b , the fitter establishes a standardized postural and garment baseline before picking up the tape measure:

Erect Upright Stance (or Supported Upright Seated Posture): Whenever safely tolerated, the patient stands upright with her feet shoulder-width apart, knees unlocked, and body weight distributed evenly across both lower extremities. If the patient experiences chemotherapy-induced peripheral neuropathy, orthostatic hypotension, advanced frailty, or balance instability, she should be seated upright near the front edge of a firm, armless fitting chair or stool with her feet flat on the floor and her thoracic spine erect (not slumped against a backrest, which obstructs posterior tape routing and flattens the ribcage).

Neutral, Relaxed Shoulder Girdle and Arm Position: Many post-mastectomy patients unconsciously adopt protective shoulder guarding —elevating, protracting, and internally rotating the shoulder on the surgical side to shield the chest scar or conceal the missing breast. Conversely, other patients pull their scapulae into exaggerated military retraction when asked to stand straight. The fitter should gently cue the patient to roll her shoulders back once and let them drop into a relaxed, level position. The patient briefly abducts her arms to 45 ∘ 45^\circ 4 5 ∘ – 60 ∘ 60^\circ 6 0 ∘ only while the fitter passes the tape around the torso, then lowers both arms to hang naturally at her sides before the measurement is read. Reading the tape while the arms remain elevated contracts the pectoralis major and latissimus dorsi muscles, flaring the upper ribcage and inflating the measurement by 1 in. 1\text{ in.} 1 in. to 2 in. 2\text{ in.} 2 in.

Quiet Tidal Respiration: Circumferential thorax measurements are read at the end of a normal, relaxed tidal breath . If an anxious patient takes a deep inspiratory breath and holds it, ribcage expansion artificially inflates the under-bust measurement; if she forces a maximal exhalation, the band measurement will be constrictively tight.

Mandatory Use of a Well-Fitting, Non-Padded Diagnostic Bra on the Intact Breast: A unilateral mastectomy patient must never be measured for cup size while bare-chested or while wearing a padded push-up bra, a compression sports bra, a minimizer bra, or a worn-out bra with stretched elastic straps. In a bare-chested patient—particularly one with moderate-to-heavy breast tissue or Grade II–III mammary ptosis—gravity pulls the natural breast inferiorly toward the upper abdomen and flattens its anterior projection against the ribcage. Measuring a bare, pendulous breast places the over-bust tape plane too low on the torso and severely underestimates true cup volume. Instead, the patient wears a supportive, unpadded, non-minimizer bra (either her own properly fitting bra or a clinical diagnostic fitting bra from the facility's sanitized try-on inventory) that lifts the intact breast so its apex rests midway between the glenohumeral shoulder joint and the olecranon (elbow) .

Loading diagram... Pre-Measurement Positioning & Landmark Identification Workflow

Navigating Chest Wall Concavities, Rib Prominences, and Axillary Tissue Irregularities

Surgical resection and adjuvant radiation therapy frequently leave the mastectomy side with asymmetric surface topography that requires deliberate tape-handling technique:

Bridging Surgical Concavities and Infraclavicular Hollowing: Patients who have undergone a Halsted radical mastectomy, a modified radical mastectomy with thin skin flaps, or post-mastectomy chest wall irradiation often exhibit deep concavities over the upper chest wall, parasternal border, or pectoral bed. When taking a full 360-degree under-bust check or evaluating chest contour, the fitter uses a flexible, non-stretch fiberglass or plastic-coated measuring tape and bridges the tape smoothly across the plane of the concavity rather than pressing the tape inward into the surgical hollow. Because surgical-side tissue absence invalidates a full-chest over-bust reading, cup sizing is always derived from the intact contralateral hemithorax .

Managing Lateral Axillary "Dog Ears" and Subcutaneous Edema: Redundant lateral skin and adipose folds (commonly termed "dog ears" ) frequently persist at the lateral termination of the mastectomy scar near the anterior or mid-axillary line. If the fitter pulls the tape tightly across a lateral dog ear or post-operative axillary fullness, the tape indents the soft tissue and underestimates the true circumference required for a non-binding bra wing. Conversely, allowing the tape to catch underneath the fold skews the horizontal plane. The fitter must apply skin-contact tension only —snug enough that the tape does not sag, but light enough that it never indents the skin—while checking in the three-way fitting mirror that the tape remains strictly horizontal (parallel to the floor) around the entire hemithorax.

Documenting Skeletal Asymmetries (Rib Flare, Kyphosis, and Scoliosis): Removal of overlying mammary fat frequently exposes a prominent 6th or 7th costal cartilage ( rib flare ) at the surgical IMF, while age-related thoracic kyphosis (forward spinal curvature and sunken anterior chest) or scoliosis (lateral spinal curvature with rib hump and uneven iliac crests/shoulders) alters how a bra band and prosthesis sit against the ribs. Documenting these bony prominences during landmark palpation alerts the fitter to select a prosthesis with a soft dual-layer silicone gel back or a concave sculpted back that vaults over tender ribs without creating focal pressure points.

Warning

Four Critical Measurement Errors to Avoid on the BOC Exam:

Never measure over bulky street clothing or a padded/minimizer bra: Street garments add extraneous circumference, while padded bras inflate the over-bust reading and minimizer bras flatten the apex.

Never allow the posterior tape to droop toward the waist: If the tape slips inferiorly below the level of the inframammary fold along the back, the geometry switches from a horizontal circle to an oblique ellipse, falsely inflating both band and cup measurements.

Never indent the intact breast apex with the tape: Pulling the tape tight across the nipple prominence compresses soft mammary tissue and reduces the calculated cup differential.