Study guide

5.9 Taste & Odor Control and Algal Toxin Management

California Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: California Water Regulatory Framework & Certification Ladders

1.1 State Water Board & Regional Boards Structure 1.2 Drinking Water Certification: T1-T5 & D1-D5 Requirements 1.3 Wastewater Certification: Grades I-V & OIT Requirements 1.4 Safe Drinking Water Standards, MCLs & Emerging Contaminants 1.5 California Waterworks Standards (Title 22, Chapter 16) 1.6 Public Water System Types, Permits & the Sanitary Survey

2 Chapter 2: California Water Rights, Title 22 & Environmental Policy

2.1 California Title 22 Recycled Water Standards 2.2 California Environmental Quality Act (CEQA) & Proposition 218 2.3 Water Rights & California Water Resources

3 Chapter 3: Drinking Water Source Quality & Coagulation/Flocculation

3.1 Source Water Quality & Watershed Management 3.2 Coagulation Chemistry & Flash Mixing 3.3 Flocculation & Jar Testing 3.4 Wells, Aquifers & Groundwater Hydraulics 3.5 Raw Water Storage, Clearwells & Reservoir Management

4 Chapter 4: Clarification & Granular Media Filtration

4.1 Sedimentation & Advanced Clarification 4.2 Granular Media Filtration Mechanics & Media Types 4.3 Filter Operation, Backwash Cycles & SWTR Compliance

5 Chapter 5: Disinfection, Oxidation & Advanced Water Treatment

5.1 Chlorination Chemistry & Breakpoint Curves 5.2 Disinfection Kinetics & CT Calculations 5.3 Alternative Disinfection: Ozone, UV & Chlorine Dioxide 5.4 Advanced Treatment: Membranes, AOP & PFAS Adsorption 5.5 Chloramination & Nitrification Control 5.6 Iron & Manganese Removal 5.7 Fluoridation Practice & Compliance 5.8 Corrosion Control Treatment & Water Stability 5.9 Taste & Odor Control and Algal Toxin Management

6 Chapter 6: Wastewater Preliminary & Primary Treatment

6.1 Preliminary Treatment: Screening & Grit Removal 6.2 Primary Clarification Operations 6.3 Primary Sludge Characteristics & Pumping 6.4 Stabilization Ponds, Lagoons & Small-Plant Processes

7 Chapter 7: Secondary Biological Treatment & Activated Sludge

7.1 Activated Sludge Process Fundamentals 7.2 Process Control Parameters: F/M, MCRT & SVI 7.3 Activated Sludge Microbiology & Troubleshooting 7.4 Fixed-Film & Hybrid Biological Processes

8 Chapter 8: Biological Nutrient Removal, Water Reuse & Solids Handling

8.1 Biological Nitrogen Removal: Nitrification & Denitrification 8.2 Biological Phosphorus Removal (EBPR) & Chemical Precipitation 8.3 Anaerobic & Aerobic Digestion 8.4 Sludge Thickening, Dewatering & Biosolids Disposal 8.5 Wastewater Disinfection: Chlorination, Dechlorination & UV

9 Chapter 9: Distribution Systems, Collection Networks & Hydraulics

9.1 Hydraulics, Pressure & Flow Dynamics 9.2 Centrifugal Pumps, Motors & VFDs 9.3 Distribution Network Infrastructure & Cross-Connection Control 9.4 Wastewater Collection Systems, SSMP & FOG Management

10 Chapter 10: Laboratory Analytics, Safety & Water Math

10.1 Water & Wastewater Laboratory Methods 10.2 Laboratory Quality Assurance & Regulatory Reporting 10.3 Chemical Safety, Hazardous Gases & Confined Space 10.4 Essential Water & Wastewater Math for Operators

11 Chapter 11: Federal & California Drinking Water Rules

11.1 The Revised Total Coliform Rule & Assessments 11.2 The Lead and Copper Rule and Service Line Replacement 11.3 Surface Water Treatment Rules & Log Removal Credit 11.4 Stage 1 & Stage 2 Disinfection Byproduct Rules 11.5 Secondary MCLs, Notification Levels & Response Levels 11.6 Public Notification, Consumer Confidence Reports & Recordkeeping

12 Chapter 12: Distribution System Design, Demand & Hydraulics

12.1 System Layout, Pressure Zones & Distribution Maps 12.2 Water Demand, Peaking Factors & Fire Flow 12.3 Distribution Storage: Types, Sizing & Turnover 12.4 Head Loss, C-Factor & Distribution Hydraulic Calculations 12.5 Water Hammer, Surge Control & Air Management

13 Chapter 13: Distribution Equipment Operation, Maintenance & Inspection

13.1 Valves: Types, Operation & Exercising Programs 13.2 Fire Hydrants: Types, Testing & Maintenance 13.3 Water Meters: Types, Accuracy & Meter Management 13.4 Instrumentation, In-Line Sensors, Telemetry & SCADA 13.5 Electrical Systems, Motors & Standby Generators 13.6 External Corrosion, Cathodic Protection & Asset Inspection

14 Chapter 14: Water Mains, Piping & Field Construction

14.1 Pipe Materials & Pipe Selection 14.2 Joints, Fittings, Thrust Restraint & Bedding 14.3 Main Installation, Tapping & Service Line Installation 14.4 Leak Detection, Water Loss Auditing & Main Repair 14.5 Main Cleaning & Maintenance: Flushing, Pigging & Lining 14.6 Excavation, Trench Safety & Utility Locating

15 Chapter 15: Disinfecting Distribution Facilities & Maintaining Water Quality

15.1 Water Main Disinfection (AWWA C651) 15.2 Disinfecting Storage Reservoirs (C652) & Wells (C654) 15.3 Maintaining Distribution Water Quality: Residual, Biofilm & Discolored Water 15.4 Cross-Connection Control Program Administration & Device Testing

16 Chapter 16: Plant Equipment, Chemical Feed & Maintenance

16.1 Chemical Feed Systems: Metering Pumps, Dry Feeders & Calibration 16.2 Gas Chlorination Equipment & Hypochlorite Systems 16.3 Blowers, Compressors & Aeration Equipment 16.4 Flow Measurement Devices: Meters, Weirs & Flumes 16.5 Preventive Maintenance, CMMS & Asset Management

17 Chapter 17: Utility Management, Administration & Emergency Response

17.1 Planning, Organizing, Directing & Controlling a Utility Work Group 17.2 Budgets, Water Rates & Financial Management 17.3 Operator Training, Staffing & Safety Program Development 17.4 Energy Management & Optimization 17.5 Emergency Response Planning, Risk & Resilience & Security 17.6 Water Conservation Planning & Drought Response

18 Chapter 18: Applied Operator Mathematics Workshop

18.1 The Exam Conversion Sheet, Units & Dimensional Analysis 18.2 Distribution & Hydraulic Math Workshop 18.3 Treatment & Wastewater Process Math Workshop

5.9 Taste & Odor Control and Algal Toxin Management

Key Takeaways Explain This Topic AI

Taste and Odor is a named sub-topic in the treatment processes category and Taste and Odor Analysis is a separate named sub-topic in the laboratory category.

Geosmin and 2-methylisoborneol are the two dominant earthy-musty compounds in California reservoirs and are detectable by taste at 5 to 10 nanograms per liter.

Powdered activated carbon dosed ahead of the rapid mix at 5 to 30 mg/L is the standard episodic response, while granular activated carbon and ozone with biofiltration are the continuous responses.

Chlorinating a heavy cyanobacteria bloom lyses cells and releases intracellular toxin, so pre-oxidation at the intake during a bloom is contraindicated.

The California secondary MCL for odor is a threshold odor number of 3 and for color is 15 units, and both are consumer acceptance standards under 22 CCR 64449.

Last updated: September 2026

Two Blueprint Entries, One Topic

The treatment Expected Range of Knowledge lists Taste and Odor under Water Treatment Processes and Taste and Odor Analysis separately under Laboratory Procedures. The distribution blueprint reaches the same material through Water Quality and through customer complaint response. California adds a regulatory hook: under 22 CCR 64449 the secondary MCL for odor is a threshold odor number (TON) of 3 and for color is 15 units .

Taste and odor is not a health issue in most cases, but it is the issue customers judge the utility on. As the classic operator formulation goes, if the water tastes bad, customers assume it is unsafe - and then they stop trusting the utility about things that genuinely are safety issues.

Where Taste and Odor Comes From

Source Typical descriptors Compounds

Algae and cyanobacteria Earthy, musty, grassy, fishy, septic Geosmin , 2-methylisoborneol (MIB) , cyclocitral, aldehydes

  • Decaying vegetation, anoxic hypolimnion Musty, swampy, rotten egg Organic sulfides, hydrogen sulfide
  • Chlorination of organics Chlorinous, medicinal, chemical Chlorophenols (from chlorine + phenol), chloramines
  • Chloramination imbalance Swimming pool, bleach Dichloramine and trichloramine
  • Iron and manganese Metallic, bitter Fe²⁺, Mn²⁺
  • Industrial or spill contamination Solvent, petroleum VOCs, fuel oxygenates
  • Distribution system Musty, stale, plastic, rubbery Biofilm, stagnant storage, gasket and liner leaching
  • Customer plumbing Sewage, sulfur Water heater anode reactions, drain biofilm, cross-connections
  • The Two Compounds That Matter Most

Geosmin and MIB are semi-volatile metabolites produced by cyanobacteria and actinomycetes. Two properties make them uniquely difficult:

Detection thresholds of roughly 5 to 10 nanograms per liter - parts per trillion. A concentration that a laboratory struggles to quantify is one that customers can taste easily.

They are not oxidized effectively by chlorine, chloramine, or permanganate at practical doses, and they are not removed by coagulation, sedimentation, or conventional filtration .

That combination means the standard treatment train does nothing about them, and the operator needs a dedicated tool.

  • Treatment Options
  • Powdered Activated Carbon (PAC) - the episodic tool

Fed as a slurry, typically 5 to 30 mg/L , at the rapid mix or just ahead of it to maximize contact time before the floc envelopes the carbon particles.

Requires contact time before coagulant addition if possible; carbon that gets swept into floc early adsorbs less.

Removed with the sludge in the sedimentation basin and filters.

Never feed PAC and an oxidant at the same point - the carbon consumes chlorine, ozone, or permanganate that was intended for disinfection or iron and manganese oxidation.

Increases sludge volume and can carry over as black turbidity if overdosed or poorly settled.

Granular Activated Carbon (GAC) - the continuous tool

Used as a filter cap replacing anthracite (adsorption plus filtration) or as a post-filter contactor (adsorption only, longer empty bed contact time).

Empty bed contact time (EBCT) of 10 to 20 minutes is typical for taste and odor control.

Exhausts over months to years and must be reactivated or replaced ; breakthrough is monitored by influent/effluent comparison.

Also removes many synthetic organic chemicals and DBP precursors, which is why GAC is a common answer to more than one treatment problem.

Ozone and Advanced Oxidation

Ozone oxidizes geosmin and MIB far more effectively than chlorine, though not completely; typical geosmin and MIB removal is partial and improves with ozone plus hydrogen peroxide (peroxone) , an advanced oxidation process that generates hydroxyl radicals.

Ozone increases assimilable organic carbon , so it should be followed by biologically active filtration to remove the biodegradable products before they feed distribution biofilm.

Ozone also oxidizes iron, manganese, and color, and provides excellent Cryptosporidium inactivation - it solves several problems at once, which is why large California plants adopted it.

Aeration

Effective for volatile odor compounds - hydrogen sulfide, some VOCs, dissolved gases. Ineffective for geosmin and MIB , which are semi-volatile and do not strip well.

Source Control

The cheapest solution is often to not draw the problem in: multi-level intakes , reservoir destratification or hypolimnetic aeration to prevent the anoxic conditions that release sulfide and metals, watershed nutrient control to limit blooms, and short-term intake depth changes during a bloom.

Cyanobacteria and Cyanotoxins

California reservoirs experience harmful algal blooms (HABs) of Microcystis , Anabaena ( Dolichospermum ), Aphanizomenon , and Cylindrospermopsis , producing:

  • Toxin Organ system Notes
  • Microcystins Hepatotoxin (liver) Most common; the toxin behind most California advisories
  • Cylindrospermopsin Hepatotoxin, also kidney Substantially extracellular
  • Anatoxin-a Neurotoxin Fast-acting; implicated in animal deaths
  • Saxitoxins Neurotoxin Also produced by marine dinoflagellates

Warning

Do not pre-chlorinate a heavy cyanobacteria bloom at the intake. Chlorine, permanganate, and ozone all lyse the cells , releasing intracellular toxin into the water in one step. Intact cells can be removed physically by coagulation, sedimentation, and filtration, which takes the toxin out with the cell. The correct sequence in a bloom is: remove the cells intact first , then treat any dissolved extracellular toxin with PAC, GAC, ozone, or advanced oxidation after solids removal. Pre-oxidation in a bloom converts a removable particulate problem into a dissolved one.

California's Harmful Algal Bloom program uses a tiered advisory posting - Caution, Warning, Danger - for recreational waters. For drinking water sources, DDW expects a system with a bloom-prone source to have a monitoring and response plan covering cell counts, toxin analysis, intake management, and treatment adjustments.

Tracing a Complaint

A complaint is data. Work it systematically:

Where and when? Get the address, the time of day, hot or cold tap, first draw or after running.

Is it at the plant? Compare plant effluent TON and any geosmin/MIB results against the complaint. If the plant is clean, the problem is downstream.

Is it clustered? Multiple complaints along one main or downstream of one storage tank points to distribution stagnation, nitrification, or biofilm. A single address points to customer plumbing.

Hot water only? Water heater - anode rod reacting with sulfate-reducing bacteria produces the classic rotten egg odor in hot water only.

Only the first draw? Stagnation in the service line or premise plumbing.

Chlorinous or swimming pool? Check the chloramine ratio - dichloramine and trichloramine are the usual culprits, and the fix is at the plant.

Confirm with a threshold odor number run at 60 °C by a trained panel, and record the result. TON of 3 is the California secondary MCL.