Class 5 (Oxidizing Substances & Organic Peroxides) & Class 6 (Toxic & Infectious Substances)
IATA Dangerous Goods Regulations Air
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: General Philosophy, Applicability & CBTA Framework
Legal Basis & International Regulatory Framework Shipper & Operator Responsibilities in Air Transport Competency-Based Training & Assessment (CBTA) & Certification Categories Dangerous Goods Security & High Consequence Dangerous Goods
2 Chapter 2: Dangerous Goods Limitations
Forbidden Dangerous Goods & Hidden Dangerous Goods Recognition Passenger & Crew Baggage Provisions (Section 2.3 Provisions Table) State Variations & Operator Variations (Sections 2.8 and 2.9) Excepted Quantities (EQ) & Limited Quantities (LQ) Provisions Operators' Own Property (COMAT) & Dangerous Goods in Air Mail
3 Chapter 3: Classification of the 9 Hazard Classes
Class 1 (Explosives) & Class 2 (Gases) Classification Class 3 (Flammable Liquids) & Class 4 (Flammable Solids, Spontaneous Combustibles, Dangerous When Wet) Class 5 (Oxidizing Substances & Organic Peroxides) & Class 6 (Toxic & Infectious Substances) Class 7 (Radioactive Material) Basics, Activity Limits & Radiation Protection Class 8 (Corrosives) & Class 9 (Miscellaneous Dangerous Goods & Environmentally Hazardous) Packing Groups (PG I, II, III) & Precedence of Hazards Matrix
4 Chapter 4: Identification & List of Dangerous Goods
Navigating Section 4.2 (Blue Pages & Table Columns A–N) Proper Shipping Names, UN/ID Numbers & Technical Name Rules Special Provisions (Section 4.4) & Mixture/Solution Rules Lithium Batteries Identification & Classification (UN 3090, 3091, 3480, 3481) Section 4.3 Numerical Cross-Reference & the End-to-End Lookup Workflow
5 Chapter 5: Packing Requirements & UN Specification Packaging
General Packing Requirements, Single vs. Combination Packaging & Ullage Rules Packing Instructions (PI) Selection & Quantity Limitations UN Specification Packaging Codes & Performance Tests (Drop, Stacking, Hydraulic Pressure) Overpacks, Salvage Packaging & Pressure Differential Standards Dry Ice, Consumer Commodity (ID 8000) & Class-Specific Packing Provisions Infectious Substances in Practice: Packing Instruction 620 and Packing Instruction 650
6 Chapter 6: Marking & Labelling Requirements
DGR 7.1 — Package Marking Requirements DGR 7.2 — Hazard Class & Subsidiary Risk Labels (Specifications & Placement Rules) DGR 7.2 — Handling Labels (Cargo Aircraft Only, Orientation Arrows, Magnetized Material, Cryogenic) DGR 7.1 — Lithium Battery, Excepted Quantity & Limited Quantity Marks
7 Chapter 7: Dangerous Goods Documentation
DGR 8.1 — Shipper's Declaration for Dangerous Goods (SDDG): Structure & Completion Rules DGR 8.2 — Air Waybill Handling Information & Non-Dangerous Goods Declarations DGR Section 8 — Electronic Shipper's Declaration (e-DGD) & Documentation Retention
8 Chapter 8: Stowage, Handling & Emergency Procedures
Cargo Acceptance Checks & Acceptance Checklist Verification Loading Limitations, Cargo Aircraft Only (CAO) & ULD Rules Segregation & Incompatibility Rules (Table 9.3.A Segregation Matrix) Notification to Captain (NOTOC) & Pilot-in-Command Information Dangerous Goods Incidents, Reporting & Emergency Response Procedures Class 7 Radioactive Material: Section 10 Packing, Labelling, Documentation & Stowage
Class 5 (Oxidizing Substances & Organic Peroxides) & Class 6 (Toxic & Infectious Substances)
Key Takeaways Explain This Topic AI
Division 5.1 Oxidizers yield oxygen readily to stimulate or enhance the combustion of other materials, categorized into PG I, II, or III based on mean burning times relative to reference standard mixtures.
Division 5.2 Organic Peroxides are divided into Types A through G, where Type A is strictly forbidden for transport, and substances requiring temperature control (SADT <= 50°C) are forbidden in air transport.
Division 6.1 Toxic Substances are classified by acute toxicity thresholds across three routes of exposure: Oral (LD50), Dermal (LD50), and Inhalation (LC50 vapor/dust/mist).
Division 6.2 Infectious Substances are divided into Category A (UN 2814 / UN 2900, life-threatening/fatal pathogens requiring UN specification triple packaging) and Category B (UN 3373, biological substances subject to Packing Instruction 650).
Inhalation toxicity for Division 6.1 liquids uses the ratio of V (saturated vapor concentration) to LC50; V >= 10 * LC50 and LC50 <= 1000 mL/m³ dictates Packing Group I status.
Last updated: August 2026
Class 5 (Oxidizing Substances & Organic Peroxides) & Class 6 (Toxic & Infectious Substances)
Chemicals capable of releasing oxygen to accelerate fires, thermally decomposing violently, or posing lethal biological/toxic hazards present severe risks in aviation. Class 5 and Class 6 govern these active chemical and biological hazards under IATA DGR criteria.
Hazard Class 5: Oxidizing Substances & Organic Peroxides
Class 5 is divided into two distinct divisions based on chemical structure and reaction kinetics:
Division 5.1: Oxidizing Substances — Substances which, while in themselves not necessarily combustible, may, generally by yielding oxygen, cause, or contribute to, the combustion of other material.
Division 5.2: Organic Peroxides — Organic substances which contain the bivalent − O − O − -O-O- − O − O − structure and may be considered derivatives of hydrogen peroxide ( H 2 O 2 H_2O_2 H 2 O 2 ), where one or both hydrogen atoms have been replaced by organic radicals.
Division 5.1: Oxidizing Substances Classification & Packing Groups
Division 5.1 solid and liquid oxidizers are evaluated by measuring the rate of burning when mixed with combustible materials (such as dried cellulose) relative to reference oxidizers ( Potassium Bromate or Perchloric Acid ).
Solid Oxidizers (Mean Burning Time Test)
Packing Group I: Any substance which, in a 4:1 or 1:1 sample-to-cellulose ratio by mass, exhibits a mean burning time less than that of a 3:2 potassium bromate-to-cellulose mixture. Example: Oxidizing solid, n.o.s. (UN 1479) where the entry is assigned PG I.
Packing Group II: Any substance which exhibits a mean burning time equal to or less than that of a 2:3 potassium bromate-to-cellulose mixture, and PG I criteria are not met. Examples: Potassium chlorate (UN 1485), Sodium chlorate (UN 1495). Sodium nitrate (UN 1498) sits one step lower, at PG III.
Packing Group III: Any substance which exhibits a mean burning time equal to or less than that of a 3:7 potassium bromate-to-cellulose mixture, and PG I/II criteria are not met.
Division 5.2: Organic Peroxides (Types A through G)
Organic peroxides are thermally unstable compounds liable to undergo self-accelerating exothermic decomposition. They can ignite combustibly, detonate, deflagrate, or react dangerously with other substances. Organic peroxides are assigned to one of seven types (Types A through G) : ORGANIC PEROXIDE TYPES (A to G)
┌───────────────┬───────────────┬───────────────┬───────────────┬───────────────┬───────────────┬───────────────┐
│ TYPE A │ TYPE B │ TYPE C │ TYPE D │ TYPE E │ TYPE F │ TYPE G │
├───────────────┼───────────────┼───────────────┼───────────────┼───────────────┼───────────────┼───────────────┤
- │ Can detonate │ Can detonate │ Can detonate │ Detonates │ Neither │ Neither │ Thermally │
- │/ deflagrate │/ deflagrate │/ deflagrate │ partially or │ detonates nor │ detonates nor │ stable; │
- │ rapidly as │ slowly, but │ slowly, but │ deflagrates │ deflagrates; │ deflagrates; │ no explosive │
- │ packaged. │ safe in │ cannot │ slowly; low │ low effect │ low/no power; │ power. │
- │ │ packages. │ detonate. │ heat effect. │ when heated. │ packaged ok. │ │
├───────────────┼───────────────┼───────────────┼───────────────┼───────────────┼───────────────┼───────────────┤
- │ FORBIDDEN │ Permitted with│ Permitted on │ Permitted on │ Permitted on │ Permitted on │ Exempt from │
- │ FOR TRANSPORT │ CAO / Max Qty │ Aircraft │ Aircraft │ Aircraft │ Aircraft │ Division 5.2 │
└───────────────┴───────────────┴───────────────┴───────────────┴───────────────┴───────────────┴───────────────┘
Crucial Air Transport Restrictions for Division 5.2
Type A Organic Peroxides are FORBIDDEN FOR TRANSPORT on any aircraft.
Temperature Control Requirement: If an organic peroxide has a Self-Accelerating Decomposition Temperature (SADT) of 50°C (122°F) or less , it requires temperature control during transport. Under IATA DGR provisions, all dangerous goods requiring temperature control are strictly FORBIDDEN FOR AIR TRANSPORT .
Hazard Class 6: Toxic & Infectious Substances
Class 6 is divided into two sub-divisions :
- Division 6.1: Toxic Substances
- Division 6.2: Infectious Substances
- Division 6.1: Toxic Substances Toxicity Criteria
Division 6.1 covers substances liable to cause death or serious injury or to harm human health if swallowed, inhaled, or brought into contact with skin.
Toxicity Thresholds for Packing Group Assignment
Grouping is based on acute animal testing data expressed as L D 50 LD_{50} L D 50 (lethal dose for 50% of test population, in mg/kg body weight) or L C 50 LC_{50} L C 50 (lethal concentration for 50% of test population, in mg/L or mL/m³):
Packing Group Oral Toxicity L D 50 LD_{50} L D 50 (mg/kg) Dermal Toxicity L D 50 LD_{50} L D 50 (mg/kg) Inhalation Toxicity Dusts/Mists L C 50 LC_{50} L C 50 (mg/L)
Packing Group I ≤ 5.0 \le 5.0 ≤ 5.0 ≤ 50.0 \le 50.0 ≤ 50.0 ≤ 0.2 \le 0.2 ≤ 0.2
Packing Group II > 5.0 > 5.0 > 5.0 to ≤ 50.0 \le 50.0 ≤ 50.0 > 50.0 > 50.0 > 50.0 to ≤ 200.0 \le 200.0 ≤ 200.0 > 0.2 > 0.2 > 0.2 to ≤ 2.0 \le 2.0 ≤ 2.0
Packing Group III > 50.0 > 50.0 > 50.0 to ≤ 300.0 \le 300.0 ≤ 300.0 > 200.0 > 200.0 > 200.0 to ≤ 1000.0 \le 1000.0 ≤ 1000.0 > 2.0 > 2.0 > 2.0 to ≤ 4.0 \le 4.0 ≤ 4.0
Inhalation Toxicity of Vapors (Liquid Volatility Ratio)
For liquid substances emitting toxic vapors, Packing Group assignment utilizes both the acute inhalation toxicity ( L C 50 LC_{50} L C 50 ) and the saturated vapor concentration ( V V V ) of the liquid at 20 ∘ C 20^\circ\text{C} 2 0 ∘ C in mL/m 3 \text{mL/m}^3 mL/m 3 :
Packing Group I: V ≥ 10 × L C 50 V \ge 10 \times LC_{50} V ≥ 10 × L C 50 AND L C 50 ≤ 1000 mL/m 3 LC_{50} \le 1000\text{ mL/m}^3 L C 50 ≤ 1000 mL/m 3 .
Packing Group II: V ≥ L C 50 V \ge LC_{50} V ≥ L C 50 AND L C 50 ≤ 3000 mL/m 3 LC_{50} \le 3000\text{ mL/m}^3 L C 50 ≤ 3000 mL/m 3 (and PG I criteria are not met).
Packing Group III: V ≥ 1 5 L C 50 V \ge \frac{1}{5} LC_{50} V ≥ 5 1 L C 50 AND L C 50 ≤ 5000 mL/m 3 LC_{50} \le 5000\text{ mL/m}^3 L C 50 ≤ 5000 mL/m 3 (and PG I/II criteria are not met). INHALATION VAPOR TOXICITY NOMOGRAM
- Vapor Conc (V)
- ▲
- │ PG I Zone (V ≥ 10 × LC50 AND LC50 ≤ 1000 ppm)
- │ ┌──────────────────────┐
- │ │ │
- │ │ PG II Zone │ (V ≥ LC50 AND LC50 ≤ 3000 ppm)
- │ │ ┌───────────────────┴─────────────┐
- │ │ │ │ PG III Zone
- │ │ │ PG III Zone │ (V ≥ 1/5 LC50 AND LC50 ≤ 5000 ppm)
- └───┴──┴─────────────────────────────────┴────────────────────────► LC50 (ppm)
- Division 6.2: Infectious Substances
Division 6.2 covers substances known or reasonably expected to contain pathogens (microorganisms including bacteria, viruses, rickettsiae, parasites, fungi, or prions).
Infectious substances are categorized into Category A or Category B :
Category A Infectious Substances
An infectious substance transported in a form that, when exposure occurs, is capable of causing permanent disability, life-threatening or fatal disease in otherwise healthy humans or animals.
UN 2814: Infectious substance, affecting humans. Examples: Ebola virus, Lassa virus, Marburg virus, Anthrax spores (Bacillus anthracis).
UN 2900: Infectious substance, affecting animals only. Examples: Foot and mouth disease virus, African swine fever virus.
Packaging: Requires UN specification triple packaging meeting Packing Instruction 620 (capable of passing drop tests from 9 meters and puncture tests).
Category B Infectious Substances
An infectious substance that does not meet the criteria for inclusion in Category A.
UN 3373: Biological Substance, Category B. Examples: Routine COVID-19 diagnostic swabs, Hepatitis B blood diagnostic samples, Dengue virus diagnostic specimens.
Packaging: Must be packaged in compliance with Packing Instruction 650 (triple packaging system, leakproof primary and secondary receptacles, 95 kPa pressure differential test rating). Does not require a Shipper's Declaration if compliant.