Study guide
11.5 Secondary MCLs, Notification Levels & Response Levels
California Water/Wastewater Operator Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: California Water Regulatory Framework & Certification Ladders
1.1 State Water Board & Regional Boards Structure 1.2 Drinking Water Certification: T1-T5 & D1-D5 Requirements 1.3 Wastewater Certification: Grades I-V & OIT Requirements 1.4 Safe Drinking Water Standards, MCLs & Emerging Contaminants 1.5 California Waterworks Standards (Title 22, Chapter 16) 1.6 Public Water System Types, Permits & the Sanitary Survey
2 Chapter 2: California Water Rights, Title 22 & Environmental Policy
2.1 California Title 22 Recycled Water Standards 2.2 California Environmental Quality Act (CEQA) & Proposition 218 2.3 Water Rights & California Water Resources
3 Chapter 3: Drinking Water Source Quality & Coagulation/Flocculation
3.1 Source Water Quality & Watershed Management 3.2 Coagulation Chemistry & Flash Mixing 3.3 Flocculation & Jar Testing 3.4 Wells, Aquifers & Groundwater Hydraulics 3.5 Raw Water Storage, Clearwells & Reservoir Management
4 Chapter 4: Clarification & Granular Media Filtration
4.1 Sedimentation & Advanced Clarification 4.2 Granular Media Filtration Mechanics & Media Types 4.3 Filter Operation, Backwash Cycles & SWTR Compliance
5 Chapter 5: Disinfection, Oxidation & Advanced Water Treatment
5.1 Chlorination Chemistry & Breakpoint Curves 5.2 Disinfection Kinetics & CT Calculations 5.3 Alternative Disinfection: Ozone, UV & Chlorine Dioxide 5.4 Advanced Treatment: Membranes, AOP & PFAS Adsorption 5.5 Chloramination & Nitrification Control 5.6 Iron & Manganese Removal 5.7 Fluoridation Practice & Compliance 5.8 Corrosion Control Treatment & Water Stability 5.9 Taste & Odor Control and Algal Toxin Management
6 Chapter 6: Wastewater Preliminary & Primary Treatment
6.1 Preliminary Treatment: Screening & Grit Removal 6.2 Primary Clarification Operations 6.3 Primary Sludge Characteristics & Pumping 6.4 Stabilization Ponds, Lagoons & Small-Plant Processes
7 Chapter 7: Secondary Biological Treatment & Activated Sludge
7.1 Activated Sludge Process Fundamentals 7.2 Process Control Parameters: F/M, MCRT & SVI 7.3 Activated Sludge Microbiology & Troubleshooting 7.4 Fixed-Film & Hybrid Biological Processes
8 Chapter 8: Biological Nutrient Removal, Water Reuse & Solids Handling
8.1 Biological Nitrogen Removal: Nitrification & Denitrification 8.2 Biological Phosphorus Removal (EBPR) & Chemical Precipitation 8.3 Anaerobic & Aerobic Digestion 8.4 Sludge Thickening, Dewatering & Biosolids Disposal 8.5 Wastewater Disinfection: Chlorination, Dechlorination & UV
9 Chapter 9: Distribution Systems, Collection Networks & Hydraulics
9.1 Hydraulics, Pressure & Flow Dynamics 9.2 Centrifugal Pumps, Motors & VFDs 9.3 Distribution Network Infrastructure & Cross-Connection Control 9.4 Wastewater Collection Systems, SSMP & FOG Management
10 Chapter 10: Laboratory Analytics, Safety & Water Math
10.1 Water & Wastewater Laboratory Methods 10.2 Laboratory Quality Assurance & Regulatory Reporting 10.3 Chemical Safety, Hazardous Gases & Confined Space 10.4 Essential Water & Wastewater Math for Operators
11 Chapter 11: Federal & California Drinking Water Rules
11.1 The Revised Total Coliform Rule & Assessments 11.2 The Lead and Copper Rule and Service Line Replacement 11.3 Surface Water Treatment Rules & Log Removal Credit 11.4 Stage 1 & Stage 2 Disinfection Byproduct Rules 11.5 Secondary MCLs, Notification Levels & Response Levels 11.6 Public Notification, Consumer Confidence Reports & Recordkeeping
12 Chapter 12: Distribution System Design, Demand & Hydraulics
12.1 System Layout, Pressure Zones & Distribution Maps 12.2 Water Demand, Peaking Factors & Fire Flow 12.3 Distribution Storage: Types, Sizing & Turnover 12.4 Head Loss, C-Factor & Distribution Hydraulic Calculations 12.5 Water Hammer, Surge Control & Air Management
13 Chapter 13: Distribution Equipment Operation, Maintenance & Inspection
13.1 Valves: Types, Operation & Exercising Programs 13.2 Fire Hydrants: Types, Testing & Maintenance 13.3 Water Meters: Types, Accuracy & Meter Management 13.4 Instrumentation, In-Line Sensors, Telemetry & SCADA 13.5 Electrical Systems, Motors & Standby Generators 13.6 External Corrosion, Cathodic Protection & Asset Inspection
14 Chapter 14: Water Mains, Piping & Field Construction
14.1 Pipe Materials & Pipe Selection 14.2 Joints, Fittings, Thrust Restraint & Bedding 14.3 Main Installation, Tapping & Service Line Installation 14.4 Leak Detection, Water Loss Auditing & Main Repair 14.5 Main Cleaning & Maintenance: Flushing, Pigging & Lining 14.6 Excavation, Trench Safety & Utility Locating
15 Chapter 15: Disinfecting Distribution Facilities & Maintaining Water Quality
15.1 Water Main Disinfection (AWWA C651) 15.2 Disinfecting Storage Reservoirs (C652) & Wells (C654) 15.3 Maintaining Distribution Water Quality: Residual, Biofilm & Discolored Water 15.4 Cross-Connection Control Program Administration & Device Testing
16 Chapter 16: Plant Equipment, Chemical Feed & Maintenance
16.1 Chemical Feed Systems: Metering Pumps, Dry Feeders & Calibration 16.2 Gas Chlorination Equipment & Hypochlorite Systems 16.3 Blowers, Compressors & Aeration Equipment 16.4 Flow Measurement Devices: Meters, Weirs & Flumes 16.5 Preventive Maintenance, CMMS & Asset Management
17 Chapter 17: Utility Management, Administration & Emergency Response
17.1 Planning, Organizing, Directing & Controlling a Utility Work Group 17.2 Budgets, Water Rates & Financial Management 17.3 Operator Training, Staffing & Safety Program Development 17.4 Energy Management & Optimization 17.5 Emergency Response Planning, Risk & Resilience & Security 17.6 Water Conservation Planning & Drought Response
18 Chapter 18: Applied Operator Mathematics Workshop
18.1 The Exam Conversion Sheet, Units & Dimensional Analysis 18.2 Distribution & Hydraulic Math Workshop 18.3 Treatment & Wastewater Process Math Workshop
11.5 Secondary MCLs, Notification Levels & Response Levels
Key Takeaways Explain This Topic AI
Secondary Contaminants is a named sub-topic in the SWRCB treatment Expected Range of Knowledge, distinct from Primary Contaminants.
California secondary MCLs under 22 CCR 64449 include color at 15 units, odor threshold at 3, turbidity at 5 units, iron at 0.3 mg/L, and manganese at 0.05 mg/L.
Total dissolved solids has consumer acceptance ranges of 500 mg/L recommended, 1,000 mg/L upper, and 1,500 mg/L short term rather than a single value.
Notification levels are non-regulatory health-based advisory levels for chemicals that have no MCL, and exceeding one requires notifying the system's governing body.
As of October 29, 2025 the California notification level for both PFOA and PFOS is 4.0 ng/L, with response levels of 10 ng/L for PFOA and 40 ng/L for PFOS.
Last updated: September 2026
Two Separate Standards, Two Separate Purposes
The Expected Range of Knowledge lists Primary Contaminants and Secondary Contaminants as separate sub-topics, and the distinction is real:
- Primary MCL Secondary MCL
- Protects Health Taste, odor, and appearance (aesthetics)
- Federal status Enforceable Advisory only
- California status Enforceable Enforceable
Violation response Public notification by tier, corrective action Notify the State Board, notify customers, develop a plan
Also called - Consumer acceptance contaminant levels
Important
California enforces secondary MCLs; the federal government does not. This is one of the most distinctive features of California drinking water regulation and a reliable exam item. A California system exceeding the 0.05 mg/L manganese secondary MCL has a real compliance obligation, whereas the same system in a state with only federal requirements would face only customer complaints.
The California Secondary MCLs (22 CCR 64449)
- Constituent Secondary MCL
- Color 15 units
- Odor - threshold 3 (threshold odor number)
- Turbidity 5 units
- Iron 0.3 mg/L
- Manganese 0.05 mg/L
- Aluminum 0.2 mg/L
- Copper 1.0 mg/L
- Zinc 5.0 mg/L
- Silver 0.1 mg/L
- Chloride 500 mg/L (recommended range)
- Sulfate 500 mg/L (recommended range)
- Foaming agents (MBAS) 0.5 mg/L
- Thiobencarb 1 µg/L
- Total dissolved solids Range: 500 recommended / 1,000 upper / 1,500 short term (mg/L)
- Specific conductance Range: 900 / 1,600 / 2,200 µS/cm
- The Ranges
Chloride, sulfate, total dissolved solids, and specific conductance are expressed as consumer acceptance contaminant level ranges rather than single numbers:
- Recommended - the level at which most consumers are satisfied
- Upper - acceptable where a lower level is not reasonably achievable
- Short term - acceptable only for an existing system on a temporary basis while corrective action is planned
A system above the recommended level is not automatically in violation, but it must demonstrate that the recommended level is not reasonably achievable and it may need a waiver under 22 CCR 64449.2 .
Why the Numbers Are Where They Are
- Constituent Consumer experience at the secondary MCL
- Iron 0.3 mg/L Reddish-brown staining of laundry and fixtures, metallic taste
- Manganese 0.05 mg/L Black to purple-black staining; deposits in mains that release as black water
- Copper 1.0 mg/L Blue-green staining, bitter metallic taste
- Color 15 units Visible yellow-brown tint from natural organic matter or metals
- Odor TON 3 Detectable earthy, musty, or chlorinous odor to a sensitive panel at 60 °C
- Zinc 5.0 mg/L Astringent taste, milky appearance
- TDS 500 mg/L Salty or mineral taste; scaling in appliances
Aesthetic exceedances drive customer perception of safety. A system that meets every primary MCL but delivers black water will be perceived as unsafe, and it will lose the public confidence it needs when a real health event occurs.
Notification Levels and Response Levels
California created a third tier for chemicals that have been detected in drinking water but for which no MCL has been adopted yet . This framework is unique among the states and is a major reason California regulatory questions differ from generic ABC-style questions.
Term Definition
Notification level (NL) A non-regulatory, health-based advisory level established for contaminants in drinking water for which MCLs have not been established
Response level (RL) Set higher than the NL ; the recommended concentration at which water systems consider taking a source out of service or providing treatment
What a System Must Do
Exceeding an NL: notify the system's governing body (city council, board of directors) and inform the State Water Board; DDW also recommends customer notification.
Exceeding an RL: under Health and Safety Code section 116378 , the system must either remove the source from service, treat the water delivered, or provide public notification.
Current PFAS Notification and Response Levels
- PFAS Notification level Response level Effective
- PFOA 4.0 ng/L 10 ng/L October 29, 2025
- PFOS 4.0 ng/L 40 ng/L October 29, 2025
- PFHxS 3.0 ng/L 10 ng/L October 29, 2025
- PFHxA 1.0 µg/L 10 µg/L October 29, 2025
- PFBS 500 ng/L 5,000 ng/L March 5, 2021
The October 2025 revision tightened the PFOA notification level from 5.1 ng/L and the PFOS notification level from 6.5 ng/L, both to 4.0 ng/L , while leaving the response levels unchanged.
Tip
Keep three PFAS number sets straight. (1) California notification levels - advisory, above triggers governing-body notification. (2) California response levels - above triggers source removal, treatment, or public notification under HSC 116378. (3) Federal MCLs for PFOA and PFOS at 4.0 ng/L, with the associated federal rule currently in flux. A California operator answers first from the state framework, because it has applied continuously since 2019 and is being tightened while the federal rule is contested.
Other notable California notification levels include 1,2,3-trichloropropane (which subsequently received an MCL of 0.005 µg/L), NDMA at 10 ng/L, 1,4-dioxane at 1 µg/L, and hexavalent chromium , which now carries a California MCL of 10 µg/L . California has repeatedly used the NL framework as a staging ground before adopting an MCL, so a chemical on the NL list today is a candidate for regulation tomorrow.