7.1 Electrical Fundamentals: Ohm's Law, Power & Circuit Configurations

TSSA Gas Technician 3 G3

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Safety & Workplace Practices

1.1 Personal Protective Equipment (PPE) & Worksite Hazard Identification 1.2 WHMIS, GHS, Safety Data Sheets (SDS) & Chemical Safety 1.3 Electrical Safety, Lockout/Tagout (LOTO) & Confined Space Awareness

2 Chapter 2: Fasteners, Hand Tools & Power Tools

2.1 Hand Tools for Gas Piping and Mechanical Assembly 2.2 Power Tools, Threading Machines & Mechanical Fasteners

3 Chapter 3: Testing Instruments & Diagnostics

3.1 Pressure Measurement: U-Tube, Inclined & Digital Manometers 3.2 Electrical Multimeters, Combustion Analyzers & Electronic Leak Detectors

4 Chapter 4: Fuel Gas Properties & Combustion Principles

4.1 Chemical & Physical Properties of Natural Gas vs. Propane 4.2 Combustion Chemistry, Flammability Limits & Ignition Temperatures 4.3 Complete vs. Incomplete Combustion, Carbon Monoxide Hazards & Air Requirements

5 Chapter 5: Ontario Acts, Regulations & G.3 Scope of Authority

5.1 Technical Standards and Safety Act & O. Reg. 215/01 Certification 5.2 O. Reg. 211/01, O. Reg. 212/01 & TSSA Code Adoption Documents (CAD) 5.3 Unacceptable Conditions, Warning Notices & Red Tag Procedures

6 Chapter 6: CSA B149 Code Navigation & General Requirements

6.1 CSA B149.1 & CSA B149.2 Scope, Structure & Key Definitions 6.2 General Installation Rules: Instructions, Access, Clearances & Garages (Clause 4)

7 Chapter 7: Introduction to Electricity & Electrical Safety

7.1 Electrical Fundamentals: Ohm's Law, Power & Circuit Configurations 7.2 Line Voltage (120V) vs. Low Voltage (24V), Transformers & Circuit Protection 7.3 Basic Electrical Controls, Switches & Ladder Diagram Schematics

8 Chapter 8: Technical Manuals, Specifications & Architectural Drawings

8.1 Reading Appliance Rating Plates, Certified Manuals & Specifications 8.2 Architectural Blueprints, Mechanical Drawings & Piping Schematics

9 Chapter 9: Customer Relations, Professional Conduct & Documentation

9.1 Professional Communication, Ethics & Customer Service Standards 9.2 Work Orders, Service Documentation & Red Tag Communication

10 Chapter 10: Piping & Tubing Systems: Materials, Joining & Installation

10.1 Piping & Tubing Materials: Steel, Copper, CSST & Plastic 10.2 Pipe Joining Methods: Threading, Flaring, Brazing & Approved Sealants 10.3 Piping Installation: Supports, Hangers, Drip Legs, Dirt Pockets & Valves

11 Chapter 11: Gas Pipe Sizing, Pressure Testing & Purging Procedures

11.1 Gas Pipe & Tubing Sizing Fundamentals (Tables & Pressure Drop) 11.2 Pressure Testing, Leak Testing & the Ontario Test Tag (Clause 6.22) 11.3 Purging Procedures, Safety Protocols & Leak Detection (Clauses 6.23–6.24)

12 Chapter 12: Gas Appliances, Burners & Combustion Air Fundamentals

12.1 Appliance Classifications, Categories (I–IV), Approvals & Clearances 12.2 Atmospheric & Power Burners: Operation, Aeration & Flame Adjustment 12.3 Ignition Systems & Flame Safeguards: Standing Pilot, HSI, DSI, Thermocouples & Flame Rods 12.4 Combustion Air & Basic Venting Requirements (Clause 8)

7.1 Electrical Fundamentals: Ohm's Law, Power & Circuit Configurations

Key Takeaways Explain This Topic AI

Matter and Atomic Structure: All matter is composed of atoms containing positively charged protons, neutral neutrons, and negatively charged electrons; free electrons in the outer valence shell of good electrical conductors (copper, aluminum) enable electric current under an applied electromotive force.

Ohm's Law Relationships: The fundamental relationship V = I × R V = I \times R V = I × R dictates that voltage ( V V V , volts) equals current ( I I I , amperes) multiplied by resistance ( R R R , ohms Ω \Omega Ω ), allowing technicians to diagnose open circuits, short circuits, and failed coils.

Watt's Law & Thermal Conversion: Electrical power ( P P P , watts) is calculated as P = V × I = I 2 R = V 2 R P = V \times I = I^2 R = \frac{V^2}{R} P = V × I = I 2 R = R V 2 ​ ; in electric and dual-fuel heating systems, electrical energy converts to thermal heat at the exact rate of 1 kW = 3412 Btu/h 1\text{ kW} = 3412\text{ Btu/h} 1 kW = 3412 Btu/h ( 1 W ≈ 3.412 Btu/h 1\text{ W} \approx 3.412\text{ Btu/h} 1 W ≈ 3.412 Btu/h ).

Series Circuit Rules: In a series circuit, current is identical across all components ( I T = I 1 = I 2 I_T = I_1 = I_2 I T ​ = I 1 ​ = I 2 ​ ), total resistance is additive ( R T = R 1 + R 2 + … R_T = R_1 + R_2 + \dots R T ​ = R 1 ​ + R 2 ​ + … ), and source voltage divides across loads; an open at any point halts current throughout the entire circuit.

Parallel & Series-Parallel Systems in HVAC: In gas appliances, safety switches (high limit, rollout, pressure switches) are wired in series to interrupt the gas valve, while operational loads (inducer motor, blower motor, igniter) are wired in parallel across line voltage so each receives full nominal 120 VAC 120\text{ VAC} 120 VAC independently.

Last updated: October 2026

Electrical Fundamentals: Ohm's Law, Power & Circuit Configurations

In gas technician practice, modern heating, ventilation, and air conditioning (HVAC) systems are sophisticated electro-mechanical machines. While fuel gas provides the chemical energy for combustion, electrical circuits provide the sensing, sequencing, automated safety control, and motive power required to operate appliances safely and efficiently. Under Ontario's technical standards and the CSA Gas Trade Training Curriculum, a certified Gas Technician 3 (G3) must master foundational electrical theory, understand mathematical circuit relationships, and diagnose circuit behaviors accurately.

1. Atomic Structure and the Nature of Electricity

All physical matter is composed of atoms, which consist of a dense central nucleus containing positively charged protons and electrically neutral neutrons , surrounded by negatively charged electrons orbiting in discrete concentric energy levels or shells.

Valence Electrons and Material Classifications

The outermost shell of any atom is termed the valence shell , and the electrons residing in this shell are valence electrons . The number and mobility of valence electrons dictate the electrical properties of any material:

Conductors: Materials with atoms containing one, two, or three loosely held valence electrons. Under the influence of an external electromotive force, these electrons readily detach from their parent atoms to become free electrons that migrate through the atomic lattice. The most common conductors used in gas heating equipment wiring and motor windings are copper (one valence electron, excellent conductivity, high ductility) and aluminum (three valence electrons, lighter weight, used in some high-voltage service entrance cabling).

Insulators: Materials with atoms containing five, six, seven, or eight tightly bound valence electrons that resist detachment. Insulators exhibit extremely high opposition to electric current, preventing unwanted leakage or shock hazards. Common insulating materials in HVAC equipment include thermoplastic polymers (PVC, nylon, cross-linked polyethylene used on appliance wire harnesses), porcelain or ceramic (used as high-voltage insulator mountings for spark electrodes and flame rods), and synthetic elastomers (neoprene and rubber).

Semiconductors: Materials with four valence electrons that are neither good conductors nor effective insulators in their pure state (e.g., silicon and germanium). When doped with impurities, semiconductors form the basis of solid-state electronic control boards, integrated furnace controllers (IFC), flame rectification amplifier circuits, and microprocessors.

Electron Flow vs. Conventional Current

Historically, early scientists defined current as flowing from positive (+) potential to negative (-) potential (known as conventional current ). In physical reality, atomic physics proves that electric current in metallic conductors consists of the migration of negatively charged free electrons attracted toward a positive electrical potential (known as electron flow theory , flowing from negative to positive). While both conventions are used in engineering, gas technicians must understand polarity relationships when troubleshooting DC flame rectification circuits, rectifier diodes, and solid-state sensors.

2. The Core Electrical Quantities: Voltage, Current, and Resistance

An electrical circuit requires three interrelated physical quantities to function: a driving force, a flowing charge, and a restricting opposition.

Voltage ( V V V or E E E )

Voltage , also termed electromotive force (EMF) or electrical potential difference , is the pressure or electrical force that drives free electrons through a conductor. Voltage represents potential energy per unit charge: 1 Volt = 1 Joule of electrical work per Coulomb of charge 1\text{ Volt} = 1\text{ Joule of electrical work per Coulomb of charge} 1 Volt = 1 Joule of electrical work per Coulomb of charge In fluid or pneumatic analogies, voltage is directly equivalent to fluid pressure (such as gas supply pressure measured in inches of water column, in w.c. \text{in w.c.} in w.c. , or pounds per square inch, psig \text{psig} psig ). Without voltage, no current can flow. Voltage is measured between two points using a voltmeter.

Current ( I I I )

Current is the rate at which electrical charge flows past a given point in a closed electrical circuit. Current is measured in amperes ( A A A or amps \text{amps} amps ), where: 1 Ampere = 1 Coulomb of charge per second ≈ 6.242 × 10 18 electrons per second 1\text{ Ampere} = 1\text{ Coulomb of charge per second} \approx 6.242 \times 10^{18}\text{ electrons per second} 1 Ampere = 1 Coulomb of charge per second ≈ 6.242 × 1 0 18 electrons per second Analogous to the volumetric flow rate of gas through a pipe (measured in cubic feet per hour, cfh \text{cfh} cfh , or cubic meters per hour, m 3 / h \text{m}^3/\text{h} m 3 / h ), current flows only when a complete, uninterrupted conductive loop exists from the voltage source, through an electrical load, and back to the source return. Current is measured in series using an ammeter or non-intrusively via an inductive clamp-on meter around a single energized conductor.

Resistance ( R R R )

Resistance is the physical opposition that a material or device presents to the flow of electric current. It is measured in ohms ( Ω \Omega Ω , the Greek capital letter omega). In an electrical circuit, resistance converts electrical energy into heat, light, or mechanical force. The resistance of any electrical conductor depends on four physical factors:

Material Resistivity ( ρ \rho ρ ): Atomic structure dictates electron mobility (e.g., copper has significantly lower resistivity than iron or nichrome).

Conductor Length ( L L L ): Resistance is directly proportional to length; doubling the length of a wire doubles its electrical resistance.

Cross-Sectional Area ( A A A ): Resistance is inversely proportional to cross-sectional area; a thicker wire (lower AWG number) provides more parallel paths for electrons and has lower resistance.

Temperature ( T T T ): For most pure metals, resistance increases as temperature rises (positive temperature coefficient). In contrast, specialized negative temperature coefficient (NTC) thermistors used as water or air temperature sensors decrease in resistance as temperature rises.

Electrical Quantity Symbol Unit of Measure Unit Symbol Hydraulic / Gas Analogy Measuring Instrument

Voltage (EMF) V V V or E E E Volt V \text{V} V Gas pressure ( in w.c. \text{in w.c.} in w.c. or psig \text{psig} psig ) Voltmeter (in parallel)

Current I I I Ampere A \text{A} A Fuel gas flow rate ( cfh \text{cfh} cfh or m 3 / h \text{m}^3/\text{h} m 3 / h ) Ammeter / Clamp meter

  • Resistance R R R Ohm Ω \Omega Ω Pipe friction / orifice restriction Ohmmeter (power de-energized)
  • Power P P P Watt W \text{W} W Heat release rate ( Btu/h \text{Btu/h} Btu/h or kW \text{kW} kW ) Wattmeter
  • 3. Ohm's Law Principles and Diagnostic Calculations

Formulated by German physicist Georg Ohm, Ohm's Law states that the current flowing through a conductor between two points is directly proportional to the voltage across the two points and inversely proportional to the resistance between them.

The Mathematical Formulas

Ohm's Law is expressed mathematically through three equations: V = I × R I = V R R = V I V = I \times R \qquad I = \frac{V}{R} \qquad R = \frac{V}{I} V = I × R I = R V ​ R = I V ​

Practical Diagnostic Applications in Gas Heating

Technicians apply Ohm's Law daily to evaluate the operational integrity of electrical components:

Calculating Load Resistance

If an atmospheric gas water heater's 24 VAC 24\text{ VAC} 24 VAC redundant solenoid valve draws a measured operating current of 0.40 A 0.40\text{ A} 0.40 A , the internal coil resistance is: R = V I = 24 V 0.40 A = 60 Ω R = \frac{V}{I} = \frac{24\text{ V}}{0.40\text{ A}} = 60\,\Omega R = I V ​ = 0.40 A 24 V ​ = 60 Ω If an ohmmeter placed across the de-energized coil terminals reads 0 Ω 0\,\Omega 0 Ω , the coil winding is short-circuited (which will instantly trip the circuit fuse). If it reads infinite resistance ( ∞ Ω \infty\,\Omega ∞ Ω or "O.L"), the internal copper magnet wire is broken or burned open.

Calculating Inrush and Running Current

A hot surface igniter (HSI) constructed of silicon carbide operates on 120 VAC 120\text{ VAC} 120 VAC . If bench testing with a calibrated digital multimeter indicates a cold resistance of 40 Ω 40\,\Omega 40 Ω , the initial current draw at the moment of energization is: I = V R = 120 V 40 Ω = 3.0 A I = \frac{V}{R} = \frac{120\text{ V}}{40\,\Omega} = 3.0\text{ A} I = R V ​ = 40 Ω 120 V ​ = 3.0 A As the igniter reaches incandescence ( > 1800 ∘ F / 982 ∘ C > 1800^\circ\text{F} / 982^\circ\text{C} > 180 0 ∘ F /98 2 ∘ C ), its resistance rises sharply, causing the steady-state running current to drop to approximately 1.5 A 1.5\text{ A} 1.5 A to 2.0 A 2.0\text{ A} 2.0 A .

Important

Always verify that electrical power is completely disconnected and locked out ( LOTO ) before connecting an ohmmeter to any circuit or component. Applying test leads from an ohmmeter to an energized circuit will blow the internal meter fuse, destroy the multimeter, or cause an electrical arc flash.

4. Electrical Power: Watt's Law and Thermal Conversions

Electrical power ( P P P ) is the rate at which electrical energy is transferred, expended, or converted into another form of energy (such as heat, mechanical rotation, or magnetic flux). Power is measured in watts ( W \text{W} W ) or kilowatts ( 1 kW = 1000 W 1\text{ kW} = 1000\text{ W} 1 kW = 1000 W ).

Watt's Law Formulas

Watt's Law defines power as the product of voltage and current. By substituting Ohm's Law variables ( V = I × R V = I \times R V = I × R and I = V R I = \frac{V}{R} I = R V ​ ), three distinct power equations are derived: P = V × I P = I 2 × R P = V 2 R P = V \times I \qquad P = I^2 \times R \qquad P = \frac{V^2}{R} P = V × I P = I 2 × R P = R V 2 ​

The British Thermal Unit ( Btu \text{Btu} Btu ) and Electrical Heating Equivalent

In Canadian HVAC practice, gas appliances are rated in British Thermal Units per hour ( Btu/h \text{Btu/h} Btu/h ), while electrical auxiliary heating packages, electric water heaters, and heat pump backup elements are rated in kilowatts ( kW \text{kW} kW ). The precise physical conversion factor between electrical power and thermal energy is: 1 Watt ≈ 3.412 Btu/h 1 Kilowatt (kW) = 3412 Btu/h 1\text{ Watt} \approx 3.412\text{ Btu/h} \qquad 1\text{ Kilowatt (kW)} = 3412\text{ Btu/h} 1 Watt ≈ 3.412 Btu/h 1 Kilowatt (kW) = 3412 Btu/h

Practical Example: Electric Duct Heater Sizing

A technician inspects a supplementary electric duct heater installed in a dual-fuel heat pump plenum. The rating plate states 10 kW 10\text{ kW} 10 kW at 240 VAC 240\text{ VAC} 240 VAC single-phase.

Thermal heat output: 10 kW × 3412 Btu/h kW = 34 , 120 Btu/h 10\text{ kW} \times 3412\frac{\text{Btu/h}}{\text{kW}} = 34,120\text{ Btu/h} 10 kW × 3412 kW Btu/h ​ = 34 , 120 Btu/h

Full-load operating current draw: I = P V = 10 , 000 W 240 V ≈ 41.67 A I = \frac{P}{V} = \frac{10,000\text{ W}}{240\text{ V}} \approx 41.67\text{ A} I = V P ​ = 240 V 10 , 000 W ​ ≈ 41.67 A

Hot resistance of the heating element: R = V 2 P = ( 240 V ) 2 10 , 000 W = 57 , 600 10 , 000 = 5.76 Ω R = \frac{V^2}{P} = \frac{(240\text{ V})^2}{10,000\text{ W}} = \frac{57,600}{10,000} = 5.76\,\Omega R = P V 2 ​ = 10 , 000 W ( 240 V ) 2 ​ = 10 , 000 57 , 600 ​ = 5.76 Ω

5. Direct Current (DC) vs. Alternating Current (AC)

Electric current is classified into two distinct forms based on its directional behavior over time:

Direct Current (DC)

In a direct current circuit, electrons flow unidirectionally from the negative terminal to the positive terminal, maintaining a steady, non-reversing polarity.

Sources: Chemical storage batteries, solar photovoltaic panels, thermocouple/thermopile junctions, and solid-state full-wave bridge rectifiers.

Gas Appliance Applications: Millivolt standing pilot systems generate DC voltage ( 25 to 30 mV 25\text{ to }30\text{ mV} 25 to 30 mV from a single thermocouple; 750 mV 750\text{ mV} 750 mV from a thermopile). Electronic flame rectification circuits rectify an AC voltage into a pulsating direct current microampere signal ( 0.5 to 5.0 μ A DC 0.5\text{ to }5.0\,\mu\text{A DC} 0.5 to 5.0 μ A DC ) passing through the ionized gas flame to prove pilot or main burner presence to the ignition control board.

Alternating Current (AC)

In an alternating current circuit, electrons periodically reverse their direction of flow, oscillating back and forth in a sinusoidal pattern.

Frequency: The rate of direction reversal is measured in hertz ( Hz \text{Hz} Hz ), representing cycles per second. In North America (governed by the Canadian Electrical Code and local utility grids), electrical power is standardized at 60 Hz 60\text{ Hz} 60 Hz (60 full sinusoidal cycles per second, where each single cycle takes 1 60 second ≈ 16.67 milliseconds \frac{1}{60}\text{ second} \approx 16.67\text{ milliseconds} 60 1 ​ second ≈ 16.67 milliseconds ).

Peak vs. RMS (Root-Mean-Square) Voltage: Because an AC sine wave continuously varies from zero to positive peak, back to zero, and down to negative peak, a simple arithmetic average of the voltage over a full cycle is zero. To express the true heating and work capacity of an AC waveform, engineers use the Root-Mean-Square (RMS) value (also termed effective voltage ): V RMS = V peak 2 ≈ 0.707 × V peak V peak = V RMS × 2 ≈ 1.414 × V RMS V_{\text{RMS}} = \frac{V_{\text{peak}}}{\sqrt{2}} \approx 0.707 \times V_{\text{peak}} \qquad V_{\text{peak}} = V_{\text{RMS}} \times \sqrt{2} \approx 1.414 \times V_{\text{RMS}} V RMS ​ = 2 ​ V peak ​ ​ ≈ 0.707 × V peak ​ V peak ​ = V RMS ​ × 2 ​ ≈ 1.414 × V RMS ​ When a digital multimeter measures nominal 120 VAC 120\text{ VAC} 120 VAC , it reports the RMS voltage. The actual instantaneous peak voltage reaching the appliance is: V peak = 120 V × 1.414 ≈ 169.7 V V_{\text{peak}} = 120\text{ V} \times 1.414 \approx 169.7\text{ V} V peak ​ = 120 V × 1.414 ≈ 169.7 V The 120 VAC 120\text{ VAC} 120 VAC RMS supply delivers the exact same thermal heating power across a resistive element as a steady 120 VDC 120\text{ VDC} 120 VDC direct current supply.

6. Circuit Configurations: Series, Parallel, and Series-Parallel

How electrical loads and switches are interconnected dictates how voltage, current, and resistance interact across the system.

Series Circuits

In a series circuit , components are connected end-to-end along a single continuous electrical path. There are no branches or alternative routes for current.

Current Rule: Current is identical at every point throughout the circuit: I T = I 1 = I 2 = I 3 = ⋯ = I n I_T = I_1 = I_2 = I_3 = \dots = I_n I T ​ = I 1 ​ = I 2 ​ = I 3 ​ = ⋯ = I n ​

Resistance Rule: Total resistance is the direct mathematical sum of all individual resistances: R T = R 1 + R 2 + R 3 + ⋯ + R n R_T = R_1 + R_2 + R_3 + \dots + R_n R T ​ = R 1 ​ + R 2 ​ + R 3 ​ + ⋯ + R n ​

Voltage Rule: The applied source voltage divides across each component in direct proportion to its resistance: V T = V 1 + V 2 + V 3 + ⋯ + V n V_T = V_1 + V_2 + V_3 + \dots + V_n V T ​ = V 1 ​ + V 2 ​ + V 3 ​ + ⋯ + V n ​

Operational Vulnerability: If any single switch or component in a series string opens or fails, total current immediately drops to zero, and every component in the string ceases operation.

Parallel Circuits

In a parallel circuit , two or more electrical loads or branches are connected across the same two common power conductors (rails).

Voltage Rule: Voltage is identical across every parallel branch: V T = V 1 = V 2 = V 3 = ⋯ = V n V_T = V_1 = V_2 = V_3 = \dots = V_n V T ​ = V 1 ​ = V 2 ​ = V 3 ​ = ⋯ = V n ​

Current Rule: Total circuit current is the sum of the individual branch currents: I T = I 1 + I 2 + I 3 + ⋯ + I n I_T = I_1 + I_2 + I_3 + \dots + I_n I T ​ = I 1 ​ + I 2 ​ + I 3 ​ + ⋯ + I n ​

Resistance Rule: Total equivalent resistance decreases as more branches are added, because each parallel branch provides an additional path for electron flow. Total resistance is always less than the lowest individual branch resistance: 1 R T = 1 R 1 + 1 R 2 + 1 R 3 + ⋯ + 1 R n R T = R 1 × R 2 R 1 + R 2 (for two parallel branches) \frac{1}{R_T} = \frac{1}{R_1} + \frac{1}{R_2} + \frac{1}{R_3} + \dots + \frac{1}{R_n} \qquad R_T = \frac{R_1 \times R_2}{R_1 + R_2}\quad\text{(for two parallel branches)} R T ​ 1 ​ = R 1 ​ 1 ​ + R 2 ​ 1 ​ + R 3 ​ 1 ​ + ⋯ + R n ​ 1 ​ R T ​ = R 1 ​ + R 2 ​ R 1 ​ × R 2 ​ ​ (for two parallel branches)

Operational Independence: If one parallel branch opens or fails, all other branches continue to receive full voltage and operate completely unaffected.

Series-Parallel Systems in Gas Furnaces

Real-world gas appliances are hybrid series-parallel circuits designed to maximize both operational independence and absolute safety:

Safety Circuit (Series Topology): All critical safety switches—including the high-temperature limit switch, flame rollout switches, blower compartment door interlock, and draft inducer pressure switch—are wired in series with each other and with the automated gas valve solenoid coil. If any safety device opens due to an abnormal temperature or draft failure, the series circuit breaks, immediately de-energizing the gas valve and halting fuel delivery.

Operating Loads (Parallel Topology): Major appliance power loads—including the combustion draft inducer motor, circulating air blower motor, hot surface igniter, and step-down control transformer—are wired in parallel across the nominal 120 VAC 120\text{ VAC} 120 VAC line voltage supply. This ensures that each load receives full system voltage ( 120 VAC 120\text{ VAC} 120 VAC ) when called and operates at its designed electrical horsepower and wattage.

Loading diagram... Series Safety Interlocks vs. Parallel Operating Loads in a Gas Appliance