Study guide

4.2 Granular Media Filtration Mechanics & Media Types

California Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: California Water Regulatory Framework & Certification Ladders

1.1 State Water Board & Regional Boards Structure 1.2 Drinking Water Certification: T1-T5 & D1-D5 Requirements 1.3 Wastewater Certification: Grades I-V & OIT Requirements 1.4 Safe Drinking Water Standards, MCLs & Emerging Contaminants 1.5 California Waterworks Standards (Title 22, Chapter 16) 1.6 Public Water System Types, Permits & the Sanitary Survey

2 Chapter 2: California Water Rights, Title 22 & Environmental Policy

2.1 California Title 22 Recycled Water Standards 2.2 California Environmental Quality Act (CEQA) & Proposition 218 2.3 Water Rights & California Water Resources

3 Chapter 3: Drinking Water Source Quality & Coagulation/Flocculation

3.1 Source Water Quality & Watershed Management 3.2 Coagulation Chemistry & Flash Mixing 3.3 Flocculation & Jar Testing 3.4 Wells, Aquifers & Groundwater Hydraulics 3.5 Raw Water Storage, Clearwells & Reservoir Management

4 Chapter 4: Clarification & Granular Media Filtration

4.1 Sedimentation & Advanced Clarification 4.2 Granular Media Filtration Mechanics & Media Types 4.3 Filter Operation, Backwash Cycles & SWTR Compliance

5 Chapter 5: Disinfection, Oxidation & Advanced Water Treatment

5.1 Chlorination Chemistry & Breakpoint Curves 5.2 Disinfection Kinetics & CT Calculations 5.3 Alternative Disinfection: Ozone, UV & Chlorine Dioxide 5.4 Advanced Treatment: Membranes, AOP & PFAS Adsorption 5.5 Chloramination & Nitrification Control 5.6 Iron & Manganese Removal 5.7 Fluoridation Practice & Compliance 5.8 Corrosion Control Treatment & Water Stability 5.9 Taste & Odor Control and Algal Toxin Management

6 Chapter 6: Wastewater Preliminary & Primary Treatment

6.1 Preliminary Treatment: Screening & Grit Removal 6.2 Primary Clarification Operations 6.3 Primary Sludge Characteristics & Pumping 6.4 Stabilization Ponds, Lagoons & Small-Plant Processes

7 Chapter 7: Secondary Biological Treatment & Activated Sludge

7.1 Activated Sludge Process Fundamentals 7.2 Process Control Parameters: F/M, MCRT & SVI 7.3 Activated Sludge Microbiology & Troubleshooting 7.4 Fixed-Film & Hybrid Biological Processes

8 Chapter 8: Biological Nutrient Removal, Water Reuse & Solids Handling

8.1 Biological Nitrogen Removal: Nitrification & Denitrification 8.2 Biological Phosphorus Removal (EBPR) & Chemical Precipitation 8.3 Anaerobic & Aerobic Digestion 8.4 Sludge Thickening, Dewatering & Biosolids Disposal 8.5 Wastewater Disinfection: Chlorination, Dechlorination & UV

9 Chapter 9: Distribution Systems, Collection Networks & Hydraulics

9.1 Hydraulics, Pressure & Flow Dynamics 9.2 Centrifugal Pumps, Motors & VFDs 9.3 Distribution Network Infrastructure & Cross-Connection Control 9.4 Wastewater Collection Systems, SSMP & FOG Management

10 Chapter 10: Laboratory Analytics, Safety & Water Math

10.1 Water & Wastewater Laboratory Methods 10.2 Laboratory Quality Assurance & Regulatory Reporting 10.3 Chemical Safety, Hazardous Gases & Confined Space 10.4 Essential Water & Wastewater Math for Operators

11 Chapter 11: Federal & California Drinking Water Rules

11.1 The Revised Total Coliform Rule & Assessments 11.2 The Lead and Copper Rule and Service Line Replacement 11.3 Surface Water Treatment Rules & Log Removal Credit 11.4 Stage 1 & Stage 2 Disinfection Byproduct Rules 11.5 Secondary MCLs, Notification Levels & Response Levels 11.6 Public Notification, Consumer Confidence Reports & Recordkeeping

12 Chapter 12: Distribution System Design, Demand & Hydraulics

12.1 System Layout, Pressure Zones & Distribution Maps 12.2 Water Demand, Peaking Factors & Fire Flow 12.3 Distribution Storage: Types, Sizing & Turnover 12.4 Head Loss, C-Factor & Distribution Hydraulic Calculations 12.5 Water Hammer, Surge Control & Air Management

13 Chapter 13: Distribution Equipment Operation, Maintenance & Inspection

13.1 Valves: Types, Operation & Exercising Programs 13.2 Fire Hydrants: Types, Testing & Maintenance 13.3 Water Meters: Types, Accuracy & Meter Management 13.4 Instrumentation, In-Line Sensors, Telemetry & SCADA 13.5 Electrical Systems, Motors & Standby Generators 13.6 External Corrosion, Cathodic Protection & Asset Inspection

14 Chapter 14: Water Mains, Piping & Field Construction

14.1 Pipe Materials & Pipe Selection 14.2 Joints, Fittings, Thrust Restraint & Bedding 14.3 Main Installation, Tapping & Service Line Installation 14.4 Leak Detection, Water Loss Auditing & Main Repair 14.5 Main Cleaning & Maintenance: Flushing, Pigging & Lining 14.6 Excavation, Trench Safety & Utility Locating

15 Chapter 15: Disinfecting Distribution Facilities & Maintaining Water Quality

15.1 Water Main Disinfection (AWWA C651) 15.2 Disinfecting Storage Reservoirs (C652) & Wells (C654) 15.3 Maintaining Distribution Water Quality: Residual, Biofilm & Discolored Water 15.4 Cross-Connection Control Program Administration & Device Testing

16 Chapter 16: Plant Equipment, Chemical Feed & Maintenance

16.1 Chemical Feed Systems: Metering Pumps, Dry Feeders & Calibration 16.2 Gas Chlorination Equipment & Hypochlorite Systems 16.3 Blowers, Compressors & Aeration Equipment 16.4 Flow Measurement Devices: Meters, Weirs & Flumes 16.5 Preventive Maintenance, CMMS & Asset Management

17 Chapter 17: Utility Management, Administration & Emergency Response

17.1 Planning, Organizing, Directing & Controlling a Utility Work Group 17.2 Budgets, Water Rates & Financial Management 17.3 Operator Training, Staffing & Safety Program Development 17.4 Energy Management & Optimization 17.5 Emergency Response Planning, Risk & Resilience & Security 17.6 Water Conservation Planning & Drought Response

18 Chapter 18: Applied Operator Mathematics Workshop

18.1 The Exam Conversion Sheet, Units & Dimensional Analysis 18.2 Distribution & Hydraulic Math Workshop 18.3 Treatment & Wastewater Process Math Workshop

4.2 Granular Media Filtration Mechanics & Media Types

Key Takeaways Explain This Topic AI

Granular media filtration removes non-settleable particles and protozoan pathogens (Giardia, Cryptosporidium) via two sequential stages: physical transport (straining, sedimentation, impaction, interception, diffusion) and chemical attachment (charge neutralization, van der Waals adsorption).

Filter bed configurations evolve from single-medium sand (surface blinding, 12–24 hr runs) to dual-media (anthracite over sand, 36–60 hr runs) and multimedia (anthracite, sand, garnet), establishing a tapered pore geometry for deep-bed solids storage and high-rate loading (3–6 gpm/ft²).

Granular Activated Carbon (GAC) functions as a dual-purpose filter-adsorber, providing particulate filtration alongside empty bed contact time (EBCT 10–20 min) for adsorbing dissolved organic carbon (TOC), MIB/geosmin odorants, and PFAS until carbon exhaustion.

Filter media sizing is defined by Effective Size (d10) and Uniformity Coefficient (UC = d60/d10 < 1.4–1.5), while post-backwash hydraulic re-stratification is controlled by Specific Gravity (anthracite 1.4–1.6, sand 2.65, garnet 3.8–4.2) offsetting grain size differences.

Underdrain systems collect filtered water and distribute backwash water/air scour uniformly; modern dual-lateral plastic blocks with porous sintered caps eliminate graded support gravel, completely preventing gravel mounding and media boiling.

Last updated: August 2026

Particle Removal Mechanisms in Granular Media Filters

Granular media filtration is the final and most critical physical barrier against microbial pathogens—specifically protozoan parasites such as Giardia lamblia cysts (4–14 µm) and Cryptosporidium parvum oocysts (3–7 µm)—under the California Surface Water Treatment Rule. While sedimentation removes the vast bulk of flocculated solids, granular filters capture the remaining non-settleable microscopic turbidity down to sub-micron scales.

Filtration within a granular bed does not function merely as a simple surface sieve or kitchen strainer. Instead, particle removal occurs throughout the entire depth of the bed through two sequential steps: Transport and Attachment . [GRANULAR FILTRATION REMOVAL MECHANISMS]

  • ┌─────────────────────────────────────────────────────────────────────────────────────────────┐
  • │ 1. TRANSPORT MECHANISMS (Moving particles to grain surfaces) │
  • │ • Mechanical Straining: Interstitial pores physically smaller than particle diameter. │
  • │ • Sedimentation: Particles settle onto media grains within interstitial pore voids. │
  • │ • Impaction & Interception: Fluid streamlines diverge; particle inertia causes collision.│
  • │ • Hydrodynamic Diffusion / Brownian Motion: Sub-micron particles collide via thermal motion.│
  • ├─────────────────────────────────────────────────────────────────────────────────────────────┤
  • │ 2. ATTACHMENT MECHANISMS (Securing particles to media grains) │
  • │ • Electrostatic Attraction: Coagulation reduces negative zeta potential toward zero. │
  • │ • van der Waals Forces: Universal short-range electrodynamic attractive forces. │
  • │ • Chemical / Polymer Bridging: Long-chain coagulant aids bind particle to media surface. │
  • └─────────────────────────────────────────────────────────────────────────────────────────────┘
  • Detailed Transport & Attachment Mechanisms

Mechanical Straining: Particles larger than the interstitial pore openings between media grains are physically trapped. Straining occurs predominantly in the top 1 to 2 inches of the filter bed. While 100% effective for oversized particles, excessive surface straining forms a dense "filter cake" or surface mat that rapidly spikes head loss.

Sedimentation within Pores: Interstitial spaces between media grains act as microscopic sedimentation basins. Low laminar velocities allow suspended micro-particles to settle vertically under gravity onto the upward-facing surfaces of media grains.

Inertial Impaction & Interception: As water flows through the tortuous void pathways, streamlines bend around media grains. Particles with sufficient mass and inertia cross the streamlines and strike the media surface ( impaction ), while particles following a streamline passing within one particle radius ( r r r ) of a media grain touch and stick ( interception ).

Brownian Diffusion: For sub-micron colloidal particles (<1.0 µm), thermal energy induces random Brownian motion. These micro-collisions cause particles to wander across fluid streamlines and contact media grains.

Electrostatic & van der Waals Adsorption: Media grains (silica sand and anthracite) naturally carry a negative surface charge in water. Colloidal particles are also negatively charged. Proper upstream chemical coagulation is indispensable: coagulants (alum, ferric, cationic polymer) neutralize negative zeta potentials, allowing attractive short-range van der Waals forces to firmly bond the particle to the media grain.

Loading diagram... Dual-Media & Multimedia Granular Bed Stratification

Filter Media Configurations: Single-Medium to GAC Adsorbers

The evolution of granular filter design addresses a fundamental hydraulic challenge: how to utilize the entire depth of the filter bed for solids storage without clogging the top few inches. [SINGLE-MEDIUM SAND] [DUAL-MEDIA (Deep Bed)] [MULTIMEDIA (Tapered Pore)]

  • ┌─────────────────────┐ ┌─────────────────────┐ ┌─────────────────────┐
  • │ Fine Sand (Top) │ ◄ Blinding │ Coarse Anthracite │ ◄ 80% Load │ Coarse Anthracite │ (SG 1.5)
  • │ │ │ (Low SG = 1.5) │ Captured ├─────────────────────┤
  • │ Coarse Sand │ ├─────────────────────┤ in Depth │ Medium Silica Sand │ (SG 2.65)
  • │ (Ineffective Bottom)│ │ Fine Silica Sand │ ├─────────────────────┤
  • └─────────────────────┘ │ (High SG = 2.65) │ ◄ Polishing │ Fine Garnet │ (SG 4.0)
  • Short Runs (12–24 hr) └─────────────────────┘ └─────────────────────┘
  • Long Runs (36–72 hr) Superior Turbidity Polish
  • Comparison of Filter Bed Configurations

Configuration Media Layers & Depths Effective Grain Size ( d 10 d_{10} d 10 ​ ) Operational Characteristics & Run Times

Single-Medium (Rapid Sand) 24–30 in Silica Sand 0.45 to 0.55 mm 0.45\text{ to }0.55\text{ mm} 0.45 to 0.55 mm ( S G = 2.65 SG = 2.65 SG = 2.65 ) After backwash, fine sand settles on top and coarse sand sinks to the bottom (hydraulic grading). The top 2 inches traps all floc → \rightarrow → rapid head loss accumulation, surface cake formation, short run times ( 12–24 hours ), low loading rates ( 2 – 3 gpm/ft 2 2\text{--}3\text{ gpm/ft}^2 2 – 3 gpm/ft 2 ).

Dual-Media 18–24 in Anthracite Coal over 8–12 in Silica Sand Anthracite: 0.8 – 1.2 mm 0.8\text{--}1.2\text{ mm} 0.8 – 1.2 mm ; Sand: 0.45 – 0.55 mm 0.45\text{--}0.55\text{ mm} 0.45 – 0.55 mm Coarse, low-density anthracite sits on top of fine, high-density sand. Coarse anthracite provides massive solids storage (trapping 70–80% of turbidity in depth), while fine sand provides final barrier polishing. Run times double to 36–60 hours at loading rates of 3–6 gpm/ft² .

Multimedia / Tri-Media 18 in Anthracite over 9 in Silica Sand over 3–6 in Garnet Anthracite: 1.0 mm 1.0\text{ mm} 1.0 mm ; Sand: 0.5 mm 0.5\text{ mm} 0.5 mm ; Garnet: 0.2 – 0.3 mm 0.2\text{--}0.3\text{ mm} 0.2 – 0.3 mm Three-layer density stratification creates the ideal "tapered pore geometry": largest pore openings at the top, progressively tightening to microscopic pore openings in the bottom dense garnet layer ( S G = 3.8 – 4.2 SG = 3.8\text{--}4.2 SG = 3.8 – 4.2 ). Exceptional pathogen/turbidity capture at high rates ( 4–8 gpm/ft² ).

GAC Filter-Adsorber 24–48 in Granular Activated Carbon (replacing anthracite) over 6–12 in Sand GAC: 0.8 – 1.1 mm 0.8\text{--}1.1\text{ mm} 0.8 – 1.1 mm ( S G = 1.3 – 1.5 SG = 1.3\text{--}1.5 SG = 1.3 – 1.5 ) Dual-purpose: physical filtration + adsorption of dissolved organic matter (TOC), MIB/geosmin taste and odor, DBP precursors, and PFAS compounds. Requires Empty Bed Contact Time (EBCT) of 10–20 minutes for organic adsorption. Media must be periodically reactivated or replaced as adsorption sites exhaust (every 1–3 years).

Media Properties: Effective Size, Uniformity Coefficient & Stratification

Filter media quality is strictly specified by two standardized parameters derived from sieve analysis curves (ASTM C136): [GRAIN SIZE DISTRIBUTION CURVE]

  • 100 ┌────────────────────────────────────────────────────────┐
  • │ / │
  • 80 │ / │
  • Percent 60 │───────────────────────────────────────────────/ (d60) │
  • Passing │ / │
  • by Weight │ / │
  • 20 │ / │
  • 10 │───────────────────────────────────────/ (d10 = ES) │
  • 0 └───────────────────────────────────────┴────────────────┘
  • 0.1 1.0 10.0
  • Sieve Opening Size (mm)
  • 1. Effective Size ( d 10 d_{10} d 10 ​ or ES)

The Effective Size is defined as the sieve opening size (in millimeters) that permits 10% by weight of the media sample to pass through, while retaining 90%.

Governs the minimum pore size and directly controls clean bed head loss and initial particle capture efficiency.

Standard specifications: Silica sand ES = 0.45 to 0.55 mm ; Anthracite ES = 0.80 to 1.20 mm ; Garnet ES = 0.20 to 0.30 mm .

2. Uniformity Coefficient ( U C UC U C )

The Uniformity Coefficient is a dimensionless ratio quantifying the variation in particle sizes across the media batch: U C = d 60 d 10 UC = \frac{d_{60}}{d_{10}} U C = d 10 ​ d 60 ​ ​

Where:

d 60 d_{60} d 60 ​ = Sieve opening size (mm) passing 60% by weight of the media.

d 10 d_{10} d 10 ​ = Effective size (mm) passing 10% by weight of the media.

Significance of UC: A low UC ( U C ≤ 1.40 to 1.50 UC \le 1.40\text{ to }1.50 U C ≤ 1.40 to 1.50 ) indicates a highly uniform media with minimal size variation. High UC values ( U C > 1.7 UC > 1.7 U C > 1.7 ) indicate mixed grain sizes where tiny "fines" migrate to the bed surface during backwash, causing premature head loss, while large coarse grains settle to the bottom and contribute zero filtration benefit.

3. Specific Gravity ( S G SG SG ) & Hydraulic Re-Stratification

The physical law governing multi-layer filter design is that differences in specific gravity must offset differences in grain diameter to ensure proper re-stratification after high-rate backwash fluidization. Settling Velocity: v s ∝ d 2 ( ρ media − ρ water ) \text{Settling Velocity: } v_s \propto d^2 (\rho_{\text{media}} - \rho_{\text{water}}) Settling Velocity: v s ​ ∝ d 2 ( ρ media ​ − ρ water ​ )

Anthracite Coal: Specific Gravity = 1.40 to 1.60 (Coarse grain d = 1.0 mm d = 1.0\text{ mm} d = 1.0 mm , but low density → \rightarrow → settles slowest, stays on TOP).

Silica Sand: Specific Gravity = 2.65 (Medium grain d = 0.5 mm d = 0.5\text{ mm} d = 0.5 mm , medium density → \rightarrow → settles in MIDDLE).

Garnet / Ilmenite: Specific Gravity = 3.80 to 4.20 (Fine grain d = 0.25 mm d = 0.25\text{ mm} d = 0.25 mm , but extremely heavy density → \rightarrow → settles fastest, stays on BOTTOM).

Hydraulic Re-Stratification Guarantee: During backwash, the entire bed expands and mixes into a fluidized slurry. When backwash flow is gradually ramped down, the dense garnet settles first to form the bottom layer, the silica sand settles next to form the middle layer, and the light anthracite settles last to form the top layer. Perfect deep-bed stratification is restored automatically.

Filter Media Physical Properties: Specific Gravity & Effective Size

Filter Underdrain Systems & Support Gravel

Located beneath the granular media, the underdrain system serves two critical, opposing hydraulic functions:

Filtration Mode: Collects filtered water uniformly across the entire floor area without generating dead spots or localized high-velocity funnels.

Backwash Mode: Distributes high-pressure backwash water and auxiliary scour air perfectly evenly across the entire underside of the media bed to prevent localized boiling, channeling, or unwashed dead zones.

  • Types of Underdrain Systems [TRADITIONAL LATERAL & GRAVEL] [MODERN BLOCK UNDERDRAIN]
  • ┌─────────────────────────────────┐ ┌─────────────────────────────────┐
  • │ Granular Media Bed (Sand/Anth) │ │ Granular Media Bed (Sand/Anth) │
  • ├─────────────────────────────────┤ ├─────────────────────────────────┤
  • │ Graded Support Gravel (12-18") │ │ Sintered Porous Cap (No Gravel!)│
  • ├─────────────────────────────────┤ ├─────────────────────────────────┤
  • │ Perforated Pipe Laterals │ │ Dual-Lateral HDPE Plastic Block │
  • └─────────────────────────────────┘ └─────────────────────────────────┘
  • Risk: Gravel Mounding / Boiling Advantage: Zero Gravel Displacement

Perforated Pipe Laterals with Graded Gravel Support:

Consists of a central header pipe connected to perforated lateral pipes with orifices pointing downward.

Requires 12 to 18 inches of graded support gravel arranged in 4 to 5 distinct layers (ranging from 1.5-inch coarse gravel at the bottom down to 1/16-inch pea gravel directly beneath the sand).

Vulnerability: If backwash valves open too quickly or air scour surges, high-velocity jets displace the gravel layer ( gravel mounding ). Fine media sifts downward into the laterals, while raw water channels through the displaced gravel, causing irreversible filter failure.

Wheeler Bottoms:

Concrete false floor containing inverted pyramidal depressions filled with porcelain spheres (five 3-inch spheres at the base, topped by smaller porcelain marbles).

Requires a reduced gravel layer; provides stable distribution but is labor-intensive to install and repair.

Modern Plastic Block Underdrains (e.g., Leopold / Roberts Filter Blocks):

Modular, dual-lateral high-density polyethylene (HDPE) blocks with primary and secondary compensating chambers.

Sintered Porous Polyethylene Caps: Porous caps with bead openings smaller than the sand grains ( < 0.2 mm <0.2\text{ mm} < 0.2 mm ) are sonic-welded directly to the top of the block.

Revolutionary Advantage: Completely eliminates the support gravel layer. Media rests directly on the porous cap, eliminating all risks of gravel displacement, gravel mounding, and media boiling.

Filtration Rates & Hydraulic Capacity Calculations

Filtration loading rates measure the volume of water filtered per minute per square foot of filter bed surface area: Filtration Rate (gpm/ft 2 ) = Filter Flow Rate (gpm) Filter Surface Area ( ft 2 ) = Q ( gpd ) 1 , 440 min/day × Area ( ft 2 ) \text{Filtration Rate (gpm/ft}^2\text{)} = \frac{\text{Filter Flow Rate (gpm)}}{\text{Filter Surface Area (}\text{ft}^2\text{)}} = \frac{Q (\text{gpd})}{1,440 \text{ min/day} \times \text{Area (}\text{ft}^2\text{)}} Filtration Rate (gpm/ft 2 ) = Filter Surface Area ( ft 2 ) Filter Flow Rate (gpm) ​ = 1 , 440 min/day × Area ( ft 2 ) Q ( gpd ) ​

Standard Regulatory Filtration Rates

Slow Sand Filtration: 0.05 to 0.15 gpm/ft² (biological Schmutzdecke maturation; no chemical coagulant).

Conventional Rapid Sand Filtration: 2.0 to 3.0 gpm/ft² .

High-Rate Dual / Multimedia Filtration: 3.0 to 6.0 gpm/ft² (standard California DDW approved rating).

Demonstration High-Rate Filtration: Up to 8.0 gpm/ft² (requires rigorous on-site pilot demonstration, continuous coagulant control, and specific SWRCB DDW permit approval).

  • Operational Case Scenarios
  • Scenario 1: Media Intermixing Diagnosis Following Aggressive Backwash

Situation: Following a plant upgrade where backwash pump speeds were increased, operators notice that the dual-media filter is experiencing premature turbidity breakthrough after only 14 hours of run time. Core sampling reveals that the top 6 inches of the bed is a homogenous mixture of fine sand and anthracite. Root Cause Analysis: The high-rate backwash flow was terminated abruptly by slamming the backwash valve shut rather than executing a gradual 2-to-3 minute flow ramp-down. The sudden collapse of the fluidized bed trapped fine sand grains in the settling anthracite coal before hydraulic density separation could occur. Corrective Action: Re-fluidize the filter bed at full backwash rate for 5 minutes, then initiate a controlled, programmed ramp-down (deceleration) over 180 seconds. The gradual reduction in fluid velocity allows the heavy sand ( S G = 2.65 SG = 2.65 SG = 2.65 ) to settle completely before the lighter anthracite ( S G = 1.50 SG = 1.50 SG = 1.50 ) deposits on top, fully restoring the dual-media layer boundary.

Scenario 2: GAC Filter-Adsorber Capacity Exhaustion

Situation: A surface water plant utilizes 36 inches of GAC over 8 inches of sand. During late summer, lake MIB/geosmin levels rise to 45 ng/L. Although filter effluent turbidity remains pristine at 0.03 NTU, consumer complaints surge regarding musty odors, and finished water MIB is measured at 22 ng/L. Analysis: GAC operates as a dual-function medium: physical particulate removal continues indefinitely via mechanical transport/attachment, but chemical adsorption capacity is finite. The carbon's internal micropore adsorption sites have reached organic saturation (adsorption exhaustion). Operator Action: GAC exhaustion does not impair turbidity filtration, but requires chemical pre-treatment. Initiate supplemental Powdered Activated Carbon (PAC) dosing at the flash mix or schedule a thermal reactivation/media change-out of the exhausted virgin GAC bed.