Study guide
UN Specification Packaging Codes & Performance Tests (Drop, Stacking, Hydraulic Pressure)
IATA Dangerous Goods Regulations Air
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: General Philosophy, Applicability & CBTA Framework
Legal Basis & International Regulatory Framework Shipper & Operator Responsibilities in Air Transport Competency-Based Training & Assessment (CBTA) & Certification Categories Dangerous Goods Security & High Consequence Dangerous Goods
2 Chapter 2: Dangerous Goods Limitations
Forbidden Dangerous Goods & Hidden Dangerous Goods Recognition Passenger & Crew Baggage Provisions (Section 2.3 Provisions Table) State Variations & Operator Variations (Sections 2.8 and 2.9) Excepted Quantities (EQ) & Limited Quantities (LQ) Provisions Operators' Own Property (COMAT) & Dangerous Goods in Air Mail
3 Chapter 3: Classification of the 9 Hazard Classes
Class 1 (Explosives) & Class 2 (Gases) Classification Class 3 (Flammable Liquids) & Class 4 (Flammable Solids, Spontaneous Combustibles, Dangerous When Wet) Class 5 (Oxidizing Substances & Organic Peroxides) & Class 6 (Toxic & Infectious Substances) Class 7 (Radioactive Material) Basics, Activity Limits & Radiation Protection Class 8 (Corrosives) & Class 9 (Miscellaneous Dangerous Goods & Environmentally Hazardous) Packing Groups (PG I, II, III) & Precedence of Hazards Matrix
4 Chapter 4: Identification & List of Dangerous Goods
Navigating Section 4.2 (Blue Pages & Table Columns A–N) Proper Shipping Names, UN/ID Numbers & Technical Name Rules Special Provisions (Section 4.4) & Mixture/Solution Rules Lithium Batteries Identification & Classification (UN 3090, 3091, 3480, 3481) Section 4.3 Numerical Cross-Reference & the End-to-End Lookup Workflow
5 Chapter 5: Packing Requirements & UN Specification Packaging
General Packing Requirements, Single vs. Combination Packaging & Ullage Rules Packing Instructions (PI) Selection & Quantity Limitations UN Specification Packaging Codes & Performance Tests (Drop, Stacking, Hydraulic Pressure) Overpacks, Salvage Packaging & Pressure Differential Standards Dry Ice, Consumer Commodity (ID 8000) & Class-Specific Packing Provisions Infectious Substances in Practice: Packing Instruction 620 and Packing Instruction 650
6 Chapter 6: Marking & Labelling Requirements
DGR 7.1 — Package Marking Requirements DGR 7.2 — Hazard Class & Subsidiary Risk Labels (Specifications & Placement Rules) DGR 7.2 — Handling Labels (Cargo Aircraft Only, Orientation Arrows, Magnetized Material, Cryogenic) DGR 7.1 — Lithium Battery, Excepted Quantity & Limited Quantity Marks
7 Chapter 7: Dangerous Goods Documentation
DGR 8.1 — Shipper's Declaration for Dangerous Goods (SDDG): Structure & Completion Rules DGR 8.2 — Air Waybill Handling Information & Non-Dangerous Goods Declarations DGR Section 8 — Electronic Shipper's Declaration (e-DGD) & Documentation Retention
8 Chapter 8: Stowage, Handling & Emergency Procedures
Cargo Acceptance Checks & Acceptance Checklist Verification Loading Limitations, Cargo Aircraft Only (CAO) & ULD Rules Segregation & Incompatibility Rules (Table 9.3.A Segregation Matrix) Notification to Captain (NOTOC) & Pilot-in-Command Information Dangerous Goods Incidents, Reporting & Emergency Response Procedures Class 7 Radioactive Material: Section 10 Packing, Labelling, Documentation & Stowage
UN Specification Packaging Codes & Performance Tests (Drop, Stacking, Hydraulic Pressure)
Key Takeaways Explain This Topic AI
UN specification packaging codes follow an international standardized marking sequence identifying type, material, performance level, mass/pressure rating, year, authorizing state, and manufacturer code.
Packaging type codes use numbers 1 through 6 (1=Drum, 2=Barrel, 3=Jerrican, 4=Box, 5=Bag, 6=Composite), while material codes use capital letters (A=Steel, B=Aluminum, C=Wood, D=Plywood, G=Fibreboard, H=Plastic).
UN performance letters specify Packing Group authorization: 'X' for PG I, II, III; 'Y' for PG II, III; 'Z' for PG III only.
Mandatory UN performance drop tests require drops from 1.8 meters for PG I, 1.2 meters for PG II, and 0.8 meters for PG III without leakage or rupture.
Single packagings for liquids must pass a design-type hydraulic pressure test of at least 100 kPa (Packing Groups II and III) or 250 kPa (Packing Group I) — a separate requirement from the 95 kPa pressure differential that air transport imposes on inner and single packagings holding liquids.
Last updated: August 2026
UN Specification Packaging Codes & Performance Tests
To ensure packaging safety in international transport, the United Nations Committee of Experts established a standardized certification system. Packagings designed for dangerous goods must be tested, certified, and permanently marked with a UN Specification Packaging Code . In air transport, IATA DGR enforces strict UN specification packaging requirements for most hazard classes.
1. Deciphering the UN Specification Marking System
A UN specification packaging mark is a durable, legible string of codes stamped, printed, or molded onto certified outer packagings. It provides a complete legal and technical record of the packaging's capabilities. Sample UN Marking String:
- u n 4G / X 15 / S / 26 / USA / +AA1234
- - -- ---- - -- --- -------
- | | | | | | |
- | | | | | | +--> Manufacturer / Testing Facility Code
- | | | | | +----------> Authorizing Country Code (USA)
- | | | | +----------------> Year of Manufacture (2026)
- | | | +--------------------> Inner Packagings / Solid ('S') or Test Pressure (kPa)
- | | +-------------------------> Performance Level (X=PG I) & Max Gross Mass (15 kg)
- | +-------------------------------> Packaging Type Code (4G = Fibreboard Box)
- +-----------------------------------> UN Symbol
- Element-by-Element Breakdown
UN Symbol : Small United Nations emblem or lowercase 'un' letters.
Packaging Type Code : Indicates container geometry and construction material (e.g., 4G = Fibreboard Box, 1A1 = Non-removable head steel drum).
Performance Level Letter & Mass/Pressure Rating :
Performance letter ( X , Y , or Z ).
For solids/combination packagings: Maximum allowable gross mass in kilograms (e.g., 15 = 15 kg gross mass).
For single liquid packagings: Maximum hydrostatic test pressure in kilopascals (e.g., 250 = 250 kPa).
Content State Indicator : 'S' for solids or combination packagings containing inner receptacles; or specific gravity for single liquids (e.g., 1.4 ).
Year of Manufacture : Last two digits of the manufacturing year (e.g., 26 for 2026).
Authorizing State Code : Three-letter international vehicle registration code of the state authorizing the mark (e.g., USA , CAN , DEU , GBR ).
Manufacturer / Certification Facility : Registered symbol or code assigned by the national authority (e.g., +AA1234 ).
2. Packaging Type Codes & Material Identifiers
UN packaging codes combine a numerical type code (1 to 6) with a capital letter material code (A to P).
- Numerical Packaging Type Codes
- 1 : Drum
- 2 : Wooden Barrel (Bung)
- 3 : Jerrican
- 4 : Box
- 5 : Bag
- 6 : Composite Packaging
- Capital Letter Material Codes
- A : Steel
- B : Aluminum
- C : Natural Wood
- D : Plywood
- F : Reconstituted Wood
- G : Fibreboard
- H : Plastic Material
- L : Textile
- M : Multi-wall Paper
- P : Glass, Porcelain, or Stoneware
- Comprehensive Packaging Code Reference Matrix
- UN Code Packaging Description Head / Construction Type
- 1A1 Steel Drum Non-removable head (tight-head for liquids)
- 1A2 Steel Drum Removable head (open-head for solids/inners)
- 1G Fibreboard Drum Cylindrical fibreboard body with metal/plastic ends
- 1H1 Plastic Drum Non-removable head
- 1H2 Plastic Drum Removable head
- 3A1 Steel Jerrican Non-removable head
- 3H1 Plastic Jerrican Non-removable head
- 4C1 Natural Wood Box Ordinary wooden construction
- 4D Plywood Box Plywood panel construction
- 4G Fibreboard Box Corrugated or solid fibreboard box
- 4H2 Plastic Box Solid molded plastic box
- 6HA1 Composite Packaging Plastic inner receptacle inside outer steel drum
- 3. UN Performance Level Letter Codes (X, Y, Z)
The performance level letter in the UN mark determines which Packing Groups (PG) the package is legally authorized to carry based on testing severity. +-------------------------------------------------------------------------+
- | UN PERFORMANCE LEVEL HIERARCHY |
- +-------------------+--------------------+--------------------------------+
- | PERFORMANCE CODE | TEST SEVERITY | PERMISSIBLE PACKING GROUPS |
- +-------------------+--------------------+--------------------------------+
- | 'X' | Highest (PG I) | PG I, PG II, and PG III |
- | 'Y' | Medium (PG II) | PG II and PG III Only |
- | 'Z' | Standard (PG III) | PG III Only |
- +-------------------+--------------------+--------------------------------+
Rule of Substitution : A higher-level packaging can always be substituted for a lower-hazard shipment. An X packaging may carry PG I, II, or III goods. A Y packaging may carry PG II or III goods, but never PG I goods. A Z packaging can carry only PG III goods.
4. Mandatory UN Performance Testing Standards
Before a packaging design type can be certified with a UN mark, production samples must pass rigorous design performance tests specified in DGR Section 6.
Drop Test Requirements (DGR 6.3.3)
Packages filled to capacity are dropped onto a smooth, rigid, non-resilient flat surface from a height determined by the target Packing Group:
- Packing Group I (X Rating) : Drop Height = 1.8 Meters (5.9 Feet)
- Packing Group II (Y Rating) : Drop Height = 1.2 Meters (3.9 Feet)
Packing Group III (Z Rating) : Drop Height = 0.8 Meters (2.6 Feet) Drop Test Heights by Packing Group:
- PG I (X): [ 1.8 Meters (5.9 ft) ]
- PG II (Y): [ 1.2 Meters (3.9 ft) ]
- PG III(Z): [ 0.8 Meters (2.6 ft) ]
Temperature Conditioning : Plastic drums, plastic jerricans, and plastic combination inner receptacles must be conditioned at -18°C (0°F) or lower prior to drop testing to evaluate cold embrittlement resistance.
Pass/Fail Criteria : No inner receptacle may leak, and the outer packaging must show no damage affecting transport safety.
Stacking Test Requirements (DGR 6.3.6)
Packagings must withstand a static compressive force applied to the top surface equivalent to the total weight of identical packages stacked to a minimum height of 3.0 meters (9.8 feet) for a period of 24 hours (or 28 days at 40°C for plastic containers).
Pass/Fail Criteria : No leakage from inner receptacles, no buckling, and no structural deformation that would reduce stack stability.
Hydrostatic Pressure Test Requirements (DGR 6.3.5)
Packagings intended to contain liquid dangerous goods must undergo an internal hydraulic pressure test applied for 5 minutes (metal/glass) or 30 minutes (plastic):
Packing Groups II and III : Test pressure of not less than 100 kPa (1 bar) gauge.
Packing Group I : Test pressure of not less than 250 kPa (2.5 bar) gauge.
The required pressure is also derived from the vapour pressure of the intended contents at 55°C; where that calculation gives a higher figure, the higher figure governs.
Pass/Fail Criteria : Zero liquid leakage across the packaging body or closure seals.
Do not confuse the two pressure numbers. The design-type hydraulic test above (100 kPa / 250 kPa) certifies the packaging when it is manufactured. Separately, air transport requires every inner packaging or single packaging containing liquid to withstand an internal pressure differential of at least 95 kPa without leaking — an air-mode operational requirement in Section 5, not part of the UN design-type test.