Study guide

16.5 Preventive Maintenance, CMMS & Asset Management

California Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: California Water Regulatory Framework & Certification Ladders

1.1 State Water Board & Regional Boards Structure 1.2 Drinking Water Certification: T1-T5 & D1-D5 Requirements 1.3 Wastewater Certification: Grades I-V & OIT Requirements 1.4 Safe Drinking Water Standards, MCLs & Emerging Contaminants 1.5 California Waterworks Standards (Title 22, Chapter 16) 1.6 Public Water System Types, Permits & the Sanitary Survey

2 Chapter 2: California Water Rights, Title 22 & Environmental Policy

2.1 California Title 22 Recycled Water Standards 2.2 California Environmental Quality Act (CEQA) & Proposition 218 2.3 Water Rights & California Water Resources

3 Chapter 3: Drinking Water Source Quality & Coagulation/Flocculation

3.1 Source Water Quality & Watershed Management 3.2 Coagulation Chemistry & Flash Mixing 3.3 Flocculation & Jar Testing 3.4 Wells, Aquifers & Groundwater Hydraulics 3.5 Raw Water Storage, Clearwells & Reservoir Management

4 Chapter 4: Clarification & Granular Media Filtration

4.1 Sedimentation & Advanced Clarification 4.2 Granular Media Filtration Mechanics & Media Types 4.3 Filter Operation, Backwash Cycles & SWTR Compliance

5 Chapter 5: Disinfection, Oxidation & Advanced Water Treatment

5.1 Chlorination Chemistry & Breakpoint Curves 5.2 Disinfection Kinetics & CT Calculations 5.3 Alternative Disinfection: Ozone, UV & Chlorine Dioxide 5.4 Advanced Treatment: Membranes, AOP & PFAS Adsorption 5.5 Chloramination & Nitrification Control 5.6 Iron & Manganese Removal 5.7 Fluoridation Practice & Compliance 5.8 Corrosion Control Treatment & Water Stability 5.9 Taste & Odor Control and Algal Toxin Management

6 Chapter 6: Wastewater Preliminary & Primary Treatment

6.1 Preliminary Treatment: Screening & Grit Removal 6.2 Primary Clarification Operations 6.3 Primary Sludge Characteristics & Pumping 6.4 Stabilization Ponds, Lagoons & Small-Plant Processes

7 Chapter 7: Secondary Biological Treatment & Activated Sludge

7.1 Activated Sludge Process Fundamentals 7.2 Process Control Parameters: F/M, MCRT & SVI 7.3 Activated Sludge Microbiology & Troubleshooting 7.4 Fixed-Film & Hybrid Biological Processes

8 Chapter 8: Biological Nutrient Removal, Water Reuse & Solids Handling

8.1 Biological Nitrogen Removal: Nitrification & Denitrification 8.2 Biological Phosphorus Removal (EBPR) & Chemical Precipitation 8.3 Anaerobic & Aerobic Digestion 8.4 Sludge Thickening, Dewatering & Biosolids Disposal 8.5 Wastewater Disinfection: Chlorination, Dechlorination & UV

9 Chapter 9: Distribution Systems, Collection Networks & Hydraulics

9.1 Hydraulics, Pressure & Flow Dynamics 9.2 Centrifugal Pumps, Motors & VFDs 9.3 Distribution Network Infrastructure & Cross-Connection Control 9.4 Wastewater Collection Systems, SSMP & FOG Management

10 Chapter 10: Laboratory Analytics, Safety & Water Math

10.1 Water & Wastewater Laboratory Methods 10.2 Laboratory Quality Assurance & Regulatory Reporting 10.3 Chemical Safety, Hazardous Gases & Confined Space 10.4 Essential Water & Wastewater Math for Operators

11 Chapter 11: Federal & California Drinking Water Rules

11.1 The Revised Total Coliform Rule & Assessments 11.2 The Lead and Copper Rule and Service Line Replacement 11.3 Surface Water Treatment Rules & Log Removal Credit 11.4 Stage 1 & Stage 2 Disinfection Byproduct Rules 11.5 Secondary MCLs, Notification Levels & Response Levels 11.6 Public Notification, Consumer Confidence Reports & Recordkeeping

12 Chapter 12: Distribution System Design, Demand & Hydraulics

12.1 System Layout, Pressure Zones & Distribution Maps 12.2 Water Demand, Peaking Factors & Fire Flow 12.3 Distribution Storage: Types, Sizing & Turnover 12.4 Head Loss, C-Factor & Distribution Hydraulic Calculations 12.5 Water Hammer, Surge Control & Air Management

13 Chapter 13: Distribution Equipment Operation, Maintenance & Inspection

13.1 Valves: Types, Operation & Exercising Programs 13.2 Fire Hydrants: Types, Testing & Maintenance 13.3 Water Meters: Types, Accuracy & Meter Management 13.4 Instrumentation, In-Line Sensors, Telemetry & SCADA 13.5 Electrical Systems, Motors & Standby Generators 13.6 External Corrosion, Cathodic Protection & Asset Inspection

14 Chapter 14: Water Mains, Piping & Field Construction

14.1 Pipe Materials & Pipe Selection 14.2 Joints, Fittings, Thrust Restraint & Bedding 14.3 Main Installation, Tapping & Service Line Installation 14.4 Leak Detection, Water Loss Auditing & Main Repair 14.5 Main Cleaning & Maintenance: Flushing, Pigging & Lining 14.6 Excavation, Trench Safety & Utility Locating

15 Chapter 15: Disinfecting Distribution Facilities & Maintaining Water Quality

15.1 Water Main Disinfection (AWWA C651) 15.2 Disinfecting Storage Reservoirs (C652) & Wells (C654) 15.3 Maintaining Distribution Water Quality: Residual, Biofilm & Discolored Water 15.4 Cross-Connection Control Program Administration & Device Testing

16 Chapter 16: Plant Equipment, Chemical Feed & Maintenance

16.1 Chemical Feed Systems: Metering Pumps, Dry Feeders & Calibration 16.2 Gas Chlorination Equipment & Hypochlorite Systems 16.3 Blowers, Compressors & Aeration Equipment 16.4 Flow Measurement Devices: Meters, Weirs & Flumes 16.5 Preventive Maintenance, CMMS & Asset Management

17 Chapter 17: Utility Management, Administration & Emergency Response

17.1 Planning, Organizing, Directing & Controlling a Utility Work Group 17.2 Budgets, Water Rates & Financial Management 17.3 Operator Training, Staffing & Safety Program Development 17.4 Energy Management & Optimization 17.5 Emergency Response Planning, Risk & Resilience & Security 17.6 Water Conservation Planning & Drought Response

18 Chapter 18: Applied Operator Mathematics Workshop

18.1 The Exam Conversion Sheet, Units & Dimensional Analysis 18.2 Distribution & Hydraulic Math Workshop 18.3 Treatment & Wastewater Process Math Workshop

16.5 Preventive Maintenance, CMMS & Asset Management

Key Takeaways Explain This Topic AI

Equipment Installation and Repair and Troubleshoot and Repair Pumps and Motors are named sub-topics in the SWRCB distribution Equipment category, and Maintenance Plan is named in the regulations category.

Maintenance strategies range from reactive to preventive to predictive to reliability-centered, and the right mix depends on the consequence of failure.

22 CCR 64600 requires a public water system to have an operations and maintenance plan.

Predictive tools include vibration analysis, infrared thermography, oil analysis, motor circuit analysis, and ultrasonic detection.

Asset management ranks work by criticality, the product of likelihood of failure and consequence of failure, rather than by age alone.

Last updated: September 2026

Maintenance Is a Regulatory Requirement

22 CCR 64600 requires a public water system to establish a Water System Operations and Maintenance Plan , and the distribution blueprint lists Maintenance Plan as a named sub-topic under Drinking Water Regulations / Management / Safety - the category worth 35 questions at D4 and 45 at D5 . On the wastewater side, 23 CCR 3701(c)(4) puts supervision and management responsibilities including operator training and budget control into the Grade IV blueprint, and a maintenance program sits squarely inside that.

Maintenance is also a sanitary survey element : "system management and operation" is one of the eight elements, and an inability to demonstrate a maintenance program is a documented deficiency.

The Four Strategies

Strategy Description Appropriate when

Reactive (run to failure) Fix it when it breaks The asset is cheap, redundant, and non-critical , and failure has no downstream consequence - a light fixture, a spare hose

Preventive (time or run-hour based) Service on a fixed interval Failure modes are age-related and the interval is known - oil changes, filter changes, valve exercising, generator exercise

Predictive (condition-based) Measure condition and act on the trend The asset is expensive or critical and has a measurable degradation signal - large motors, blowers, high service pumps

Reliability-centered (RCM) Analyze each failure mode and choose the strategy that addresses it High-consequence systems where a structured analysis pays for itself

Important

Not everything should be on a PM schedule. Over-maintaining is a real failure mode: every intervention introduces a chance of infant mortality from a mis-assembly, a contaminated lubricant, or a disturbed connection. The question is always what failure mode does this task prevent? If the answer is "none, we've always done it," the task is a candidate for elimination.

Designing a Preventive Maintenance Program

Build an asset register. Every asset with a unique ID, location, make, model, serial number, size or rating, installation date, and parent system.

Rank by criticality. Criticality = Likelihood of Failure × Consequence of Failure \text{Criticality} = \text{Likelihood of Failure} \times \text{Consequence of Failure} Criticality = Likelihood of Failure × Consequence of Failure

Consequence includes public health, permit compliance, customers affected, safety, environmental impact, and repair cost. A small chemical feed pump with no standby at a plant with no other disinfection can be more critical than a large pump with three redundant units.

Define tasks and intervals from the manufacturer's requirements, industry practice, and your own failure history. Intervals may be calendar-based , run-hour based , or condition-based .

Write the task so anyone can do it - specific steps, torque values, lubricant type and quantity, acceptance criteria, and required PPE and lockout points.

Schedule and level the workload so PM does not all land in one week.

Close the loop. Record what was found, not just that the task was done. "Found coupling insert worn, replaced" is data; "PM complete" is not.

Typical Intervals

Asset Typical PM

Pumps Weekly visual and vibration check; quarterly lubrication; annual alignment verification; seal and packing per condition

  • Motors Annual megger insulation test; thermography under load; bearing lubrication per schedule
  • Blowers Inlet filter differential monitoring; lubrication; annual relief valve test
  • Distribution valves Exercise annually for critical/boundary, every 1-3 years for the rest
  • Hydrants Annual inspection and operational test
  • Generators Weekly no-load exercise; annual load bank test
  • Backflow assemblies Annual certified test
  • Chemical feed pumps Monthly drawdown calibration; diaphragm/tube replacement per hours
  • Analyzers Daily to weekly grab-sample verification; scheduled reagent and electrode service
  • Storage tanks Routine exterior/vent/hatch inspection; interior inspection every 3-5 years
  • Predictive Technologies

Technology Detects

Vibration analysis Imbalance (1x running speed), misalignment (2x, axial), bearing defects (high-frequency bearing tones), looseness, cavitation (broadband random), impeller damage. The single most valuable rotating-equipment tool

Infrared thermography Hot electrical connections, overloaded conductors, failing breakers, bearing overheating, steam and insulation losses. A loose lug shows up as a hot spot long before it fails

  • Oil analysis Wear metals, water and glycol contamination, viscosity change, additive depletion
  • Motor circuit analysis / megger Insulation deterioration, winding faults, rotor bar problems

Ultrasonic detection Compressed air leaks (pure wasted energy), steam trap failures, early bearing distress, electrical arcing

Performance trending Pump head-capacity versus the original curve; blower pressure at a reference airflow; specific capacity of a well; C-factor of a main

Tip

Performance trending is free predictive maintenance. A pump whose delivered flow at a given head has fallen 15 percent has worn wear rings or a damaged impeller, and you learned it from SCADA data you already had. A blower whose discharge pressure at constant airflow has risen has fouled diffusers. A well whose specific capacity has fallen has a fouled screen. None of that requires a new instrument.

CMMS

A computerized maintenance management system turns maintenance from memory into a managed process. Core functions: the asset register, PM scheduling and automatic work order generation, corrective work orders, work history by asset , parts inventory linked to assets, labor and cost tracking, and reporting.

Metrics worth watching:

  • PM compliance - percentage of scheduled PMs completed on time
  • PM to corrective ratio - a healthy program trends toward more planned than reactive work
  • Mean time between failures (MTBF) by asset class
  • Backlog in crew-weeks - a backlog that grows steadily means the program is under-resourced
  • Emergency work percentage - the clearest signal of program health

Work history is the real payoff. When the same pump has been rebuilt four times in three years, the CMMS is the record that justifies replacing it rather than rebuilding it a fifth time - and that record is what turns a maintenance opinion into a capital budget request.

Spare Parts

Stock decisions follow criticality and lead time:

Category Policy

Critical spares - single points of failure with long lead times Stock , even at high carrying cost. A custom pump shaft with a 20-week lead time on a non-redundant service is a stocking decision, not an inventory optimization problem

  • Consumables - gaskets, seals, filters, lubricants, belts Min/max reorder points
  • Common parts - standard bearings, fasteners Vendor-managed or local supply

Standardization Specifying fewer pump, motor, and valve models across the utility cuts inventory dramatically and increases the odds that a spare fits

Asset Management

Asset management links maintenance to capital planning by answering five questions:

What do I own? The asset register and the distribution system map.

What is it worth? Replacement cost, and the value of the service it provides.

What is its condition and remaining life? Condition assessment, break history, performance trending.

What is its criticality? Consequence of failure.

What is my best investment strategy? The lowest life-cycle cost that maintains the required level of service at an acceptable risk . Business Risk Exposure = Probability of Failure × Consequence of Failure \text{Business Risk Exposure} = \text{Probability of Failure} \times \text{Consequence of Failure} Business Risk Exposure = Probability of Failure × Consequence of Failure

The output is a capital improvement plan driven by risk rather than by age, and a rate structure that funds renewal and replacement rather than deferring it. In California, a utility that cannot demonstrate this is a utility with a technical, managerial, and financial capacity problem, and TMF capacity is a permit issue - which is how maintenance planning connects back to the Division of Drinking Water.