Study guide
3.4 Scissors & Other Cutting Instruments
CBSPD CSIS Certified Surgical Instrument Specialist Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The CSIS Exam & Care of Surgical Instruments
1.1 CSIS Exam Blueprint, Eligibility & Logistics 1.2 Instrument Composition & Finish 1.3 Grades of Stainless Steel 1.4 Methods to Prevent Instrument Damage
2 Chapter 2: Instrument Anatomy & Naming Conventions
2.1 Anatomy of an Instrument: Jaws, Shanks & Box Locks 2.2 Instrument Naming Conventions & Classification
3 Chapter 3: General Instruments — Identification by Proper Name
3.1 Hemostatic Clamps 3.2 Grasping & Holding Instruments 3.3 Tissue & Thumb Forceps 3.4 Scissors & Other Cutting Instruments 3.5 Needle Holders & Suturing Instruments 3.6 Suction, Dilators, Probes & Accessory Instruments
4 Chapter 4: Retractors, Endoscopic, Robotic & Powered Systems
4.1 Handheld Retractors 4.2 Self-Retaining & Table-Mounted Retractors 4.3 Laparoscopic Instruments & Accessories 4.4 Robotic Instruments & Accessories 4.5 Navigational Systems & Their Instrumentation 4.6 Surgical Instrument Tracking Systems 4.7 Powered Surgical Equipment
5 Chapter 5: Specialty Instrument Sets
5.1 Orthopedic Instruments: Trauma 5.2 Orthopedic Instruments: Total Joints 5.3 Neurosurgical Instruments 5.4 Vascular & Cardiovascular-Thoracic Instruments 5.5 ENT & Dental Instruments 5.6 GU & GYN Instruments 5.7 Plastic & Microsurgical Instruments
6 Chapter 6: Components, Assembly & Configuration of Individual Sets
6.1 Instrument Make-Up for Various Sets 6.2 Count Sheets, Names & Set Configuration 6.3 Assembly Mechanics: Stringers, Protection & Weight
7 Chapter 7: Instrument Inspection & Safety Testing
7.1 Inspection for Cleanliness: Frequency 7.2 Inspection for Cleanliness: Methods 7.3 Staining, Spotting & Corrosion Identification 7.4 Testing Scissors 7.5 Testing Hinged Instruments: Box Locks & Ratchets 7.6 Testing Forceps & Clamps 7.7 Testing Needle Holders 7.8 Inspection & Testing of Laparoscopic Instruments 7.9 Insulation Inspection: Frequency 7.10 Insulation Testing: Methods
8 Chapter 8: Instrument Marking & Specialty Device Inspection
8.1 Acceptable Instrument Identification & Marking Methods 8.2 Correct Application of Instrument Marking Tape 8.3 Maintenance of Marking Methods 8.4 Inspection of Rigid & Semi-Rigid Scopes 8.5 Inspection of Flexible Scopes 8.6 Inspection of Robotic Instruments 8.7 Inspection & Testing of Power Equipment 8.8 Inspection of Harmonic Scalpels & Advanced Energy Devices 8.9 Inspection of Cameras, Light Cords & Optics 8.10 Inspection of Stereotactic Sets 8.11 Inspection of Sigmoidoscope Sets 8.12 Removal From Service, Repair & Replace Decisions
9 Chapter 9: Loaner & Implant Sets and Components
9.1 Loaner Program Fundamentals & Receipt 9.2 Inspection of Loaner Instruments 9.3 Testing of Loaner Instruments 9.4 Set Configuration of Loaner Instruments 9.5 Documentation Process for Loaner & Implant Sets
10 Chapter 10: Ethics in Surgical Instrument Processing
10.1 Professional Ethics & Accountability 10.2 Ethics of Cleanliness 10.3 Ethics of Functionality 10.4 Correct Instrument on the Set 10.5 Completeness of Sets 10.6 Reporting Instrument Damage & Abuse
3.4 Scissors & Other Cutting Instruments
Key Takeaways Explain This Topic AI
Mayo scissors are heavy dissecting scissors with a short blade-to-shank ratio; Metzenbaum scissors are delicate with long shanks and a short blade.
Curved Mayo scissors cut tissue while straight Mayo scissors, often called suture scissors, cut suture and are the ones sent for the roughest work.
Potts-Smith angled scissors open a vessel in vascular work; iris and tenotomy scissors are the fine straight and curved microscissors.
Wire and bandage scissors must never be used on tissue, and using tissue scissors on wire is instrument abuse reportable under the Ethics content area.
Scalpel handles are identified by number: #3 takes #10 through #15 blades, #4 takes #20 through #25, and #7 is the long fine handle.
Last updated: August 2026
Reading a Scissor
Every pair of surgical scissors can be described with four attributes, and the exam relies on all four: blade-to-shank ratio, blade tip (blunt/blunt, sharp/blunt, sharp/sharp), curvature, and overall length.
The blade-to-shank ratio is the fastest cue. A Mayo has a comparatively short shank and a substantial blade — a stubby, heavy look. A Metzenbaum has long slender shanks and a short, fine blade — an elegant, long-legged look. Once you see the proportion, you rarely confuse them again.
The Core Scissors
- Scissor Length Character Use
- Mayo, curved 5.5–9 in Heavy blade, blunt tips Cutting heavy tissue and fascia
- Mayo, straight 5.5–9 in Heavy blade, blunt tips Suture scissors — cutting suture and supplies
Metzenbaum ("Metz") 5.5–11 in Long shanks, short fine blade, blunt tips, usually curved Delicate tissue dissection
- Iris ~4.5 in Fine, sharp/sharp, straight or curved Ophthalmic and fine plastics
- Tenotomy (Stevens) ~4.5–5 in Very fine, blunt or sharp Tendon and fine dissection
- Potts-Smith 7 in Angled blade at 25, 45, 60, or 90 degrees Opening a vessel (arteriotomy)
- Jorgenson 9 in Strongly curved heavy blade GYN, cutting the vaginal cuff
- Bandage (Lister) 5.5–8 in Blunt probe tip on lower blade Cutting dressings off skin
- Wire cutting Varies Short heavy blade, often TC Cutting surgical wire only
- Suture removal ~4.5 in Hooked lower blade Removing skin sutures
Straight Mayo = suture; curved Mayo = tissue. That single sentence answers a large share of scissor questions. In practice, straight Mayos are the workhorses that dull fastest because they cut suture, drain tubing, and packing.
Supercut and Tungsten Carbide Scissors
Supercut : one blade is razor-honed, giving a much finer cut. Traditionally identified by black ring handles (sometimes black-and-gold). Supercut edges cannot be resharpened by ordinary methods and require the manufacturer's process.
Tungsten carbide scissors : identified by gold ring handles with TC insert edges that hold sharpness far longer and can be re-inserted rather than scrapped.
Both are premium instruments and both attract misuse. A supercut Metzenbaum used on suture is destroyed in a single case.
Scalpel Handles and Blade Pairing
Blade-and-handle mismatch is a frequent assembly error and a frequent exam item.
- Handle Blades it accepts Notes
- #3 #10, #11, #12, #15 The standard general handle
- #3L / #3 long #10, #11, #12, #15 Extended reach
- #4 #20, #21, #22, #23, #25 Larger blades, heavier cuts
- #7 #10, #11, #12, #15 Long, slender, pencil-like; fine work
- #9 #10–#15 Flat handle for delicate work
- Beaver handle Beaver miniature blades Ophthalmic, ENT, hand
Blade shapes: #10 curved belly (general skin), #11 straight pointed stab blade, #12 curved hook (sinus/tonsil), #15 small curved belly (precise short incisions), #20–#23 larger versions of #10 for the #4 handle.
Inspection point: scalpel handles are checked so the blade seat is not burred or spread — a worn seat lets a blade rock or detach, which is both a sharps injury risk and a retained-fragment risk.
Other Cutting and Dissecting Instruments
Rongeurs (Kerrison, Leksell, Stille-Luer): spring-loaded, bite bone or disc. The Kerrison has a footplate and an up-biting punch and comes in stated widths and angles.
Osteotomes and chisels : an osteotome is bevelled on both sides, a chisel on one . This is a classic exam discrimination.
Curettes (Volkmann, bone, uterine): looped or cupped scraping ends, sized by number.
Bone cutters and pin cutters : heavy dual-action cutting forceps.
Elevators / periosteal elevators (Key, Cobb, Freer, Langenbeck): lift periosteum or tissue planes.
Meniscotome, Beaver blade, dermatome : specialty cutting devices.
Cutting-Instrument Abuse
Using a tissue scissor on wire, suture, drapes, or tubing is the definitive example of instrument abuse in the Ethics content area. It flattens or notches the edge in one use, and the damage is usually visible as a nick partway down the blade — the exact point where the wire was cut. A specialist who sees a repeating pattern of notched Metzenbaums is looking at a practice problem in the OR, and the correct action is to document and escalate, not simply to keep replacing scissors.
Why Scissors Are Deliberately Set-Specific
Nothing destroys a scissor faster than using it on the wrong material, which is why departments maintain separate lines on the count sheet for scissors that look broadly similar.
Tissue scissors — Metzenbaum, Mayo (tissue pattern), Potts-Smith, iris — cut only living tissue. Suture scissors , typically a straight Mayo, cut suture material and nothing else. Dressing or bandage scissors , such as the Lister with its blunt flattened lower tip, cut dressings and are never used on tissue. Wire scissors carry a notch and hardened blades for cutting surgical wire; using a tissue scissor on wire will notch the edge permanently in a single cut.
The exam frames this as both an identification question and an ethics question. If a set arrives with the suture scissors visibly notched, the specialist's obligation is to remove it and report the pattern, because a notched edge means the instrument has been used outside its indication somewhere upstream.
Curved, Straight, and the Rule of Thumb That Follows
The conventional teaching is straightforward and testable: curved scissors for tissue, straight scissors for suture . Curvature lets the surgeon see past the blade and follow tissue planes; straight blades give a clean, controlled cut on a suture end. A Mayo scissor exists in both forms, and the count sheet will distinguish "Mayo curved" from "Mayo straight" as separate items.
Length follows depth, exactly as with clamps. The Metzenbaum is available from roughly 5 to 11 inches, and the long versions serve deep pelvic and thoracic work. The scissors that arrive with the finest, most delicate blades — iris, tenotomy, Westcott — are microsurgical or ophthalmic items and require tip protectors during assembly.
Dissectors, Elevators and Osteotomes
The blueprint groups cutting with dissecting, so know the non-scissor cutters too. A Freer elevator is a double-ended, flat, semi-sharp instrument for lifting periosteum and mucoperichondrium. A Key or Cobb elevator performs the same lifting function on bone at a larger scale. Osteotomes have a bevel on both faces and are driven with a mallet to cut bone; chisels are bevelled on one face only; gouges carry a curved, trough-shaped blade for scooping bone. These three are constantly confused, and the single-versus-double bevel is the discriminator.
Curettes are looped or cupped scrapers, rongeurs bite away bone with cupped jaws, and Kerrison rongeurs punch upward through bone with a footplate and are inspected for a clean, unnicked cutting rim.