Study guide
Segregation & Incompatibility Rules (Table 9.3.A Segregation Matrix)
IATA Dangerous Goods Regulations Air
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: General Philosophy, Applicability & CBTA Framework
Legal Basis & International Regulatory Framework Shipper & Operator Responsibilities in Air Transport Competency-Based Training & Assessment (CBTA) & Certification Categories Dangerous Goods Security & High Consequence Dangerous Goods
2 Chapter 2: Dangerous Goods Limitations
Forbidden Dangerous Goods & Hidden Dangerous Goods Recognition Passenger & Crew Baggage Provisions (Section 2.3 Provisions Table) State Variations & Operator Variations (Sections 2.8 and 2.9) Excepted Quantities (EQ) & Limited Quantities (LQ) Provisions Operators' Own Property (COMAT) & Dangerous Goods in Air Mail
3 Chapter 3: Classification of the 9 Hazard Classes
Class 1 (Explosives) & Class 2 (Gases) Classification Class 3 (Flammable Liquids) & Class 4 (Flammable Solids, Spontaneous Combustibles, Dangerous When Wet) Class 5 (Oxidizing Substances & Organic Peroxides) & Class 6 (Toxic & Infectious Substances) Class 7 (Radioactive Material) Basics, Activity Limits & Radiation Protection Class 8 (Corrosives) & Class 9 (Miscellaneous Dangerous Goods & Environmentally Hazardous) Packing Groups (PG I, II, III) & Precedence of Hazards Matrix
4 Chapter 4: Identification & List of Dangerous Goods
Navigating Section 4.2 (Blue Pages & Table Columns A–N) Proper Shipping Names, UN/ID Numbers & Technical Name Rules Special Provisions (Section 4.4) & Mixture/Solution Rules Lithium Batteries Identification & Classification (UN 3090, 3091, 3480, 3481) Section 4.3 Numerical Cross-Reference & the End-to-End Lookup Workflow
5 Chapter 5: Packing Requirements & UN Specification Packaging
General Packing Requirements, Single vs. Combination Packaging & Ullage Rules Packing Instructions (PI) Selection & Quantity Limitations UN Specification Packaging Codes & Performance Tests (Drop, Stacking, Hydraulic Pressure) Overpacks, Salvage Packaging & Pressure Differential Standards Dry Ice, Consumer Commodity (ID 8000) & Class-Specific Packing Provisions Infectious Substances in Practice: Packing Instruction 620 and Packing Instruction 650
6 Chapter 6: Marking & Labelling Requirements
DGR 7.1 — Package Marking Requirements DGR 7.2 — Hazard Class & Subsidiary Risk Labels (Specifications & Placement Rules) DGR 7.2 — Handling Labels (Cargo Aircraft Only, Orientation Arrows, Magnetized Material, Cryogenic) DGR 7.1 — Lithium Battery, Excepted Quantity & Limited Quantity Marks
7 Chapter 7: Dangerous Goods Documentation
DGR 8.1 — Shipper's Declaration for Dangerous Goods (SDDG): Structure & Completion Rules DGR 8.2 — Air Waybill Handling Information & Non-Dangerous Goods Declarations DGR Section 8 — Electronic Shipper's Declaration (e-DGD) & Documentation Retention
8 Chapter 8: Stowage, Handling & Emergency Procedures
Cargo Acceptance Checks & Acceptance Checklist Verification Loading Limitations, Cargo Aircraft Only (CAO) & ULD Rules Segregation & Incompatibility Rules (Table 9.3.A Segregation Matrix) Notification to Captain (NOTOC) & Pilot-in-Command Information Dangerous Goods Incidents, Reporting & Emergency Response Procedures Class 7 Radioactive Material: Section 10 Packing, Labelling, Documentation & Stowage
Segregation & Incompatibility Rules (Table 9.3.A Segregation Matrix)
Key Takeaways Explain This Topic AI
Dangerous goods segregation under IATA DGR Section 9.3.3 and Table 9.3.A prevents dangerous chemical reactions between incompatible hazard classes during air transport.
Segregation rules apply equally to primary hazard labels and all subsidiary risk labels affixed to packages.
Incompatibility is driven by extreme chemical reactions including rapid oxidation of solvents, thermal runaway of peroxides, acidic hydrogen gas evolution, and sympathetic detonation.
Physical stowage requires either separate non-adjacent ULD containerization or a minimum 1.0-meter (3-foot) 3D spatial separation / non-hazardous buffer cargo in loose holds.
Last updated: August 2026
Segregation & Incompatibility Rules (Table 9.3.A Segregation Matrix)
During air transport, packages containing different dangerous goods classes are stowed in close proximity within cargo holds and Unit Load Devices (ULDs). If packaging integrity is compromised due to turbulence, structural impact, or internal pressure changes, leaking chemicals can mix. The interaction of incompatible chemicals can trigger catastrophic inflight emergencies, including violent chemical explosions, rapid fires, generation of toxic gas clouds, or severe structural corrosion. To eliminate these risks, IATA DGR Section 9.3.3 and ICAO Technical Instructions Part 7, Chapter 2 enforce mandatory Segregation Rules centered around Table 9.3.A (Segregation Matrix) .
1. Understanding the IATA DGR Segregation Matrix (Table 9.3.A)
DGR Table 9.3.A dictates whether packages bearing different hazard labels can be stowed adjacent to one another or within the same ULD. The matrix intersects primary and subsidiary hazard classes and divisions. The grid below is a teaching extract showing how the table is read and which pairings drive most real segregation decisions; resolve every live load plan against the printed Table 9.3.A in the current edition, because entries are added and amended between editions: +---------------------------------------------------------------------------------------------------------+
- | IATA DGR TABLE 9.3.A SEGREGATION MATRIX |
- +---------------------------------------------------------------------------------------------------------+
- | HAZARD CLASS / DIVISION | 1.4S | 2.1 | 2.2 | 2.3 | 3 | 4.1 | 4.2 | 4.3 | 5.1 | 5.2 | 6.1 | 8 |
+-------------------------+------+------+------+------+------+------+------+------+------+------+------+------+
- | 1.4S Explosives | - | - | - | - | - | - | - | - | - | - | - | - |
- | 2.1 Flammable Gas | - | - | - | - | - | - | - | - | X | - | - | - |
- | 2.2 Non-Flammable Gas | - | - | - | - | - | - | - | - | - | - | - | - |
- | 2.3 Toxic Gas | - | - | - | - | - | - | - | - | - | - | - | - |
- | 3 Flammable Liquid | - | - | - | - | - | - | - | - | X | - | - | Note1|
- | 4.1 Flammable Solid | - | - | - | - | - | - | - | - | X | - | - | - |
- | 4.2 Spont. Combustible | - | - | - | - | - | - | - | - | X | - | - | Note2|
- | 4.3 Dangerous When Wet | - | - | - | - | - | - | - | - | X | - | - | Note3|
- | 5.1 Oxidizer | - | X | - | - | X | X | X | X | - | - | - | - |
- | 5.2 Organic Peroxide | - | - | - | - | - | - | - | - | - | - | - | - |
- | 6.1 Toxic Substance | - | - | - | - | - | - | - | - | - | - | - | - |
- | 8 Corrosive Substance | - | - | - | - | Note1| - | Note2| Note3| - | - | - | - |
- +---------------------------------------------------------------------------------------------------------+
- | SYMBOL 'X': MUST BE SEGREGATED (Must not be stowed in same ULD or adjacent in loose hold). |
- | SYMBOL '-': NO SEGREGATION REQUIRED (May be stowed adjacent unless special provision applies). |
- +---------------------------------------------------------------------------------------------------------+
- Decoding Matrix Symbols & Notes
Symbol 'X' : Indicates mandatory segregation . Packages bearing these intersecting labels MUST NOT be stowed in the same ULD container or stowed adjacent to each other in a loose cargo hold.
Symbol '-' : Indicates no segregation required . Packages may be stowed together or in the same ULD, provided individual packaging rules are met.
Note 1 : Segregation is required between Class 3 Flammable Liquids and Class 8 Corrosives ONLY IF Class 8 contains acidic liquids (or if Class 3 has a sub-risk of Division 5.1).
Note 2 : Segregation required between Division 4.2 and Class 8 liquids.
Note 3 : Segregation required between Division 4.3 water-reactive substances and Class 8 aqueous corrosive liquids.
2. Chemical Rationale & Reaction Mechanisms of Incompatible Pairings
Regulatory segregation rules are grounded in fundamental chemical thermodynamic principles. Understanding the chemical reactions behind incompatible pairings is critical for dangerous goods certification:
1. Class 1 Explosives vs. ALL Other Hazard Classes
Reaction Mechanism : High explosives (Division 1.1–1.3) contain self-reactive chemical bonds ( N − N O 2 N-NO_2 N − N O 2 , C − N O 2 C-NO_2 C − N O 2 ) capable of detonation via mechanical shock or thermal activation.
Hazard : Stowing Class 1 with flammable liquids (Class 3) or oxidizers (Class 5.1) exposes explosives to external flame sources, inducing Deflagration-to-Detonation Transition (DDT) and causing catastrophic structural destruction of the airframe.
2. Class 3 (Flammable Liquids) vs. Division 5.1 (Oxidizers)
Reaction Mechanism : Organic solvents (e.g., Acetone, Toluene) require atmospheric oxygen ( O 2 O_2 O 2 ) to burn. Division 5.1 oxidizers (e.g., Concentrated Nitric Acid, Calcium Hypochlorite) readily yield active atomic oxygen upon thermal breakdown: 2 HNO 3 → Δ 2 NO 2 + H 2 O + [ O ] 2 \text{HNO}_3 \xrightarrow{\Delta} 2 \text{NO}_2 + \text{H}_2\text{O} + [\text{O}] 2 HNO 3 Δ 2 NO 2 + H 2 O + [ O ]
Hazard : When a leaking oxidizer mixes with a flammable liquid, it supplies concentrated oxygen directly into the liquid matrix. This dramatically lowers ignition temperature, accelerating a minor leak into an uncontrollable, high-intensity chemical conflagration that resists atmospheric oxygen starvation.
3. Division 4.1 / 4.2 / 4.3 vs. Division 5.1 / 5.2 (Thermal Runaway & Oxygen Release)
Reaction Mechanism : Division 4.2 spontaneously combustible materials (e.g., White Phosphorus, Organometallic compounds) autoxidize upon contact with air. Division 5.2 organic peroxides (e.g., Methyl Ethyl Ketone Peroxide) possess unstable O − O O-O O − O peroxide linkages.
Hazard : Contact produces rapid thermal runaway . The peroxide decomposes exothermically while Division 4.2/4.3 acts as a high-density fuel source, causing immediate self-ignition and violent overpressurization of the cargo bay.
4. Class 8 (Corrosives) vs. Division 4.3 (Dangerous When Wet)
Reaction Mechanism : Division 4.3 materials (e.g., Sodium metal, Calcium carbide, Lithium aluminum hydride) react violently with water or aqueous acid solutions to release flammable Hydrogen gas ( H 2 H_2 H 2 ) or Acetylene gas ( C 2 H 2 C_2H_2 C 2 H 2 ): Na + HCl → NaCl + 1 2 H 2 ↑ + Heat \text{Na} + \text{HCl} \rightarrow \text{NaCl} + \frac{1}{2} \text{H}_2 \uparrow + \text{Heat} Na + HCl → NaCl + 2 1 H 2 ↑ + Heat
Hazard : The exothermic acid-metal reaction generates high temperatures that instantly ignite the liberated flammable Hydrogen gas, leading to an explosive air-gas ignition in the hold.
5. Class 8 (Corrosives) vs. Class 3 (Flammable Liquids)
Reaction Mechanism : Concentrated mineral acids (e.g., Sulfuric Acid, Nitric Acid) react with organic solvents via exothermic dehydrations or nitration reactions.
Hazard : Heat generated by acid hydrolysis vaporizes solvent liquids, raising compartment volatile vapor concentrations above the Lower Explosive Limit (LEL) and igniting surrounding cargo.
3. Physical Stowage Separation Rules (Loose Holds vs. ULDs)
When Table 9.3.A indicates an 'X' segregation requirement, load planners must implement physical spatial isolation dependent on cargo hold configuration: +---------------------------------------------------------------------------------+
- | PHYSICAL SEGREGATION METHODS IN AIR TRANSPORT |
- +---------------------------------------------------------------------------------+
METHOD A: LOOSE CARGO HOLD STOWAGE (Bulk Compartment)
- [ Package Class 3 ] <--- MINIMUM 1.0 METER (3 FEET) ---> [ Package Div 5.1 ]
- SPATIAL SEPARATION
- OR
- [ NON-DG BUFFER CARGO BALES ]
-------------------------------------------------------------------------------
METHOD B: UNIT LOAD DEVICE (ULD) CONTAINERIZATION
- +------------------------+ +------------------------+
- | ULD CONTAINER #1 | | ULD CONTAINER #2 |
- | | | |
- | [ Package Class 3 ] | <-- SEPARATE ULDs --> | [ Package Div 5.1 ] |
- | | (Non-adjacent deck) | |
- +------------------------+ +------------------------+
- Bulk / Loose Cargo Hold Requirements
3D Spatial Separation : In bulk lower holds, incompatible packages marked 'X' must be separated by a minimum 1.0 meter (3 feet) three-dimensional spatial distance in all directions (horizontal, vertical, and diagonal).
Non-Hazardous Buffer Cargo : The space between segregated dangerous goods packages may be filled with solid non-dangerous cargo (e.g., baggage, mail sacks, woven textile bales) to act as a physical buffer.
No Stacking : Incompatible packages must never be stacked directly on top of one another or positioned such that liquid leaks from an upper package could drip onto an incompatible lower package.
ULD Containerization Requirements
Separate ULD Mandate : Incompatible packages requiring 'X' segregation MUST NOT be loaded into the same ULD container or onto the same aircraft pallet .
Deck Positioning : ULDs containing mutually incompatible dangerous goods must be loaded into non-adjacent aircraft hold positions.
4. Application to BOTH Primary and Subsidiary Risk Labels
A critical regulatory rule under DGR 9.3.3.2 dictates that segregation rules apply equally to ALL hazard labels displayed on a package , including BOTH primary hazard labels and ALL subsidiary risk labels!
Universal Rule : If a package displays a Primary Label of Class 3 and a Subsidiary Risk Label of Class 8 , load planners must evaluate segregation against Table 9.3.A twice—once for Class 3 AND once for Class 8. If an 'X' appears at EITHER intersection against another package, segregation is legally mandatory!
5. Special Segregation Requirements
Beyond Table 9.3.A, specific dangerous goods classes are subject to extra physical separation requirements:
UN 2807 Magnetized Material (Compass Separation)
Hazard : Magnetized materials (e.g., large permanent magnets, MRI components, radar equipment) emit magnetic field strengths capable of disrupting aircraft fluxgate compasses and navigation sensors.
Separation Requirement : Magnetized material is packed under Packing Instruction 953 and must be stowed clear of the aircraft compass and compass-detector units. The separation distance is not a single universal number — it is derived from the measured field strength of the consignment together with the loading limitations the operator publishes for that aircraft type. Load planners read the required distance from that manual, which is exactly why the compass deflection has to be measured at 2.1 m and declared in the first place.
Class 6.2 Infectious Substances (Foodstuff Separation)
Hazard : Biological contamination of food supplies.
Separation Distance : Under DGR 9.3.4 , packages containing Division 6.2 Infectious Substances (UN 2814, UN 2900, UN 3373) must NOT be stowed in the same compartment or ULD directly adjacent to foodstuffs, animal feeds, or edible commodities.
Class 7 Radioactive Materials (Transport Index Limits)
Cumulative Limits : The sum of the Transport Indexes (TI) of the Class 7 packages carried together must not exceed 50 on a passenger aircraft or 200 on a cargo aircraft. These are the totals the pilot-in-command verifies against the NOTOC.
Separation from Persons and Film : Class 7 Category II-YELLOW and III-YELLOW packages must maintain minimum physical separation distances from cabin floor bulkheads (to protect passengers/crew from ionizing radiation) and undeveloped photographic film per DGR Tables 9.3.C and 9.3.D .
6. Step-by-Step Segregation Execution Workflow
To ensure zero errors during load preparation, load planners follow a 5-step verification workflow:
Step 1 — Extract Manifest Data : List all incoming dangerous goods packages, recording UN Numbers, Primary Classes, and Subsidiary Risks.
Step 2 — Identify Sub-risks : Highlight every package possessing one or more subsidiary risk labels.
Step 3 — Consult Table 9.3.A : Cross-reference every pair of packages against Table 9.3.A for primary vs. primary, primary vs. sub-risk, and sub-risk vs. sub-risk.
Step 4 — Determine Loading Allocation : Assign packages passing matrix checks to shared ULDs; segregate packages returning an 'X' into separate ULDs or 1.0m bulk hold positions.
Step 5 — Physical Ramp Audit : Ramp inspectors visually verify physical package placement against the finalized load sheet.
- 7. Worked Segregation Audit Problem
- Case Study Manifesto Audit
A load planner at a major cargo hub receives four dangerous goods packages for loading onto a Boeing 767-300F freighter:
- Package A : UN 1203, Gasoline, Class 3, PG II (Primary: Class 3)
- Package B : UN 1495, Sodium chlorate, Division 5.1, PG II (Primary: Division 5.1)
Package C : UN 1760, Corrosive liquid, n.o.s. (contains Hydrochloric Acid), Class 8, Sub-risk Division 6.1, PG II (Primary: Class 8, Sub-risk: Division 6.1)
Package D : UN 3480, Lithium ion batteries, Class 9 (Primary: Class 9) +---------------------------------------------------------------------------------+
- | WORKED SEGREGATION AUDIT EVALUATION |
- +---------------------------------------------------------------------------------+
- | PAIRING 1: Package A (Class 3) vs. Package B (Division 5.1) |
- | - Table 9.3.A Intersection (3 vs 5.1): Symbol 'X' |
- | - RESULT: INCOMPATIBLE. Must be segregated! Cannot share ULD or 1.0m hold. |
- | |
- | PAIRING 2: Package A (Class 3) vs. Package C (Class 8 / Sub 6.1) |
- | - Table 9.3.A Intersection (3 vs 8): Note 1 (Acidic liquid). |
- | - Hydrochloric acid is an acidic liquid mineral acid. |
- | - RESULT: INCOMPATIBLE per Note 1. Must be segregated! |
- | |
- | PAIRING 3: Package B (Division 5.1) vs. Package C (Class 8 / Sub 6.1) |
- | - Table 9.3.A Intersection (5.1 vs 8): Symbol '-' |
- | - Check Sub-risk (5.1 vs 6.1): Symbol '-' |
- | - RESULT: COMPATIBLE. Package B and Package C may share the same ULD. |
- | |
- | PAIRING 4: Package D (Class 9) vs. ALL OTHER PACKAGES |
- | - Class 9 does not appear on Table 9.3.A (No mandatory matrix segregation). |
- | - RESULT: COMPATIBLE with A, B, and C. May be stowed adjacent to all items. |
- +---------------------------------------------------------------------------------+
- | FINAL STOWAGE PLAN: |
- | - ULD Position 1: Package B (Div 5.1) + Package C (Class 8/6.1) + Package D (9) |
- | - ULD Position 2 (Non-adjacent): Package A (Class 3) |
- +---------------------------------------------------------------------------------+