Study guide
Chemical Principles for Power Engineers
SOPEEC 4th Class Power Engineer Part 4A — Free Study Guide 2026 Exam
Track your progress as you read
Finished sections get a check mark.
1 Examination and Mechanics Foundations
Examination, Certification and Study Method Applied Mathematics & Units of Measurement Moments, Free-Body Diagrams and Equilibrium Scalars, Graphical Vectors and Force Components
2 Motion, Energy and Plant Drives
Simple Machines and Mechanical Advantage Kinematics and Linear Motion Work, Pressure, Power and Mechanical Energy Dry Friction, Sliding Loads and Friction Power Stress, Strain, Material Behaviour and Safety Factors Belts, Gears, Couplings and Transmitted Power
3 Heat, Thermodynamic Laws and Steam
Heat, Temperature, and Thermal Expansion Thermodynamic Laws and Ideal Gas Calculations Conduction, Convection and Radiation Heat Exchanger Construction, Balances and Operation Thermodynamics of Steam & Steam Tables
4 Chemistry of Plant Fluids
Chemical Principles for Power Engineers
5 Legislation, Canadian Standards and ASME Codes
Jurisdictional Acts, Regulations and Plant Responsibilities Canadian Standards, Registration and Refrigerant Safety ASME Construction, Materials, Examination and Welding Codes
6 Plant Safety and Fire Protection
Plant Hazard Assessment, Worker Rights and PPE Safety Programs, Permits, Isolation and Confined Spaces WHMIS, SDSs and Dangerous-Material Handling Fire Prevention, Detection, Fixed Systems and Emergency Plans Fire Classes, Extinguishing Agents and Portable Response
7 Environment and Plant Emissions
Plant Environmental Impacts, Approvals and Monitoring Gaseous Emissions, Controls and Plant Noise Liquid and Solid Wastes, Containment and Spill Response
8 Materials, Welding and Examination
Ferrous and Nonferrous Materials, Alloys and Heat Treatment Welding Processes, Discontinuities and Hydrogen Control Material Tests and Weld Examination Methods
9 Piping, Valves and Drainage
Piping Dimensions, Materials, Joints, Expansion and Supports Industrial Valves, Non-Return Devices and Reducing Stations Steam Traps, Drainage, Separators and Water Hammer
10 Electrical Principles and Plant Power
Electrical Quantities, DC Circuits, Power and Energy AC Waveforms, Reactance and Power Factor Magnetic Circuits, Electromagnets and Induction Electrical Meter Designs, Connections and Interpretation AC and DC Motors, Generators and Three-Phase Connections Transformer Ratios, Losses, Cooling and Ratings Electrical Distribution, Protection and Station DC Systems
11 Process Measurements and Control Systems
Pressure Sensors, Transmitters and Impulse Connections Mechanical Thermometers, RTDs and Thermocouples Direct and Inferential Liquid-Level Measurement Flow, Humidity and Composition Instruments Control-System Purpose, Feedback and Controller Modes Transmitters, Recorders, Signals and Final Control Elements Boiler Programming, Flame Supervision and Functional Tests Electronic Signal Conditioning, Logic and Digital Controllers Relays, Contactors, Starter Circuits and Electrical Interlocks
12 Sketches, Diagrams and Operating Communication
Equipment Sketches and Plant Line Tracing Plant Diagrams, P&IDs and Instrument Tags Radios, Alarms, Records and Shift Handover
13 Boiler Development and Construction
Boiler Development, Components and Configurations Firetube Designs, Gas Passes, Stays and Bracing Watertube Circulation, Drums and Heat-Recovery Surfaces Resistance-Element and Electrode Boilers Sectional, Coil, Finned-Tube and Condensing Heating Boilers Power and Heating Boiler Code Scopes and Protective Functions
14 Combustion, Fuel, Draft, Feedwater, Blowdown and Cleaning
Combustion Conditions, Air Supply and Flue-Gas Analysis Gas, Liquid and Solid Boiler Fuel Systems Natural, Forced, Induced and Balanced Draft Open and Pressurized Feedwater Systems Continuous and Bottom Blowdown, Discharge and Balances Fireside Deposits, Sootblowers and Offline Cleaning
Chemical Principles for Power Engineers
Key Takeaways Explain This Topic AI
Matter may be an element, compound or mixture; physical separation differs from chemical reaction.
Balance equations by changing coefficients, not chemical subscripts.
Each pH-unit change represents a tenfold change in hydrogen-ion activity.
Galvanic corrosion requires an electrolyte and electrical connection between different electrode areas.
Last updated: October 2026
Modern steam plants operate at high pressures and temperatures where chemical reactions proceed rapidly. A solid grasp of basic chemical principles is vital for the 4th Class Power Engineer to understand fuel combustion, water conditioning, corrosion mitigation, and environmental emissions.
1. The Nature and States of Matter
Matter is anything that occupies physical space and has mass. It exists in three primary physical states depending on temperature and pressure:
Solid: Possesses a fixed volume and rigid shape. Intermolecular forces hold atoms or molecules tightly in crystalline or amorphous lattices with minimal vibrational motion.
Liquid: Possesses a definite volume but conforms to the shape of its container. Molecules have sufficient kinetic energy to slide past one another while remaining bound by cohesive forces.
Gas: Has neither a definite shape nor a fixed volume. Gas molecules possess high kinetic energy and are separated by distances vastly greater than their molecular diameters, expanding freely to fill any enclosed space.
Physical vs. Chemical Changes
Physical Change: A change in the physical state, shape, or appearance of a substance without altering its underlying molecular identity or chemical composition (e.g., liquid water freezing into ice at 0 ∘ C 0^\circ\text{C} 0 ∘ C or boiling into steam at 100 ∘ C 100^\circ\text{C} 10 0 ∘ C ).
Chemical Change: A process in which chemical bonds are broken and new bonds are formed, transforming the original substances (reactants) into entirely new substances (products) with distinct physical and chemical properties (e.g., the rapid oxidation of methane into carbon dioxide and water vapor: CH 4 + 2 O 2 → CO 2 + 2 H 2 O \text{CH}_4 + 2\text{O}_2 \to \text{CO}_2 + 2\text{H}_2\text{O} CH 4 + 2 O 2 → CO 2 + 2 H 2 O ).
Elements, Compounds, and Mixtures
Element: A pure substance composed of only one type of atom that cannot be separated into simpler chemical substances by ordinary chemical methods (e.g., Carbon [ C \text{C} C ], Oxygen [ O 2 \text{O}_2 O 2 ], Iron [ Fe \text{Fe} Fe ]).
Compound: A pure substance consisting of two or more different chemical elements chemically combined in a fixed, definite stoichiometric ratio (e.g., Water [ H 2 O \text{H}_2\text{O} H 2 O ], Sodium Hydroxide [ NaOH \text{NaOH} NaOH ], Calcium Carbonate [ CaCO 3 \text{CaCO}_3 CaCO 3 ]).
Mixture: A physical combination of two or more distinct substances that retain their individual chemical properties and can be physically separated:
Homogeneous Mixture (Solution): Uniform composition throughout (e.g., filtered boiler water containing dissolved sodium sulfite).
Heterogeneous Mixture: Non-uniform composition with visible phase boundaries (e.g., boiler water containing precipitated calcium phosphate sludge or oily emulsion).
2. Atomic Structure & Chemical Bonding
An atom is the smallest fundamental unit of an element that retains the chemical properties of that element. Every atom consists of a dense central nucleus surrounded by a electron cloud described by quantum energy states: STRUCTURE OF AN ATOM
- +---------------------------------------+
- | NUCLEUS: |
- | - Protons (Charge +1, Mass 1 amu) |
- | - Neutrons (Charge 0, Mass 1 amu) |
- +---------------------------------------+
- | (surrounded by)
- +---------------------------------------+
- | ELECTRON SHELLS: |
- | - Electrons (Charge -1, Negligible)|
- | Valence Shell = Outermost Orbit |
- +---------------------------------------+
- Subatomic Particles
Proton: Positively charged particle located inside the nucleus. The number of protons defines the Atomic Number ( Z Z Z ) of an element.
Neutron: Electrically neutral particle located inside the nucleus. The sum of protons and neutrons defines the Atomic Mass Number ( A A A ) .
Electron: Negatively charged particle occupying quantum states associated with discrete energy levels (shells). An electron has a mass approximately 1 / 1836 1/1836 1/1836 that of a proton.
Valence Electrons & Chemical Reactivity
The electrons located in the outermost shell are known as valence electrons . The octet rule is a useful simple model for many main-group compounds: bonding often gives an outer-shell arrangement associated with eight electrons, or two for hydrogen and helium. Transition metals and many other compounds have important exceptions. The drive to fill or empty the valence shell dictates chemical reactivity, valency, and bonding behavior.
Chemical Bonding Mechanisms
Covalent Bonding: The chemical bond formed when two non-metallic atoms share one or more pairs of valence electrons to achieve stable octet configurations (e.g., the bonding between hydrogen and oxygen in H 2 O \text{H}_2\text{O} H 2 O , or carbon and oxygen in CO 2 \text{CO}_2 CO 2 ).
Ionic Bonding: The chemical bond formed through the complete transfer of one or more valence electrons from an electropositive metallic atom to an electronegative non-metallic atom. This electron transfer creates positively charged ions ( cations , such as Na + \text{Na}^+ Na + or Ca 2 + \text{Ca}^{2+} Ca 2 + ) and negatively charged ions ( anions , such as Cl − \text{Cl}^- Cl − or SO 4 2 − \text{SO}_4^{2-} SO 4 2 − ), which are held together by electrostatic attraction (e.g., NaCl \text{NaCl} NaCl , CaSO 4 \text{CaSO}_4 CaSO 4 ).
3. Key Chemical Compounds in Power Plants
Power engineers encounter a standardized inventory of chemical formulas and compounds across combustion systems, water conditioning programs, and flue gas emissions:
Chemical Formula Systematic / Common Name Role and Significance in Power Engineering
H 2 O \text{H}_2\text{O} H 2 O Water / Dihydrogen Monoxide Primary thermodynamic working fluid in steam cycles and cooling systems.
O 2 \text{O}_2 O 2 Oxygen Gas Essential oxidizer for combustion; major source of pitting corrosion in boilers.
N 2 \text{N}_2 N 2 Nitrogen Gas Inert atmospheric carrier gas (about 78% of dry air by volume); forms thermal NO x \text{NO}_x NO x at high flame temperatures.
CO 2 \text{CO}_2 CO 2 Carbon Dioxide Complete combustion product; dissolves in steam condensate to form corrosive carbonic acid.
CO \text{CO} CO Carbon Monoxide Toxic, flammable product of incomplete combustion representing substantial fuel energy loss.
SO 2 \text{SO}_2 SO 2 Sulfur Dioxide Acid gas produced by burning sulfur in fuel; combines with moisture to cause acid rain and cold-end corrosion.
CH 4 \text{CH}_4 CH 4 Methane Primary constituent of natural gas fuel (composition depends on the gas supply).
NaOH \text{NaOH} NaOH Sodium Hydroxide (Caustic Soda) Strong alkaline chemical used to elevate boiler pH; can cause caustic gouging and embrittlement.
HCl \text{HCl} HCl Hydrochloric Acid (Muriatic Acid) Strong acid used in resin bed regeneration and chemical boiler acid-wash cleanings.
H 2 SO 4 \text{H}_2\text{SO}_4 H 2 SO 4 Sulfuric Acid Strong mineral acid formed when SO 3 \text{SO}_3 SO 3 combines with moisture; used in demineralizer regeneration.
CaCO 3 \text{CaCO}_3 CaCO 3 Calcium Carbonate Primary constituent of hard mineral boiler scale and raw water temporary hardness.
Na 2 SO 3 \text{Na}_2\text{SO}_3 Na 2 SO 3 Sodium Sulfite Chemical oxygen scavenger used in low- to medium-pressure boilers (where the approved treatment program specifies it).
Na 3 PO 4 \text{Na}_3\text{PO}_4 Na 3 PO 4 Trisodium Phosphate (TSP) Internal boiler treatment chemical used to precipitate calcium hardness as non-adherent sludge.
4. Balancing Chemical Equations
Every chemical reaction obeys the Law of Conservation of Mass : atoms cannot be created or destroyed during a chemical reaction. Therefore, the total number of atoms of each element on the reactant side (left) must equal the total number of atoms of that element on the product side (right).
Step-by-Step Balancing Rules
Write the correct chemical formulas for all reactants and products. Never change chemical subscripts once formulas are written.
Balance elements that appear in only one reactant and one product first (typically carbon, metals, or sulfur).
Balance hydrogen atoms next.
Balance oxygen atoms last, as oxygen frequently appears in multiple compounds.
Adjust whole-number stoichiometric coefficients placed in front of chemical formulas until all atomic counts balance.
Example 1: Combustion of Methane CH 4 + O 2 → CO 2 + H 2 O (Unbalanced) \text{CH}_4 + \text{O}_2 \to \text{CO}_2 + \text{H}_2\text{O} \quad \text{(Unbalanced)} CH 4 + O 2 → CO 2 + H 2 O (Unbalanced)
Carbon: 1 1 1 on left, 1 1 1 on right (balanced).
Hydrogen: 4 4 4 on left, 2 2 2 on right → \to → multiply H 2 O \text{H}_2\text{O} H 2 O by 2 2 2 : CH 4 + O 2 → CO 2 + 2 H 2 O \text{CH}_4 + \text{O}_2 \to \text{CO}_2 + 2\text{H}_2\text{O} CH 4 + O 2 → CO 2 + 2 H 2 O
Oxygen: 2 2 2 on left, 2 + ( 2 × 1 ) = 4 2 + (2 \times 1) = 4 2 + ( 2 × 1 ) = 4 on right → \to → multiply O 2 \text{O}_2 O 2 by 2 2 2 : CH 4 + 2 O 2 → CO 2 + 2 H 2 O (Balanced) \mathbf{\text{CH}_4 + 2\text{O}_2 \to \text{CO}_2 + 2\text{H}_2\text{O}} \quad \text{(Balanced)} CH 4 + 2 O 2 → CO 2 + 2 H 2 O (Balanced)
Example 2: Oxygen Scavenging with Sodium Sulfite
In boiler feedwater conditioning, sodium sulfite reacts with dissolved oxygen to form sodium sulfate, adding dissolved solids: 2 Na 2 SO 3 + O 2 → 2 Na 2 SO 4 \mathbf{2\text{Na}_2\text{SO}_3 + \text{O}_2 \to 2\text{Na}_2\text{SO}_4} 2 Na 2 SO 3 + O 2 → 2 Na 2 SO 4
Reactants: 4 Na 4\text{ Na} 4 Na , 2 S 2\text{ S} 2 S , 6 + 2 = 8 O 6 + 2 = 8\text{ O} 6 + 2 = 8 O .
Products: 4 Na 4\text{ Na} 4 Na , 2 S 2\text{ S} 2 S , 8 O 8\text{ O} 8 O (balanced).
5. Acids, Bases, Salts & The pH Scale
Water conditioning in steam generation relies fundamentally on controlling acidity and alkalinity.
Definitions
Acid: A substance that dissociates in aqueous solution to release hydrogen ions (protons, H + \text{H}^+ H + or hydronium ions H 3 O + \text{H}_3\text{O}^+ H 3 O + ). Never taste plant chemicals. In dilute aqueous chemistry at 25°C, acids turn blue litmus paper red, react with active metals to liberate hydrogen gas, and have a pH < 7.0 \text{pH} < 7.0 pH < 7.0 .
Base (Alkali): A substance that dissociates in aqueous solution to release hydroxide ions ( OH − \text{OH}^- OH − ) or accepts protons. Never touch chemicals to identify them. Bases turn red litmus paper blue, and have a pH > 7.0 \text{pH} > 7.0 pH > 7.0 .
Salt: An ionic compound formed alongside water during the neutralization reaction between an acid and a base: Acid + Base → Salt + Water \text{Acid} + \text{Base} \to \text{Salt} + \text{Water} Acid + Base → Salt + Water HCl + NaOH → NaCl + H 2 O \text{HCl} + \text{NaOH} \to \text{NaCl} + \text{H}_2\text{O} HCl + NaOH → NaCl + H 2 O
The pH Scale
The pH scale is the negative base-10 logarithm of hydrogen-ion activity. In sufficiently dilute solutions, concentration gives a useful approximation, written below. Values and examples in this subsection use that approximation at 25°C; they are not boiler-treatment targets: pH = − log 10 [ H + ] \text{pH} = -\log_{10}[\text{H}^+] pH = − lo g 10 [ H + ]
Because the scale is logarithmic, each whole pH unit represents a tenfold ( 10 × 10\times 10 × ) change in hydrogen ion concentration:
A solution at pH 5.0 \text{pH } 5.0 pH 5.0 is 10 10 10 times more acidic than a solution at pH 6.0 \text{pH } 6.0 pH 6.0 .
A solution at pH 4.0 \text{pH } 4.0 pH 4.0 is 100 100 100 times ( 10 × 10 10 \times 10 10 × 10 ) more acidic than water at pH 6.0 \text{pH } 6.0 pH 6.0 .
A solution at pH 11.0 \text{pH } 11.0 pH 11.0 has 10 , 000 10,000 10 , 000 times ( 10 4 10^4 1 0 4 ) fewer hydrogen ions than neutral water at pH 7.0 \text{pH } 7.0 pH 7.0 .
pH Value Chemical Character Hydrogen Ion [ H + ] [\text{H}^+] [ H + ] Concentration (mol/L) Common Plant Examples
0.0 0.0 0.0 Strongly Acidic 1.0 = 10 0 1.0 = 10^0 1.0 = 1 0 0 1 M 1\text{ M} 1 M Hydrochloric Acid ( H C l HCl H Cl )
2.0 2.0 2.0 Acidic 10 − 2 10^{-2} 1 0 − 2 Concentrated flue gas acid condensate
4.0 4.0 4.0 Mildly Acidic 10 − 4 10^{-4} 1 0 − 4 Unconditioned steam condensate with dissolved C O 2 CO_2 C O 2
7.0 7.0 7.0 Neutral 10 − 7 10^{-7} 1 0 − 7 Pure demineralized water at 25 ∘ C 25^\circ\text{C} 2 5 ∘ C ( [ H + ] = [ OH − ] [\text{H}^+] = [\text{OH}^-] [ H + ] = [ OH − ] )
8.5 − 9.2 8.5 - 9.2 8.5 − 9.2 Mildly Alkaline 10 − 8.5 − 10 − 9.2 10^{-8.5} - 10^{-9.2} 1 0 − 8.5 − 1 0 − 9.2 Example alkaline solution; not a universal condensate target
14.0 14.0 14.0 Strongly Alkaline 10 − 14 10^{-14} 1 0 − 14 1 M 1\text{ M} 1 M Sodium Hydroxide ( N a O H NaOH N a O H )
7. Electrochemistry of Corrosion & Galvanic Protection
All metallic corrosion in aqueous systems is an electrochemical process requiring four fundamental components to complete a circuit:
Anode: The electrode where oxidation occurs. Metal atoms lose electrons and dissolve into solution as positively charged ions: Fe → Fe 2 + + 2 e − (Metal dissolves / corrodes) \text{Fe} \to \text{Fe}^{2+} + 2e^- \quad \text{(Metal dissolves / corrodes)} Fe → Fe 2 + + 2 e − (Metal dissolves / corrodes)
Cathode: The electrode where reduction occurs. Electrons arriving from the anode are consumed by oxidizing agents in the electrolyte. In oxygenated water: O 2 + 2 H 2 O + 4 e − → 4 OH − (Cathode is protected) \text{O}_2 + 2\text{H}_2\text{O} + 4e^- \to 4\text{OH}^- \quad \text{(Cathode is protected)} O 2 + 2 H 2 O + 4 e − → 4 OH − (Cathode is protected)
Electrolyte: An aqueous solution capable of conducting ions (boiler water or cooling water with dissolved mineral salts).
Metallic Return Path: Physical metallic contact between anode and cathode allowing electrons to flow from anode to cathode.
Rule: Eliminate any one of these four components, and electrochemical corrosion ceases.
A simplified galvanic ordering
The ordering depends on environment and passive-film condition. When two dissimilar metals are immersed in an electrolyte and connected electrically, a galvanic cell is established. The metal that is more chemically active becomes the anode and can corrode preferentially, while the less active (more noble) metal becomes the cathode and is protected: ANODIC (Active / Corroding / Sacrificial)
- ▲ Magnesium & Magnesium Alloys
- │ Zinc (Galvanizing layer / sacrificial plugs)
- │ Aluminum Alloys
- │ Carbon Steel & Cast Iron
- │ Lead-Tin Solders
- │ Brass & Bronze Alloys
- │ Copper
- │ Nickel Alloys
- ▼ Austenitic Stainless Steels (Passive)
- CATHODIC (More noble under the stated conditions)
- Practical Engineering Applications
Sacrificial Anodes: Water boxes of steam surface condensers and raw water strainers frequently install replaceable zinc or magnesium plugs. Because zinc is more anodic than carbon steel and copper-nickel tubes, the zinc sacrificial anode corrodes preferentially, preserving the costly pressure shell and tube sheets.
Dielectric Unions: When connecting copper piping to carbon steel piping (e.g., in domestic hot water or heating loops), power engineers install non-conductive dielectric fittings (insulating thermoplastic sleeves and rubber gaskets). This breaks the electrical return path, reducing the galvanic current when all parallel conductive paths are addressed.
- 8. Worked Engineering Calculations
- Example 1: Molecular Mass of Boiler Water Treatment Chemicals
Problem: Calculate the molecular mass (formula weight) of:
Calcium Carbonate ( CaCO 3 \text{CaCO}_3 CaCO 3 ), the principal scale-forming compound.
Trisodium Phosphate ( Na 3 PO 4 \text{Na}_3\text{PO}_4 Na 3 PO 4 ), used for hardness precipitation.
Atomic Masses: Ca = 40.08 u \text{Ca} = 40.08\text{ u} Ca = 40.08 u , C = 12.01 u \text{C} = 12.01\text{ u} C = 12.01 u , O = 16.00 u \text{O} = 16.00\text{ u} O = 16.00 u , Na = 22.99 u \text{Na} = 22.99\text{ u} Na = 22.99 u , P = 30.97 u \text{P} = 30.97\text{ u} P = 30.97 u .
Solution:
Calcium Carbonate ( CaCO 3 \text{CaCO}_3 CaCO 3 ): M CaCO 3 = ( 1 × 40.08 ) + ( 1 × 12.01 ) + ( 3 × 16.00 ) M_{\text{CaCO}_3} = (1 \times 40.08) + (1 \times 12.01) + (3 \times 16.00) M CaCO 3 = ( 1 × 40.08 ) + ( 1 × 12.01 ) + ( 3 × 16.00 ) M CaCO 3 = 40.08 + 12.01 + 48.00 = 100.09 g/mol M_{\text{CaCO}_3} = 40.08 + 12.01 + 48.00 = 100.09\text{ g/mol} M CaCO 3 = 40.08 + 12.01 + 48.00 = 100.09 g/mol
Trisodium Phosphate ( Na 3 PO 4 \text{Na}_3\text{PO}_4 Na 3 PO 4 ): M Na 3 PO 4 = ( 3 × 22.99 ) + ( 1 × 30.97 ) + ( 4 × 16.00 ) M_{\text{Na}_3\text{PO}_4} = (3 \times 22.99) + (1 \times 30.97) + (4 \times 16.00) M Na 3 PO 4 = ( 3 × 22.99 ) + ( 1 × 30.97 ) + ( 4 × 16.00 ) M Na 3 PO 4 = 68.97 + 30.97 + 64.00 = 163.94 g/mol M_{\text{Na}_3\text{PO}_4} = 68.97 + 30.97 + 64.00 = 163.94\text{ g/mol} M Na 3 PO 4 = 68.97 + 30.97 + 64.00 = 163.94 g/mol
Example 2: Logarithmic pH Ion Concentration Ratio
Problem: A plant operator tests boiler water and finds the pH is 11.0 11.0 11.0 . Untreated raw makeup water enters the plant at neutral pH 7.0 \text{pH } 7.0 pH 7.0 . By what factor is the hydrogen ion concentration [ H + ] [\text{H}^+] [ H + ] lower in the boiler water compared to the raw makeup water?
Solution:
Determine hydrogen ion concentrations from pH = − log 10 [ H + ] \text{pH} = -\log_{10}[\text{H}^+] pH = − lo g 10 [ H + ] : [ H + ] makeup = 10 − 7.0 mol/L [\text{H}^+]_{\text{makeup}} = 10^{-7.0}\text{ mol/L} [ H + ] makeup = 1 0 − 7.0 mol/L [ H + ] boiler = 10 − 11.0 mol/L [\text{H}^+]_{\text{boiler}} = 10^{-11.0}\text{ mol/L} [ H + ] boiler = 1 0 − 11.0 mol/L
Calculate the ratio: Ratio = [ H + ] makeup [ H + ] boiler = 10 − 7.0 10 − 11.0 = 10 ( − 7.0 − ( − 11.0 ) ) = 10 4 = 10 , 000 \text{Ratio} = \frac{[\text{H}^+]_{\text{makeup}}}{[\text{H}^+]_{\text{boiler}}} = \frac{10^{-7.0}}{10^{-11.0}} = 10^{(-7.0 - (-11.0))} = 10^4 = 10,000 Ratio = [ H + ] boiler [ H + ] makeup = 1 0 − 11.0 1 0 − 7.0 = 1 0 ( − 7.0 − ( − 11.0 )) = 1 0 4 = 10 , 000
Result: Boiler water at pH 11.0 \text{pH } 11.0 pH 11.0 contains 10 , 000 10,000 10 , 000 times fewer hydrogen ions (and 10 , 000 10,000 10 , 000 times more hydroxide ions [ OH − ] [\text{OH}^-] [ OH − ] ) than neutral water at pH 7.0 \text{pH } 7.0 pH 7.0 .
Source notes
Official scope and technical references checked 2026-10-17: Reference 1 .